Specifications

  • Item Number: 5336455
  • Model Number: 82411

Package Contents

  • A: Canopy Mounting Bracket
  • B: Threaded Nipple
  • C: Hex Nut
  • D: Socket Upper Coupling
  • E: Threaded Pipe
  • F: Screw Collar Ring
  • G: Screw Collar Loop
  • H: Center Pipe
  • I: Chain
  • J: Check Ring
  • K: Fixture Loop
  • L: Glass Shade (Qty: 5)
  • M: Socket Ring (Qty: 3)
  • N: Socket Base Cup (Qty: 5)
  • O: Cape
  • P: Lower Coupling
  • Q: Small Threaded Nipple
  • A: Cup
  • S: Small Hex Nut
  • T: Lock Washer

Hardware Contents

  • AA: Wire Connector (Qty: 3)
  • BB: Short Machine Screw (Qty: 2)

Safety Information

Please read and understand this entire manual before attempting to assemble, operate, or install the product.
This product contains chemicals known to the State of Californiato cause cancer, birth defects, or other reproductive harm. For more information, go to http://www.P65Warnings.ca.gov
Do not modify the product, take any parts out, or use any parts that are worn out or broken. Failure to obey this instruction could invalidate ETL listing and/or CSA certification of this fixture.

Product Usage Instructions

Preparation

  • Before beginning assembly of the product, make sure all parts are present. Compare parts with the package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.

  • Estimated assembly time: 30 minutes to 1 hour

  • Tools Required for Assembly (not included): Phillips screwdriver, flathead screwdriver, wire strippers, electrical tape, ladder, safety glasses, pliers (2).

Assembly Instructions

  1. Unfold fixture arms so they resemble a 5-pointed star.
  2. Thread the short end of the small threaded nipple (S) into the lower coupling (R) until the preinstalled hex nut is flush against the lower coupling (R). Tighten the small threaded nipple (S) to secure. Pass the cup (T) over the small threaded nipple (S), and position the fixture arms so that they seat into the slots in the cup (T). Pass the lock washer (V) over the threads protruding fromthe cup (T), then thread the small hex nut (U) onto the threads. Tighten to secure. Thread the cap (Q) onto the threads. Tighten to secure.
  3. Screw the threaded pipe (G) to the upper coupling (F). Pass the center pipe (J) over the threaded pipe (G). Place the check ring(L) on the center pipe (J) and secure by screwing the fixture loop (M) to the threaded pipe (G). Note that the electrical cable will need to be pulled through the individual parts as they are installed.
  4. Position the threaded nipple (C) in the mounting bracket (B) so that, when mounted, it aligns with the canopy. Note that the canopy is only needed to determine the position of the threaded nipple and screw collar loop. It will be installed later.
  5. Once the proper position of the threaded nipple (C) and mounting bracket (B) has been determined, secure them with hex nuts (D). The hex nuts should be tightened 1/4 inch into the threaded nipple (C) and mounting bracket (B).
  6. Connect the mounting bracket (B) to the outlet box (not included) with short machine screws (BB).

FAQ

  • Q: What should I do if I am missing a part or if a part is damaged?
    A: If any part is missing or damaged, do not attempt to assemble the product. Please contact our customer service department at 1-800-554-6504 for assistance.

  • Q: What tools do I need for assembly?
    A: The tools required for assembly are Phillips screwdriver, flathead screwdriver, wire strippers, electrical tape, ladder, safety glasses, and pliers (2).

ATTACH YOUR RECEIPT HERE
Serial Number Purchase Date
Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-554-6504, 8 a.m. – 4:30 p.m, EST, Monday – Friday. kichler.com/customer-care/contact-us

PACKAGE CONTENTS

KICHLER-82411-5-Light-Chandelier-fig-
\(1\)

PART DESCRIPTION                     QTY

A| Canopy| 1
B| Mounting Bracket| 1
C| Threaded Nipple| 1
D| Hex Nut| 3
E| Socket| 5
F| Upper Coupling| 1
G| Threaded Pipe| 1
H| Screw Collar Ring| 1
I| Screw Collar Loop| 1
J| Center Pipe| 1
K| Chain| 1
PART DESCRIPTION                    QTY

L| Check Ring| 1
M| Fixture Loop| 1
N| Glass Shade| 5
O| Socket Ring| 5
P| Socket Base Cup| 5
Q| Cap| 1
R| Lower Coupling| 1
S| Small Threaded Nipple| 1
T| Cup| 1
U| Small Hex Nut| 1
V| Lock Washer| 1

HARDWARE CONTENTS

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product.

CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.

WARNING:
This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.

  • Do not use bulbs with wattage greater than specified on this fixture.
  • California Proposition 65

WARNING : This product can expose you to chemicals including lead, which is known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information, go to http://www.P65Warnings.ca.gov

CAUTION

  • If you have any doubts about how to install this lighting fixture, or if the fixture fails to operate completely, please contact a licensed electrical contractor.
  • All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to obey this instruction could invalidate ETL listing and/or C.S.A. certification of this fixture.

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.

Estimated assembly time: 30 minutes to 1 hour
Tools Required for Assembly (not included): Phillips screwdriver, flathead screwdriver, wire strippers, electrical tape, ladder, safety glasses, pliers (2).

ASSEMBLY INSTRUCTIONS

  1. Unfold fixture arms so they resemble a 5-pointed star.KICHLER-82411-5-Light-Chandelier-fig- \(3\)

  2. Thread short end of small threaded nipple (S) 2 into lower coupling (R) until the preinstalled hex nut is flush against lower coupling (R). Tighten the small threaded nipple (S) to secure.
    Pass cup (T) over small threaded nipple (S), and position fixture arms so that they seat into the slots in cup (T).
    Pass lock washer (V) over threads protruding from cup (T), then thread small hex nut (U) onto threads. Tighten to secure. Thread cap (Q) onto threads. Tighten to secureKICHLER-82411-5-Light-Chandelier-fig-
\(4\)

  3. Screw threaded pipe (G) to the upper coupling (F). 3 Pass center pipe (J) over threaded pipe (G). Place check ring (L) on center pipe (J) and secure byscrewing fixture loop (M) to threaded pipe (G).
    NOTE : The electrical cable will need to get pulled through the individual parts as they are installed.KICHLER-82411-5-Light-Chandelier-fig-
\(5\)

  4. Position threaded nipple (C) in mounting bracket (B) so that, when mounted:

  5. The threaded nipple (C) will protrude a minimum of 1/4 inch beyond the raised center portion of the bracket (B).

  6. The threaded nipple (C) height should be positioned so that 1/2 the exterior threads of the screw collar loop (I) will extend past the canopy (A), when it is mounted.
    NOTE : A canopy is only needed to determine the position of the threaded nipple and screw collar loop. It will be installed later

  7. Once the proper position of the threaded nipple (C) and mounting bracket (B) has been determined, secure with hex nuts (D) as follows:

  8. Screw one hex nut (D) onto the threaded nipple (C) and tighten against the raised portion of the mounting bracket (B).

  9. Screw another hex nut (D) onto the threaded nipple (C) and tighten it against the flat portion of the mounting bracket (B).

  10. Screw the remaining hex nut (D) onto the threaded nipple (C) and tighten it against the screw collar loop (I).

  11. Connect mounting bracket (B) to the outlet box (not included) with short machine screws (BB).KICHLER-82411-5-Light-Chandelier-fig- \(8\)
    Hardware Used

  12. To open chain links:
    Locate the split in the chain link (K) you’re removing. Put one pair of pliers (not included) on each side of the split and rotate the pliers in opposite directions to open the link’s split. The open link should be shaped like the letter “C”. Do not twist the ends of the link sideways so that the open link cannot lay flat

  13. Thread chain (K) through screw collar ring (H) and canopy (A). Attach one end to the screw collar loop (I) and the other end to the fixture loop (M). Then, weave the fixture electrical and ground wires through every other chain link and pass through the threaded nipple (C) into the outlet box. Lower the screwcollar ring (H) and canopy (A) over the chain (K).
    NOTE : Add or remove chain links once the desired length is established. Trim extra cabling leaving six inches of extra wire protruding from the screw collar loop and threaded nipple.
    CAUTION : To avoid damage from falling, make sure the open chain links are fully closed once assembled

  14. Wire connection guide:
    Ground wire:KICHLER-82411-5-Light-Chandelier-fig-
\(12\)

  15. For installation in the United States: Wrap ground wire from outlet box around ground screw preassembled on mounting bracket (B) no less than 2 in. from wire end. Tighten the ground screw. If the fixture is supplied with a ground wire, connect to outlet ground wire with a wire connector (AA).

  16. For installation in Canada: If the fixture is supplied with ground wire, wrap ground wire around the ground screw on the mounting bracket (B). Tighten ground screw. Connect fixture ground wire to outlet ground wire with a wire connector (AA). Supply wires:

  17. Connect the Neutral (White) supply wire from the outlet box to the Neutral fixture wire (White or Parallel Cord “D” shaped and ribbed).

  18. Connect the Hot (Black) supply wire from the outlet box to the Hot fixture wire (Black or Parallel Cord round and smooth).

  19. Pass canopy (A) over the screw collar loop (I). Attach screw collar ring (H) to screw collar loop (I) to secure canopy (A).
    NOTE : Make sure all wires are inside of canopy (A) and do not get pinched between canopy (A) and mounting bracket (B), or canopy (A) and ceiling
    NOTE:
    Fixture wires will either be:KICHLER-82411-5-Light-Chandelier-fig-
\(13\)

  20. Black and White.

  21. Parallel Cord SPT-1 lamp wire with one round smooth wire and one “D” shaped ribbed wire.

  22. Carefully slip small opening in glass shade (N) over socket (E) until it is seated in socket base cup (P). While holding glass shade (N) in place, thread socket ring (O) onto threads of socket (E). Tighten socket ring (O) to secure glass shade (N) in place. DO NOT OVER-TIGHTEN. Repeat for remaining glass shades (N).

  23. Insert 60-watt max E26 medium base bulb or LED equivalent (not included) into socket (E). Repeat for remaining sockets (E).

CARE AND MAINTENANCE

  • Always be certain that electric current is turned o before cleaning this item.
  • Use a soft, moist cloth with mild non-abrasive soap to clean fixture. Never use glass cleaner on fixture, as it will damage the metal finish.
  • All glass shades may be washed in a towel-lined sink with warm water and mild soap. Do not wash shades in an automatic dishwasher.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Fixture does not light. 1.  Fixture may be wired incorrectly.

2.   Worn or broken bulb.

| 1.  Check wiring.

2.   Replace bulb.

Distributed by: Kichler Lighting LLC 30455 Solon Rd Solon, OH 44139Printed in China