BEGA 24 859 Ceiling Mounted Downlight Instruction Manual

June 16, 2024
BEGA

BEGA 24 859 Ceiling Mounted Downlight

Dimensions

Dimension

Instructions for use

Application

Surface mounted downlight with asymmetrical light distribution and high protection class which is designed to illuminate uniformly walls from the ceiling.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or white
Safety glass with optical structure
Silicone gasket
2 mounting holes ø 6mm
Distance apart 140mm
2 cable entries for through-wiring of mains
supply cable ø 7-10.5mm
Connection terminal 2.5₏
Earth conductor connection
BEGA Ultimate Driver®
LED power supply unit
220-240 V ≂ 0/50-60 Hz
DC 176-280 V
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without
switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical
impacts < 2 joule
– Safety mark
– Conformity mark
Weight: 1.6 kg
This product contains light sources of energy efficiency class(es) C

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.

The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

Module connected wattage: 8.7 W
Luminaire connected wattage: 10 W
Rated temperature: ta=25 °C
Ambient temperature: ta max=50 °C

24 859K3

Module designation: LED-1343/830
Colour temperature: 3000 K
Colour rendering index: CRI >80
Module luminous flux: 1550 1m
Luminaire luminous flux: 1189 1m
Luminaire luminous efficiency: 118,9 1m/W

24 859K4

Module designation: LED-1343/840
Colour temperature: 4000K
Colour rendering index: CRI >80
Module luminous flux: 1630 1m
Luminaire luminous flux: 1250 1m
Luminaire luminous efficiency: 125 1m/W

Installation

Undo hexagon socket head screws (wrench size 3) up to the stop and lift luminaire top.
Disconnect plug-connection of the LED connecting cable.
Disconnect the earth conductor connection from the plug connection.
Pass the power connecting cable through the cable entry in the mounting plate.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
Connect the green and yellow protective earth conductor from the luminaire top to the terminal marked 1 in the mounting plate.
Connect the LED connection cable by means of a plug connector.
Make sure that gasket is positioned correctly.
Install the luminaire top, press-on and tighten screws evenly.
It is imperative to observe that the earth conductor connection is not shut between the reflector and luminaire top.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

LED power supply unit DEV-0451/350
LED module 3000K LED-1343/830
LED module 4000K LED-1343/840
Reflector 76 001 792
Gasket 83 001 546