SOLAX POWER X1 AC Series AC Coupled 3.6kW Charger Installation Guide
- June 15, 2024
- SOLAX POWER
Table of Contents
Quick Installation Guide
X1-AC Series 3.0KW-5.0KW
Inverter Installation
Packing List
Serial Port Connections
Ports Definition
Communication interface bewteen the inverter and Meter/Battery/DRM/485 are as
follows with RJ45 connectors which should be inserted corresponing port in the
inverter.
Port
PIN| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---
CT| CT+| X| X| CT-| X| X| X| X
Meter| X| X| X| X| X| GND| 485A| 485B
BIVS| NTC| GND| GND| BMS_CANH| BMS_CANH| GND| BIVS_485A| BMS_485B
DRM| DRM1/5| DRM2/6| DRM3/7| DRM4/8| +3.3V| DRVO| GND| GND
485| COMO| Shut Down| GND| 485A| 485B| X| X| X
- Prepare RJ45 connector and the communication cable, following the PIN deder bellow, then insert the cable into the corresponding CT/Meter or BMS or DRM port of the inverter, and tighten the waterproof connector.
AC and Earth Connection
- Slide the cable nut and back shell onto the cable.
- Insert the tripped end of three wires into holes in the female insert, then tighten(torque:0.8±0.1Nm) each screw.
- Screw down the threaded sleeve with pressure screw.
- Screw down the pressure screw.(torque:3±0.3Nm)
- Connect the AC plug to the inverter.
- Screw the ground screw(on the inverter) with Φ4 hexagon wrench (torque:1.5±0.2Nm)
Start Guide
-
Select the language according to the need.
-
Set date time based on the local time.
-
The user can set the safety standard here according to different countries and grid tied standards.
-
This function allows the inverter able to control energy exported to the grid.
– The user value setting by installer must be less than the factory value. -
There are 4 work modes for choice, self use, back up mode, feed in priority and force time use.
– Please refer to the Page 43 of the user manual. -
RF control is an optional function (being developed) which can control designated load intelligently by consuming the surplus energy when feed in power reaches certain value.
– The function can only be achieved with Solax product “smart plug”.
– For specific operation, please refer to “Smart Plug user manual”
Battery Connection and Overview
Note:
If you use the lead-acid battery, please refer to corresponding quick
installation manual.Overview for connection.
– After checking all connections is correct, turn on the external battery
switch.
– Turn on the grid switch.
– Press the “Enter” key for e seconds to open the switch. The LED will be
green and the screen will display the main interface.
Firmware Upgrading
- Make sure the battery switch and the ACswitch is disconnected with grid. Unscrew the waterproof lid of Upgrade port by straight screwdriver as the picture shows.
- Insert U-disk with upgrade package* into the USB port on the bottom of the inverter. Then turn on AC switch the battery switch, the LCD will show picture as below.
- Press “OK” to confirm to update. After the upgrade is complete, please remember to turn off the battery switch and the AC switch , then pull off the U-disk, screw the waterproof lid.
- Please contact our service support to get the update package,and extract it into your Udisk.Do not modify the program file name ! Or it may cause the inverter not work anymore!