ALPICAIR AWO AWI-26HRDC1TB Split Air Conditioner User Guide
- June 2, 2024
- ALPICAIR
Table of Contents
- ALPICAIR AWO AWI-26HRDC1TB Split Air Conditioner
- Product Usage Instructions
- Introduction for icons on display screen
- Introduction for icons on display screen
- Introduction for buttons on remote controller
- Function introduction for combination buttons
- Replacement of batteries in remote controller
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ALPICAIR AWO AWI-26HRDC1TB Split Air Conditioner
Specifications:
- Product Name: Remote Controller YBE1F1
- Compatible with Split Air Conditioners Models: AWO/AWI-26HRDC1TB, AWO/AWI-36HRDC1TB, AWO/AWI-54HRDC1TB
- Manufacturer Website: www.alpicair.com
Product Usage Instructions
Thank you for choosing our product. To ensure proper use of the remote controller, please follow the instructions below:
- Insert batteries into the remote controller following the correct polarity.
- Point the remote controller towards the air conditioner unit.
- Press the power button to turn the air conditioner on or off.
- Use the temperature control buttons to adjust the desired temperature.
- Explore additional functions such as fan speed, mode selection, and timer settings.
- Refer to the user manual for advanced features and troubleshooting tips.
Frequently Asked Questions (FAQ):
-
Q: How do I change the batteries in the remote controller?
A: To change the batteries, locate the battery compartment on the back of the remote controller, remove the old batteries, and insert new ones following the correct polarity. -
Q: Can I use the remote controller with other air conditioner models?
A: The remote controller YBE1F1 is specifically designed for use with the mentioned split air conditioner models. Compatibility with other models may vary. -
Q: What should I do if the remote controller is not responding?
A: Make sure the batteries are properly inserted, and there are no obstructions between the remote controller and the air conditioner unit. If issues persist, refer to the troubleshooting section in the user manual or contact customer support.
REMOTE CONTROLLER MANUAL YBE1F1
- For split air conditioners:
- AWO/AWI-26HRDC1TB
- AWO/AWI-36HRDC1TB
- AWO/AWI-54HRDC1TB
Thank you for choosing our product.
For proper use, please read and keep this manual carefully.
Remote Controller Introduction
Introduction for icons on display screen
Introduction for icons on display screen
Introduction for buttons on remote controller
NOTE:
- This is a general use remote controller. It could be used for the air conditioner with multifunction. For the functions which the model doesn’t have, if press the corresponding button on the remote controller, the unit will keep the original running status.
- After putting through the power, the air conditioner will give out a sound. Power indicator is ON. After that, you can operate the air conditioner by using remote controller.
- Under on status, pressing the button on the remote controller, the signal icon ” on the display of remote controller will blink once and the air conditioner will give out a “di” sound, which means the signal has been sent to the air conditioner.
On/Off button
Press this button to turn on the unit. Press this button again to turn off the
unit.
Mode button
-
Press this button to select your required operation mode.
-
When selecting auto mode, air conditioner will operate automatically according to the sensed temperature. Press “Fan” button can adjust fan speed. Press button can adjust fan
blowing angle. -
After selecting cool mode, air conditioner will operate under cool mode. Press ” + ” or ” – ” button to adjust set temperature. Press “Fan” button to adjust fan speed. Press button to adjust fan blowing angle.
-
When selecting dry mode, the air conditioner operates at low speed under dry mode. Under dry mode, fan speed can’t be adjusted. Press button to adjust fan blowing angle.
-
When selecting fan mode, the air conditioner will only blow fan, no cooling and no heating. Press “Fan” button to adjust fan speed. Press button to adjust fan blowing angle .
-
When selecting heat mode, the air conditioner operates under heat mode. Press ” + ” or ” – ” button to adjust set temperature. Press “Fan” button to adjust fan speed. Press button to adjust fan blowing angle.
NOTE:
- For preventing cold air, after starting up heat mode, indoor unit will delay 1 ~5 minutes to blow air (Actual delay time depends on indoor ambient temperature).
- Set temperature range from remote controller: 16~30°C(61-860F).
- This mode indicator is not available for some models.
- Cooling only unit won’t receive heat mode signal. If setting heat mode with remote controller, press ” ON/OFF ” button can’t start up the unit.
Fan button
NOTE:
- It’s low fan speed under dry mode.
- X-FAN function Hold fan speed button for 2s in cool or dry mode, the icon “ ” is displayed and the indoor fan will continue operation for a few minutes in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not available in auto, fan or heat mode.
- This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
- Having set X-FAN function on: After turning off the unit by pressing ” On/Off ” button indoor fan will continue running for a few minutes. at low speed. In this period, hold fan speed button for 2s to stop indoor fan directly.
- Having set X-FAN function off: After turning off the unit by pressing ” On/Off” button, the complete unit will be off directly.
+ / – button
Press “+ “or” – ” button once increase or decrease set temperature 1 °C(°F).
Holding ” + ” or ” – ” button, 2s later, set temperature on remote controller
will change quickly. On releasing button after setting is finished,
temperature indicator on indoor unit will change accordingly.
Wifi button
- Press “Wifi” button to turn on WiFi function, “Wifi” icon will be displayed on the remote controller;
- Hold “Wifi” button for 5s to turn off WiFi function and “Wifi” icon will disappear.(This function is only available for some models.) Under off status, press “Mode” and “Wifi” buttons simultaneously for 1 s, WiFi module will restore factory settings.
NOTE:
This function is only available for some models.
Health button
Press this button to turn on or turn off the health function and UVC lamp in
operation status.
- When selecting ” ” with remote controller, Cold Plasma will be turn on.
- When selecting ” ” with remote controller, UVC lamp will be turn on.
- When selecting ” ” with remote controller, Cold Plasma and UVC lamp will be turn on together.
NOTE:
Health function and UVC lamp are only available for some models.
LID-swing button
Press this button can select up & down swing angle. Fan blow angle can be
selected circularly as below:
- When selecting ” “, air conditioner is blowing fan automatically. Horizontal louver will automatically swing up & down at maximum angle.
- When selecting , air conditioner is blowing fan at fixed position. Horizontal louver will stop at the fixed position.
- Hold ” ” button above 2s to set your required swing angle. When reaching your required angle, release the button.
NOTE:
- Press this button continuously more than 2s, the main unit will swing back and forth from up to down, and then loosen the button, the unit will stop swinging and present position of guide louver will be kept immediately.
- Under swing up and down mode, when the status is switched from off to , if press this button again 2s later, status will switch to off status directly; if press this button again within 2s, the change of swing status will also depend on the circulation sequence stated above.
Humidity button
-
Under cooling mode, press this button can select humidity control with cooling mode, smart dehumidification with cooling mode, and general cooling mode, and they can be set to operate circularly.
-
When humidity control with cooling mode is set, the remote controller will display ” ” , and humidity value “88” and “%” icon will blink for 5s; you can press “+” and “-” buttons to set the humidity value within 5s.
-
Under humidity control with cooling mode, humidity setting range for the remote controller: 40%-80%.
-
Temperature can be adjusted under humidity control with cooling mode.
-
When smart dehumidification with cooling mode is set, the remote controller will display ” ” ; the remote controller and indoor unit will display “Ao” for 5 seconds.
Temperature can be adjusted under smart dehumidification with cooling mode. -
The humidity for smart dehumidification is automatically adjusted according to human body comfort; no need to set the humidity manually.
Under dry mode, press this button can select humidity control with dehumidification mode, continuous dehumidification mode, general dehumidification mode, and they can be set to operate circularly. -
When humidity control with dehumidification mode is set, the remote controller will display ” “, “%” and humidity value “88”; you can press “+” and “-” buttons to set the humidity value. Humidity setting range for the remote controller: 30%-70%. Temperature can’t be adjusted under humidity control with dehumidification mode.
-
When continuous dehumidification is set, the remote controller will display ” ” ; the remote controller and indoor unit will display “Co”.
Temperature can’t be adjusted under continuous dehumidification mode. -
Under continues dehumidification mode, the unit always works under dehumidification status; no need to set temperature and humidity.
NOTE:
- The air conditioner is mainly used for controlling the temperature, while the humidity control is the auxiliary function. The humidity will be affected by the factors such as indoor and outdoor environment, degree of indoor sealing and indoor flow.
- When the set humidity is higher than current atmospheric humidity, the set humidity can’t be reached.
- If the humidity sensor is with malfunction, humidity setting under cooling mode or dehumidification mode will stop and the unit operates under general cooling mode or dehumidification mode.
LR-swing button
Press this button can select left & right swing angle. Fan blow angle can be
selected circularly as below:
NOTE:
- Press this button continuously more than 2s, the main unit will swing back and forth from left to right, and then loosen the button, the unit will stop swinging and present position of guide louver will be kept immediately.
- Under swing left and right mode, when the status is switched from off to , if press this button again 2s later, status will switch to off status directly; if press this button again within 2s, the change of swing status will also depend on the circulation sequence stated above.
- This function only applicable for some models.
Timer button
- At ON status, press this button once can set TIMER OFF. The character of HOUR and OFF will flash. Press “+” or “-” button within 5s can adjust the time of TIMER OFF. After each pressing of “+” or “-” button, time will increase or decrease half an hour. When holding “+” or “-” button, 2s later, the time will change quickly until to reach to your required time.
- After that, press “Timer” button to confirm it. The character of HOUR and OFF won’t flash again. Cancel TIMER OFF: Press “Timer” button again under TIMER OFF status.
- At OFF status, press this button once can set TIMER ON. Please refer to TIMER off for detailed operation.
- Cancel TIMER ON: Press “Timer” button again under TIMER ON status.
NOTE:
- Time setting range: 0.5-24 hours.
- Time interval between two operations can’t exceed 5s. Otherwise, remote controller will exit the setting status automatically.
Sleep button
- Press this button, can select Sleep 1 ( ), Sleep 2 ( ), Sleep 3 ( ) and cancel the Sleep, circulate between these, after electrified, Sleep Cancel is defaulted.
- Sleep 1 is Sleep mode 1, in Cool modes: sleep status after run for one hour, the main unit setting temperature will increase 1 , two hours, setting temperature increased 2 , then the unit will run at this setting temperature; In Heat mode: sleep status after run for one hour, the setting temperature will decrease 1 , two hours, setting temperature will decrease 2 , then the unit will run at this setting temperature.
- Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
- Sleep 3 the sleep curve setting under Sleep mode by DIY;
- Under Sleep 3 mode, press “Health” button for a long time, remote controller enters into user individuation sleep setting status, at this time, the time of remote controller will display “1 HOUR”, the setting temperature “88” will display the corresponding temperature of last setting sleep curve and blink (The first entering will display according to the initial curve setting value of original factory);
- Adjust ” + ” and ” – ” button, could change the corresponding setting temperature, after adjusted, press “Health” button for confirmation;
- At this time, 1 hour will be automatically increased at the timer position on the remote control, (that are “2HOUR” or “3HOUR” or “8HOUR”), the place of setting temperature “88” will display the corresponding temperature of last setting sleep curve and blink;
- Repeat the above step (2)-(3) operation, until 8 hours temperature setting finished, sleep, curve setting finished, at this time, the remote controller will resume the original timer display; temperature display will resume to original setting temperature.
- Sleep 3 the sleep curve setting under Sleep mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep curve, enter into user individuation sleep setting status, but do not change the temperature, press “Health” button directly for confirmation. Note: In the above presetting or enquiry procedure, if continuously within 10s, there is no button pressed, the sleep curve setting within 1 Os, there is no button pressed, the sleep curve setting status will be automatically quit and resume to display the original displaying. In the presetting or enquiry procedure, press ” On/Off ” button, “Mode” button, “Timer” button or “Sleep” button, the sleep curve setting or enquiry status will quit similarly.
Light button
Press this button to control the LED status on the displayer, the
circulation change is as follow: When selecting “
– ” (Auto LED) with remote controller, LED indicator on indoor unit will
adjust the luminance automatically according to the ambient intensity of
illumination.
Function introduction for combination buttons
Energy-saving function
- Under cooling mode, press “Mode” and “Timer” buttons simultaneously to start up or turn off energy-saving function. When energy-saving function is started up, “SE” will be shown on remote controller, and air conditioner will adjust the set temperature automatically according to ex-factory setting to reach to the best energy-saving effect.
- Press “Mode” and “Timer” buttons simultaneously again to exit energy-saving function.
NOTE:
- Under energy-saving function, fan speed is defaulted at auto speed and it can’t be adjusted.
- Under energy-saving function, set temperature can’t be adjusted.
- Sleep function and energy-saving function can’t operate at the same time. If energy-saving function has been set under cool mode, press “Sleep” button will cancel energy-saving function. If sleep function has been set under cool mode, start up the energy saving function will cancel sleep function.
Child lock function
Hold ” On/Off ” and ” – ” buttons simultaneously for 3s to turn on or turn
off child lock function. When child lock function is on, ” ” icon is displayed
on remote controller. If you operate the remote controller, the “ ” icon will
blink three times without sending signal to the unit.
Temperature display switchover function
Under OFF status, hold “Mode” and ” – ” buttons simultaneously for 3s to
switch temperature display between °C and °F.
function
function is for limiting power of the whole unit. Press “Mode” and “Sleep”
buttons simultaneously, the remote controller will circularly display as the
following:
- Maximum power limited under the mode is lower than that of mode.
- If you want to cancel the power limiting function, press “Mode” and “Sleep” buttons simultaneously till the icon in remote controller is not displayed.
- When the remote controller is turned off, power limiting function is cancelled. If you want to activate the function, please repress “Mode” and “Sleep” buttons simultaneously.
- If the current power is lower than the maximum power of mode, then the power will not be limited after entering into such mode.
- For the model with one outdoor unit and two indoor units, if any one of indoor units enters into power limiting function, the outdoor unit will enter into the set limiting power mode of indoor unit; when two indoor units enter into power limiting mode, then the power of outdoor unit will be limited according to the lower power of the two indoor units.
NOTE:
This button is only available for the model with such function.
Indoor ambient temperature or humidity display
By holding ” On/Off ” and ” ” buttons simultaneously , you can see indoor
ambient temperature or indoor ambient humidity on indoor unit’s display. The
setting on remote controller is selected circularly as below:
- When selecting ” ” with remote controller, temperature indicator on indoor unit displays indoor ambient temperature.
- When selecting ” ” with remote controller, temperature indicator on indoor unit displays indoor ambient humidity.
NOTE:
- The ambient humidity value is only for reference.
- Eg: If humidity value is “0%”, there may be malfunction for the humidity detection board. Please contact local service provider.
- There may be some measuring deviation for humidity detection and photo sensitiveness detection.
Clean reminder function of filter
The reminder function is defaulted to be OFF. Hold ” On/Off” and ” ” buttons
simultaneously for 5s to turn it on. The buzzer will give out sound for 0.5s
and the dual-8 nixie tube on the display will be on for 3s; Once the reminder
function is turned on, when the air conditioner has reached to the set time,
the dual-8 nixie tube will flash about 30s when the unit is turned on each
time to remind the user to clean the filter; you can turn off this cycle
reminder by holding ” On/Off” and ” ” buttons simultaneously for 5s and then
the air conditioner will count time again.
NOTE:
- Once the reminder function is turned on, only this cycle reminder can be cleared.
- This function is only available for some models.
Volume control of IOU Buzzer
Press “Mode” and ” ” buttons simultaneously to reduce the sound level of the
indoor unit’ buzzer.
NOTE:
This function is only available for some models.
Fast cool function
Press ” On/Off ” and ” + ” buttons simultaneously under cooling mode can
select 25°C(77°F) fast cooling mode, 16°C(61 °F) fast cooling mode and normal
cooling mode circularly. ” ” icon will be displayed on the remote controller
under fast cooling mode. Once it enters into fast cooling mode, the fan speed
is auto fan and the set temperature is 25°C(77°F) or 16°C(61°F). At this time,
the set temperature flashes to display for 5s. In the flashing period, press ”
- ” or ” – ” button to adjust the set temperature. Press “Fan” button to adjust the fan speed. If the set temperature and the fan speed haven’t been adjusted during that time, the remote controller and the indoor unit will operate under current set temperature and fan speed for 20 minutes. 20 minutes later, the set temperature and the fan speed for the remote controller and the indoor unit will turn to the status before quick cooling.
NOTE:
- If the set temperature and the fan speed have been adjusted during the operation under fast cooling mode, the unit will exit from the fast cooling mode. Then the indoor unit operates continuously under the adjusted status.
- Fast cooling function is only applicable for some models. If this function is unavailable for this indoor unit, 20 minutes later, the remote controller will turn back to the status before fast cooling. Indoor unit operates continuously according to current status. At this time, status of indoor unit and the display status on the remote controller may be different.
- This function is only available for some models.
Auto clean function
Under unit off status, hold “Mode” and “?)” buttons simultaneously for 5s to
turn on or turn off the auto clean function. When the auto clean function is
turned on, indoor unit displays “CL” . During the auto clean process of
evaporator, the unit will perform fast cooling or fast heating. There may be
some noise, which is the sound of flowing liquid or thermal expansion or cold
shrinkage. The air conditioner may blow cool or warm air, which is a normal
phenomenon. During cleaning process, please make sure the room is well
ventilated to avoid affecting the comfort.
NOTE :
- The auto clean function can only work under normal ambient temperature. If the room is dusty, clean it once a month; if not, clean it once every three months. After the auto clean function is turned on, you can leave the room. When auto clean is finished, the air conditioner will enter standby status.
- This function is only available for some models.
Night mode
Under cooling or heating mode, when turning on sleep mode and turn to low
speed or quiet notch, the outdoor unit would enter into night mode.
NOTE:
- When you feel that the cooling and heating effect is poor, please press “Fan” button to other fan speed or press “Sleep” button to exit the night mode.
- The night mode can only work under normal ambient temperature.
- This function is only available for some models.
I FEEL function
- Press “Health” and ” + ” buttons simultaneously to start I FEEL function and ” ” will be displayed on the remote controller. After this function is set, the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature. Press “Health” and ” + ” buttons simultaneously again to turn off I FEEL function and ” ” will disappear.
- Please put the remote controller near user when this function is set. Do not put the remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature. When I FEEL function is turned on, the remote controller should be put within the area where indoor unit can receive the signal sent by the remote controller.
Replacement of batteries in remote controller
- Press the back side of remote controller marked with ” “, as shown in the fig, and then push out the cover of battery box along the arrow direction.
- Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of “+” polar and “-” polar are correct.
- Reinstall the cover of battery box.
NOTICE
- During operation, point the remote control signal sender at the receiving window on indoor unit.
- The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
- Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote controller should be close to indoor unit during operation.
- Replace new batteries of the same model when replacement is required.
- When you don’t use remote controller for a long time, please take out the batteries.
- If the display on remote controller is fuzzy or there’s no display, please replace batteries.