JoyHill EK-64 Series Electronic Kitchen Scale Instruction Manual
- June 16, 2024
- JOYHILL
Table of Contents
ELECTRONIC
TCHEN SCALES
INSTRUCTIONS FOR USE
MAIN FUNCTION
- With high precision load cell
- Water & milk volume measuring function.
- Low battery and over loaded warning function.
- Zero & tare function.
- Auto off function
Division for high precision scale
0.2gm≤200g| d=0.1 g
200grn≤1000g| d=0.5g
1000g≤ m≤3000g (5000g)| d= 1 g
The above table is for indicative only. Each product differs from one to another. For actual division, please refer to the product label.
TO REPLACE BATTERY AND CHARGE
- 2 x 1.5V or 3 x 1.5V(AA/AAA) batteries(excluded) Open the battery cover.Install new batteries by putting one side of the battery down rst and pressing down the other side. (Please observe the polarity)
- 1 pc or 2 pcs 3V CR2032 lithium batteries (included). Remove isolation sheet before use; Open battery cover and take out the used battery with the aid of a sharp object.Install new battery by putting one side of the battery beneath the battery baffle and then pressing down the other side.(Please observe the polarity)
- If the product you bought is re-chargeable, please operate as below:
(1) Please charge the product before use. Indicator light will be on when charging. It takes about 2 hours to be fully charged.
(2) Please use the standard charger with 5V direct voltage, 0.5A output current or above.
(3) It is recommended to charge the product every 3 months if it is not used after long time.
Note: The LED is on when charging. In order to protect your safety, please do not use the weighing function when charging. Take off the power supply after charging before weighing.
BUTTONS FUNCTION
MODE CHANGING, UNIT CHANGING BUTTONS:|
---|---
ON/OFF, ZERO, TARE BUTTONS:
Note:
- Above buttons are for indicative only.
- UNIT button for some items are on bottom of the scale, please set the unit there if needed.
- Buttons and are indicative in this manual.
LED ICONS INDICATION
Bluetooth connection | Zero Weight | T Tare Weight |
---|---|---|
Weight mode | Water mode | M Milk mode |
Power | – Negative Value | fl’oz Volume unit(fl’oz) |
lb:oz Weight unit(lb:oz) | ml Volume unit(ml) | g Weight unit(g) |
LED display differs from one to another, so the above icons are indicative only
WARNING
OVER LOADED WARNING
When LED shows Err, it is over loaded( Max capacity is shown on product),
please take off the loads to prevent damage to the scale.
LOW BATTERY WARNING
When LED shows Lo, battery power is low, please replace with new battery
(ies)
- Place the scale on a solid and flat surface. Place bowl (if any) on the scale.
- Press button to turn on the scale.
- Start weighing when LED shows “0”. Press UNIT button to convert to weighing mode.
- Load weighing object on scale(or bowl) to start weighing. LED will show the weight reading.
VOLUME MEASURING
- Place the scale on a solid and flat surface.
- Press button to turn on.
- Press the UNIT button to convert the mode to water or milk volume mode when LED shows”0″.
- Put a container onto the scale platform, LED shows the weight of the container.
- Press button for Zero or Tare.
- Pour liquid (water or milk) into the container, LED shows the volume of the liquid.
MODE / UNIT TRANSFER
Press UNIT button to switch the mode or unit you need after turning on the
scale, it can be switch cercularly.
There is UNIT button on base of the scale for some models, in this case, you
need to set the unit with the UNIT button on base.
Note: The unit system of scale depends on scale destination or the
requirement of distributor.
ZERO & TARE FUNCTION
To weigh different loads consecutively without removing loads from the scale.
Put first Load on the scale, get weight reading. Press button to reset the LED
reading to “0” before adding next load. You can repeat this operation.
Condition 1: “ZERO” function When total sum of all loads on
scale 4% of scale’s max.weight capacity:
LED will show —– or Og each time is pressed. —– means not stable, please wait
for a moment. Og and meanwhile an icon o on the LED mean ZERO function is
activated. Max.weight capacity remains unchanged.
(For example: When capacity is 2000g, 4% is 80g; When capacity is 5000g, 4% is
200g)
Condition 2: “ TARE” function When total sum of all loads on scale >4% of
scale’s max.weight capacity:
LED will show —– or Og each time is pressed. —– means not stable, please wait
for a moment. Og and meanwhile anicon T on the LED mean TARE function is
activated. Max.Weight capacity is reduced by total weight of all loads.
(For example: When capacity is 2000g, 4% is 80g; When capacity is 5000g, 4% is
200g)
Under this condition : By pressing , you can see the total weight of all
loads on the scale. If you want to weigh more loads, just press to reset LED
reading to ‘0’ again.
AUTO OFF (BATTERY POWER SAVING MODE)
If there is no operation or weight changing in two minutes, scale will be auto off.
MANUALLY SHUT OFF
To maximize battery life, press and hold for seconds to turn off the scale after using.
ADVICE FOR USE & CARE
- Clean the scale with slightly damp cloth. DO NOT immerse the scale in water or use chemical/corrosive cleaner. Keep the scale in cool dry place.
- All plastics parts should be cleaned immediately after contact with fats, spices, vinegar and strongly avored/colored foods. (Avoid contact with acids citrus juice.)
- Always use the scale on a solid, at surface, keep the scale unmoved when weighing.
- This product is precision instrument, please handle with care; Do not strike, shake or drop the scale.
- If fail to turn on, please check whether battery(ies) are installed or battery power is low.
- Keep away from high temperature, do not strip the scale arbitrarily.
- Designed for family use only, not for commercial use.
20EK-064E R1
ISO 9001 CERTIFIED BY SGS
EK-64 SERIES
Documents / Resources
|
JoyHill EK-64 Series Electronic Kitchen
Scale
[pdf] Instruction Manual
EK-64 Series Electronic Kitchen Scale, EK-64 Series, Electronic Kitchen Scale,
Kitchen Scale, Scale
---|---
Read User Manual Online (PDF format)