Product Information

Cautions

WARNING: This fixture is intended for installation by the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.

DIMMING: This LED fixture is compatible with most standard incandescent dimmers, LED dimmers, and electronic low-voltage dimmers. For optimal performance, an electronic low-voltage dimmer should be used. See kichler.com/dimming for a list of compatible dimmers. Products may damage the finish.

FCC Information: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is

Product Usage Instructions

Installation Instructions

  1. Remove mounting plate[B] from canopy[C] by unscrewing four (4) countersunk mounting screws[D] from canopy: two (2) screws on the front of the canopy, two (2) screws on the back of the canopy. Retain screws for re-attaching the canopy to the mounting plate.
  2. Attach mounting plate[B] to outlet box[A] using the plate mounting screws[E]. The mounting plate can be adjusted to suit the position of the fixture.
  3. Using the mounting plate as a template, mark the positions for the two (2) drywall anchors[H], one on each end of the mounting plate. Unscrew the plate mounting screws and remove the plate mounting screws and mounting plate.
  4. Drill 5mm (3/16) holes in the ceiling where marked and insert the two (2) drywall anchors[H].
  5. Attach the mounting plate[B] to the outlet box[A] using the plate mounting screws[E]. Secure the mounting plate to the ceiling by screwing the two (2) drywall mounting screws[I] through the drywall mounting screw holes in the mounting plate and into the drywall anchors.
  6. Adjust each support cable[G] to the desired length. To shorten the cable, push up the cable at the cable strain relief[F] attached to the canopy and push the cable into the canopy. To lengthen the cable, push up on the cable strain relief and gently pull down on the cable to the desired length.
  7. If there is a safety cable attached to the canopy[C], attach the other end of the safety cable to the mounting plate[B] by hooking it into a loop on the bottom of the mounting plate. Secure in place to prevent damage to fixture wires during wiring. Cut fixture wires a MINIMUM of 20 from the top edge of the canopy. If there is NOT a safety cable attached to the canopy[C], cut fixture wires a MINIMUM of 6 from the top edge of the canopy.

FAQ

  • Q: How should I install this fixture?
  • A: Follow the installation instructions provided in the user manual. If you are not familiar with electrical code requirements, it is recommended to hire a certified electrician.
  • Q: Can I use a dimmer with this LED fixture?
  • A: Yes, this LED fixture is compatible with most standard incandescent dimmers, LED dimmers, and electronic low-voltage dimmers. For optimal performance, an electronic low-voltage dimmer should be used. Refer to kichler.com/dimming for a list of compatible dimmers.
  • Q: What should I do if there is a safety cable attached to the canopy?
  • A: Attach the other end of the safety cable to the mounting plate by hooking it into a loop on the bottom of the mounting plate. Secure it in place to prevent damage to fixture wires during wiring. Cut fixture wires a MINIMUM of 20 from the top edge of the canopy.
  • Q: What should I do if there is no safety cable attached to the canopy?
  • A: Cut fixture wires a MINIMUM of 6 from the top edge of the canopy.

Fixture Diagram

KICHLER-43852BK-1-Light-Mini-Pendant-Ceiling-Light-Fixture-
FIG-1

Parts List

  • [A] Outlet Box
  • [B] Mounting Plate
  • [C] Canopy
  • [D] Countersunk Mounting Screw
  • [E] Plate Mounting Screw
  • [F] Cable Strain Relief
  • [G] Support Cable
  • [H] Drywall Anchors
  • [I] Drywall Mounting Screws

Cautions
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.
WARNING
This fixture is intended for installation under the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.
DIMMING

  • This LED fixture is compatible with most standard incandescent dimmers, LED dimmers, and electronic low-voltage dimmers.
  • For optimal performance, an electronic low-voltage dimmer should be used.
  • See kichler.com/dimming for a list of compatible dimmers.

CLEANING

  • Always be certain that the electric current is turned off before cleaning.
  • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

Installation Instructions

  1. Remove mounting plate[B] from canopy[C] by unscrewing four (4) countersunk mounting screws[D] from canopy: two (2) screws on front of the canopy, and two (2) screws on back of the canopy. Retain screws for re-attaching the canopy to the mounting plate.

  2. Attach mounting plate[B] to outlet box[A] using the plate mounting screws[E]. The mounting plate can be adjusted to suit the position of the fixture.

  3. Using the mounting plate as a template, mark the positions for the two (2) drywall anchors[H], one on each end of the mounting plate. Unscrew the plate mounting screws, and remove the plate mounting screws and mounting plate.

  4. Drill 5mm (3/16”) holes in the ceiling where marked, and insert the two (2) drywall anchors[H].

  5. Attach mounting plate[B] to outlet box[A] using the plate mounting screws[E]. Secure the mounting plate to the ceiling by screwing the two (2) drywall mounting screws[I] through the drywall mounting screw holes in the mounting plate, and into the drywall anchors.

  6. Adjust each support cable[G] to the desired length. To shorten the cable, push up the cable at the cable strain relief[F] attached to the canopy and push the cable into the canopy. To lengthen the cable, push up on the cable strain relief and gently pull down on the cable to the desired length.

  7. If there is a safety cable attached to the canopy[C], attach the other end of the safety cable to the mounting plate[B] by hooking it into a loop on the bottom of the mounting plate. Secure in place to prevent damage to fixture wires during wiring. Cut fixture wires a MINIMUM of 20” from the top edge of the canopy.
    If there is NOT a safety cable attached to the canopy[C], cut fixture wires a MINIMUM of 6” from the top edge of the canopy.

  8. Grounding instructions: (See Illus. a or b).

    • On fixtures where the mounting plate is provided with a hole and two raised dimples, wrap ground wire from the outlet box around the green ground screw, and thread it into the hole.
    • On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and green ground screw, and thread into the mounting plate.
      If the fixture is provided with ground wire, connect the fixture ground wire to the outlet box ground wire with the wire connector after following the above steps. Never connect ground wire to black or white power supply wires .KICHLER-43852BK-1-Light-Mini-Pendant-Ceiling-Light-Fixture-
FIG-2
  9. Make wire connections. Reference the chart below for correct connections and wire accordingly.
    Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
    ---|---
    Black| White
    Parallel cord (round & smooth)| Parallel cord (square & ridged)
    Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
    Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
    *Note: When parallel wire (SPT 1 & SPT 2) is used. The neutral wire

is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)

|

  1. Raise fixture to ceiling, carefully passing canopy[C] over mounting plate[B].
    NOTE: Make sure wires do not get pinched between the canopy and the ceiling.

  2. Align holes on the front and back of the canopy with holes on the flanges of the mounting plate.

  3. Secure the canopy to the mounting plate using countersunk mounting screws[D] previously removed from the canopy.

FCC STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

For warranty information please visit: kichler.com/warranty.

CONTACT

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

KICHLER User Manuals

Related Manuals