HYTRONIK PIR Standalone Motion Sensor with Mesh Instruction Manual
- June 4, 2024
- HYTRONIK
Table of Contents
Installation and Instruction Manual
PIR Standalone Motion Sensor with Mesh
One DALI Channel Output
HBIR29/SV HBIR29/SV/R HBIR29/SV/H HBIR29/SV/RH
Technical Specifications
Operation frequency | 2.4 GHz – 2.483 GHz |
---|---|
Transmission power | 4 dBm |
Range (Typical indoor) | 10~30m |
Protocol | **** Mesh |
Stand-by power | <0.65W (Empty load) |
Operating voltage | 220~240VAC 50/60Hz |
Switched power | 5s |
Warming-up | Max. 40 devices, 80mA |
Sensor principle | PIR detection |
Detection range (Max.)
HBIR29/SV| Installation Height: 5m
Detection Range (Ø) :9m
Detection range (Max.)
HBIR29/SV/R| Installation Height: 6m
Detection Range(Ø) :10m
Detection range (Max.)
HBIR29/SV/H| Installation height:15m (forklift) 12m (person)
Detection range (Ø):24m
Detection range (Max.)
HBIR29/SV/RH| Installation height:15m (forklift) 2m (person)
Detection range (Ø):40m
Detection angle| 360º
Operation temperature| Ta:-20º C~+50º C
IP rating| IP20
Standard compliance| EN300328, EN301489-1,
EN301489-17, EN62479,
EN55015, EN61547,
EN60669-1, EN60669-2-1,
EN62493
Certification| CB, CE , EMC, RED, RCM
Download the App
The access to Silvair apps mobile app: Silvair on the App Store
web app: platform.silvair.com
Installation
Mechanical Structure & Dimensions
Wiring Diagram
Wire Preparation
Pluggable screw terminal. It is recommended to make connections to the terminal before fitting to the sensor.
Mesh Factory Reset
The device HBIR29/SV/SV can be reset by placing a strong magnet (e.g. N38 neodymium magnet, d=10mm*h=4mm) near the sensor lens for 5 seconds. Once the factory reset is done successfully, the luminaire flashes and then permanent on, then the device is being able to be re-commissioned by SILVAIR app.
To Reprovision
Place a strong magnet on the site of the Reset/Hall effect sensor (see diagram 4 below). To trigger the reset the magnet must be held in position for 5 seconds.
Note: When change the lens part of HBIR29/SV/SV, please kindly make sure that the lens fits the right location, where the “Reset dot” and “BLE dot” matches with the physical location on the PCB.
Status LED blinking Sequence
HBIR29/SV/SV Unprovisioned | 30ms ON | 300ms OFF |
---|---|---|
HBIR29/SV/SV Provisioned | 15ms ON | 2,000ms OFF |
Factory reset | 500ms ON | 1,000ms OFF |
Factory reset (initial burst) | 100ms ON | 1,000ms OFF |
MESH package received | 30ms ON | 50ms OFF |
Attention (from network) | 500ms ON | 500ms OFF |
Detection Pattern & Optional Accessories
1. HBIR29/SV (Low-bay)
HBIR29/SV: Low-bay flat lens detection pattern for single person @ Ta =
20ºC (Recommended ceiling mount installation height 2.5m-6m)
Mount height
2.5m
3m
4m
5m
6m| Tangential (A)
max 50m² (Ø = 8m)
max 64m² (Ø = 9m)
max 38m² (Ø = 7m)
max 38m² (Ø = 7m)
max 38m² (Ø = 7m)| Radial (B)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
---|---|---
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
2. HBIR29/SV/R (Reinforced Low-bay)
HBIR29/SV/R: Low-bay convex lens detection pattern for single person @ Ta =
20ºC (Recommended ceiling mount installation height 2.5m-6m)
Mount height
2.5m
3m
4m
5m
6m| Tangential (A)
max 79m² (Ø = 10m)
max 79m² (Ø = 10m)
max 64m² (Ø = 9m)
max 50m² (Ø = 8m)
max 50m² (Ø = 8m)| Radial (B)
max 20m² (Ø = 5m)
max 20m² (Ø = 5m)
max 20m² (Ø = 5m)
max 20m² (Ø = 5m)
max 20m ² (Ø = 5m)
---|---|---
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
3. HBIR29/SV/H (High-bay)
HBIR29/SV/H: High-bay lens detection pattern for forklift @ Ta = 20º
C(Recommended ceiling mount installation height 10m-15m)
Mount height
10m
11m
12m
13m
14m
15m| Tangential (A)
max 380m² (Ø = 22m)
max 452m² (Ø = 24m)
max 452m² (Ø = 24m)
max 452m² (Ø = 24m)
max 452m² (Ø = 24m)
max 452m² (Ø = 24m)| Radial (B)
max 201m² (Ø = 16m)
max 201m² (Ø = 16m)
max 201m² (Ø = 16m)
max 177m² (Ø = 15m)
max 133m² (Ø = 13m)
max 113m² (Ø = 12m)
---|---|---
HBIR29/SV/H: High-bay lens detection pattern for single person @ Ta = 20º C (Recommended ceiling mount installation height 2.5m-12m)
Mount height
2.5m
6m
8m
10m
11m
12m| Tangential (A)
max 50m² (Ø = 8m)
max 104m² (Ø = 11.5m)
max 154m² (Ø = 14m)
max 227m² (Ø = 17m)
max 269m² (Ø = 18.5m)
max 314m² (Ø = 20m)| Radial (B)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
---|---|---
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
4. HBIR29/SV/RH (Reinforced High-bay with 3-Pyro)
HBIR29/SV/RH: Reinforced high-bay lens detection pattern for forklift @ Ta
= 20º C (Recommended ceiling mount installation height 10m-15m)
Mount height
10m
11m
12m
13m
14m
15m| Tangential (A)
max 346m² (Ø = 21m)
max 660m² (Ø = 29m)
max 907m² (Ø = 34m)
max 962m² (Ø = 35m)
max 1075m² (Ø = 37m)
max 1256m² (Ø = 40m)| Radial (B)
max 177m² (Ø = 15m)
max 177m² (Ø = 15m)
max 154m² (Ø = 14m)
max 154m² (Ø = 14m)
max 113m² (Ø = 12m)
max 113m² (Ø = 12m)
---|---|---
HBIR29/SV/RH: Reinforced high-bay lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-12m)
Mount height
2.5m
6m
8m
10m
11m
12m| Tangential (A)
max 38m² (Ø = 7m)
max 154m² (Ø = 14m)
max 314m² (Ø = 20m)
max 531m² (Ø = 26m)
max 615m² (Ø = 28m)
max 707m² (Ø = 30m)| Radial (B)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
---|---|---
Optional Accessory — Ceiling/Surface Mount Box: HA03
Additional Information / Documents
- Regarding precautions for PIR Sensors installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->PIR Sensors – Precautions for Product Installation and Operation
- Datasheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/bluetooth technology ->Partnership
- Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy
WWW.HYTRONIK.COM
Subject to change without notice.
HBIR29/SV/SV-20201012-A0
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>