AURA LIGHT I-203 Safie Mirror Installation Guide
- September 26, 2024
- AURA LIGHT
Table of Contents
I-203 Safie Mirror
Product Information
Specifications:
-
Brand: Safie Mirror
-
Manufacturer: Aura Light AB, Sweden
-
Installation Type: Surface mounted
-
IP Rating: IP40 for indoor use only, IP54 suitable for indoor
areas including bathrooms -
Dimmer Compatibility: Non-dim and DALI dimming system
Product Usage Instructions:
Installation:
-
Read the installation manual carefully and ensure you have all
necessary tools and accessories. -
Only a licensed electrician should handle the
installation. -
Turn off the power and allow the fitting to cool down before
any maintenance, cleaning, or adjustments. -
Avoid installing near heat sources and do not exceed voltage or
amperage ratings. -
Ensure power leads and screws are secure before connecting the
power. -
Follow the recommended spacing and clearance guidelines for
installation. -
Refer to the ceiling cutout reference table for appropriate
dimensions. -
Check the IP rating on the luminaire for suitable installation
location. -
Verify dimmer compatibility before installation.
Dimensions:
The product dimensions are as follows: 48mm x 90mm x 81mm x
67.5mm.
Accessories:
Surface mounted cylinder accessories are available for
installation.
FAQ
Q: Can the Safie Mirror be used in wet areas?
A: No, it is recommended for indoor use only. For wet areas,
consider the IP54-rated version suitable for bathrooms and
covered/sheltered spaces.
Q: What dimming systems are compatible with the product?
A: The Safie Mirror works with DALI dimming systems and is not
compatible with other dimmers. Ensure to check the dimmer selection
table before installation.
Q: What should I do if the luminaire is damaged during
installation?
A: If the luminaire is damaged during installation, it should be
destroyed to prevent risks of overheating or fire. Contact customer
service for assistance.
Safie Mirror
Installation manual
Important Safety Instructions Basic safety precautions should always be
followed when installing, including the following: 1: Read instructions and
check that you have all tools and accessories to complete the installation
correctly. 2: Licensed electrician for installation only. 3: Always ensure the
power is off and the fitting has cooled down before performing any
maintenance,
cleaning, or adjustment to the fitting. 4: Do not install any luminaire near a
heat source. 5: Do not exceed the nominal supply voltage or amperage ratings.
6: To avoid injury or damage to the fitting, please ensure that power leads
and screws are secure before connecting the power.
Installation Spacing
Thermal Insulation
HCB=25 mm
SCB=25 mm SCG=50 mm
Power supply
Risk of fire! Required clearance from structural members and building
elements. SCB=25 mm HCB=25 mm MIC=0 mm SCI=0 mm
Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30
info@auralight.com, www.auralight.com
HCB: Height clearance to building element. MIC: Minimum insulation clearance.
SCI: Side clearance to insulation. SCB: Side clearance to building element.
SCG: 50 mm.
SCG=side clearance to auxiliary equipment. CG=control gear.
2024-08-12
I-203
Ceiling cutout reference table.
Downlight diameter (mm) 90 (without ring)
Ceiling Cutout (mm)
68
90 (with ring) 83
190 160-170
228 200-210
IP rating table: Before installation, please check the IP label on the luminaire to choose the right place to install.
IP40
Indoor use only, do not use in wet or damp place.
IP54
Suitable for indoor areas including bathrooms and covered/sheltered areas such as porches.
Dimmer selection table: Before installation, please check the information of driver as below.
Non-dim DALI
Can not be used with any dimmer. Only work with DALI dimming system, dimming range 8-100%
Installation Procedure
Warning 1: Switch off before installation. 2:Switch on only after complete
installation and examination of the circuit. 3: Professional electrician for
installation and maintenance only. 4:Input wire diameter 0.75mm². 5: Product
modification and improper installation are not valid for warranty! 6:Light
source of the luminaire is non-user-replaceable. If it is damaged,
the luminaire shall be destroyed. 7: Risk of overheating or fire if the
clearance distances are compromised!
CAUTION
Risk of electric shock
Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30 info@auralight.com, www.auralight.com
2024-08-12
I-203
Downlight with external driver
1
2
Screw surface mounted installation
1
Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30
info@auralight.com, www.auralight.com
2
2024-08-12
I-203
Screw surface mounted installation
3
4
5
Number of connecting wires depends on driver-option
6
On/Off or DALI.
O
7a
7
8
7b
Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30 info@auralight.com, www.auralight.com
2024-08-12
I-203
Dimensions
48 m m
mm
90 81 67,5
40 Accessories: Surface mounted cylinder
Ø mm
Ø mm
mm
Aura Light AB, Sweden Phone customer service +46 (0)20 32 30 30
info@auralight.com, www.auralight.com