CAUTION

  • An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury.
  • These instructions should be followed to avoid the possibility of misapplication or misadjustment.

Parallel Rigid Arm Door Closers with or without Stop

Additional Closer Options

  • “DL” indicates Delayed Action closing.
  • “H” indicates the Hold-Open function. These components are handed
  • “T” indicates Thumbturn actuated Hold-Open control.

Optional Accessories

  • 213 Dropplate
  • 293L, 890, 891 Soffit Plate Accessories.

NOTE: For special applications, a separate door and frame preparation template is packed with these instructions. In those cases, use this instruction sheet for installation sequence and closer adjustments only.

Standard Frame Installation

  • Closer mounts on opposite hinge (push) side of the door. PR51 Parallel Rigid Non-Hold Open arm illustrated.

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-1

Narrow Frame Installation

  • Closer mounts on opposite to hinge (push) side of the door. 5121 Parallel Rigid arm with stop illustrated.
  • 890 and 891 accessories are required for this application (supplied separately).

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-2

Flush Partition Installation

  • Closer mounts on opposite to hinge (push) side of the door. 5121T Parallel Rigid arm with Thumbturn Hold Open illustrated.
  • 293L accessory required for this application (supplied separately).

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-3

Components

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-4

Arm Options

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-5

Preparation for Fasteners

 | Fasteners| Door or Frame| Drill-Sizes
Standard| Self-Drilling Screw| Aluminum or Metal| No drill required
Wood| 3/16” (4.30 mm)
1/4” – 20 machine screw| Metal| Drill: #7 (0.201” dia.) Tap: 1/4” – 20
Optional| Sleeve nuts and bolts| Hollow Metal| 9/32” (7 mm) through; 3/8” (9.5 mm) door face opposite to closer
Aluminum or Wood| 3/8” (9.5 mm) through
Through-bolts and grommet-nuts| All| 9/32” (7 mm);

3/8” (9.5 mm) dia. x 3/8” (9.5 mm) deep on the door opposite to the closer

Note: Wood doors MUST be pre-drilled when using Self-Drilling Screws.

Installation Instructions

  • Select the angle of the opening and use the dimensions shown on and Dimension Chart below to locate 4 holes on the top side of the door for the closer body or 213 drop plate, only if required, and 5 holes on stop and/or rabbet for Soffit Plate. For applications not covered in these instructions, a separate template will be required.
  • Prepare door and frame for fasteners. See “Preparation for Fasteners”,
  • Set closer power for door size using the Power Adjustment Chart below. Use the 1/8″ hex wrench supplied to adjust the Power Adjustment Shaft … 15 turns maximum. Turn nut CLOCKWISE to Increase, COUNTER-CLOCKWISE to Decrease power. See Page 6 for the illustration of this step.
  • Mount 213 Dropplate … only if required.
  • Install closer with a power adjustment screw toward the hinge edge of the door. Note: If using cover, thread in screws before mounting closer. Leave enough gap between the head of the screw and the closer to slide the cover on.
  • With the door closed, use a wrench to rotate the pinion shaft as illustrated below, see Arm Mounting Details. Caution: Closer arm is under spring tension and may be difficult to rotate.
  • Install Main Arm: Close valves – ‘S’ and ‘L’, then turn the pinion shaft more than 50° to permit proper alignment of arms mark with pinion flat –
    • ‘L’ for Left-hand door.
    • ‘R’ for Right-hand door.
  • See “Main Arm Installation Instructions” below.
  • Make closer adjustments before installing the cover … CAUTION: Do not back valves out of closer completely or a leak will result.
  • Reopen valves by turning counterclockwise.
  • With the door closed, align the soffit plate with mounting holes in the frame. Fasten the soffit plate to the frame with flat head screws provided…. use spacer blocks 293S or 891, if required.

Power Adjustment Chart

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-17

Arm Mounting Detail

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-6

Typical Installation

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-7

Dimension

Standard Frame

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-8

Notes

  • Do Not Scale Drawing.
  • Left-Hand Door Shown.
  • The same dimensions apply to the hand Door measured from the centerline of a pivot point.
  • Dimensions are in inches (mm).
  • for A & B dimension values.

Narrow Frame

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-9

Flush Partition

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-10

Drop Plate Mounting Holes

Standard Frame

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-11

Notes

  • Left-Hand Door Shown.
  • The same dimensions apply to Right Hand Door measured from the centerline of a pivot point.
  • Dimensions are in inches (mm).
  • See for A & B dimension values.

Narrow Frame

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-12

Flush Partition

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-13

Thumbturn Hold-Open Feature

The Thumbturn Hold-Open feature is controlled by the knob located on the arm of the unit. Turning this knob clockwise will engage the Hold-Open mechanism and increase the Hold-Open force. Turning this knob counterclockwise will reduce the Hold-Open force and disengage the Hold-Open mechanism.

Friction Hold-Open Feature
Hold a door open to the opening angle desired and tighten the holder adjustment- nut (wrench supplied) or use 1” Box or Open End wrench.

Unit Adjustment

Closing Power Adjustment

  • Using the “Power Adjustment Chart” from Page 3, select the correct number of turns for the power adjustment shaft that corresponds with the installation. With a 1/8” hex-key provided, rotate the adjustment shaft fully 360° clockwise turns to the desired setting.
  • After the closer has been installed and proper adjustments made to the sweep and latch, it may be necessary to readjust the spring power for good closing action.

Control Valve Adjustments

Closing Speed Controls (Figure 1A or 1B and 2.)

  • Valve “S” Controls Sweep Range.
  • Valve “L” Controls Latch Range.

Opening Cycle
The “Backcheck” valve controls the strength of cushioning in the Backcheck Range. NEVER close this valve completely – it is not to provide a positive stop. (see Figure 4 and Figure 5).

Yale-PR50-BF-Parallel-Rigid-Arm-Door-Closers-FIG-16

ASSA ABLOY, the global leader in door-opening solutions

  • Yale ® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
  • Copyright © 2003, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
  • Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

CONTACT

An ASSA ABLOY Group brand

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals