VP-427X1 4K HDBT-HDMI Receiver
Step 1: Check what’s in the box
VP-427X1 4K HDBT/HDMI Receiver/Scaler
1 Power adapter and cord
1 Bracket set
4 Rubber feet
1 Quick start guide
Step 2: Get to know your VP-427X1
# | Feature | Function |
---|---|---|
1 | ON LED | Lights green when device is powered. |
2 | INPUT Select Button | Press to select the input (HDBT or HDMI). |
3 | INPUT LEDs | HDBT |
HDMI | Lights blue when the HDMI input is selected. | |
4 | IR IN 3.5mm Mini Jack | Connect to an IR sensor to control a remote device |
connected to the transmitter side via HDBT tunneling.
5| IR OUT 3.5mm Mini Jack| Connect to an extemal IR emitter to control a local
device from the transmitter side.
6| MENU Button| Press to enter/exit the on-screen display (OSD) menu. Press
together with the — button to reset the output to 1080p resolution.
7| ENTER Button| In OSD, press to choose the highlighted menu item. Press
together with the FREEZE/+ button to reset the output to XGA resolution
(1024×768).
8| — Button| In OSD, press to move back through menus or decrement parameter
values. Press together with the MENU button to reset the output to 1080p
resolution.
9| FREEZE/+ Button| In OSD, press to move forward through menus or increment
parameter values. When not in OSD, press to freeze the display.
10| Ethernet RJ-45 Connector| Connect to a PC via a LAN to setup and monitor
the VP-427X1 via the Windows software, as well as upgrade the firmware.
11| PROG USB Connector| Connect to a USB stick to perform firmware upgrades.
12| INPUT Connectors| HDBT RJ-45 with PoE (PD)| Connect to a transmitter (for
example, the Kramer TP-789Txr).
13| HDMI| Connect to an HDMI source.
14| RS-232 CONTROL 3-pin Terminal Block Connector| Connect to a serial
controller or PC.
15| REMOTE Contact-Closure 4-pin Terminal Block Connector| Connect to contact
closure switches, an occupancy sensor and/or toggle switches (contact between
the desired pin and GND pin), to turn display on or off. See Step 6: Operate
VP-427X1.
16| AUDIO 5-pin Terminal Block Connector| Connect to a balanced stereo audio
acceptor.
17| HDMI OUT Connector| Connect to an HDMI acceptor.
18| 12V DC Connector| Connect to the supplied power adapter.
Step 3: Mount VP-427X1
Install VP-427X1 using one of the following methods:
- Attach the rubber feet and place the unit on a flat surface.
- Fasten a bracket (included) on each side of the unit and attach it to a flat surface (see www.kramerav.com/downloads/VP-427X1).
- Mount the unit in a rack using the recommended rack adapter (see www.kramerav.com/product/VP-427X1).
- Ensure that the environment (e.g., maximum ambient temperature & air flow) is compatible for the device.
- Avoid uneven mechanical loading.
- Appropriate consideration of equipment nameplate ratings should be used for avoiding overloading of the circuits.
- Reliable earthing of rack-mounted equipment should be maintained.
- Maximum mounting height for the device is 2 meters.
Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your VP-
427X1.
| Connecting the audio output
To a balanced stereo audio acceptor:
---|---
| To an unbalanced stereo audio acceptor:
Wiring the RJ-45 Connectors
This section defines the TP pinout, using a straight pin-to-pin cable with
RJ-45 connectors.
For HDBT cables, it is recommended that the cable ground shielding be connected/soldered to the connector shield.
EIA /TIA 568B
PIN| Wire Color
1| Orange / White
2| Orange
3| Green / White
4| Blue
5| Blue / White
6| Green
7| Brown / White
8| Brown
To achieve specified extension distances, use the recommended Kramer cables available at www.kramerav.com/product/VP- 427X1.Using third-party cables may cause damage!
Step 5: Connect power
If there is no PoE via the HDBT input, connect the power adapter to the VP-
427X1 and plug it to the mains electricity.
Safety Instructions (See www.kramerav.com for updated safety information)
Caution:
- For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
- There are no operator serviceable parts inside the unit.
Warning:
- Use only the power cord that is supplied with the unit.
- Disconnect the power and unplug the unit from the wall before installing.
Step 6: Operate VP-427X1
Operate VP-427X1 via:
- Front panel buttons.
- Remotely, by RS-232 serial commands transmitted by a touch screen system, PC, or other serial controller
- Embedded web pages via the Eth.
RS-232 Control / Protocol 3000
Baud Rate:| 115,200| Parity:| None| Stop Bits:| 1
Data Bits:| 8| Command Format:| ASCII| |
Example: (Route video HDBT INPUT to HDMI OUTPUT): #ROUTEV1,1,1
Default Ethernet Parameters
IP Address: | 192.168.1.39 | UDP Port #: | 50000 |
---|---|---|---|
Subnet Mask: | 255.255.0.0 | TCP Port #: | 5000 |
Gateway: | 0.0.0.0. | Default Username/password: | Admin/Admin |
Operating via the remote control switches
Momentarily connect the desired pin to the GND pin to select an input:
Pin Name | Function |
---|---|
TOGGLE | One button toggles between display on and display off (instead of |
using two separate buttons for on and off). Alternatively, using the VP-427X1
OSD, configure turning the display on or off according to whether a switch is
open or closed, for example, when using an occupancy sensor.
OFF| Turn off the display.
ON| Turn on the display.
References
- Kramer | Audio-Visual Solutions and Experiences
- Kramer | Audio-Visual Solutions and Experiences
- Application Diagrams - Kramer Electronics
- kramerav.com/product/VP-427X1
- Kramer Pro AV manufacturer - Product Categories
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>