PA Ball Speaker
These instructions are intended for installers with sufficient knowledge of
100V technology for PA applications. Please read the instructions carefully
prior to installation and keep them for later reference.
Applications
This speaker is specially designed for applications in PA systems. It is
equipped with a transformer for operation at 100V systems, but it may also be
directly connected to amplifier outputs of low impedance. The connected load
is matched via selection of the connection cables.
Due to its weatherproof cabinet (IP44), it is also suitable for outdoor
installation.
Safety Notes
The speaker corresponds to all relevant directives of the EU and is therefore marked with .
- Protect the speaker against extreme high or low temperatures (admissible ambient temperature range 0–40°C).
- For cleaning only use a soft cloth, dry or slightly damp; never use chemicals or aggressive detergents.
- No guarantee claims for the speaker and no liability for any resulting personal damage or material damage will be accepted if the speaker is used for other purposes than originally intended, if it is not correctly installed or if it is overloaded.
If the speaker is to be put out of operation definitely, dispose of the speaker in accordance with local regulations.
Mounting
Suspend the speaker from its cable using standard mounting accessories for lamps.
Electrical Connection
WARNING During operation, there is a hazard of contact with a dangerous voltage of up to 100V at the connections. Always insulate the connection cables which are not used.
Installation must be carried out by skilled personnel only. Observe the correct power matching. An incorrect matching may damage the PA amplifier!
- If the PA system is switched on, switch it off completely before connecting it!
- Connect the speaker: Connect the black core (negative pole) and the orange, grey, or white core corresponding to the desired power rating by the speaker to the 100V output of the amplifier (see table). Alternatively, connect the black core and the brown core to an amplifier output of low impedance.
When connecting several speakers, make sure that all speakers have the same polarity (black core = negative pole) and that the amplifier is not overloaded.
Subject to technical modification.
Specifications
Frequency range
Power rating / Impedance
when connecting the cores
black – orange (at 100V)
black – grey (at 100V)
black – white (at 100V)
black – brown (not for 100V outputs!)
SPL
IP code of housing
Dimensions, weight
Support
MONACOR INTERNATIONAL GmbH & Co. KG
Zum Falsch 36
28307 Bremen
Germany
Copyright© by MONACOR INTERNATIONAL.