ALPICAIR 250T Wall Mounted Vertical Heat Recovery Ventilator Instruction Manual
- June 14, 2024
- ALPICAIR
Table of Contents
ALPICAIR 250T Wall Mounted Vertical Heat Recovery Ventilator
General Information
General Information
- Safety Attention
- Please read the following safety instructions carefully before installation. Please observe all instruction in order to avoid any injury or damage to equipment or property.
Warning/Attention a risk of injury or equipment damage.
- Please read the following safety instructions carefully before installation. Please observe all instruction in order to avoid any injury or damage to equipment or property.
Installation
- Installation and maintenance to be carried out by qualified person to avoid danger, end users should not install this equipment by themselves.
- his equipment should be connected to power supply by the qualified electrician, and it should be grounded.
- It shall be moved and installed according to the weight and size of the product.
- The equipment should be installed in accordance with the installation instructions (chapter 3).
- The equipment should be installed in a dry place indoors, not in a place where there may be flammable gas leakage.
- A bird net or similar device should be installed at the vents of outdoor. When there are nests and obstructions there, please clean them, otherwise it will cause indoor hypoxia.
Operation
- Children, persons with reduced physical sensory/mental abilities or lack of experience and knowledge are prohibited from using this product unless they are supervised or guided by the person responsible for their safety.
- Must use rated voltage, otherwise it may cause fire or electric shock.
- Shall replace the filter at the recommended/required interval.
- Do not use corrosive or solvents to clean the equipment.
- Do not touch the equipment with wet hand.
Maintenance
- If there is abnormal noise, smell or smoke, please cut off the power sup-ply and contact the installation technician.
- Power Supply should be cut off before maintenance (charter 5).
- It is forbidden to modify the unit. A qualified professional must use the original spare parts provided by the manufacturer to replace the parts.
Product Introduction
Package
- The package includes the following items. Please check when open the box. In case of damage or incomplete delivery, please contact your supplier immediately.
|
- HRV 1pic
Please check the sticker and model to make sure they are correct.
---|---
| Mounting bracket 1 piece
| Condensate drain connector (with seal ring) 1 piece
| Condensate drain seal (with seal ring) 1 piece
| Manual 1 set
Introduction
- Principle and functions.
- This unit is designed to provide mechanical supply and extract ventilation with heat recovery. It is equipped with heat exchanger, filters and EC motor, etc. It has functions as below:
- Fresh air purification: after the outdoor air driven by supply fan and go through the filter, the indoor air quality will highly improved. primary filter
- Energy recover: the unit is equipped with heat exchanger, which can recover the energy of EA and then recycle to OA, this function will greatly decrease the loss of energy.
Specifications
| ACFA-250T| ACFA-350T| ACFA-500T
---|---|---|---
Machine| Housing material| Sprayed sheet metal
Internal materials| EPP
Heat exchanger materials| Polystyrene
Fan motor type| EC
Filter class| G4 or optional F7
Control Panel| Two screen controls, buttons + indicator light/digital tube
Bypass| 100% auto bypass
Working conditions| Standard| -10 to 40℃
Equipped with duct type heater| -20 to 40℃
Pipe connection| Pipe diameter| Φ160mm| Φ200mm
Electrical parameters| Power supply| 230V 50Hz 1Ph
Max. power| 137W| 272W| 412W
Max. current| 1.0A| 1.9A| 2.9A
Product Introduction
Dimensions
Installation Introduction
- The operation process from right installation (factory default) to the left installation is as follows:
- Step 1 :Press the position indicated in the figure above to open the access panel buckle.
- Step 2: Remove the access panel.
- Step 3 :If the equipment is equipped with an F7 filter as option, switch the positions of the two filters as shown in the figure. Note if both filters are G4 grade, this step can be ignored.
- Step 4: Use the hidden control panel at the top right corner, follow the instructions (4.3) to select the corresponding control program.
- Step 5: Install the filter and access panel back to the unit.
Electric
-
Power supply of this equipment should be connected by a qualified electrician, and the equipment must be grounded.
-
Use national standard cables, cable 3×1.5mm².
-
Power supply :230V/50Hz/1Ph
-
L line=Brown, N line=Blue, GND line=Yellow & Green
-
The electric circuit must be protected by a bipolar circuit breaker.
-
Remote touch screen control panel (optional) connection
This product can be equipped with touch screen remote controller, connected through the control cable. The connection process is as follows and should be operated by a qualified electrician: -
Step1: Cut off the power.
-
Step2: Use a screw driver to remove the screws which fixing the cover of the electric control box at the top
-
Step3: Pull out the sockets from PCB for use.
-
Step4: Open the controller casing.
-
Step5: Connect the wires between controller and sockets (PCB) according to “B, A, GND and +12V”.
Note: All the wires need to pass through the threading connector on the cover of the electric control box, and tighten the threading connector. Back of the controller PCB -
Step6: Finally, plug the sockets that has been wired back into the PCB, and cover the electric control box.
-
Condensate drainage
- Before using, make sure to connect a condensate drain with this device. The connection process for condensate drain is as below:
-
According to the installation way, install the drain connector and drain seal to the corresponding position.
- Use a U-shaped trap to connect the drain connector and the drain pipe.
- Before using the device, make sure to immerse the drain pipe in water.
- Make sure that all connectors are tightly sealed to prevent water leakage.
Operation
Operation Instruction
Before Startup
- Please carefully check the followings:
- Check the voltage and frequency of the power source and its connection if is correct.
- Should be properly connected to the ground line.
- Connected to ducting and condensation pipe properly
Default factory setting
- The device comes with below default setting:
| ACFA-250T| ACFA-350T| ACFA-500T
---|---|---|---
Airflow m³/h
| SPEED 1| 80| 100| 105
SPEED 2| 100| 130| 185
SPEED 3| 145| 180| 270
SPEED 4| 175| 245| 350
Operation Instruction
- The device has two controller panels, Panel 1-Daily simple settings, Panel 2-Advance parameters settings. Positions are as followed:
-
Speed control: Press to switch from Speed 1 to 4, speed 1 is “traveling mode”, when switch to this mode, the ventilator turns to super low speed.
-
Fan Boost: Press to switch to the boost speed for 30 minutes, and then return to original status.
-
Filter timer reset: After 60 days running, when the filters is needed cleaning or replacement, the light will be illumined. After replacement or cleaning, hold this button for long time to reset the filter timer.
-
Error Indicator: When it’s illumined, the fan or the sensors are in error, the indicator lights off after error cleared.
-
Bypass: When bypass is on, it will be illumined. When bypass is off, then the light is off, bypass opening temperature: Outdoor 17 to 21 degree Celsius.
-
Humidity control : when the ventilator is running, if indoor humidity over 75%RH, ventilator will enter the boost speed, until the humidity lower than 75%RH.
-
CO2 control (optional): By connecting a CO2 sensor to it, when the ventilator is running, if the indoor CO2 value over 1000PPM, ventilator will enter the boost speed, until the CO2 value lower than 1000PPM.
-
Defrost: When defrost mode is activated, it will be illumined. Defrost mode activated temperature: Outdoor less than or equal to –5degree Celsius.
Note: In order to prevent frost inside the device, the ventilator is in automatic adjustment and cannot be operated when in defrost mode. -
The above values are default values, user can change the default values by optional touch screen controller or Modbus system.
-
Air volume setting: Press “Speed” to select speed 1 to 4, then press “+” or “-” to set air volume for the selected speed, after 4 speeds setting done then press “Speed” again to save setting or it will be automatically saved after 15 seconds without operation.
-
Balance rate setting: Long press the “Speed” button for 6 seconds when the digital display shows “LPL”, press “+” or “-” to set the air volume bal-ance rate of supply and exhaust.
-
The value is 0, then supply airflow is equal to exhaust airflow.
-
The value is 1 to 50, then supply airflow is larger than exhaust airflow.
Note: the larger the value, the smaller the exhaust airflow. -
The value is –50 to –1, then supply airflow is less than exhaust airflow.
Note: the larger the absolute value, the smaller the supply air flow.
-
Right and left installation switching: Long press the “+” key for 6 seconds when the digital display shows “PLP”, press “Speed” button to switch between the right and left installation modes. The number 1 represents the right type, and the number 2 represents the left type.
Note: The setting must be consistent with the installation form, otherwise, it will affect the use of the ventilator. -
Restore factory settings : press the “+” and “-” buttons at the same time, the air volume and air volume balance rate will return to the factory default settings.
-
RS485 address setting: Long press the “-” key for 6 seconds, press “+” or “-” to set the RS485 address of the ventilator for centralized control.
APP Instruction
- Search “SMART LIFE” at the APP Store or scan the QR code on the right to download the APP.
- Sign up and log in your account.
- Install the WIFI module onto the PCB board, as indicated in the wiring diagram.
- Check if the indicating light is blinking; if not, long press the black reset button in the WIFI module until the light is blinking constantly.
- Open “SMART LIFE” APP, press and then g o t o “Small Home Appliances” and select “Ventilation system(BLE+WI-FI)”.
- Choose the correct device hotspot, which is normally named “SmartLife-xxx”, Until the hotspot is successfully connected. Press “Return” at the top left corner to return and wait for the ventilator to be connected to the mobile phone.
- After the connection is successful, press to edit the ventilator name, and press “Done” to enter the ventilator control page.
- Then user can go to the device’s page for all the functions.
- 4.5 RS485 Protocol
- MODBUS-RTU Protocol details are as followed.
No | Item | Specifications |
---|---|---|
1 | Interface | Half-Duplex RS-485 |
2 | Baud Rate | 9600 |
3 | Transmission | RTU(Remote Terminal Unit) |
4 | Data Stream | Address + Function code + Data quantity + Data 1…Data n + CRC |
MS byte +CRC LS byte
5| Address| 0-99
6| Function code| 3, 6
9| CRC Check sum| CRC-16
10| Byte format| 10bit format: 1 start bit+8 data bit+1 stop bit
11| Check sum| CRC-16
12| 0XFF address| Broadcast Address
13| Interface definition| A(+), B(-), two-wire system
Address| Range| Default| Function| Remarks
---|---|---|---|---
0(0x0000)| 0, 1| /| 0=OFF 1=ON|
1(0x0001)| 0-250| /| Filter used time (day)| Every setting will reset the
current alarm
2(0x0002)| 0-120| 60| Filter replacement alarm (day)| 0=Alarm off
3(0x0003)| 0, 1| 0| 0=Filter normal 1=Filter needs cleaning|
4(0x0004)| 0-120| /| EA Temperature(℃)| Data≥20, actual temperature=data
bit-20;
Data<20, actual temperature=20-data bit
5(0x0005)| 0-120| /| SA Temperature(℃)
6(0x0006)| 0-100%| /| OA Humidity|
7(0x0007)| -20-60℃| /| OA Temperature(℃)| Data≥20, actual temperature=data
bit-20;
Data<20, actual temperature=20-data bit
8(0x0008)| 0-100%| /| RA Humidity|
9(0x0009)| -20-60℃| /| RA Temperature(℃)| Data≥20, actual temperature=data
bit-20;
Data<20, actual
temperature=20-data bit
10(0x000a)| 0-2000| /| CO2 Concentration (PPM)|
11(0x000b)| 1-4| /| Volume setting for Speed 1-4|
12(0x000c)| 0-5| /| Running speed| 5=Fan boost
13(0x000d)| 15-30| 16| Temperature setting for heater(℃)|
14 (0x000E)| 0-120| 30| Fan boost Duration (mins)|
15 (0x000F)| | /| Bit0=OA temp and hum error Bit1=RA temp and hum error
Bit2=OA temp error
Bit3=RA temp error
Bit4=CO2 sensor error Bit5=reserved Bit6=Bypass on Bit7=Electric heater on
Bit8=Supply fan error
Bit9=Exhaust fan error Bit10=Fire alarm signal Bit11=Forced ON signal
Bit12=Running signal output Bit13=Error output
Bits are valid.| Fixed position are not affected by left or right type.
---|---|---|---|---
16 (0x0010)| 0, 1| 1| 0=Conventional Defrost OFF 1=Conventional Defrost ON|
17 (0x0011)| 15-99| 30| Defrosting interval (mins)|
18 (0x0012)| 11-30| 25| Defrosting entering temperature(℃)| 11=-9℃ 12=-8℃
20=0℃ 25=5℃
19 (0x0013)| 2-20| 10| Defrosting Duration (mins)|
20 (0x0014)| 0, 1| 1| 0=Humidity Check OFF 1=Humidity Check ON|
21 (0x0015)| 50-99%| 75| Humidity Setting Value|
22 (0x0016)| 0, 1| 0| 0=CO2 Concentration check OFF
1=CO2 Concentration check ON|
23 (0x0017)| 800-1900| 1500| Co2 Setting Value (PPM)|
24 (0x0018)| 0, 1| 1| 0=Manual Bypass 1=AUTO Bypass| When manual bypass is
off, AUTO bypass will be valid.
25 (0x0019)| 5-30| 19| Bypass opening temperature (℃)|
26 (0x001A)| 2-15| 3| Bypass temperature difference(℃)|
---|---|---|---|---
27 (0x001B)| 0, 1| 0| 0=Electric Heater OFF 1=Electric Heater ON|
28 (0x001C)| 0, 1| 0| 0=Manual Bypass OFF 1=Manual Bypass ON|
29 (0x001 D)| 0-10000| /| Fan 1 output voltage| 10000=10.00v
30 (0x001 E)| 0-10000| /| Fan 2 output voltage| 10000=10.00v
31 (0x001 F)| 0-2| Already select- ed based on model during production| Model
selection 0=250CHM
1=350CHM
2=500CHM|
32 (0x002 0)| 0-9999| /| Electricity Consumption (Heater not included) (Kw/h)|
33 (0x002 1)| 0-9999| /| Heater Electricity Con- assumption (Kw/h)| Heater
capacity needed
34 (0x002 2)| 500-3000| 250CHM-0.8kw
350CHM-1kw
500CHM-2kw| Heater Capacity of heater (Kw)| Can be set accorrodingly to actual
case
35 (0x002 3)| 10-30| 15| Forced Defrosting temperature (℃) (OA Temperature)|
11=-9℃ 12=-8℃
20=0℃ 25=5℃
36 (0x002 4)| 0-12| 2| Forced Defrosting interval (hour)|
Maintenance
Maintenance
-
Filter replacement
- It’s recommended that all filters be inspected every 3 months and replaced once or twice a year, or be replaced when the “filter alarm” indicator on the control panel illumined. Otherwise the performance or energy efficiency of the ventilator might be affected.
-
Step 1: Press the two buckles at the top to remove the maintenance panel.
-
Step 2: Take out the SA/RA/bypass filter
-
Step 3: Put the filters back in place after cleaning or replacing, re-install the maintenance panel, then reset the time of the filter alarm (Refer to instruction 4.3).
-
Drain pipe inspection
It’s recommended that the condensate drain pipe should be inspected once or twice a year, preventing the leakage due to poor drainage. -
Air duct, air inlet/outlet inspection
It’s recommended that the air duct, air inlet/outlet should be inspected regularly, preventing the abnormal ventilation of the equipment due to block- age. -
Heat exchanger cleanness
The heat exchanger needs cleanness and maintenance regularly, it’s recommended that the heat exchanger should be cleaned or maintained every 3 years. Please contact our service center if needed.
Failure Diagnosis
Fault diagnosis
Please inspect the machine refer to the table below if this product works
abnormally, and contact our service center to solve the problem in time.
Phenomenon | Possible reasons | Solutions |
---|---|---|
Filter reset indicator light on | – Filter should be cleaned or replaced |
Clean or replace the filter, refer to 5.1
Error light on|
- Fan error
- Sensor error
| Restart the equipment, if still unsolvable, con- tact our service center
directly
Insufficient fresh air|
- Air inlet/out was blocked Filter clogged
- Filters clogged by dusts
|
- Inspect and remove the unidentified matters
- Replace the filters
No response to fan speed selection|
- The device is in special working mode, like defrosting mode
|
- Wait until the special mode finished
Drop noise|
- Condensate drain pipe clogged
|
- Dredge the pipeline
Working noise| The pipe connected to the device is not firmly fixed
- Unidentified matters enter into the internal of the device
- SA fan or EA fan malfunction
|
- Unpack the device, clean the inside or re- place the parts
The device fail to start
|
- Power wiring error
- Equipment protection circuit trip
|
- Inspect the wiring
- Close the protective circuit breaker
Optional Accessories
- Users can configure the following accessories optionally according to their need.
- BVT Partners group
- HQ Address: Vanaginės 37B, Didžioji Riešė, 14261
- Main number : +370 52 753521
- E-mail: info@alpicair.com
- Website: www.alpicair.com
- ISO9000 ISO14001
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>