FIXTURE DIAGRAM
WALL MOUNTING
PARTS LIST
SEMI-FLUSH MOUNTING
STEM MOUNTING
[A] Mounting Strap
[B] Outlet Box (not supplied)
[C] Strap Mounting Screw (Qty. 2)
[D] Fixture Mounting Screw (Qty. 2)
[E] Canopy
[F] Knob (Qty. 2)
[G] Small Lock Washer (Qty. 2)[H] Glass Shade
[I] Main Body
[J] Short Threaded Tube
[K] Rubber Washer
[L] 90 Degree Coupling
[M] End Cap
[N] 3.5” Tube
[O] Long Threaded Tube
[P] Spacer
[Q] Bushing (installed in end of Long Threaded Tube)
[R] Hex Nut (attached to Long Threaded Tube inside Canopy)
[S] Large Lock Washer (attached to Long Threaded Tube inside Canopy)
[T] Short (3/4”)
Threaded Tube (included in parts bag)
[U] Medium (1-3/8”) Threaded Tube (included in parts bag)
[V] 1” Coupling (included in parts bag)
W] Swivel (included in parts bag)
[X] Socket
[Y] Socket Base Cup
SOLD SEPARATELY (FOR STEM MOUNTING):
[Z] Stems (2-12”, 2-6” with Short Threaded Tubes
[AA] pre-installed)
[AA] Short Threaded Tubes (preinstalled to Stems [Z])
CAUTIONS
CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fuse box before
starting and during the installation.
WARNING:
- This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
CLEANING:
- Always be certain that electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
INSTALLATION OPTIONS
PLEASE NOTE, THIS FIXTURE CAN BE INSTALLED AS A:
- WALL MOUNTED FIXTURE (SEE “INSTALLATION INSTRUCTIONS”)
- SEMI-FLUSH MOUNTED FIXTURE (SEE “ADDITIONAL WAYS TO INSTALL”)
- STEM MOUNTED FIXTURE (SEE “ADDITIONAL WAYS TO INSTALL”)
NOTE: STEM MOUNTED INSTALLATION REQUIRES ADDITIONAL PURCHASE OF A KICHLER STANDARD STEM SET.
INSTALLATION INSTRUCTIONS
WALL MOUNTING INSTRUCTIONS:
-
Find the appropriate threaded holes on mounting strap [A] that align with hole distance in canopy [E]. Thread fixture mounting screws[D] into threaded holes in mounting strap, starting from the outlet box[B] side.
-
Attach the mounting strap to the outlet box using the strap mounting screws [C].
-
Cut fixture wires a MINIMUM of 6 inches from back edge of canopy.
-
Grounding instructions: (See Illus. a or b).
a. On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
b. On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires. -
Make wire connections. Reference chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to| Connect White Supply Wire to:
---|---
Black| White
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
*Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|
Neutral Wire -
Push canopy to wall, carefully passing fixture mounting screws [D] through small holes in canopy [E].
NOTE: Fixture can be mounted with socket(s) facing upward or downward.
NOTE: Make sure all wires are inside canopy and do not get pinched between canopy and mounting strap or canopy and wall. -
lip small lock washers [G] over fixture mounting screw threads protruding through small holes in canopy (2 places).
-
Thread knobs [F] onto fixture mounting screw threads protruding through small holes in canopy (2 places). Tighten knobs to secure fixture to wall.
-
Insert recommended bulb (not included).
-
Carefully pass glass shade [H] up over bulb and socket [X], and into socket base cup [Y]. Hold the main body[I] in place with one hand, while gently pressing the glass shade against the socket base cup, and turning the glass shade clockwise into the socket base cup until it is locked in place to secure. DO NOT OVER-TIGHTEN.
ADDITIONAL WAYS TO INSTALL’
SEMI-FLUSH MOUNTING INSTRUCTIONS:
NOTE: To install fixture in “semi-flush mounted” or “stem mounted” configurations, fixture must first be disassembled from the default “wall mounted” configuration by following steps 1-7 below (see Fig. 1: DISASSEMBLY OF WALL MOUNTED **FIXTURE).
**
SEMI-FLUSH MOUNTING
STEM MOUNTING
-
Remove bushing [Q], hex nut [R], and large lock washer [S] from end of long threaded tube [O] inside canopy [E]. Slide bushing, hex nut, and large lock washer off fixture wires and retain for use in later steps.
-
Remove canopy [E] , spacer [P], and 3.5” tube [N] from long threaded tube [O]. Slide canopy, spacer, and 3.5” tube off fixture wires. Retain canopy and spacer for use in later steps. Discard 3.5” tube.
-
Unscrew long threaded tube [O] from 90 degree coupling [L] and slide long threaded tube off fixture wires. Discard long threaded tube.
-
Unscrew end cap [M] from top of 90 degree coupling [L] and pull fixture wires out of top of 90 degree coupling. Discard end cap.
-
Unscrew 90 degree coupling [L] from top of main body [I]. Slide 90 degree coupling off fixture wires and discard.
-
Remove rubber washer [K] from top of main body [I]. Slide rubber washer off fixture wires and discard.
-
Unscrew short threaded tube [J] from top of main body [I]. Slide short threaded tube off fixture wires and discard.
-
Pass fixture wires from main body [I] through medium (1-3/8”) threaded tube [U]. Screw medium (1-3/8”) threaded tube into top of main body [I].
-
Pass fixture wires through spacer[P] and slip spacer over threads of medium (1-3/8”) threaded tube [U] protruding from top of main body [I].
-
Pass fixture wires through 1” coupling [V] and screw 1” coupling onto threads of medium (1-3/8”) threaded tube [U] protruding from top of spacer [P].
-
Pass fixture wires through short (3/4”) threaded tube [T] and screw short (3/4”) threaded tube into 1” coupling [V].
NOTE: If ceiling is not level, install swivel [W] in place of the short (3/4”) threaded tube [T], by screwing pivoting end of swivel into 1” coupling [V].
NOTE: If swivel option is chosen, swivel should be installed with pivoting end facing downward as shown. -
Pass fixture wires through bushing [Q] and press bushing into free end of short (3/4”) threaded tube [T] (or optional swivel [W]).
-
Pass fixture wires through center hole in canopy [E] and carefully lower canopy down over threads of short (3/4”) threaded tube [T] (or optional swivel [W]). Canopy should rest on top of 1” coupling [V] (or optional swivel [W]).
-
Pass fixture wires through large lock washer [S] and slip large lock washer over threads protruding into canopy [E].
-
Pass fixture wires through hex nut[R] and screw hex nut onto threads protruding into canopy [E]. Tighten hex nut to secure canopy.
-
Follow steps 1-5 for WALL MOUNTING INSTRUCTIONS.
-
Raise canopy to ceiling, carefully passing fixture mounting screws [D ] through small holes in canopy [E].
NOTE: Make sure all wires are inside canopy and do not get pinched between canopy and mounting strap or canopy and ceiling. -
While holding canopy in place flush against ceiling, slip small lock washers [G] over fixture mounting screw threads protruding through small holes in canopy (2 places), then thread knobs [F] onto fixture mounting screw threads protruding through small holes in canopy (2 places). Tighten knobs to secure fixture to ceiling.
-
Insert recommended bulb (not included).
-
Carefully pass glass shade [H] up over bulb and socket [X], and into socket base cup [Y]. Hold the main body [I] in place with one hand, while gently pressing the glass shade against the socket base cup, and turning the glass shade clockwise into the socket base cup until it is locked in place to secure. DO NOT OVER-TIGHTEN.
STEM MOUNTING INSTRUCTIONS (REQUIRES ADDITIONAL PURCHASE OF A KICHLER STANDARD STEM SET #2999XX. CONTACT YOUR KICHLER DEALER OR KICHLER CUSTOMER CARE: kichler.com/customer-care/contact-us):
-
Follow steps 1-10 for SEMI-FLUSH MOUNTING INSTRUCTIONS.
-
Pass fixture wires through desired number of short threaded tubes [AA] and stems [Z]. Screw stems together using short threaded tubes.
NOTE: Thread locking compound must be applied to all stem threads as noted with symbol (4) to prevent accidental rotation of fixture during cleaning, re-lamping, etc. -
Screw first stem into 1” coupling [V].
-
Pass fixture wires from last stem through swivel [W]. Screw pivoting end of swivel into end of last stem.
NOTE: Swivel should be installed with pivoting end facing downward as shown. -
Pass fixture wires through bushing [Q] and press bushing into free end of swivel [W].
-
Pass fixture wires through center hole in canopy [E] and carefully lower canopy down over threads protruding from top end of swivel [W]. Canopy should rest on top end of swivel.
-
Follow steps 14-20 for SEMI-FLUSH MOUNTING INSTRUCTIONS.
For warranty information please visit: kichler.com/warranty