SLOAN Optima EAF-250 Installation Guide

June 7, 2024
SLOAN

Repair Parts and Maintenance Guide
Optima® EAF-250

SLOAN Optima EAF-250

EAF-250 Series Faucet date code 1101 and newer. Product revised to make spray head vandal-resistant without the need for special spray. EAF-15 only works on product date code 1052 and older.

SLOAN Optima EAF-250 - FIGURE 10

SLOAN Optima EAF-250 - FIGURE 2

PARTS LIST—EAF-250 FAUCETS

No. Code No. Part No.  Description
1A. 335019 EAF-21-A Faucet Sensor Assembly without i.q.-clicr
1 B. 335018 EAF-20-A Faucet Sensor Assembly with
2. 335027 EAF-27 Cap
3A. 335012 EAF-15 0.5 gpm (1.9 Lpm) VR Aerator Spray Head —

Pre 03/2011
3B.| 335008| EAF-10 2.2 gpm (8.3 Lpm) Aerator Spray Head
3C.| 335011| EAF-13 2.2 gpm (8.3 Lpm) Laminar Flow Spray Head
3D.| 335029| EAF-51 0.35 gpm (1.3 Lpm) Multi-Laminar Spray Head
4.| 3335018| EAF-1003 Battery Replacement Kit (CR-P2)
5.| 335000| EAF-1 Faucet Mounting Kit
6.| 335007| EAF-9 Strainer (Filter)
7A.| 335019| EAF-1004 Mixer Handle Assembly and Cartridge
7B.| 3335020| EAF-1005 Handle Repair Kit
8.| 3335022| EAF-1007 Handle Cap
9.| 3335023| EAF-1008 13″ (330 mm) Flexible Supply Hose (1)
10.| 335001| EAF-2 Solenoid
11.| 3365468| ETF-312-A Trim Plate for 4″ Centerset Sink
362011| SFP-11-A Use when needing 4″ for EAF-35-A extension
12A.| 3365024| ETF-510-A Trim Plate for 8″ Centerset Sink
12B.| 3362022| SFP-22-A Use when needing 8″ for EAF-35-A extension
13.| 3335035| EAF-35-A Faucet Extension Kit
14.| 3335046| EAF-40-A 2-1/4″ Faucet Extension Kit. Raises faucet such
that outlet height complies with California Office of Statewide Health Planning and Development

i.q.-cliq™ SETTINGS

Function

| Press Button|

LED Signal

---|---|---
Continuous Run – 2 minute
default setting (adjustable
from 1 – 20 minutes)| 1 time for 2 seconds| 5 short flashes
       reset:| 1 time or will reset
automatically after
2 minutes|
Temporary Off| 2 times (double click)
periodic flashing| 5 short flashes followed by
            reset:| 1 time or will reset
automatically after
2 minutes|
Auto Set Range Adjustment| 2 times (double click) and
then 1 time for 5 seconds| 5 short flashes followed
by 4 short flashes

TROUBLESHOOTING GUIDE

  1. The faucet DOES NOT function.
    A. “Permanent Off” activated. Press the button on the faucet’s throat one time.

  2. The faucet delivers water in an uncontrolled manner.
    A. Faucet is not working properly. Contact Sloan Technical Support.

  3. The faucet DOES NOT deliver any water when the Sensor is activated.INDICATOR: Solenoid valve produces an audible “CLICK.”
    A. Water supply stop(s) closed. Open water supply stop(s).
    B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s) if required.
    INDICATOR: Solenoid valve DOES NOT produce an audible “CLICK.A. Battery low (battery-powered models). Replace the battery (refer to BatterReplacement on page 184).

  4. The faucet delivers only a slow flow or dribble when the sensor is activated.
    A. Water supply stop(s) are partially closed. Completely open water supply stop(s).
    B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s) if required.
    C. Aerator is clogged. Remove, clean, and reinstall Aerator. Replace Aerator if required.
    D. Faucet is not working properly. Contact Sloan Technical Support.

  5. The faucet DOES NOT stop delivering water or continues to drip after the user is no longer detected.
    A. Faucet is not working properly. Contact Sloan Technical Support.

  6. The LED indicator blinks when the faucet is in use.
    A. Battery low (battery-powered models). Replace the battery (refer to BatterReplacement on page 184).

  7. The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines.
    A. Supply stops are not adjusted properly. Adjust supply stops.
    B. For models with integral mixing valve – The mixing valve is set improperly for the water temperature desired. Rotate the mixing valve handle clockwise to decrease water temperature or counterclockwise to increase the water temperature.

OPERATION

As the user’s hands enter the beam’s effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing water to flow from the faucet. Water will flow until the hands are removed or until the faucet reaches its automatic time-out limit setting.

SLOAN Optima EAF-250 - FIGURE 3

CARE AND CLEANING

DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with a clean cloth or towel. While cleaning the bathroom tile, protect the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating.

SLOAN Optima EAF-250 - FIGURE 4

When assistance is required, please contact Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614).

The information contained in this document is subject to change without notice.

Documents / Resources

| SLOAN Optima EAF-250 [pdf] Installation Guide
Optima EAF-250
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SLOAN User Manuals

Related Manuals