Features:

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105°C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

IS13252   UL62368-1    BS EN/EN62368-1     1EC62368-1    TPTC004

SPECIFICATION

MEAN WELL RT-65B 65W Triple Output Switching Power Supply
2

MODEL RT-65A RT-65B RT-65C RT-65D
INPUT VOLTAGE RANGE 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC

surge for 5sec. Without damage)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 76%| 76%| 77%| 78%
AC CURRENT (Typ.)| 2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| OVERLOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT| WORKING TEMP.| -25 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85°C , 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0~50℃) on +5V output
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 7)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, BIS IS 13252(Part 1):2010/IEC 60950-1:2005, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
| EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
| EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035,BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS| MTBF| 2720.8K hrs min. Telcordia SR-332 (Bellcore) ;507.6K hrs min. MIL-HDBK-217F (25°C)
DIMENSION| 1299838mm (LWH)
PACKING| 0.44Kg; 30pcs/13.2Kg/0.72CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 
  3. Tolerance : includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%. 
  4. Line regulation is measured from low line to high line at rated load. 
  5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 
  6. Each output can work within current range. But total output power can’t exceed rated output power. 
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1 mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com
  8. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft). 

※Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Terminal Pin No. Assignment

Pin No. Assignment
1 AC/L
2 AC/N
3 FG
4 NC
5 DC OUTPUT V3
6 DC OUTPUT +V2
7 DC OUTPUT COM
8 DC OUTPUT +V1
Block Diagram

fosc : 60KHz

 MEAN WELL RT-65B 65W Triple Output Switching Power Supply
c

  1. EMI FILTER
  2. RECTIFIERS & FILTER
  3. POWER SWITCHING
  4. O.L.P.
  5. CONTROL
  6. O.V.P.
  7. DETECTION CIRCUIT
Derating Curve

AMBIENT TEMPERATURE (°C)

Output Derating VS Input Voltage

INPUT VOLTAGE (VAC) 60Hz

File Name:RT-65-SPEC 2023-02-27

Downloaded from Arrow.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals