KICHLER 52586CPZ Albers Flush Mount Ceiling Light Instruction Manual
- June 15, 2024
- KICHLER
Table of Contents
KICHLER 52586CPZ Albers Flush Mount Ceiling Light
Product Information
Specifications
- Mounting Strap [A]
- Mounting Screw (Qty. 2) [B]
- Outlet Box (Not Supplied) [C]
- Strap Mounting Screw (Qty. 2) [D]
- Lock Washer (Qty. 2) [E]
- Knob (Qty. 2) [F]
- Canopy [G]
- Glass Shade [H]
- Socket [I]
Product Usage Instructions
Installation
Find the appropriate threaded holes on the mounting strap [A] that align with the hole distance in the canopy [G]. Screw the mounting screws [B] into the threaded holes, starting from the outlet box side.
Attach the mounting strap [A] to the outlet box [C] using the strap mounting screws [D]. The mounting strap can be adjusted to suit the position of the fixture.
Grounding instructions:
a. On fixtures where the mounting strap is provided with a hole and two raised dimples, wrap the ground wire from the outlet box around the green ground screw and thread it into the hole.
b. On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and green ground screw, and thread it into the mounting strap.
If the fixture is provided with a ground wire, connect the fixture ground wire to the outlet box ground wire with a wire connector after following the above steps. Never connect the ground wire to black or white power supply wires.
Wire Connections
Make wire connections according to the chart below:
Connect Black or Red Supply Wire to: | Connect White Supply Wire to: |
---|---|
Black | White |
Parallel cord (round & smooth) | Parallel cord (square & ridged) |
Clear, Brown, Gold or Black without Tracer | Clear, Brown, Gold or Black with |
Tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other
than green) with silver conductor
*Note: When parallel wire (SPT 1 & SPT 2) is used, the neutral wire is square-shaped or ridged, and the other wire will be round in shape or smooth.
Raise the canopy [G] to the ceiling, carefully passing the mounting screws [B] through the mounting screw holes in the canopy.
NOTE: Make sure wires do not get pinched between the mounting strap and canopy, or canopy and ceiling.
While holding the canopy in place, use lock washers [E] and knobs [F] to secure the canopy to the ceiling. Tighten to secure.
Bulb and Glass Shade Installation
Insert the recommended bulb (not supplied) into the socket [I].
Carefully raise the glass shade [H] up to the fixture. Pass the opening in the glass shade over the bulb and socket [I]. Carefully raise and turn the glass shade clockwise into the canopy [G] until it is locked in place to secure. DO NOT OVER-TIGHTEN.
FAQ (Frequently Asked Questions)
Q: Where can I find warranty information for the product?
A: For warranty information, please visit kichler.com/warranty.
FIXTURE DIAGRAM
PARTS LIST
- [A] Mounting Strap
- [B] Mounting Screw (Qty. 2)
- [C] Outlet Box (Not Supplied)
- [D] Strap Mounting Screw (Qty. 2)
- [E] Lock Washer (Qty. 2)
- [F] Knob (Qty. 2)
- [G] Canopy
- [H] Glass Shade
- [I] Socket
CAUTIONS
CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before
starting and during the installation.
WARNING:
- This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
CLEANING
- Always be certain that electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
INSTALLATION INSTRUCTIONS
- Find the appropriate threaded holes on mounting strap[A] that align with hole distance in canopy[G]. Screw mounting screws[B] into threaded holes, starting from the outlet box side.
- Attach mounting strap[A] to outlet box[C] using the strap mounting screws[D]. Mounting strap can be adjusted to suit position of fixture.
- Grounding instructions: (See Illus. a or b).
- a. On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
- b. On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.
- Make wire connections. Reference chart below for correct connectionsand wire accordingly.
-
Raise canopy[G] to ceiling, carefully passing mounting screws[B] through mounting screw holes in canopy.
NOTE: Make sure wires do not get pinched between mounting strap and canopy, or canopy and ceiling. -
While holding canopy in place, use lock washers[E] and knobs[F] to secure canopy to ceiling. Tighten to secure.
-
Insert recommended bulb (not supplied).
-
Carefully raise glass shade[H] up to the fixture. Pass the opening in the glass shade over bulb and socket[I]. Carefully raise and turn the glass shade clockwise into the canopy[G] until it is locked in place to secure.
-
DO NOT OVER-TIGHTEN.
For warranty information please visit: kichler.com/warranty
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>