Sloan 8100 HET/HEU Complete Flushometer Models Installation Guide

June 5, 2024
SLOAN

Sloan 8100 HET/HEU Complete Flushometer Models

8100 HET/HEU Complete Flushometer Models
8100 Series Sloan ECOS® Electronic Flush valves are complete Flushometer valves and ideal for new installations.


RESS Series Retrofit Conversion Kit Models
RESS Sloan ECOS® Electronic models are used to convert existing Royal, Sloan, and Regal style Flushometers to sensor operation.

Sloan ECOS® Electronic Dual Flush Water Closet & Urinal Models are furnished for the following:

  • 1.6 gpf/1.1 gpf (6.0 Lpf/4.2 Lpf) For Low Consumption Bowls
  • 1.28 gpf/1.1 gpf (4.8 Lpf/4.2 Lpf) For High Efficiency Bowls
  • 0.5 gpf/1.9 Lpf For Washdown Urinals
  • 0.25 gpf/1.9 Lpf For High Efficiency Urinals
  • 0.125 gpf/1.9 Lpf For High Efficiency Urinals

LIMITED WARRANTY

Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

PRIOR TO INSTALLING THE SLOAN ECOS® DUAL-FLUSH ELECTRONIC FLUSHOMETER

Prior to installing the Sloan ECOS® Electronic Flushometer, install the items listed below as illustrated in the Rough-in Diagram. (New installations only.)

  • Closet fixture

  • Drain line

  • Water supply line
    Important:

  • ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.

  • WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.

  • WHEN INSTALLING A FLUSHOMETER, IT IS IMPORTANT THAT THE FLUSH MODEL MATCHES THE REQUIREMENTS OF THE PLUMBING FIXTURE.

  • FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.

    • The Sloan ECOS® is designed to operate with 15 to 80 PSI (103 to 552 kPa) of water pressure
  • THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED.
    Consult fixture manufacturer for pressure requirements.Most High Efficiency water closets require a minimum flowing pressure of 25 psi (172 kPa). Many building codes and the ASME A112.19.2 fixture standard list Maximum static water pressure as 80 PSI (552 kPa).

TOOLS REQUIRED FOR INSTALLATION

  • Slotted screwdriver to adjust control stop.
  • Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench for couplings.
  • Trimpot adjustment screwdriver (supplied) to adjust range, if necessary.
  • Strap wrench (supplied) to install Sloan ECOS® Electronic to valve body.
  • 7/64” hex wrench (supplied) to secure Sloan ECOS® Electronic cover to base plate.

 VALVE ROUGH-IN

ALTERNATIVE WATER CLOSET INSTALLATION

  • FOR COMPLETE VALVE INSTALLATION, START HERE. FOR RESS RETROFIT INSTALLATIONS, START AT STEP 6. INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD).****
  • INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE****  
  • FLUSH OUT SUPPLY LINE ****
  • INSTALL VACUUM BREAKER FLUSH CONNECTION
  • INSTALL FLUSHOMETER
  • WHEN RETROFITTING AN EXISTING VALVE, START HERE. REMOVE COMPONENTS FROM EXISTING FLUSHOMETER (RESS RETROFIT INSTALLATIONS ONLY)****
  • SLOAN ECOS® ELECTRONIC DUAL-FLUSH VOLUMES (RESS RETROFIT INSTALLATIONS ONLY)****
  • ASSEMBLE FLEX TUBE DIAPHRAGM TO SLOAN ECOS® DUAL-FLUSH ELECTRONIC ASSEMBLY****
  • TIGHTEN LOCKING RING****  
  • REMOVE TAB TO ACTIVATE SENSOR MODULE
  • TEST SENSOR OPERATION****  
  • ADJUST CONTROL STOP AND INSTALL VANDAL RESISTANT STOP CAP****  
  • OPERATION****  
  • RANGE ADJUSTMENT (ADJUST ONLY IF NECESSARY)****
  • BATTERY REPLACEMENT****  
  • TROUBLESHOOTING****
  • PARTS LIST

FCC INFORMATION TO USERS

This equipment has been tested and found to comply with the limits for a class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmfull interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmul interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help

When further assistance is required, please contact Sloan Technical Support at: +1.888.SLOAN.14 (+1.888.756.2614) or visit us online at: sloan.com