AURA LIGHT I-203 Safie Mirror Installation Guide

September 26, 2024
AURA LIGHT

I-203 Safie Mirror

Product Information

Specifications:

  • Brand: Safie Mirror

  • Manufacturer: Aura Light AB, Sweden

  • Installation Type: Surface mounted

  • IP Rating: IP40 for indoor use only, IP54 suitable for indoor
    areas including bathrooms

  • Dimmer Compatibility: Non-dim and DALI dimming system

Product Usage Instructions:

Installation:

  1. Read the installation manual carefully and ensure you have all
    necessary tools and accessories.

  2. Only a licensed electrician should handle the
    installation.

  3. Turn off the power and allow the fitting to cool down before
    any maintenance, cleaning, or adjustments.

  4. Avoid installing near heat sources and do not exceed voltage or
    amperage ratings.

  5. Ensure power leads and screws are secure before connecting the
    power.

  6. Follow the recommended spacing and clearance guidelines for
    installation.

  7. Refer to the ceiling cutout reference table for appropriate
    dimensions.

  8. Check the IP rating on the luminaire for suitable installation
    location.

  9. Verify dimmer compatibility before installation.

Dimensions:

The product dimensions are as follows: 48mm x 90mm x 81mm x
67.5mm.

Accessories:

Surface mounted cylinder accessories are available for
installation.

FAQ

Q: Can the Safie Mirror be used in wet areas?

A: No, it is recommended for indoor use only. For wet areas,
consider the IP54-rated version suitable for bathrooms and
covered/sheltered spaces.

Q: What dimming systems are compatible with the product?

A: The Safie Mirror works with DALI dimming systems and is not
compatible with other dimmers. Ensure to check the dimmer selection
table before installation.

Q: What should I do if the luminaire is damaged during

installation?

A: If the luminaire is damaged during installation, it should be
destroyed to prevent risks of overheating or fire. Contact customer
service for assistance.

Safie Mirror
Installation manual
Important Safety Instructions Basic safety precautions should always be followed when installing, including the following: 1: Read instructions and check that you have all tools and accessories to complete the installation correctly. 2: Licensed electrician for installation only. 3: Always ensure the power is off and the fitting has cooled down before performing any maintenance,
cleaning, or adjustment to the fitting. 4: Do not install any luminaire near a heat source. 5: Do not exceed the nominal supply voltage or amperage ratings. 6: To avoid injury or damage to the fitting, please ensure that power leads and screws are secure before connecting the power.

Installation Spacing

Thermal Insulation

HCB=25 mm

SCB=25 mm SCG=50 mm

Power supply

Risk of fire! Required clearance from structural members and building elements. SCB=25 mm HCB=25 mm MIC=0 mm SCI=0 mm
Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30 info@auralight.com, www.auralight.com

HCB: Height clearance to building element. MIC: Minimum insulation clearance. SCI: Side clearance to insulation. SCB: Side clearance to building element. SCG: 50 mm.
SCG=side clearance to auxiliary equipment. CG=control gear.

2024-08-12

I-203

Ceiling cutout reference table.

Downlight diameter (mm) 90 (without ring)

Ceiling Cutout (mm)

68

90 (with ring) 83

190 160-170

228 200-210

IP rating table: Before installation, please check the IP label on the luminaire to choose the right place to install.

IP40

Indoor use only, do not use in wet or damp place.

IP54

Suitable for indoor areas including bathrooms and covered/sheltered areas such as porches.

Dimmer selection table: Before installation, please check the information of driver as below.

Non-dim DALI

Can not be used with any dimmer. Only work with DALI dimming system, dimming range 8-100%

Installation Procedure
Warning 1: Switch off before installation. 2:Switch on only after complete installation and examination of the circuit. 3: Professional electrician for installation and maintenance only. 4:Input wire diameter 0.75mm². 5: Product modification and improper installation are not valid for warranty! 6:Light source of the luminaire is non-user-replaceable. If it is damaged,
the luminaire shall be destroyed. 7: Risk of overheating or fire if the clearance distances are compromised!

CAUTION
Risk of electric shock

Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30 info@auralight.com, www.auralight.com

2024-08-12

I-203

Downlight with external driver
1
2
Screw surface mounted installation
1
Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30 info@auralight.com, www.auralight.com

2

2024-08-12

I-203

Screw surface mounted installation

3

4

5

Number of connecting wires depends on driver-option

6

On/Off or DALI.

O
7a

7

8

7b

Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30 info@auralight.com, www.auralight.com

2024-08-12

I-203

Dimensions

48 m m
mm

90 81 67,5
40 Accessories: Surface mounted cylinder

Ø mm

Ø mm

mm
Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30 info@auralight.com, www.auralight.com

mm

2024-08-12

I-203

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>