SLOAN 3911565 Royal Concealed Manual Water Closet Flushometer Instruction Manual
- June 4, 2024
- SLOAN
Table of Contents
ROYAL® SOLENOID (LESS SENSOR) FLUSHOMETER
ROYAL 150 ESM-3.5-HW
CODE NUMBER
3911565
DESCRIPTION
3.5 gpf, Rough Brass Finish, Fixture Connection Not Included, Single Flush, Hardwired, Solenoid-Operated with Modular Plug, Royal® Concealed Solenoid (less sensor) Hardwired Water Closet Flushometer.
DETAILS
- Flush Volume: 3.5 gpf (13.2 Lpf)
- Finish: Rough Brass (RB)
- Power Type: Hardwired (HW)
- Valve: Diaphragm
- Valve Body Material: Semi-red Brass
- Fixture Type: Water Closet
- Fixture Connection: Not Included
- Supply Pipe: 1″ (25mm)
FEATURES
- PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass
- Vacuum Breaker
- Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation
- Stop Seat and Vacuum Breaker molded from PERMEX® Rubber Compound for Chloramine Resistance
- OPTIMA® EL-461 Water Resistant (NEMA 4) Infrared Sensor with Indicator Light and 36-Inch Cord with Modular Plug
- User friendly adjustable 2 to 6 second Flush Delay
- Water-Resistant (NEMA 4) Courtesy Flush® Override Button
- Non-Hold-Open Integral Solenoid Operator with 15-Foot Cord and Modular Plug
- Chrome Plated, Surface Mount Sensor Enclosure with Wall Gasket
- 1″ Female I.P.S. Union Outlet
- 1″ I.P.S. Wheel Handle Bak-Chek® Angle Stop
COMPLIANCES & CERTIFICATIONS
(UL Certified, ADA Compliant, UPC Certified, BAA Compliant)
RECOMMENDED SPECIFICATION
Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi- Red Brass. Valve shall be in compliance with the applicable sections of ASSE 1037 and ANSI/ASME 112.19.2.
ELECTRICAL SPECIFICATIONS
- Arming Delay: 16 seconds
- Control Circuit: 24 VAC Input/24 VAC Output/Solid State
- Sensor Range: 0″36″ (0914mm)
- Solenoid Operator: 24 VAC
- Transformers:
Ο 0345154
Ο 0345999
VALVE OPERATING PRESSURE (FLOWING)
15-80 PSI (103-552 kPa). Specific fixtures may require greater minimum flowing pressure – consult manufacturer requirements.
DOWNLOADS
- Sloan Concealed Installation Instructions
- Control Stop Repair and Maintenance Guide
- Flush Connections Flanges Repair and Maintenance Guide
- Tail Piece Repair and Maintenance Guide
- Concealed Flushometers Repair and Maintenance Guide
- Additional Downloads
NOTES
All information contained within this document subject to change without notice.
Looking for other variations of the ROYAL 150 ES product?
View the general spec sheet with all options.
Find a compatible urinal for this flushometer.
Find a compatible water closet for this flushometer.
ROUGH-IN
Sloan 10500 Seymour Ave, Franklin Park, IL 60131
Phone: 800.982.5839 · Fax: 800.447.8329 · sloan.com
Code 3911565 · Downloaded 10/28/21 · 08/03/21 · View Latest Version
References
- Water-Efficient Commercial Bathroom Products | Sloan
- Water-Efficient Commercial Bathroom Products | Sloan
- ROYAL 150 ES | Sloan
- Urinals | Commercial Urinals | Industrial Urinals - Sloan
- Water Closets | Water Closet Toilet | ADA Water Closet - Sloan
- sloan.com/general-spec/926
- sloan.com/spec-sheet/3911565
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>