SLOAN CX 8158-1.6 Sensor Closet and Urinal Flushometers Installation Guide

October 30, 2023
SLOAN

SLOAN CX 8158-1.6 Sensor Closet and Urinal Flushometers

SLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-
product

Product Information

The Sloan CX Sensor Closet and Urinal Flushometers are designed to provide efficient and hygienic flushing for commercial restrooms. The product comes in various models depending on the type of fixture used, including:

  • CX 8158-1.6
  • CX 8158-1.28
  • CX 8158-1.1
  • CX 8154-1.6
  • CX 8198-0.5
  • CX 8198-0.25
  • CX 8198-0.125
  • CX 8154-1.28
  • CX 8154-1.1

The product comes with a valve box, mudguard, adjustment tool, activation assembly screws, adjustable tube, outlet connection, elbow, inlet adapter, vacuum breaker assembly, couplings & gaskets, wall bracket, wall plate, sensor assembly, C-bracket, battery pack, AA batteries, screws, Allen key, lock nuts, and instructions.
The rough-in dimensions for the product are determined relative to the spud connection for the fixture being used.

Product Usage Instructions

Prior to Installation

Before installing the Sloan CX Sensor Closet and Urinal Flushometers, ensure that you have all the tools and items required for installation. The provided tools and items include:

  • Valve box
  • Mudguard
  • Adjustment tool
  • Mudguard screws
  • Activation assembly screws
  • Instructions
  • Adjustable tube
  • Outlet connection
  • Elbow
  • Inlet adapter
  • Vacuum breaker assembly
  • Couplings & gaskets

The tools and items required for installation that are not provided include:

  • V651A Kit

Rough-In Closets

The rough-in dimensions for the Sloan CX Sensor Closet and Urinal Flushometers are determined relative to the spud connection for the fixture being used. Refer to the rough-in dimensions below:

Model 8158 Closet Wall Hung Rear Inlet

If the fixture inlet is below rim level, consult floor mount rear inlet rough- in dimensions.

Model 8154 Closet Floor Mount Rear Inlet

If the fixture inlet is above rim level, consult wall hung rear inlet rough-in dimensions.

Rough-In Urinals

Model 8198 Urinal Rear Inlet
Refer to the rough-in dimensions below:

Important Notes

  • The product contains mechanical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
  • Accuracy is important for wall opening dimensions. The valve must be centered horizontally in the opening within 1/8″. For assistance, please consult the rough-in template.
  • There are no warranties that extend beyond the description on the face hereof. In no event is Sloan Valve Company responsible for any consequential damages of any measure whatsoever.

Sensor Closet Flushometers

  • CX 8158-1.6
  • CX 8158-1.28
  • CX 8158-1.1
  • CX 8154-1.6
  • CX 8154-1.28
  • CX 8154-1.1

Sensor Urinal Flushometer

  • CX 8198-0.5
  • CX 8198-0.25
  • CX 8198-0.125

LIMITED WARRANTY

Sloan Valve Company warrants its flushometer to be made of first class materials, free from defects of material or workmanship under
normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three (3) years (one year for special finishes) from the date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts that prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations that purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of batteries.
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSE-QUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

PRIOR TO INSTALLATION

This valve is designed for new construction or where there is easily accessed plumb-ing for the fixture and valve. This valve is designed for a minimum 6-1/2 inch (165 mm) wall space depth. Distance from the center of the valve (inlet or outlet pipe) to the finished surface of the wall can vary from 3-1/4” – 4-1/4” (83 – 108 mm).
Wall plate opening must be 7-1/8″ wide x 8″ tall (181 mm wide x 203 mm tall). Mud plate is provided and must accompany valve for proper installation. Mud plate is removed after wall is finished.

TOOLS AND ITEMS REQUIRED FOR INSTALLATION (PROVIDED)

  • 5/64” hex wrench
  • Wall plate depth guide
  • Adjustment tool

TOOLS AND ITEMS REQUIRED FOR INSTALLATION (NOT PROVIDED)

  • Smooth-jawed wrench (at least 2”)
  • Philips screwdriver
  • threaded sweat solder adapter
  • approximately 15”-18” pipe

ITEMS INCLUDED

VALVE BOXSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig-
\(1\)

  1. Valve Box
  2. Mud Guard
  3. Adjustment tool
  4. Mud Guard Screws
  5. Activation Assembly Screws
  6. Instructions
  7. Adjustable Tube
  8. Outlet Connection
  9. Elbow
  10. Inlet Adapter
  11. Vacuum Breaker Assembly
  12. Couplings & Gaskets

WALL PLATE BOXSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-
fig- \(2\)

  1. Wall Bracket
  2. Wall Plate
  3. Sensor Assembly
  4. C-Bracket
  5. Battery Pack
  6. AA Batteries
  7. Screws
  8. Allen Key
  9. Lock Nuts
  10. Instructions

IMPORTANT:

  • INSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.
  • WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
  • FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.

Sloan’s flushometers are designed to operate with 20 to 80 psi (138 to 552 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED.
Consult fixture manufacturer for minimum pressure requirements. Most high efficiency water closets require a minimum flowing pressure of 25 psi (172 kPa). Many building codes and the ASME A112.19.2 fixture standard list maximum static water pressure as 80 PSI (552 kPa).

ROUGH-IN CLOSETS

Roughin for Sloan CX is determined relative to the spud connection for the fixture being used.SLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-
fig- \(3\) SLOAN-CX-8158-1-6-Sensor-
Closet-and-Urinal-Flushometers-fig- \(3\)

ROUGH-IN URINALSSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-
fig- \(5\)

PARTS OVERVIEW

SLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-
fig- \(6\) SLOAN-CX-8158-1-6-Sensor-
Closet-and-Urinal-Flushometers-fig- \(7\)

NOTE: wall hung closet shown. Consult page 7 for other configuration

INSTALL OPTIONAL SWEAT SOLDER ADAPTER

(ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD)

  1. On a 15”-18” length of pipe (not provided), slide threaded sweat adapter (not provided) onto water supply pipe until end of pipe rests against shoulder of adapter. Sweat solder the adapter to pipe (1″ copper x 1″ NPT fitting)

  2. Remove mud plate from valve and save for later use-DO NOT DISCARD

  3. Insert sweat adapter into 1 1/2” to 1” threaded adapter (provided).

  4. Connect 1 1/2” to 1 “ adapter into top of flushometer (“IN”), Tighten fittings securely into valve body with a fixed jaw wrench.
    NOTE : DO NOT EXERT FORCE ON WALL BOX TO TIGHTEN FLUSHOMETER. USED FIXED JAW WRENCH TO HOLD THE VALVE.

  5. For hardwire use only: remove wall box knock/ cap closest to the conduit connection

  6. Using a sweat union (not supplied), connect valve assembly to water supply pipeSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(11\)

CONFIGURE VACUUM BREAKER AND FLUSH CONNECTION AND CONNECT TO VALVE

  • If needed, trim the bottom of the adjustable tube using grinding-style cut-off tool
    NOTE : would only be needed for certain ADA water closet installations.
    Consult rough-in guide (page 2-3)

  • As needed based on rough-in, pre-bend the adjustable tube to account for the side-to-side misalignment of the water supply pipe relative to fixture spud.
    ATTENTION

    • BEFORE ATTEMPTING TO CUT THE ADJUSTABLE TUBE, WITH THE PLUG INSERTED INTO THE BOTTOM OF THE TUBE TO PREVENT CRIMPING, GRIP THE TUBE OUTSIDE THE CORRUGATED SECTION FIRMLY WITH HANDS (NOT SQUEEZING), FLEX THE TUBE WHILE PUSHING TOGETHER TO SHORTEN THE LENGTH. THE SAME CAN BE APPLIED WHILE PULLING OUTWARD TO LENGTHEN THE ADJUSTABLE TUBE.
      FOR WALL-HUNG REAR SPUD FIXTURES (WATER CLOSETS)
  • Cut F-1 flush connection to length as needed for particular rough-in. Consult rough-in

  • Connect F-1 flush connection and adjustable tube to the elbow using coupling and poly washer. Apply Loctite to tube ends, insert tube ends into elbow, and tighten coupling securely (Do not apply Loctite to coupling threads.SLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(13\)

  • Insert the V-651A vacuum breaker kit into the vacuum breaker casing. Attach to valve hand tight.

  • Attach flush connection to the vacuum breakerSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(14\)

  • For hardwire use only: insert conduit into knock-out on side of wall box and tightly secure. Run transformer wires through the conduit to the wall box.
    NOTE : TRANSFORMER NOT PROVIDED. IT IS VERY IMPORTANT THAT THE OUTPUT VOLTAGE OF THE TRANSFORMER BE 6VAC FOR THE UNIT TO FUNCTION PROPERLY. SLOAN EL-386 OR EL-451 IS RECOMMENDED.

  • Finish wall. Use supplied mudguard to protect the valve during the finishing process.

    • Use two (2) mounting screws, if needed, to hold mudguard to wall box

    • Use the marks on the mudguard to make sure the finished wall is between 3 ¼” and 4 ¼” from the center line of the pipe.
      IMPORTANT

    • Loosen the vacuum breaker to the valve.

    • Partially mount fixture onto carrier bolts.

    • Pull the flush connection forward through wall.

    • Make the spud connection wrench tight.
      NOTE : Space permitting or chase present, spud connection can be made behind the wall.

    • Push the fixture back to the wall. Tighten carrier bolts and complete fixture installation.

    • Re-connect the vacuum breaker to valve.SLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(16\)

FOR FLOOR MOUNT REAR SPUD FIXTURES

  • Cut F-1 flush connection to length as needed for particular rough-in.

    • Consult rough-in
  • Connect F-1 flush connection and adjustable tube to the elbow using coupling and poly washer. Apply Loctite to tube ends, insert tube ends into elbow, and tighten coupling securely (Do not apply Loctite to coupling threads).

  • Insert V-651 vacuum breaker kit into vacuum breaker casing.

    • Attach to valve hand tight.
    • Attach flush connection to vacuum breakerSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(17\)
  • For hardwire use only: insert conduit and tightly secure it to the wall box. Run transformer wires through the conduit to the wall box.
    NOTE : TRANSFORMER NOT PROVIDED. IT IS VERY IMPORTANT THAT THE OUTPUT VOLTAGE OF THE TRANSFORMER BE 6VAC FOR THE UNIT TO FUNCTION PROPERLY. SLOAN EL-386 OR EL-451 IS RECOMMENDED.
    Finish wall. Use supplied mud guard to protect valve during the finishing process.

    • Use two (2) mounting screws, if needed, to hold mudguard to wall box
    • Use the marks on mudguard to make sure the finished wall is between 3 ¼” and 4 ¼” from the center line of the pipe
    • Loosen vacuum breaker to valve.
    • Mount fixture
    • Pull the flush connection forward through wall.
    • Pre-install escutcheon and fittings in the following order
    • Wall trim plateSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(20\)
    • Coupling
    • Friction ring
    • Gasket
    • Escutcheon
    • Connect coupling (2) to spud, wrench tight.
    • Slide wall trim plate against wall.
    • Re-connect the vacuum breaker to valveSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(21\)

IMPORTANT

Wall plate opening must be 7-1/8″ wide x 8″ tall (181 mm wide x 203 mm tall). Valve must be centered horizontally within the opening

FOR REAR SPUD URINALS

  1. If needed, trim the urinal flush tube.

  2. Slide 3/4″ coupling over urinal flush tube. If cutting the tube, thread the adapter first, then cut. After cut, remove the adapter to help chase/clean threads.

  3. Thread F-28 brass flange onto the urinal flush tube.

  4. The amount of thread engagement will depend on rough-in.

  5. Use provided Loctite to secure and seal the F28 flange.

  6. Apply Loctite to tube threads (completely around the tube) where the flange will sit on the tube. Then thread flanges into Loctite.

  7. Ensure Loctite is visible on both sides of the flange. Allow time for Loctite to “set”, approx. 30 minutes. Slide the F2 coupling over the urinal connection tube, and then install the urinal connection tube to the urinal spud and tighten the spud coupling.

  8. Secure urinal flush tube to elbow using 1-1/2” gasket

  9. Finish wall. Use supplied mudguard to protect the valve during the finishing process.

  10. Use two (2) mounting screws, if needed, to hold the mud guard to the wall box.

  11. Use the marks on the mudguard to make sure the finished wall is between 3 1/4″ and 4 1/4″ from the center line of the pipeSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(24\)
    IMPORTANT
    Wall plate opening must be 7-1/8″ wide x 8″ tall (181 mm wide x 203 mm tall).Valve must be centered horizontally within the opening.

  12. Hang urinal on the mounting bracket.

  13. Loosen vacuum breaker to the valve.

  14. Make a spud connection behind the wall.

  15. Re-connect the vacuum breaker to the valve.

INSTALL WALL PLATE ASSEMBLY

SLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-
Flushometers-fig- \(25\) SLOAN-
CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig-
\(26\)

For Hardwire connection use.

  1. Using a wire stripper strip the two wire transformer connection from the conduit.
  2. Insert the wire to the Blue Terminal Block provided with the Sensor Assembly
  3. Tighten the terminal block screws using a flathead screwdriver 0.118” (3 mm) or smaller.
  4. Connect the Blue terminal block to the two pins in the back of the Sensor Assembly.

IMPORTANT: SURGE PROTECTOR BEFORE THE TRANSFORMER IS RECOMMENDEDSLOAN-
CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig-
\(27\)

NOTE

THE SENSOR ASSEMBLY COMES WITH THE BUTTON ALREADY INSTALLED. IN CASE THE BUTTON HAS COME OFF FROM THE SENSOR ASSEMBLY DURING SHIPMENT, INSTALL IT FOLLOWING THE FIGURE BELOW.

  • One EL-386 Transformer (sold separately) serves one (1) CX Closet/ Urinal flushometer.
  • One EL-451 Transformer (sold separately) serves up to (6)CX Closet/ Urinal flushometer with 18 gauge wire within 50 feetSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-Flushometers-fig- \(28\)

INSTALL WALL PLATE ASSEMBLY (CONT.)

  • Assemble C-Bracket to the wall bracket using two (2) 2” long #8-32 screws.
  • Tighten two (2) locking nuts to the screws about ¼” away from tail of the screws.
  • Rotate wall bracket slightly about vertical axis and slide C-Bracket behind the finished wall while holding the top of the wall bracket.
  • Once C-bracket is behind the wall, align top two (2) holes on the bracket to the wall box and secure in place using two (2) 2” long #8-32 screws. Tighten the bottom two (2) screws on the bracket.
  • Make sure the wall bracket is positioned plumb and level before tightening the screws completely

INSTALL BATTERY BOX AND SENSOR ASSEMBLY

The Sloan CX sensor assembly is designed to work with both hardwire and battery as a back-up or only the battery power connectionSLOAN-CX-8158-1-6
-Sensor-Closet-and-Urinal-Flushometers-fig- \(30\)

NOTE
WATER DOES NOT HAVE TO BE TURNED OFF TO REPLACE BATTERIES. USE ALKALINE BATTERIES FOR PROPER UNIT OPERATION

  • Remove battery cover by loosening screw using a Phillips head screwdriver.

  • Install four (4) Alkaline AA-size batteries into the battery box in the orientation noted on the inside the battery box.

  • Reinstall the battery cover and, using a screwdriver, tighten the screw until the battery cover is tightly secure.

  • Insert the Battery Box on the right side of the flushometer as shown

  • Connect Solenoid D-shape connector to sensor assembly
    NOTE : Solenoid can only be installed in one orientation

  • Connect Battery Box D-shape connector to Sensor assembly.
    NOTE : RED LED WILL START BLINKING WHEN POWER IS CONNECTED TO THE SENSOR ASSEMBLY.

  • Mount the Sensor Assembly to the wall bracket.

    • Aligned the four (4) slots on the sensor assembly with the mounting pegs on the wall bracket.
    • Slide the sensor assembly all the way down

SENSOR OPERATION

  • After power is applied, the Sensor Module will perform its Start-up routine for approximately 3 minutes 30 seconds with LED blinking. Step away from the sensor during this time. The sensor will calibrate without the user in the detection area to calibrate the “non-use” enviroment.
    NOTE : It is important to leave the area directly in front of the sensor during calibration (exit stall or stand to the side). Failure to do so may cause the sensor to not operate and require restarting the sensor again until calibration is properly performed. Disconnect power from the sensor for 1 minute before repeating.
    NOTE : A one (1) second long Red LED, followed by one slow Red LED blinking in the Sensor Window indicates the sensor is in the start-up mode. There will be two (2) Red LED pulses (each one (1) second long) in the Sensor Window to indicate the start-up routine is complete.

  • After the start-up routine is complete, in the first ten (10) minutes of operation, a visible Red LED flashes in the Sensor Window of the CX Flushometer when a user is detected.

TEST SENSOR OPERATION

The CX Flushometer has a factory-set sensing range:

  1. Water Closet Models – 22” to 46” (559 mm to 1168 mm)
  2.  Urinal Models – 15” to 34” 381 mm to 864 mm)

Test the sensor by stepping in front of the sensor for 10 seconds.
After 10 seconds step away from the sensor and listen for a “CLICK”
The factory setting should be satisfactory for most installations. If a range adjustment is required, refer to the range adjustment instructions in this installation guide (See page 13).

ADJUST WATER FLOW

  • Flushometer is shipped with the flow control adjustment turned OFF.
  • Disconnect the Flushometer Solenoid connector from the Sensor Assembly. Pull on the end connector to prevent damage to wires.
  • Lift the Sensor Assembly Override Button up to access the activation assembly.
  • Open water flow by turning the activation assembly slowly COUNTERCLOCKWISE using an adjusting tool and a screwdriver or a wrench.
    • There is approximately 1/8-turn (45°) of free spinning as the activation assembly engages the shut-off sleeve between opening and closing the valve.
    • A 1-1/2″ socket or wrench can be attached to the adjustment tool or a screwdriver can be passed through the side holes to provide additional torque.
  • Connect the Flushometer Solenoid connector to the Sensor Assembly.
  • Activate Flushometer by pressing the Override Button.
  • Adjust the Activation Assembly after each flush until the flow rate delivered properly cleanses the fixture (turn CLOCKWISE to lessen flow and COUNTERCLOCKWISE to increase flow).

INSTALL WALL PLATESLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-
Flushometers-fig- \(33\)

  1. Make sure the retaining screw on the bracket is fully tightened clockwise.
  2. Slide Sensor Assembly all the way up.
  3. Align the Wall Plate cut out with the window and Override the Button of the Sensor Assembly and push Wall Plate all the way in.
  4. Make sure the sensor window and button are sitting inside the wall plate cut out. Slide Wall Plate all the way down.
  5. The retaining screw is designed to rest inside the wall plate. Turning the retaining screw counterclockwise using supplied Allen key until it touches the wall plate will lock the plate in place, preventing the plate from sliding upward and being removed.
  6. Make sure Wall Plate doesn’t slide up.

OPERATION

  • A continuous, INVISIBLE light beam is emitted from the Sloan CX Sensor.
  • After the user enters the beam’s effective range, 22 to 46 inches (559 mm to 1168 mm) for closet installations and 15 to 34 inches (381 mm to 864 mm) for urinal installations for ten (10) seconds the flushometer is armed.
  • When the user steps away, the sensor initiates a “one-time” signal that activates the flushing cycle to flush the fixture (1-second delay for urinal, 3 seconds delay for closet). The Circuit automatically resets and is ready for the next user.

RESTART THE SENSOR (ONLY IF NECESSARY)

The Sloan CX Flushometer has a factory-set sensing range:
Water Closet Models – 22” to 46” (559 mm to 1168 mm)
Urinal Models – 15” to 34” (381 mm to 864 mm)
The Factory setting should be satisfactory for most installations. If the range is too short (i.e. not picking up users) or too long (i.e., picking up opposite wall or stall door) the range can be adjusted.
NOTE : WATER DOES NOT HAVE TO BE TURNED OFF TO ADJUST THE RANGE.

  • Make sure to remove all the non-permanent targets in the sensor view area.
  • Push the Override button for 20-30 seconds.
  • The Red LED in the sensor window starts slowly blinking.
  • Release the button after the LED starts slowly blinking and step away.
  • The CX will enter into start-up mode.
  • The setting mode will run for one minute.

NOTE

BASIC SERVICING

  • A. Remove the wall plate.
    Note : water can be shut off without removing the plastic mounting plate. Removal of the plastic mounting plate provides more hand room for servicing the valve and accessing the flush connection.

    • Turn the retaining screw at the bottom of the wall plate using Allen Key clockwise
    • Slide the wall plate up, then pull it out.
  • B. Disconnect the flushometer solenoid connector from the sensor assembly. Pull on end connector to prevent damage to wires.

  • C. Slide sensor assembly up and pull away from the wall to remove. Note: battery pack can remain attached during sensor assembly removal. Disconnecting the battery pack would require recalibration of sensor after servicing.
    D. Reconnect the sensor assembly to the solenoid. Press the override button to relieve pressure. Disconnect solenoid. Pull on the end connector to prevent damage to wires.

  • E. Push in activation assembly until fully seated.

  • F. Squeeze tabs on the Collar and pull out.

  • G. Attach provided screws to activation assembly. Pull to remove the assembly.
    DO NOT TURN THE ASSEMBLY TO AVOID TURING WATER FLOW BACK ON. DO NOT REMOVE OR ADJUST THE SOLENOID.

  • H. Remove the conical spring. Do not discard!

  • I. Remove the piston assembly by pulling it straight out. If unable to grip the piston, remove the screw from the activation assembly and insert it into the center hole of the piston.

  • J. Reinstall or replace the piston. Insert smaller-sized end first until fully seated.

  • K. Reinstall or replace the conical spring, small end first, into the piston.

  • L. Reinstall or replace the activation assembly and press until fully seated.

  • M. Reinstall the orange safety ring securely. The safety ring will spin freely in the valve body when properly installed. NOTE: using screws attached to the activation assembly, pull the activation assembly forward to ensure proper alignment.

  • N. Using the adjustment tool, slowly turn the activation assembly counterclockwise to open flow.

  • O. Adjust flow as described on page 11.

  • P. Install wall plate as described on page 12.

TROUBLESHOOTING

  • Sensor Flashes Continuously Only When User Steps Within Range.

    • Unit in Start-Up mode; no problem. This feature is active for the first ten (10) minutes of operation.
  • The valve Does Not Flush; the Sensor Not Picking Up User.

    • Range too short; increase the range.
    • Verify urinal sensor is not used on a closet valve. Rear of the sensor is marked with model.
    • Restart the sensor by pressing and holding the override button for 25 seconds, then release button and step away for 1 minute.
  • Valve Does Not Flush; the Sensor Picking Up Opposite Wall or Surfaces, or Only Flushes When Someone Walks By.
    Red Light Flashes Continuously for First 10 Minutes Even with No One in Front of the Sensor.

    • Range too long; shorten the range.
    • Verify closet sensor is not used on the urinal valve. The rear of sensor is marked with model.
    • Restart the sensor by pressing and holding the override button for 25 seconds, then release the button and step away for 1 minute.
  • The valve Does Not Flush Even After Adjustment.

    • Ensure the water supply to the valve is turned on.
    • The activation Assembly sleeve is in the closed position. Turn counterclockwise to open water flow. NOTE: there is approximately 1/8-turn (45°) of free spinning as the activation assembly engages the shut-off sleeve between opening and closing the valve.
    • Batteries completely used up; replace batteries.
    • Problem with activation assembly; replace activation assembly.
    • Problem with Sensor Assembly; replace Sensor Assembly.
  • Red Light Blinks Four (4) Times When User Steps Within Range (Battery Only).

  • Batteries are low; replace batteries.

  • Red Light Blinks four (4) Times When User Steps Within Range (Hardwire and Battery).

  • The battery box not connected; connect battery box to sensor assembly.

    • Batteries low; replace batteries.
  • Valve Does Not Shut off.

    • The metering bypass hole in the piston is clogged. Remove the piston O-ring from the groove and wash under clean running water. Replace the piston if cleaning does not correct the problem.

    • The supply line water pressure has dropped and is not sufficient to close the valve. Close Activation Assembly until pressure is restored.
      NOTE: under some conditions, opening the shut-off sleeve can correct the force imbalance and cause the valve close.

    • A piston is damaged. Replace with new proper gpf/Lpf piston.

    • Solenoid latched in open position during valve shipment. Connect the sensor assembly and press the override button. See the “Install battery box and sensor assembly” section on page 10 for additional information.

  • Too much water to Fixture.

    • Activation Assembly not adjusted properly. Readjust Activation Assembly.
    • The piston is damaged. Replace with new proper gpf/Lof piston in. Wrong CX model installed; i.e., 1.6 gpf. model installed on 0.5 gpf/1.9 Lpf or 0.25 gpf/1.0 Lpf urinal fixture. Replace with proper CX model per guide.
  • Not enough water to Fixture.

    • Activation Assembly not adjusted properly. Readjust the Activation Assembly by turning counterclockwise.
    • Wrong CX model installed; i.e. 0.5 gpf. urinal installed on 1.6 gal. closet fixture. Replace with proper CX model.
    • Water supply pressure is inadequate (low). Increase the water supply pressure. Contact the fixture manufacturer for the minimum water supply requirements of the fixture.
  • Chattering noise is heard during flush.

    • Reduce flow pressure by turning Activation Assembly.
    • Air trapped inside the valve and/or supply pipe. Air takes time – both count of flushes and actual duration-to be fully removed.

CARE AND CLEANING

DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean Flushometers that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the Flushometer from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome

VALVE ASSEMBLY GUIDE

NOTE : For a complete list of SLOAN CX REPAIR PARTS, consult Sloan CX Repair Parts & Maintenance GuideSLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-
Flushometers-fig- \(37\)

ACTIVATION ASSEMBLY SELECTION GUIDE

IN ORDER FOR THE WATER CLOSET AND THE URINAL TO PERFORM PROPERLY FOR THEIR INTENDED USE, YOU MUST FOLLOW THESE INSTRUCTIONS:SLOAN-CX-8158-1-6-Sensor-
Closet-and-Urinal-Flushometers-fig- \(38\)

  • A. IDENTIFY YOUR FLUSHOMETER MODEL NO.
  • B. CHECK FOR THE WATER CONSUMPTION LABEL ATTACHED TO THE FLUSHOMETER AND FIXTURE, ENSURING THEY MATCH
  • C. REFER TO SPECIFIC FLUSHOMETER SECTION IN GUIDE FOR APPROPRIATE REPLACEMENT PART NO

FLUSH CONNECTION PARTS

SLOAN-CX-8158-1-6-Sensor-Closet-and-Urinal-
Flushometers-40SLOAN-CX-8158-1-6
-Sensor-Closet-and-Urinal-Flushometers-fig- \(39\)

The information contained in this document is subject to change without notice. Manufactured in the U.S.A by Sloan Valve Company under one or more of the following patents: U.S. Patents. 5,295,655; 5,542,718;
5,558,120; 5,564,460; 5,730,415; 5,865,420; 5,887,848;
5,967,182. Other Patents Pending.
Bak-Chek®, Para-flo®, PERMEX®, Turbo-Flo®

For complete listing of items available for repair, please consult Maintenance and Repair Guide.
Contact Technical Support for assistance.
1.888.756.2614 or 1.888.SLOAN14
Tech Support: 1.888.756.2614 or 1.888.SLOAN14

SLOAN VALVE COMPANY
10500 SEYMOUR AVENUE
FRANKLIN PARK, IL 60131
Phone: 1.800.982.5839 or 1.847.671.4300
Fax : 1.800.447.8329 or 1.847.671.4380 • sloan.com
COPYRIGHT © 2020 SLOAN VALVE COMPANY
Code No: 0816858 – Rev. 5 (02/22

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals