PIR Standalone Motion Sensor with Mesh
One DALI Channel Output
HBIR29/SV HBIR29/SV/R HBIR29/SV/H HBIR29/SV/RH
Technical Specifications
| Operation frequency | 2.4 GHz – 2.483 GHz |
|---|---|
| Transmission power | 4 dBm |
| Range (Typical indoor) | 10~30m |
| Protocol | **** Mesh |
| Stand-by power | <0.65W (Empty load) |
| Operating voltage | 220~240VAC 50/60Hz |
| Switched power | 5s |
| Warming-up | Max. 40 devices, 80mA |
| Sensor principle | PIR detection |
Detection range (Max.)
HBIR29/SV| Installation Height: 5m
Detection Range (Ø) :9m
Detection range (Max.)
HBIR29/SV/R| Installation Height: 6m
Detection Range(Ø) :10m
Detection range (Max.)
HBIR29/SV/H| Installation height:15m (forklift) 12m (person)
Detection range (Ø):24m
Detection range (Max.)
HBIR29/SV/RH| Installation height:15m (forklift) 2m (person)
Detection range (Ø):40m
Detection angle| 360º
Operation temperature| Ta:-20º C~+50º C
IP rating| IP20
Standard compliance| EN300328, EN301489-1,
EN301489-17, EN62479,
EN55015, EN61547,
EN60669-1, EN60669-2-1,
EN62493
Certification| CB, CE , EMC, RED, RCM
Download the App
The access to Silvair apps mobile app: Silvair on the App Store
web app: platform.silvair.com
Installation
Mechanical Structure & Dimensions
Wiring Diagram
Wire Preparation
Pluggable screw terminal. It is recommended to make connections to the terminal before fitting to the sensor.
Mesh Factory Reset
The device HBIR29/SV/SV can be reset by placing a strong magnet (e.g. N38 neodymium magnet, d=10mm*h=4mm) near the sensor lens for 5 seconds. Once the factory reset is done successfully, the luminaire flashes and then permanent on, then the device is being able to be re-commissioned by SILVAIR app.
To Reprovision
Place a strong magnet on the site of the Reset/Hall effect sensor (see diagram 4 below). To trigger the reset the magnet must be held in position for 5 seconds.
Note: When change the lens part of HBIR29/SV/SV, please kindly make sure that the lens fits the right location, where the “Reset dot” and “BLE dot” matches with the physical location on the PCB.
Status LED blinking Sequence
| HBIR29/SV/SV Unprovisioned | 30ms ON | 300ms OFF |
|---|---|---|
| HBIR29/SV/SV Provisioned | 15ms ON | 2,000ms OFF |
| Factory reset | 500ms ON | 1,000ms OFF |
| Factory reset (initial burst) | 100ms ON | 1,000ms OFF |
| MESH package received | 30ms ON | 50ms OFF |
| Attention (from network) | 500ms ON | 500ms OFF |
Detection Pattern & Optional Accessories
1. HBIR29/SV (Low-bay)
HBIR29/SV: Low-bay flat lens detection pattern for single person @ Ta =
20ºC (Recommended ceiling mount installation height 2.5m-6m)
Mount height
2.5m
3m
4m
5m
6m| Tangential (A)
max 50m² (Ø = 8m)
max 64m² (Ø = 9m)
max 38m² (Ø = 7m)
max 38m² (Ø = 7m)
max 38m² (Ø = 7m)| Radial (B)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
---|---|---
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
2. HBIR29/SV/R (Reinforced Low-bay)
HBIR29/SV/R: Low-bay convex lens detection pattern for single person @ Ta =
20ºC (Recommended ceiling mount installation height 2.5m-6m)
Mount height
2.5m
3m
4m
5m
6m| Tangential (A)
max 79m² (Ø = 10m)
max 79m² (Ø = 10m)
max 64m² (Ø = 9m)
max 50m² (Ø = 8m)
max 50m² (Ø = 8m)| Radial (B)
max 20m² (Ø = 5m)
max 20m² (Ø = 5m)
max 20m² (Ø = 5m)
max 20m² (Ø = 5m)
max 20m ² (Ø = 5m)
---|---|---
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
3. HBIR29/SV/H (High-bay)
HBIR29/SV/H: High-bay lens detection pattern for forklift @ Ta = 20º
C(Recommended ceiling mount installation height 10m-15m)
Mount height
10m
11m
12m
13m
14m
15m| Tangential (A)
max 380m² (Ø = 22m)
max 452m² (Ø = 24m)
max 452m² (Ø = 24m)
max 452m² (Ø = 24m)
max 452m² (Ø = 24m)
max 452m² (Ø = 24m)| Radial (B)
max 201m² (Ø = 16m)
max 201m² (Ø = 16m)
max 201m² (Ø = 16m)
max 177m² (Ø = 15m)
max 133m² (Ø = 13m)
max 113m² (Ø = 12m)
---|---|---
HBIR29/SV/H: High-bay lens detection pattern for single person @ Ta = 20º C (Recommended ceiling mount installation height 2.5m-12m)
Mount height
2.5m
6m
8m
10m
11m
12m| Tangential (A)
max 50m² (Ø = 8m)
max 104m² (Ø = 11.5m)
max 154m² (Ø = 14m)
max 227m² (Ø = 17m)
max 269m² (Ø = 18.5m)
max 314m² (Ø = 20m)| Radial (B)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
---|---|---
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
4. HBIR29/SV/RH (Reinforced High-bay with 3-Pyro)
HBIR29/SV/RH: Reinforced high-bay lens detection pattern for forklift @ Ta
= 20º C (Recommended ceiling mount installation height 10m-15m)
Mount height
10m
11m
12m
13m
14m
15m| Tangential (A)
max 346m² (Ø = 21m)
max 660m² (Ø = 29m)
max 907m² (Ø = 34m)
max 962m² (Ø = 35m)
max 1075m² (Ø = 37m)
max 1256m² (Ø = 40m)| Radial (B)
max 177m² (Ø = 15m)
max 177m² (Ø = 15m)
max 154m² (Ø = 14m)
max 154m² (Ø = 14m)
max 113m² (Ø = 12m)
max 113m² (Ø = 12m)
---|---|---
HBIR29/SV/RH: Reinforced high-bay lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-12m)
Mount height
2.5m
6m
8m
10m
11m
12m| Tangential (A)
max 38m² (Ø = 7m)
max 154m² (Ø = 14m)
max 314m² (Ø = 20m)
max 531m² (Ø = 26m)
max 615m² (Ø = 28m)
max 707m² (Ø = 30m)| Radial (B)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
max 13m² (Ø = 4m)
---|---|---
Optional Accessory — Ceiling/Surface Mount Box: HA03
Additional Information / Documents
- Regarding precautions for PIR Sensors installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->PIR Sensors – Precautions for Product Installation and Operation
- Datasheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/bluetooth technology ->Partnership
- Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy
WWW.HYTRONIK.COM
Subject to change without notice.
HBIR29/SV/SV-20201012-A0