INSTALLATION INSTRUCTIONS FOR OPTIMA® SYSTEM SENSOR ACTIVATED
SLOAN® CONCEALED WITH SMALL WALL BOX AND TRUE MECHANICAL OVERRIDE
FLUSHOMETERS
152 Optima System Sensor Activated
Concealed Closet Flushometers
1½” Rear Spud 1½”
Model 152 ES-S TMO SWB| 1½” Exposed Rear Spud
Model 140 ES-S TMO SWB| 1½” Top Spud
Model 153 ES-S TMO SWB| Concealed Urinal Flushometer
¾” Rear Spud
Model 195 ES-S TMO SWB
LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants this product,
manufactured and sold for commercial or industrial uses, to be free from
defects in material and workmanship for a period of three (3) years (one (1)
year for special finishes, SF faucets, PWT electronics and 30 days for PWT
software) from date of first purchase. During this period, Sloan Valve Company
will, at its option, repair, replace, or refund the purchase price of any
product which fails to conform with this warranty under normal use and
service. This shall be the sole and exclusive remedy under this warrant.
Products must be returned to Sloan Valve Company, at customer’s cost. No
claims will be allowed for labor, transportation or other costs. This warranty
extends only to persons or organizations who purchase Sloan Valve Company’s
products directly from Sloan Valve Company for purpose of resale. This
warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE
HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL
DAMAGES OF ANY MEASURE WHATSOEVER.
ROUGH-IN
PRIOR TO INSTALLATION
Check the “L” dimension show on the Flushometer package is correct for your
application (available in lengths of 2” to 10¾”). Determine the “L” dimension
for your application by using the following formula:
“L” dimension = Wall Thickness (to nearest the whole inch) + 2-3/4” (69
mm)
Prior to installation, install the items listed below:
- Electrical wiring to the transformer box (120 VAC, 2 amp service required for each EL-154, 24 VAC, 50 VA transformer used)
- Bore a 12” x 12” square hole into wall for wall box
- Bore a 2” (51 mm) opening in wall for piping (if required)
- Closet/Urinal fixture
- Water supply line
- Drain line
Important:
- ALL PLUMBINGING AND ELECTRICAL WIRING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.
- WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
- A 24 VAC STEP-DOWN TRANSFORMER MUST BE USED.
- WHEN INSTALLING A FLUSHOMETER, IT IS IMPORTANT THAT THE FLUSH MODEL MATCHES THE REQUIREMENTS OF THE PLUMBING FIXTURE.
- FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS. Sloan Flushometers are designed to operate with 15 to 100 psi (104 to 689 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED.
Consult fixture manufacturer for minimum pressure requirements.
Most Low Consumption water closets (1.6 gallon/6.0 liter) require a minimum
flowing pressure of 25 psi (172 kPa).
Protect the finish of this Flushometer — DO NOT USE TOOTHED TOOLS TO INSTALL
OR SERVICE THE VALVE.
IMPORTANT: EXCEPT FOR CONTROL STOP INLET, DO NOT USE PIPE SEALANT OR
PLUMBING GREASE ON ANY VALVE COMPONENT OR COUPLING!
Transformer Installation
Install Transformer (EL-154) on a 2-Gang Electrical Box, 4” x 4” x 2-1/2” (102
mm x 102 mm x 64 mm) in a convenient location; refer to the illustration at
lower left side of this page (Figure 1).
Note: One Sloan EL-154 transformer can operate up to ten OPTIMA equipped
Flushometers. Run 18-gauge wire from transformer to Flushometer(s). Wire
supplied by others. DO NOT supply power to transformer until installation of
Flushometer is complete.
Note: A maximum of ten (10) Flushometer units can operate from one (1)
Sloan EL-154 Transformer, Class 2, UL Listed, 50 VA (min.) at 24 VAC, plate
mounted.
Note: Break tiles to allow screw holes in plaster to show.
!!! IMPORTANT !!!
This product contains mechanical and/or electrical components that are subject
to normal wear. These components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
TOOLS REQUIRED FOR INSTALLATION
- Sloan A-50 “Super-Wrench™,” Sloan A-109 Plier Wrench or smooth jawed spud wrench
- 8-32 x 3/4” drilled spanner head – spanner bit provided
- Slotted screwdriver
- Wire stripper/crimping tool
- 5/64” hex wrench (supplied)
- Parker Tube Cutter (PTC)
INSTALL THE WALL BOX
A Assemble Hydraulic Actuator Assembly into the locating carrier in the wall box frame. Install Wall Box in the exact location as illustrated in Figure 1. Secure using appropriate fasteners.![SLOAN 152 Optima System Sensor Activated
- WALL BOX](https://manuals.plus/wp-content/uploads/2023/12/SLOAN-152-Optima-
System-Sensor-Activated-WALL-BOX.jpg)B Slide four (4) U-type Nuts onto frame
at each hole location as shown.
NOTE
Inner Wall EXCEEDS 9” valve center located in 5¾” from the front of the stud. Inlet centerline distance to the lower surface of the box is 2½”-6”.
NOTE
Inner Wall BETWEEN 6”-9” valve center located in 2½” from the front of the stud. Inlet centerline distance to the lower surface of the box is 6” – 7½”.
INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF SUPPLY PIPE DOES NOT HAVE
A MALE THREAD), CONTROL STOP, AND VACUUM BREAKER FLUSH CONNECTION
A To install the optional sweat solder adapter:
Cut water supply line pipe 1-1/4” (32 mm) shorter. Slide Threaded Adapter
fully onto pipe and sweat solder to pipe.
B Install the Sloan Bak-Chek® Control Stop to the water supply line with the
outlet positioned as required. Threaded AdapterC Assemble pipe, elbows, couplings, nylon slip gaskets, rubber
gaskets, and flanges, as illustrated.
D Insert tube into fixture spud.
E Hand tighten all couplings.
!!! IMPORTANT !!!
Never open Control Stop to where the flow from the valve exceeds the flow
capability of the fixture. In the event of a valve failure, the fixture must
be able to accommodate a continuous flow from the valve.
!!! IMPORTANT !!!
With the exception of Control Stop Inlet, DO NOT use pipe sealant or plumbing
grease on any valve component or coupling!
INSTALL FLUSHOMETER
!!! IMPORTANT !!!
For high efficiency urinal flushometers (0.5, 0.25 and 0.125 gpf), it is
necessary to first insert the flow control component into the tailpiece
assembly. See the H1015A flow control kit and separate instructions for
details on how to install.
A Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece into
Control Stop. Tighten Tailpiece Coupling by hand.
B Align Flushometer directly above the Vacuum Breaker Flush Connection by
sliding the Flushometer Body IN or OUT as needed. Tighten Vacuum Breaker
Coupling by hand.
C Align Flushometer Body and securely tighten first the Tailpiece Coupling
(1), then the Vacuum Breaker and Pipe Couplings (2), and finally the Spud
Coupling. Use a wrench to tighten these couplings in the order shown.
NOTE
Max. adjustment of Sloan Adjustable Tailpiece is ½” (13 mm) IN or OUT from the
standard 4¾” (121 mm) (C of Valve to C of Control Stop).
If roughing-in measurement exceeds 5¼” (133 mm), consult factory for longer
tailpiece.
!!! IMPORTANT !!!
Protect the chrome or special finish of Sloan Flushometers — DO NOT USE
toothed tools to install or service these valves.
Use a Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud
wrench to secure all couplings.
Also see “Care and Cleaning” section of this manual.
INSTALL VALVE ACTUATOR
A Cut off excess plastic tubing so that there will be about 3 to 4 inches (72
to 102 mm) of slack when Actuator is installed. If the “L” and “O” markings on
the Tubing will be cut off, remark Tubing appropriately so as not to lose
identification.
B Remove tube fitting nuts from valve actuator and slide one nut onto each
Plastic Tube.
!!! IMPORTANT !!!
MUST USE SLOAN APPROVED TUBING ONLY
NOTE
Observe the “L” and “O” markings on Push Button Actuator. Mark each tube so
that it can be identified and connected to corresponding fittings marked “L”
and “O” on Valve Actuator Housing.
C Slide plastic tubing onto its corresponding valve actuator fitting and
tighten tube fitting nuts.
D Install valve handle cap and adapter assembly (EL-190) on valve opening not
used by hydraulic actuator assembly (typically on back of valve body).
ELECTRICAL HOOK-UP
A Be certain power is OFF to prevent damage to electrical components.
Connect Sensor to Transformer and Solenoid coil EXACTLY as shown.
B Connect the two RED wires from the Circuit Board to the Sensor.
C Connect the two BLACK wires from the Circuit Board to the Solenoid wires
using wire nuts (supplied by others).
D Connect the two wires from the Transformer to the BLUE Terminal Block.
E Secure solenoid operator to Flushometer by tightening the solenoid coupling.
Tighten housing retention nut.
FLUSH OUT SUPPLY LINE
A Make sure Control Stop is CLOSED.
B Remove Flushometer Cover and lift out Inside Parts Assembly. Install
Flushometer Cover wrench tight.
C Open Control Stop. Turn on water supply to flush line of any debris or
sediment.
D Shut off Control Stop, remove Cover and reinstall Inside Parts Assembly.
Install Flushometer Cover wrench tight. Do Not open Control Stop until Step
7.
TURN WATER ON AND ADJUST CONTROL STOP
A Adjust Control Stop to meet the flow rate required for proper cleansing of the fixture. Open Control Stop COUNTERCLOCKWISE one (1) FULL turn from the closed position.B Activate Flushometer by placing hand in front of OPTIMA Sensor Lens for ten (10) seconds and then moving it away.
C Adjust Control Stop after each flush until the rate of flow delivered properly cleanses the fixture.
!!! IMPORTANT !!!
All Sloan Flushometers are engineered for quiet operation.
Excessive water flow creates noise, while too little water flow may not
satisfy the needs of the fixture. Proper adjustment is made when plumbing
fixture is cleansed after each flush without splashing water out from the lip
AND a quiet flushing cycle is achieved.
Never open Control Stop to where the flow from the valve exceeds the flow
capability of the fixture. In the event of a valve failure, the fixture must
be able to accommodate a continuous flow from the valve.
INSTALL ACCESS PANEL
TEST SENSOR OPERATION
A Remove the tape located over the sensor window to activate.
The Flushometer has a factory set sensing range:
Water Closets: 22” to 42” (559 mm to 1067 mm)
Urinals: 15” to 30” (381 mm to 762 mm)
B Sensor flashes upon target detection.
C Stand in front of Sensor for sixteen (16) seconds for closet/eight (8)
seconds for urinal.
D Step away from Sensor and listen for “CLICK.”
NOTE
The factory setting should be satisfactoy for most installations.
OPERATION
-
A continuous, invisible light beam is emitted from the OPTIMA Sensor.
-
When a user enters the beam’s effective range, for water closets 22” – 42” (559 mm – 1067 mm) and for urinals 15” – 30” (381 mm – 762 mm), the beam is reflected into the OPTIMA’s scanning window and transformed into a low voltage electrical signal that
activates a sixteen (16) second (closet) /eight (8) second (urinal) time delay circuit. The time delay circuit eliminates false operation from passers-by in the rest room. Once the time delay is completed, the output circuit is alerted and continues in a “hold” mode for as long as the user remains within the effective range of the sensor. -
When the user steps away from the OPTIMA Sensor, the loss of reflected light initiates an electrical “onetime” signal that energizes the Solenoid Operator, and activates the Flushometer to flush the fixture. This occurs on the water closet approximately three (3) seconds after indication. This delay is built into the Sensor to help prevent false flushing due to movement by the user. The circuit for both water closets and urinals then automatically resets and is ready for the next user.
CARE AND CLEANING
DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean
Flushometer and wall box panel as they may dull the luster and attack the
chrome and/or special decorative finishes. Use ONLY soap and water, then wipe
dry with clean cloth or towel.
While cleaning the bathroom tile, the Flushometer should be protected from any
splattering of cleaner. Acids and cleaning fluids can discolor or remove
chrome plating.
TROUBLESHOOTING GUIDE
NOTE: Upon detection of the user, the red indicator light flashes slowly
for a period of eight seconds. When the user leaves the detection range, the
indicator light flashes rapidly and the Sensor initiates the flush sequence.
Then the indicator light stops flashing and the valve flushes.
The valve will flush after a three-second delay.
-
Valve does not function (red light does not flash when user steps in front of sensor).
A. No power is being supplied to sensor. Ensure that the main power is turned “ON.” Check transformer, leads and connections. Repair or replace as necessary.
B. EL-1500-L Sensor is not operating. Replace the EL-1500-L Sensor. -
Valve does not function (red light flashes when user steps in front of sensor).
A. Red light stops flashing when user steps away and valve makes a “clicking” sound but does not flush.
a. No water is being supplied to the valve. Make certain that the water supply is turned “ON” and the Control Stop is open. No power is being supplied to sensor. Ensure that the main power is turned “ON.” Check transformer, leads and connections. Repair or replace as necessary.
b. EL-128-A cartridge is fouled or jammed. Turn “OFF” electronic power to valve (failure to do so could result in damage to the solenoid coil. Remove the solenoid operator from the valve and remove the EL-128-A cartridge. Clean and/or repair as necessary.
B. The red light stops flashing when user steps away but the valve does NOT make a “clicking” sound and does NOT flush.
a. EL-163-A solenoid shaft assembly is fouled or jammed. Turn electronic power to valve “OFF” (failure to do so could result in damage to the solenoid coil). Remove EL-101 or EL-166 nut from the solenoid operator. Remove the coil from the solenoid operator.
Use a spanner wrench or pliers to remove the EL-163-A solenoid shaft assembly from valve. Clean and/or replace as necessary.
Be sure to replace plunger spring when reassembling Solenoid Shaft Assembly.
C. The red light flashes three (3) short flashes, three (3) long flashes then three (3) short flashes (“S-O-S”) and continues to repeat this cycle even when user steps out of the sensor’s detection range.
a. EL-1500-L Sensor wiring connections are incorrect. Rewire Sensor to valve. One solenoid lead connects to the “TO VALVE” connection on Sensor. One transformer lead connects to the “24 VAC IN” connection on Sensor. Second solenoid lead and second
transformer lead connect together.
b. Wiring to Sensor is ground shorted. Find short in wiring circuit and correct.
c. EL-165-2 solenoid coil is burnt out or coil is not connected to solenoid plunger shaft. Reinstall or replace coil as necessary. -
Volume of water is insufficient to adequately siphon fixture.
A. Control Stop is not open wide enough. Adjust control stop for desired water delivery.
B. Low Consumption unit is installed on Water Saver or Conventional fixture. Replace Diaphragm component parts of valve with kit that corresponds to appropriate flush volume of fixture.
C. Inadequate water volume or pressure available from supply. Increase pressure or supply (flow rate) to the valve. Consult factory for assistance. -
Length of flush is too long (long flushing) or valve fails to shut off.
A. Water Saver valve is installed on Low Consumption fixture. Replace Diaphragm component parts of valve with kit that corresponds to appropriate flush volume of fixture.
B. Relief valve in diaphragm is not seated properly or bypass hole in diaphragm is clogged. Disassemble inside Diaphragm component parts and wash parts thoroughly. Replace worn parts if necessary. -
Water splashes from fixture.
A. Supply flow rate is more than necessary. Adjust Control Stop to meet flow rate required for proper cleansing of the fixture. -
Leakage occuring at the push button.
A. Damaged or worn seals or lime build up in the actuator cartridge.
Replace with new HY-32-A cartridge. -
The flushometer does not flush or flushes only once and will not flush a second time when the button is pushed.
A. The plunger is lodged in the actuator cartridge or the plunger by-pass hole is clogged. Remove the actuator housing and cartridge from the Flushometer. Clean under running water. If cartridge parts are worn, deteriorated or limed up and problem persists after cleaning, replace with new HY-83-A cartridge.
a. Turn off water at the control stop.
b. Unscrew the housing coupling nut from the Flushometer.
c. Remove the actuator housing from the Flushometer. The tubing connections can be left intact.
d. Remove the actuator cartridge from the Flushometer body. Care should be taken so that upon removal the actuator does not abruptly separate due to spring compression within. If the actuator cartridge is lodged in the body cavity, grip the exposed portion gently with a pair of channel- lock pliers and rotate back and forth to loosen the “O” ring seal.
e. Separate the actuator housing to reveal the spring and plunger.
B. Plastic Tubing Installed Incorrectly. Install Plastic Tubing Correctly. -
The Flushometer does not flush and a small amount of leakage is visible below the valve.
A. Foreign material lodged in the cartridge. Remove the cartridge and inspect for foreign material. Clean under running water.
B. Damaged or worn seals or lime build up in the actuator cartridge.
Replace with new HY-32-A cartridge.
a. Remove the button or actuator assembly from the wall or fixture.
b. Disassemble the flange or button assembly from the actuator body.
c. Unscrew the cartridge from the actuator body. Note: The metal push button was designed to be vandal-proof and thus requires removal from the wall for servicing.
C. Plastic Tubing installed incorrectly. Install Plastic Tubing Correctly.
If further assistance is required, please contact Sloan Tech Support at:
1-888-SLOAN-14 (1-888-756-2614)
or visit us online at www.sloan.com
!!! IMPORTANT !!!
THIS PRODUCT CONTAINS MECHANICAL AND/OR ELECTRICAL COMPONENTS THAT ARE SUBJECT
TO NORMAL WEAR. THESE COMPONENTS SHOULD BE CHECK ON A REGULAR BASIS AND
REPLACED AS NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.
!!! IMPORTANT !!!
NEVER OPEN CONTROL STOP TO WHERE THE FLOW FROM THE VALVE EXCEEDS THE FLOW
CAPABILITY OF THE FIXTURE. IN THE EVENT OF A VALVE FAILURE, THE FIXTURE MUST
BE ABLE TO ACCOMMODATE A CONTINUOUS FLOW FROM THE VALVE.
!!! IMPORTANT !!!
WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT USE PIPE SEALANT OR PLUMBING
GREASE ON ANY VALVE COMPONENT OR COUPLING
!!! IMPORTANT !!!
LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED
ON FIXTURE OR FLUSHOMETER
PARTS LIST
Item. No. | Part No. | Description |
---|---|---|
1 A | WB-55-A | Wall Box Cover Plate Assembly Models 152 & 153) |
1B | WB-60-A | Wall Box Cover Plate Assembly Model 195) |
2 | ‡ | Valve Assembly |
3 | A-1013-A | Concealed Valve Handle Cap RB |
4A | EL-138-2 | RB Concealed 24V Solenoid Assembly |
4B | EL-128-A | Cartridae Assembly , |
51 | H-730-A | RB Bak-Chek Control Stop |
6 | HY-83-A | Actuator Cartridge Assemhly |
7 | HY–I flq-A | Valve Actuator Ascernhly |
8 | HY-30 | W’ (6 mml x 48″ (1219 mml Connecting Tubes |
9 | — | 12″ x 12″ x 4″ Wall Box Assembly |
10 | V-500-AA | 11/2″ (38 mm) Vacuum Breaker Assembly RB (Models 152 & 153) |
10A | F-102 | 11/2″ (38 mm) Outlet Tube CP (Model 153) |
10B | F-15-A | 11/2″ (38 mm) Elbow Assembly CP (Moder 153) |
11A | V-500-AA | 3/4″ (19 mm) Vacuum Breaker Assembly RB (Model 195) |
11 B | V-500-AA | 11/2″ (38 mm) Vac. Breaker (Model 140) |
12A | F-2-AA | 11/2 (38 mm) Slip Joint Coupling Assembly RB (Models 152. 153 & |
- 12B| F-2-AW| 3/4″ (19 mm) Slip Joint Coupling Assembly RB (Model 192)
1:3A| I-11U| 1 ‘A” (S2 mm) outlet I me l-iangea ana 5corea (Model 152)
13B| F-100| 1½” (38 mm) Outlet Tube Flanged and Scored (Model 152)
14A| F-2-AU| 1¼” (32 mm) Slip Joint Coupling Assembly RB(Model 152)
14B| F-2-AT| 1½” (38 mm) Slip Joint Coupling Assembly RB (Model 152)
15| F-2-A| 1½” (38 mm) Coupling with S-21 Gasket (Model 152 & 140)
15A| F-56-A| 1½” (38 mm) Spud Coupling Assembly (Model 153 & 140)
16| F-21| 1½” (38 mm) Double Male Slip Joint Elbow
17| F-15-A| ELL with ¾” (19 mm) Tail (Model 195)
18| F-2-AW| ¾” (19 mm) Slip Joint Coupling
19| WB-18| U-Type Nuts (4) ¼-20
20| WB-49| Tamper Resistant Screws (4) ¼-20 x 1½
21| HY-126| Elbow Fitting (2)
22| HY-71-A| Hydraulic Actuator Assembly
23| EL-190-A| Adapter Assembly
24| F-7| Flange CP (Model 153 & 140)
25| WB-5| Sanner Bit #14/1/4”
† “L” Dimension available between the lengths of 2” and 10¾”
‡ Part number varies with valve model variation; consult factory.
SLOAN • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131
Phone: 1-800-982-5839 or
1-847-671-4300 • Fax:
1-800-447-8329 or
1-847-671-4380 •
www.sloan.com
The information contained in this document is subject to change without
notice.
Copyright © 2017 SLOAN
Code No. 0816676 – Rev. 2 (02/17)