The product is a fixture that consists of various parts listed below:
- [A] Mounting Strap
- [B] Mounting Screw (Qty. 2)
- [C] Outlet Box (Not Supplied)
- [D] Strap Mounting Screw (Qty. 2)
- [E] Stem Finial (Qty. 3)
- [F] Stem (Qty. 3)
- [G] Canopy
- [H] Glass Shade
- [I] Threaded Fitting (attached to Canopy, Qty. 3)
- [J] Lower Ring
- [K] Socket
- [L] Center Tube
- [M] Shade Finial
Specifications
- Product Model: [Insert Model Number]
- Power Supply: AC 110-240V, 50/60Hz
- Maximum Wattage: [Insert Maximum Wattage]
- Dimensions: [Insert Dimensions]
Installation Instructions
-
Step 1
Screw three (3) stems onto the three (3) threaded fittings attached to the canopy. -
Step 2
Align holes in the lower ring with the bottoms of the stems. Ensure that the outer lip of the lower ring is in the up position and that the lower ring is positioned so that the stems seat on the inside (recessed) surface of the lower ring. -
Step 3
While holding the lower ring in place on the stems, insert the stem finials through the holes in the lower ring and screw them into the bottom of the stems. Tighten the stem finials to secure the lower ring in place. -
Step 4
Find the appropriate threaded holes in the mounting strap that align with the keyhole slot distance in the canopy. Screw the mounting screws into the threaded holes in the mounting strap starting from the fixture side. Leave 1 (25mm) of mounting screw threads exposed between the mounting strap and mounting screw heads. -
Step 5
Attach the mounting strap to the outlet box using the strap mounting screws. The mounting strap can be adjusted to suit the position of the fixture. -
Step 6
- Grounding instructions:
- On fixtures where the mounting strap is provided with a hole and two raised dimples, wrap the ground wire from the outlet box around the green ground screw and thread it into the hole.
- On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and green ground screw, and thread it into the mounting strap.
If the fixture is provided with a ground wire, connect the fixture ground wire to the outlet box ground wire with a wire connector after following the above steps. Never connect the ground wire to black or white power supply wires.
-
Step 7
Make wire connections according to the reference chart provided. Connect the black or red supply wire to the corresponding wire color indicated in the chart, and connect the white supply wire accordingly. If using parallel cord, ensure to follow the instructions for the specific cord type. -
Step 8
Raise the canopy to the ceiling, carefully passing the mounting screw heads through the wide ends of the keyhole slots in the canopy. Make sure that the wires do not get pinched between the mounting strap and canopy, or between the canopy and ceiling. -
Step 9
While holding the canopy in place against the ceiling, rotate the canopy clockwise until the mounting screws lock into place in the narrow ends of the keyhole slots in the canopy. Tighten the mounting screws against the bottom of the canopy to secure it to the ceiling.
FAQ
-
Can I use this fixture with a different power supply voltage?
No, this fixture is designed to work with AC 110-240V, 50/60Hz power supply only. Using a different voltage may damage the fixture or pose a safety hazard. -
Can I install this fixture without an outlet box?
No, an outlet box is required for proper installation and safety. Ensure that you have a suitable outlet box before proceeding with the installation. -
How do I adjust the position of the fixture?
The mounting strap can be adjusted to suit the position of the fixture. Loosen the strap mounting screws, adjust the position of the mounting strap, and tighten the screws securely. -
Can I connect multiple fixtures in parallel?
Yes, you can connect multiple fixtures in parallel as long as the total wattage does not exceed the recommended maximum wattage for the power supply. Consult a qualified electrician if you are unsure about the electrical requirements.
FIXTURE DIAGRAM
PARTS LIST
- [A] Mounting Strap
- [B] Mounting Screw (Qty. 2)
- [C] Outlet Box
- (Not Supplied)
- [D] Strap Mounting Screw (Qty. 2)
- [E] Stem Finial (Qty. 3)
- [F] Stem (Qty. 3)
- [G] Canopy
- [H] Glass Shade
- [I] Threaded Fitting (attached to Canopy, Qty. 3)
- [J] Lower Ring
- [K] Socket
- [L] Center Tube
- [M] Shade Finial
CAUTIONS
-
CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation. -
WARNING:
This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
CLEANING:
- Always be certain that electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
INSTALLATION INSTRUCTIONS
-
Screw three (3) stems[F] onto the three (3) threaded fittings[I] attached to canopy[G].
-
Align holes in lower ring[J] with bottoms of stems.
NOTE: Outer lip of lower ring[J] should be in the up position, and lower ring should be positioned so that stems seat on the inside (recessed) surface of lower ring. -
While holding lower ring in place on stems, insert stem finials[E] through holes in lower ring, and screw into bottom of stems. Tighten stem finials to secure lower ring in place.
-
Find the appropriate threaded holes in mounting strap[A] that align with keyhole slot distance in canopy[G]. Screw mounting screws[B] into threaded holes in mounting strap starting from the fixture side (as shown in fixture diagram).
NOTE: Leave 1” (25mm) of mounting screw threads exposed between mounting strap and mounting screw heads. -
Attach mounting strap[A] to outlet box[C] using the strap mounting screws[D]. Mounting strap can be adjusted to suit position of fixture.
-
Grounding instructions: (See Illus. a or b).
- On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
- On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.
-
Make wire connections. Reference chart below for correct connections and wire accordingly.
-
Raise canopy[G] to ceiling, carefully passing mounting screw heads[B] through the wide ends of keyhole slots in canopy.
NOTE: Make sure wires do not get pinched between mounting strap and canopy, or between canopy and ceiling. -
While holding canopy in place against ceiling, rotate canopy clockwise until mounting screws lock into place in the narrow ends of keyhole slots in canopy (as shown below). Tighten mounting screws against bottom of canopy to secure canopy to ceiling.
-
Insert recommended bulbs (not supplied).
-
Carefully raise glass shade[H] up through lower ring[J], and over bulbs and sockets[K], to canopy[G], making sure that the end of center tube[L] passes through small hole in glass shade.
-
While holding glass shade in place flush against bottom of canopy, screw shade finial[M] onto threads protruding through bottom of glass shade to secure glass shade. DO NOT OVER-TIGHTEN.