KICHLER 52595PN Brit Flush Mount Instruction Manual
- June 16, 2024
- KICHLER
Table of Contents
KICHLER 52595PN Brit Flush Mount Instruction Manual
FIXTURE DIAGRAM
PARTS LIST
[A] Canopy
[B] Mounting Strap
[C] Outlet Box (not supplied)
[D] Strap Mounting Screw (Qty. 2)
[E] Countersunk Screw (Qty. 3)
[F] Glass Shade (Qty. 8)
[G] Glass Cover (Qty. 8)
[H] Glass Support (Qty. 8)
[I] Safety Cable (attached to Canopy)
CAUTIONS
CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fuse box before
starting and during the installation.
WARNING:
- This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
CLEANING:
- Always be certain that electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
INSTALLATION INSTRUCTIONS
-
Carefully angle and pass glass shade[F] over glass support[H] by tilting glass shade and walking up over the glass support (Fig. 1). Inside surface of glass shade should sit on pads on top of glass support.
-
While holding glass shade in place with one hand, screw down glass cover[G] clockwise onto glass shade with other hand to secure glass shade to glass cover. DO NOT OVER TIGHTEN.
-
Repeat steps 1 and 2 for remaining glass shades, glass supports, and glass covers.
-
Attach mounting strap[B] to outlet box[C] using strap mounting screws[D]. Mounting strap can be adjusted to suit desired position of fixture.
-
Attach safety cable[I] to mounting strap or to inside of outlet box and secure into place to prevent damage to wires while making wire connections.
-
Grounding instructions: (See Illus. a or b).
a. On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
b. On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.
-
Make wire connections. Reference chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
---|---
Black| White
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
*Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is
square shaped or ridged and the other wire will be round in shape or smooth
(See illus.).
Neutral Wire
-
Raise canopy to ceiling, carefully passing canopy [A] over mounting strap [B].
NOTE: Make sure wires do not get pinched between mounting strap and canopy or between canopy and ceiling. -
Align three (3) holes in the side of canopy [A] with three (3) holes in the side of mounting strap [B].
-
While holding canopy in place, insert countersunk screws [E] into aligned holes and tighten screws to secure fixture to mounting strap.
FCC INFORMATION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
For warranty information please visit: kichler.com/warranty