KRAMER VP-427X1 4K HDBT-HDMI Receiver User Guide

June 9, 2024
Kramer

VP-427X1 Quick Start Guide This guide helps you install and use your VP- 427X1 for the first time.
Go to www.kramerav.com/downloads/VP-427X1
to download the latest user manual and check if firmware upgrades are available.

VP-427X1 4K HDBT-HDMI Receiver

Step 1: Check what’s in the box

VP-427X1 4K HDBT/HDMI Receiver/Scaler
1 Power adapter and cord
1 Bracket set
4 Rubber feet
1 Quick start guide

Step 2: Get to know your VP-427X1

# Feature Function
1 ON LED Lights green when device is powered.
2 INPUT Select Button Press to select the input (HDBT or HDMI).
3 INPUT LEDs HDBT
HDMI Lights blue when the HDMI input is selected.
4 IR IN 3.5mm Mini Jack Connect to an IR sensor to control a remote device

connected to the transmitter side via HDBT tunneling.
5| IR OUT 3.5mm Mini Jack| Connect to an extemal IR emitter to control a local device from the transmitter side.
6| MENU Button| Press to enter/exit the on-screen display (OSD) menu. Press together with the — button to reset the output to 1080p resolution.
7| ENTER Button| In OSD, press to choose the highlighted menu item. Press together with the FREEZE/+ button to reset the output to XGA resolution (1024×768).
8| — Button| In OSD, press to move back through menus or decrement parameter values. Press together with the MENU button to reset the output to 1080p resolution.
9| FREEZE/+ Button| In OSD, press to move forward through menus or increment parameter values. When not in OSD, press to freeze the display.
10| Ethernet RJ-45 Connector| Connect to a PC via a LAN to setup and monitor the VP-427X1 via the Windows software, as well as upgrade the firmware.
11| PROG USB Connector| Connect to a USB stick to perform firmware upgrades.
12| INPUT Connectors| HDBT RJ-45 with PoE (PD)| Connect to a transmitter (for example, the Kramer TP-789Txr).
13| HDMI| Connect to an HDMI source.
14| RS-232 CONTROL 3-pin Terminal Block Connector| Connect to a serial controller or PC.
15| REMOTE Contact-Closure 4-pin Terminal Block Connector| Connect to contact closure switches, an occupancy sensor and/or toggle switches (contact between the desired pin and GND pin), to turn display on or off. See Step 6: Operate VP-427X1.
16| AUDIO 5-pin Terminal Block Connector| Connect to a balanced stereo audio acceptor.
17| HDMI OUT Connector| Connect to an HDMI acceptor.
18| 12V DC Connector| Connect to the supplied power adapter.

Step 3: Mount VP-427X1
Install VP-427X1 using one of the following methods:

  • Attach the rubber feet and place the unit on a flat surface.
  • Fasten a bracket (included) on each side of the unit and attach it to a flat surface (see www.kramerav.com/downloads/VP-427X1).
  • Mount the unit in a rack using the recommended rack adapter (see www.kramerav.com/product/VP-427X1).
  • Ensure that the environment (e.g., maximum ambient temperature & air flow) is compatible for the device.
  • Avoid uneven mechanical loading.
  • Appropriate consideration of equipment nameplate ratings should be used for avoiding overloading of the circuits.
  • Reliable earthing of rack-mounted equipment should be maintained.
  • Maximum mounting height for the device is 2 meters.

Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your VP- 427X1.

| Connecting the audio output
To a balanced stereo audio acceptor:
---|---
| To an unbalanced stereo audio acceptor:

Wiring the RJ-45 Connectors
This section defines the TP pinout, using a straight pin-to-pin cable with RJ-45 connectors.

For HDBT cables, it is recommended that the cable ground shielding be connected/soldered to the connector shield.

EIA /TIA 568B

PIN| Wire Color
1| Orange / White
2| Orange
3| Green / White
4| Blue
5| Blue / White
6| Green
7| Brown / White
8| Brown

To achieve specified extension distances, use the recommended Kramer cables available at www.kramerav.com/product/VP- 427X1.Using third-party cables may cause damage!

Step 5: Connect power
If there is no PoE via the HDBT input, connect the power adapter to the VP- 427X1 and plug it to the mains electricity.

Safety Instructions (See www.kramerav.com for updated safety information)

Caution:

  • For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
  • There are no operator serviceable parts inside the unit.

Warning:

  • Use only the power cord that is supplied with the unit.
  • Disconnect the power and unplug the unit from the wall before installing.

Step 6: Operate VP-427X1

Operate VP-427X1 via:

  • Front panel buttons.
  • Remotely, by RS-232 serial commands transmitted by a touch screen system, PC, or other serial controller
  • Embedded web pages via the Eth.

RS-232 Control / Protocol 3000

Baud Rate:| 115,200| Parity:| None| Stop Bits:| 1
Data Bits:| 8| Command Format:| ASCII| |
Example: (Route video HDBT INPUT to HDMI OUTPUT): #ROUTEV1,1,1

Default Ethernet Parameters

IP Address: 192.168.1.39 UDP Port #: 50000
Subnet Mask: 255.255.0.0 TCP Port #: 5000
Gateway: 0.0.0.0. Default Username/password: Admin/Admin

Operating via the remote control switches
Momentarily connect the desired pin to the GND pin to select an input:

Pin Name Function
TOGGLE One button toggles between display on and display off (instead of

using two separate buttons for on and off). Alternatively, using the VP-427X1 OSD, configure turning the display on or off according to whether a switch is open or closed, for example, when using an occupancy sensor.
OFF| Turn off the display.
ON| Turn on the display.

WWW.KRAMERAV.COM