RAB CRLEDFA-xR-xxS-9CCT-UNV-WS LED 8 Commercial Downlight Instructions
- June 15, 2024
- RAB
Table of Contents
RAB CRLEDFA-xR-xxS-9CCT-UNV-WS LED 8 Commercial Downlight
Product Information
- Product Name: Field Adjustable Commercial Downlight
- Model Number: CRLEDFA-xR-xxS-9CCT-UNV-WS
- Manufacturer: RAB Lighting Inc.
Specifications
- Field adjustable downlight
- Designed for commercial use
- Compatible with LED lamps only
- Available in multiple CCT (Correlated Color Temperature) options
- Universal voltage
- Energy-saving design
What’s in the Box
- Downlight (1)
- MC connector (1)
- Lumi Sticker (1)
- Template (1)
Optional Accessories
Visit rablighting.com for the downlight accessory compatibility lists.
- Goof Ring:
- DL4-6GOOF/R/P/CRLEDFA – For use with 6″ ceiling hole applications
- DL6-8GOOF/R/P/CRLEDFA – For use with 8″ ceiling hole applications
- DL8-10GOOF/R/P/CRLEDFA – For use with 10″ ceiling hole applications
- DL8-12GOOF/R/P/CRLEDFA – For use with 12″ ceiling hole applications
- DL10-12GOOF/R/P/CRLEDFA – For use with 12″ ceiling hole applications
- Plate:
- DLFRAME/C6R
- DLFRAME/C8R
- DLPLATE/C3468R/NB – Mounting plate with nailer bar
Installation Instructions
Installation with Existing Frame
Note: These instructions do not cover all details or variations in
equipment nor do they provide for every possible situation during
installation, operation, or maintenance.
- Remove CFL, Incandescent, or HID lamp. (Fig.1)
- Remove reflector from rough-in (mounting frame). (Fig.2)
- Remove J-Box metal plate with existing lamp ballast. Do not dispose. Disconnect all wires from the ballast. (Fig.4)
- Remove the existing lamp metal conduit (MC) cable from the J-Box. (Fig.5)
- Select desired lumen and CCT level using switch on driver box. (Fig.6)
- Wire nut the ground (green) wire in the junction box. Wire nut the black input wire with the black wire from the MC cable and wire nut the white input wire with the white wire from the MC cable. Wire nut the purple input wire with the purple wire from the MC cable and wire nut the pink input wire with the pink wire from the MC cable. If the purple and pink wires are not in use, cap these with wire nuts. (Fig.8)
- Install the junction box cover plate. (Fig.9)
- Turn power ON.
For more detailed instructions and diagrams, please refer to the user manual.
Frequently Asked Questions (FAQ)
-
Q: Can I use incandescent lamps with this downlight?
A: No, this downlight is designed to operate only with LED lamps. Do not attempt to install or operate incandescent lamps in this luminaire. -
Q: How can I adjust the lumen and CCT level?
A: The desired lumen and CCT level can be selected using the switch on the driver box. Refer to Figure 6 in the installation instructions for more details. -
Q: Where can I find a list of compatible accessories for this downlight?
A: You can visit rablighting.com for the downlight accessory compatibility lists.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNINGS:
-
Risk of electrical shock. Disconnect power at fuse or circuit breaker before installing or servicing.
-
To prevent early lamp failure, lamp should only be installed in operating environments ranging between -30°C and 40°C (-22°F and 104°F).
-
No user-serviceable parts inside. To avoid electrical shock do not disassemble product.
-
Risk of fire or electric shock, LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
-
Risk of fire or electric shock, Install this kit only in luminaires that have the construction features and minimum dimensions shown in these instructions and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
-
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation
-
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
-
Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.
-
The retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined
by authorities having jurisdiction. Product must be installed by a qualified electrician in accordance with the applicable and appropriate electrical codes. The installation guide does not supersede local national regulations for electrical installations. This device is not intended for use with emergency exits. -
Caution – risk of fire. Consult a qualified electrician to ensure correct branch circuit conductor.
-
Minimum 90ºC supply conductors.
-
Installers should examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts prior to installation of the retrofit kit.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WHAT’S IN THE BOX
TOOLS NEEDED
This LED Recessed Kit requires very few tools for installation. A
screwdriver and a pair of wirecutters WI help to install the downlight to a
JBox or housing.
OPTIONAL ACCESSORIES
Goof Ring
Visit rablighting.com for the downlight accessory
compatibility lists.
-
DL4-6GOOF/R/P/CRLEDFA
For use with 6″ ceiling hole applications -
DL6-8GOOF/R/P/CRLEDFA
For use with 8″ ceiling hole applications -
DL8-10GOOF/R/P/CRLEDFA
For use with 10″ ceiling hole applications -
DL8-12GOOF/R/P/CRLEDFA
For use with 12″ ceiling hole applications -
DL10-12GOOF/R/P/CRLEDFA
For use with 12″ ceiling hole applications
Plate
Frame
INSTALLATION
WITH EXISTING FRAME
- Shut power OFF to the fixture.
- Remove CFL, Incandescent or HID lamp. (Fig.1)
- Remove reflector from rough-in (mounting frame). (Fig.2)
- Remove socket assembly from reflector.(Fig.3)
- Remove J-Box metal plate with existing lamp ballast. Do not dispose. Disconnect all wires from the ballast. (Fig.4)
- Remove the existing lamp metal conduit (MC) cable from the J-Box. (Fig.5)
- Select desired lumen and CCT level using switch on driver box. (Fig. 6)
- Fasten the LED retrofit kit MC cable to the J-Box. (Fig.7)
- Wire nut the ground (green) wire in the junction box. Wire nut the black input wire with the black wire from the MC cable and wire nut the white input wire with the white wire from the MC cable. Wire nut the purple input wire with the purple wire from the MC cable and wire nut the pink input wire with the pink wire from the MC cable. If the purple and pink wires are not in use, cap these with wire nuts. (Fig.8)
- Install the junction box cover plate. (Fig.9)
- Install the retrofit kit in the rough-in by lifting both retention tabs. Push the kit until it sits flush against the ceiling. (Fig.10)
- Turn power ON.
WITHOUT EXISTING FRAME
- Use the template included in the box to cut a hole in the ceiling. (Fig.11)
- Select desired lumen and CCT level using switch on driver box. (Fig.12)
- Shut power OFF to the fixture. Fasten the LED kit MC cable to a junction box with MC connector. Wire nut the ground (green) wire in the junction box. Wire nut the black input wire with the black wire from the MC cable and wire nut the white input wire with the white wire from the MC cable. Wire nut the purple input wire with the purple wire from the MC cable and wire nut the pink input wire with the pink wire from the MC cable. If the purple and pink wires are not In use, cap these with wire nuts. (Fig.13)
- Install junction box cover plate. (Fig.14)
- Install the LED kit by lifting both retention tabs upward. (Fig.15)
- Push the kit until it sits flush against the ceiling.
INSTALLATION WITH EMERGENCY BATTERY BACKUP
Take the Emergency Battery Backup System and snap in the MC cable from the
EMBB into the J-Box. Fasten the LED retrofit kit MC cable to the J-Box. In the
J-box, use wire nuts to do the wire connections as illustrated in the diagram
below. Make sure Emergency Driver is grounded. Please visit rablighting.com to
view the emergency battery backup compatibility list.
DIMENSION
MINIMUM LUMINAIRE DIMENSION
DIMENSIONAL DRAWINGS
Easy Answers
Visit our website for product info: rablighting.com
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request
RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>