Technical Specifications

Operation frequency 2.4 GHz – 2.483 GHz
Transmission power 4 dBm
Range (Typical indoor) 10~30m
Protocol **** Mesh
Stand-by power <0.65W (Empty load)
Operating voltage 220~240VAC  50/60Hz
Switched power 5s
Warming-up Max. 40 devices, 80mA
Sensor principle PIR detection

Detection range (Max.)
HBIR29/SV| Installation Height: 5m
Detection Range (Ø) :9m
Detection range (Max.)

HBIR29/SV/R| Installation Height: 6m
Detection Range(Ø) :10m
Detection range (Max.)
HBIR29/SV/H| Installation height:15m (forklift) 12m (person)
Detection range (Ø):24m
Detection range (Max.)

HBIR29/SV/RH| Installation height:15m (forklift) 2m (person)
Detection range (Ø):40m
Detection angle| 360º
Operation temperature| Ta:-20º C~+50º C
IP rating| IP20
Standard compliance| EN300328, EN301489-1,
EN301489-17, EN62479,
EN55015, EN61547,
EN60669-1, EN60669-2-1,
EN62493
Certification| CB, CE , EMC, RED, RCM

Download the App

The access to Silvair apps mobile app: Silvair on the App Store
web app: platform.silvair.com

Installation

Mechanical Structure & Dimensions

Wiring Diagram

Wire Preparation

Pluggable screw terminal. It is recommended to make connections to the terminal before fitting to the sensor.

Mesh Factory Reset

The device HBIR29/SV/SV can be reset by placing a strong magnet (e.g. N38 neodymium magnet, d=10mm*h=4mm) near the sensor lens for 5 seconds. Once the factory reset is done successfully, the luminaire flashes and then permanent on, then the device is being able to be re-commissioned by SILVAIR app.

To Reprovision

Place a strong magnet on the site of the Reset/Hall effect sensor (see diagram 4 below). To trigger the reset the magnet must be held in position for 5 seconds.

Note: When change the lens part of HBIR29/SV/SV, please kindly make sure that the lens fits the right location, where the “Reset dot” and “BLE dot” matches with the physical location on the PCB.

Status LED blinking Sequence

HBIR29/SV/SV Unprovisioned 30ms ON 300ms OFF
HBIR29/SV/SV Provisioned 15ms ON 2,000ms OFF
Factory reset 500ms ON 1,000ms OFF
Factory reset (initial burst) 100ms ON 1,000ms OFF
MESH package received 30ms ON 50ms OFF
Attention (from network) 500ms ON 500ms OFF

Detection Pattern & Optional Accessories

1. HBIR29/SV (Low-bay)
HBIR29/SV: Low-bay flat lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-6m)

Mount height
2.5m
3m
4m
5m
6m| Tangential (A)
max 50m² (Ø = 8m)
max 64m²  (Ø = 9m)
max 38m²  (Ø = 7m)
max 38m²  (Ø = 7m)
max 38m²  (Ø = 7m)| Radial (B)
max 13m²  (Ø = 4m)
max 13m²  (Ø = 4m)
max 13m²  (Ø = 4m)
max 13m²  (Ø = 4m)
max 13m²  (Ø = 4m)
---|---|---

Optional Accessory — Ceiling/Surface Mount Box: HA03

Optional Accessory — Blind Insert for Blocking Certain Detection Angles

2. HBIR29/SV/R (Reinforced Low-bay)
HBIR29/SV/R: Low-bay convex lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-6m)

Mount height
2.5m
3m
4m
5m
6m| Tangential (A)
max 79m²  (Ø = 10m)
max 79m²  (Ø = 10m)
max 64m²  (Ø = 9m)
max 50m²  (Ø = 8m)
max 50m²  (Ø = 8m)| Radial (B)
max 20m²  (Ø = 5m)
max 20m²  (Ø = 5m)
max 20m²  (Ø = 5m)
max 20m²  (Ø = 5m)
max 20m ² (Ø = 5m)
---|---|---

Optional Accessory — Ceiling/Surface Mount Box: HA03

Optional Accessory — Blind Insert for Blocking Certain Detection Angles

3. HBIR29/SV/H (High-bay)
HBIR29/SV/H: High-bay lens detection pattern for forklift @ Ta = 20º C(Recommended ceiling mount installation height 10m-15m)

Mount height
10m
11m
12m
13m
14m
15m| Tangential (A)
max 380m²  (Ø = 22m)
max 452m²  (Ø = 24m)
max 452m²  (Ø = 24m)
max 452m²  (Ø = 24m)
max 452m²  (Ø = 24m)
max 452m²  (Ø = 24m)| Radial (B)
max 201m²  (Ø = 16m)
max 201m²  (Ø = 16m)
max 201m²  (Ø = 16m)
max 177m²  (Ø = 15m)
max 133m²  (Ø = 13m)
max 113m² (Ø = 12m)
---|---|---

HBIR29/SV/H: High-bay lens detection pattern for single person @ Ta = 20º C (Recommended ceiling mount installation height 2.5m-12m)

Mount height
2.5m
6m
8m
10m
11m
12m| Tangential (A)
max 50m²  (Ø = 8m)
max 104m²  (Ø = 11.5m)
max 154m²  (Ø = 14m)
max 227m²  (Ø = 17m)
max 269m²  (Ø = 18.5m)
max 314m²  (Ø = 20m)| Radial (B)
max 7m²  (Ø = 3m)
max 7m²  (Ø = 3m)
max 7m²  (Ø = 3m)
max 7m²  (Ø = 3m)
max 7m²  (Ø = 3m)
max 7m²  (Ø = 3m)
---|---|---

Optional Accessory — Ceiling/Surface Mount Box: HA03

Optional Accessory — Blind Insert for Blocking Certain Detection Angles

4. HBIR29/SV/RH (Reinforced High-bay with 3-Pyro)
HBIR29/SV/RH: Reinforced high-bay lens detection pattern for forklift @ Ta = 20º C (Recommended ceiling mount installation height 10m-15m)

Mount height
10m
11m
12m
13m
14m
15m| Tangential (A)
max 346m²  (Ø = 21m)
max 660m²  (Ø = 29m)
max 907m²  (Ø = 34m)
max 962m²  (Ø = 35m)
max 1075m²  (Ø = 37m)
max 1256m²  (Ø = 40m)| Radial (B)
max 177m²  (Ø = 15m)
max 177m²  (Ø = 15m)
max 154m²  (Ø = 14m)
max 154m²  (Ø = 14m)
max 113m²  (Ø = 12m)
max 113m²  (Ø = 12m)
---|---|---

HBIR29/SV/RH: Reinforced high-bay lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-12m)

Mount height
2.5m
6m
8m
10m
11m
12m| Tangential (A)
max 38m²  (Ø = 7m)
max 154m²  (Ø = 14m)
max 314m²  (Ø = 20m)
max 531m²  (Ø = 26m)
max 615m²  (Ø = 28m)
max 707m²  (Ø = 30m)| Radial (B)
max 7m²  (Ø = 3m)
max 7m²  (Ø = 3m)
max 7m²  (Ø = 3m)
max 13m²  (Ø = 4m)
max 13m²  (Ø = 4m)
max 13m²  (Ø = 4m)
---|---|---

Optional Accessory — Ceiling/Surface Mount Box: HA03

Additional Information / Documents

  1. Regarding precautions for PIR Sensors installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->PIR Sensors – Precautions for Product Installation and Operation
  2. Datasheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/bluetooth technology ->Partnership
  3. Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy

WWW.HYTRONIK.COM
Subject to change without notice.
HBIR29/SV/SV-20201012-A0

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HYTRONIK User Manuals

Related Manuals