OPTEX INS-HX-80N Visual Verification Pir Camera Installation Guide
- June 16, 2024
- OPTEX
Table of Contents
- Important Information
- Before installation
- Safety Precaution
- Step 1 Installation
- Step 2 IP address settings
- Step 3 Device registration to CHeKT portal
- Step 4 Camera angle and PIR area settings
- Step 5 Checking
- Specifications
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
OPTEX INS-HX-80N Visual Verification Pir Camera
Important Information
Full information is available at https://navi.optex.net/manual/50427
This “Quick Guide” is the part of the entire installation instructions that
guides the installation procedures for installers.
Get the full information of the installation instructions from the web site.
If you need a guide to the operation of the whole system, please consult the
installer of the entire system.
Before installation
Manufacturer’ s statement
Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.
Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage.
Prohibition
Recommendation
Special attention is required to the section of this symbol.
Safety Precaution
Parts identification
Accessories
-
4 x 20 mm
Mounting screws -
T20 Torx wrench
-
Waterproof cap for LAN connection
CHeKT account
If you do not have a CHeKT account, request a dealer account by visiting the “CHeKT dealer” , before Step 3. Refer to the “CHeKT support” for more details.
CHeKT dealer
www.chekt.com/registration
CHeKT support
https://support.chekt.com
Step 1 Installation
-
Remove the mounting plate
-
Install the mounting plate using 2 screws
NOTE To pass cables through the wall, drill a 25 mm (1″) or larger hole in the wall.- Use a single gang box for exposed wiring.
-
Connect cables to device.
-
Secure the main body
Put the main body back on the mounting plate.
Do not pinch the cables during assembly.
The default network type of InSight is dynamic.
If you have a DHCP server, it will automatically set the InSight.
Step 2 IP address settings
If you do not have a DHCP server, it will set as follows after one minute.
Initial address: Refer to the label on the InSight
User name: root
Default password: OPTEX
Change your password as appropriate.
Download IP installer;
https://navi.optex.net/firmware/50427
InSight Camera manual
https://navi.optex.net/manual/50427/en/?type=cameramanual
Step 3 Device registration to CHeKT portal
Setup your CHeKT Dealer Portal:
- Go to http://dealer.chekt.com/ to log in.
- Select the Customer on the left side of the dashboard.
- Select the Site Devices tab.
- Select the bridge device to be associated with the sensor camera.
- Access the bridge settings using the gear icon to its right.
- Select the appropriate tab to register the PIR camera.
Refer to the site for more details.
CHeKT support
https://support.chekt.com
Step 4 Camera angle and PIR area settings
Changing for each item in this step is optional.
Check the default settings and if no changes are required, proceed to the next
item.
Further information, refer to the “INS-HX-80N Full manual” on the Web.
INS-HX-80N Full manual
https://navi.optex.net/manual/50427/en/?type=installationinstructions
Horizontal adjustings
-
Remove the Back cover.
-
Adjust horizontal angle.
Only one side needs to be loosened.
Vertical adjustings
-
PIR area adjustment
Do not use the vertical angle adjustment of the main unit other than adjusting the detection area surface to be parallel to the ground inclination.
-
Camera angle adjustment
Loosen the screw to adjust camera angle
Angle can be adjusted with either left or right screw
It is recommended that use the Camera angle at 25° to 35° since camera images may appear white and blurred in dark scenes.
PIR/VCA settings
Refer to the InSight VCA manual for details on Camera angle and PIR area settings.
InSight VCA manual
https://navi.optex.net/manual/50426/en/?type=VCAmanual
If the vertical angle of the camera is to be adjusted, adjustment of this sections must be matched to ensure the best performance of the sensor.
Detection range limit
The default settings are 18 m (60′) at 2.5 m (8’2″) mounting height. If no changes are required, proceed to the next item.
INS-HX-80N Full manual
https://navi.optex.net/manual/50427/en/?type=installationinstructions
Switch settings
- Change DIP switch settings as needed
- Change PIR sensitivity setting as needed
Put on the back cover
Step 5 Checking
Walk test: Check the detection area by walking around the area.
System check: Check the image at the time of detection on the monitoring
portal.
Specifications
Model | INS-HX-80N |
---|---|
Detection method | Passive infrared |
PIR coverage | 24 m x 2.0 m (80′ x 6’7”) narrow |
PIR zones | 20 zones |
PIR distance | 6.5 m (22’), 10 m (33’), 13 m (43’), Default: ** _18 m |
(60’)_** , 24 m (80’)
Detectable speed| 0.3 to 1.5 m/s (1′ to 5’/s)
Sensitivity| 2.0℃ ( 3.6°F) at 0.6 m/s
Power input| PoE (IEEE 802.3af compliant) Mini-jack 12 V DC 420 mA max.
Terminal 9.5 to 18 V DC/ 35 mA max. at 12 V DC
Alarm period| 2.0 ± 1 s
Warm-up period| Approx. 60 s (LED blinks)
Alarm output| N.C./N.O. switchable, 28 V DC 0.1 A max.
Tamper output| N.C. 28 V DC 0.1 A max. Open when the cover is opened
LED indicator| [1] Warm-up [2] Alarm
Image sensor| 1/2.8” CMOS
Viewing angle| H: 114° V: 61°
Minimum illumination| Color: 0.02 lux. 0 lux. with IR
IR illumination| Visible up to 12 m
Night vision| Day & Night Automatic/Manual switching
Image compression| H.264, H.265, MJPEG
Resolution/ frame rate| 1080/ 30 fps, D1 (704 x 480 or 704 x 576)
Network protocol| IPv4: TCP/IP, UDP, RTP(UDP/TCP), RTSP, NTP, HTTP, HTTPS,
SSL, DHCP, SNMPv1/v2/v3(MIB-2), ONVIF
Security| HTTPS(SSL), IP filtering, 802.1x, Digest authentication (ID/PW)
Operation temperature| -30℃ to +50℃(-22°F to +122°F)
Environment humidity| 95% max.
International protection| IP 55
Mounting| Wall (Outdoor, Indoor)/Gang box
Mounting height| 2.5 to 3.0 m (8′ 2″ to 10′)
Weight| 1.2 kg (42.3 oz)
Accessories|
- Mounting screw (4 x 20 mm) x 2
- T20 Torx wrench x 1
- Waterproof cap for LAN connector x 1
- Specifications and designs are subject to change without prior notice.
- These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
Detection area
-
Top View
-
Side View
-
Default mounting height:
Dimensions
Compliance
Personal Information
This product is equipped with the function to produce moving image of the designated area and its surrounding, but not equipped with the function to store or register such image. Prior to the installation of this product, the compliance to local laws and regulations needs to be confirmed by the user of this product for the lawful installation and use of this product, and signage and notification when using this product. User of this product is deemed to be responsible for the compliance of any laws and regulations relating to personal information, privacy protection and rights of portrait upon use of this product. Image taken by this product is required to be treated appropriately under the responsibility of the user of this product. Installation of this product, producing image, monitoring, recording with camera and handling of personal information or data shall all be performed under discretion and responsibility of user of this product, and OPTEX shall not be held liable for any dispute between a user and a third party.
FCC notification
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
About distribution of source code for open source software
This product includes open source software(” OSS”) distributed under OSS License. In compliance with the OSS Licenses such as GPL (GNU GENERAL PUBLIC LICENSE), LGPL (GNU LESSERGENERAL PUBLIC LICENSE), and/or others included, we are making the source code of the OSS available, at the actual cost, to our customer upon his/her request. The source code corresponding to OSS included in this product will be provided in a prescribed manner for at least than three(3) years after the date of purchase. Please note that the OSS is provided without warranty of any kind.
How to reset to the factory default
Follow the steps below to perform a factory reset (for example, forget the password). The IP address, ID, password and camera settings are initialized.
Do not pinch the cables during assembly.
EU/UK contact information
Customer Support
https://navi.optex.net/cert/contact/
OPTEX CO., LTD. (JAPAN)
www.optex.ne
OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com
OPTEX SECURITY B.V.
(The Netherlands)
www.optex-europe.com/nl
OPTEX SECURITY SAS (France)
www.optex-europe.com/fr
OPTEX SECURITY Sp.z o.o. (Poland)
www.optex-europe.com/pl
OPTEX PINNACLE INDIA,
PVT., LTD. (India)
www.optexpinnacle.com
OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD. SHANGHAI OFFICE (China)
www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
www.optex.co.th
Copyright (C) 2021-2022 OPTEX CO.,LTD.
References
- Dealer
- Registration - CHeKT
- Homepage | Optex Europe
- Homepage | Optex Europe
- Homepage | Optex Europe
- Homepage | Optex Europe
- OPTEX ASEAN | Sensor and system designed in Japan
- OPTEX Global Site
- Leading manufacturer of high performance sensing technologies - Optex America
- 奥泰斯电子(东莞)有限公司-红外对射探测器|双鉴探测器|被动红外探测器|室外探测器|报警系统|联网报警
- Optex - Leading Sensing Technologies Manufacturer
- Contact Information
- navi.optex.net/firmware/50427
- ISN-QXI-ST(English)
- 50427 INS-HX-80N
- INS-HX-80N(English)
- INS-HX-80N(English)
- support.chekt.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>