TRIPP LITE 23-11-008 Medical Grade Isolation Transformers Owner’s Manual
- June 16, 2024
- Tripp Lite
Table of Contents
TRIPP LITE 23-11-008 Medical Grade Isolation Transformers
Product Information
Specifications
- Output Power (Watts):
- IS250HG: 250W
- IS500HG: 500W
- IS1000HG: 1000W
- IS1800HG: 1800W
- Outlets:
- IS250HG: 2 NEMA 5-15RHG
- IS500HG: 4 NEMA 5-15RHG
- IS1000HG: 4 NEMA 5-15RHG
- IS1800HG: 6 NEMA 5-15/20RHG
- Medical/Hospital Grade Protection (UL 60601-1 Listed)
Your isolation transformer is UL 60601-1 listed, classified as Class 1, Type B, Continuous Operation, Ordinary Equipment. The isolation transformer is Faraday-shielded and reduces the cumulative leakage currents of all connected equipment below 100 microamps. As a further safety measure, your isolation transformer is equipped with a hospital-grade plug and receptacles to reduce the risk of accidental equipment disconnection.
Installation
- Connect Your Isolation Transformer to Your AC Power Line:
- Plug the power cord into a standard, 3-wire grounded, 120V AC, 60 Hz utility outlet.
- Note: The isolation transformer only meets UL60601-1 when plugged into a hospital-grade outlet.
- Connect Equipment to Your Isolation Transformer:
- Plug the AC power cords of your equipment into your isolation transformer.
- Do not use extension cords or adapters that eliminate the ground connection.
- Connect equipment that requires an external connection to ground to the isolation transformer’s potential equalization conductor, labeled on the unit.
Important Note: Output floating, neutral output conductor not grounded.
Maintenance
Your isolation transformer requires no routine maintenance. There are no user-
serviceable parts inside your isolation transformer; do not open it for any
reason.
2-Year Limited Warranty
This warranty applies only to the original purchaser who must have properly
registered the product within 10 days of purchase.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES.
Regulatory Compliance Identification Numbers
For regulatory compliance certifications and identification, your Tripp Lite
product has been assigned a unique series number. The series number can be
found on the product nameplate label, along with all required approval
markings and information. When requesting compliance information for this
product, always refer to the series number. The series number should not be
confused with the marking name or model number of the product.
Product Registration
Visit tripplite.eaton.com/warranty today to register your new Tripp Lite
product. You’ll be automatically entered into a drawing for a chance to win a
FREE Tripp Lite product!*
FAQ
-
Q: Can I use an extension cord with the isolation transformer?
A: No, do not use extension cords or adapters that eliminate the ground connection. -
Q: How many outlets does each model have?
A: The number of outlets varies by model:- IS250HG: 2 NEMA 5-15RHG outlets
- IS500HG: 4 NEMA 5-15RHG outlets
- IS1000HG: 4 NEMA 5-15RHG outlets
- IS1800HG: 6 NEMA 5-15/20RHG outlets
-
Q: Is the isolation transformer suitable for all applications?
A: No, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application. The individual user should take care to determine before use whether this device is suitable, adequate, or safe for the intended use.
IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
CAUTION! Do not connect to an ungrounded outlet. Do not use extension cords or adapters that eliminate the ground connection. The isolation transformer is designed for indoor use only. Install the isolation transformer away from heat-emitting appliances such as radiators or heat registers. Do not install where excessive moisture or other conductive contaminants are present. Do not use life-support appliances if a malfunction or failure could cause failure or significantly alter the performance of the life-support device. Do not use this equipment within oxygen-enriched atmospheres or 0.3 m at a point from which an oxygen-enriched atmosphere is intentionally ventilated. This equipment is provided with multiple socket-outlets for connection of electrical equipment which may create a system that could result in a reduced level of safety. For additional requirements that apply to the ME system, the responsible organization should refer to IEC 60601-1.
Installation
-
Connect Your Isolation Transformer to Your AC Power Line
Plug the power cord into a standard, 3-wire grounded, 120V AC, 60 Hz utility outlet.
Note: The isolation transformer only meets UL60601-1 when plugged into a hospital-grade outlet. -
Connect Equipment to Your Isolation Transformer
Plug the AC power cords of your equipment into your isolation transformer. Do not use extension cords or adapters that eliminate the ground connection. Connect equipment that requires an external connection to ground to the isolation transformer’s potential equalization conductor, labelled “ ” on the unit. -
Turn Your Isolation Transformer On
Flip the switch to provide clean AC power to the isolation transformer’s receptacles. “ O ” is the ON position,“ I ” the OFF. Do not overload your isolation transformer. Excess load on the isolation transformer will cause its circuit breaker to trip; if it does, the outlets will cease to provide power. Reduce the load on the isolation transformer down to your unit’s Output Power rating by unplugging excess equipment, then depress the circuit breaker rocker to reset the breaker and restore power.
Output floating, neutral output conductor not grounded.
Maintenance
Your isolation transformer requires no routine maintenance. There are no user- serviceable parts inside your isolation transformer; do not open it for any reason.
Specifications
Medical/Hospital Grade Protection (UL 60601-1 Listed)
Your isolation transformer is UL 60601-1 listed, classified as Class 1,
Type B, Continuous Operation, Ordinary Equipment. The isolation transformer is
Faraday-shielded and reduces the cumulative leakage currents of all connected
equipment below 100 microamps. As a further safety measure, your isolation
transformer is equipped with a hospital-grade plug and receptacles to reduce
the risk of accidental equipment disconnection.
2-Year Limited Warranty
Seller warrants this product, if used by all applicable instructions, to be
free from original defects in material and workmanship for 2 years from the
date of initial purchase. If the product should prove defective in material or
workmanship within that period, Seller will repair or replace the product, in
its sole discretion. To obtain service under this warranty you must obtain a
Returned Material Authorization (RMA) number from Tripp Lite or an authorized
Tripp Lite service center. Products must be returned to Tripp Lite or an
authorized Tripp Lite service centre with transportation charges prepaid and
must be accompanied by a brief description of the problem encountered and
proof of date and place of purchase.
This warranty applies only to the original purchaser who must have properly
registered the product within 10 days of purchase.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR DAMAGE RESULTING FROM ACCIDENT,
MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE
WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY
APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF
MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET
FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND
CONSEQUENTIAL DAMAGES.
WARNING: The individual user should take care to determine before use
whether this device is suitable, adequate or safe for the use intended. Since
individual applications are subject to great variation, the manufacturer makes
no representation or warranty as to the suitability or fitness of these
devices for any specific application.
Regulatory Compliance Identification Numbers
For regulatory compliance certifications and identification, your Tripp Lite
product has been assigned a unique series number. The series number can be
found on the product nameplate label, along with all required approval
markings and information. When requesting compliance information for this
product, always refer to the series number. The series number should not be
confused with the marking name or model number of the product.
Product Registration
Visit tripplite.eaton.com/warranty
today to register your new Tripp Lite product. You’ll be automatically entered
into a drawing for a chance to win a FREE Tripp Lite product!*
- No purchase necessary. Void where prohibited. Some restrictions apply. See website for details. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
PRODUCT REGISTRATION
Register your product today for a chance to win an ISOBAR® surge protector in
our monthly drawing!
Tripplite.Eaton.com/warranty
Tripp Lite is now part of Eaton
Eaton 1000 Eaton Boulevard, Cleveland, OH 44122 United States
Eaton.com
© 2023 Eaton. All Rights Reserved
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>