ALPICAIR AWI-20HRDC1A Split Air Conditioner User Manual
- June 15, 2024
- ALPICAIR
Table of Contents
AWI-20HRDC1A Split Air Conditioner
Product Information
Specifications
-
Model: AWI-20HRDC1A, AWI-40HRDC1A, AWI-60HRDC1A1,
AWI-80HRDC1A1 -
Type: Split Air Conditioner indoor unit
Product Usage Instructions
Operation Notices
The Refrigerant
The refrigerant used in this product is essential for its
cooling operation. It is important to handle and store the
refrigerant properly to prevent any leakage or damage. Please refer
to the maintenance section for further instructions on handling the
refrigerant.
Precautions
Before operating the air conditioner, please take note of the
following precautions:
-
Ensure that the power supply is properly connected and
grounded. -
Do not operate the unit with wet hands.
-
Avoid direct exposure to the airflow for extended periods of
time. -
Keep flammable objects away from the unit.
-
Do not block the air inlet or outlet.
-
Regularly clean and maintain the unit as described in the
maintenance section.
Parts Name
The following are the names of the various parts of the air
conditioner:
- Indoor unit
- Remote controller
- Display screen
- Batteries compartment
- Installation pipes
- Power cord
Screen Operation Guide
Buttons on remote controller
The remote controller has several buttons for controlling the
air conditioner. These buttons include:
- Power On/Off
- Mode selection (Cooling, Heating, Fan, etc.)
- Temperature control
- Fan speed control
- Timer settings
Introduction for icons on display screen
The display screen on the air conditioner unit shows various
icons to indicate the current operating mode, temperature, fan
speed, and timer settings. Please refer to the user manual for a
detailed explanation of each icon.
Introduction for buttons on remote
controller
The remote controller has specific buttons for different
functions. These buttons include:
-
Power: Turns the unit on or off.
-
Mode: Selects the desired operating mode (Cooling, Heating,
Fan, etc.). -
Temperature: Adjusts the desired temperature.
-
Fan Speed: Controls the speed of the indoor fan.
-
Timer: Sets the timer for automatic operation.
Introduction for special function
The air conditioner unit may have special functions such as
sleep mode, turbo mode, or energy-saving mode. These functions are
designed to optimize comfort and energy efficiency. Please refer to
the user manual for instructions on how to use these special
functions.
Maintenance
Clean and Maintenance
Regular cleaning and maintenance of the air conditioner unit is
important to ensure its efficient and long-lasting operation.
Follow these steps to clean and maintain the unit:
-
Turn off the power and unplug the unit.
-
Remove the air filters and wash them with water or a mild
detergent. -
Clean the surface of the indoor unit using a soft cloth
dampened with water or a mild detergent. -
Ensure that the unit is completely dry before reassembling the
filters and turning on the power.
Malfunction
Malfunction analysis
If the air conditioner experiences any malfunction, refer to the
troubleshooting section of the user manual for possible solutions.
If the issue persists, contact our customer support for further
assistance.
Installation Notice
Installation dimension diagram
Prior to installing the air conditioner unit, refer to the
installation dimension diagram provided in the user manual. The
diagram will help you determine the appropriate space requirements
for installation.
Safety precautions for installing and relocating the
unit
When installing or relocating the air conditioner unit, it is
important to follow these safety precautions:
-
Ensure that the unit is installed on a stable and level
surface. -
Use appropriate tools and equipment to securely mount the
unit. -
Avoid installing the unit in areas exposed to direct sunlight
or extreme temperatures. -
Ensure proper ventilation around the unit.
Tools for installation
The following tools may be required for the installation of the
air conditioner unit:
- Screwdriver
- Level
- Drill
- Tape measure
Selection of installation location
When selecting the installation location for the air conditioner
unit, consider the following factors:
-
Availability of proper electrical connections
-
Proximity to an external wall for the installation of
pipes -
Avoidance of areas prone to excessive dust or moisture
Requirements for electric connection
Prior to connecting the air conditioner unit to the electrical
supply, ensure that the following requirements are met:
-
Use a dedicated circuit breaker or fuse for the unit.
-
Check the voltage and frequency specifications of the unit and
ensure compatibility with the electrical supply. -
Ensure proper grounding of the unit.
Installation
Installation of indoor unit
To install the indoor unit of the air conditioner, follow these
steps:
-
Select a suitable location based on the installation
requirements mentioned earlier. -
Securely mount the indoor unit on the wall using appropriate
tools and equipment. -
Connect the installation pipes from the indoor unit to the
outdoor unit following the provided instructions. -
Ensure that all connections are properly sealed and
insulated.
Check after installation
After installing the air conditioner unit, perform the following
checks:
-
Ensure that all connections are secure and leak-free.
-
Check the airflow and temperature output to verify proper
operation. -
Test the remote controller to ensure all functions are working
correctly.
Test and Operation
Test operation
Before starting regular operation, perform a test operation to
ensure that the air conditioner unit is functioning properly.
Follow the instructions provided in the user manual for the test
operation.
Attachment
Configuration of connection pipe
The connection pipe is an essential component for the proper
operation of the air conditioner unit. Ensure that the connection
pipe is correctly configured according to the provided
instructions.
Safety operation of flammable refrigerant
If the air conditioner unit uses a flammable refrigerant, it is
important to follow the safety guidelines provided in the user
manual. Ensure proper ventilation and avoid any potential sources
of ignition.
Pipe expanding method
When expanding or modifying the installation pipes, follow the
recommended pipe expanding method provided in the user manual.
Improper pipe expanding can lead to leaks or reduced cooling
efficiency.
FAQ (Frequently Asked Questions)
Q: Can children operate the air conditioner?
A: This appliance is not intended for use by persons (including
children) with reduced physical, sensory, or mental capabilities,
or lack of experience and knowledge, unless they have been given
supervision or instruction concerning the use of the appliance by a
person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
User Manual
Original Instructions Split Air Conditioner indoor unit
Thank you for choosing our product. Please read this Owner’s Manual carefully
before operation and retain it for future reference.
AWI-20HRDC1A AWI-40HRDC1A AWI-60HRDC1A1 AWI-80HRDC1A1
Operation Notices
Content
The Refrigerant…………………………………………………………………………………………1
Precautions……………………………………………………………………………………………… 2
Parts Name………………………………………………………………………………………………7
ScreenOperation Guide
Buttons on remote controller ………………………………………………………………………8
Introduction for icons on display screen………………………………………………………..8
Introduction for buttons on remote controller…………………………………………………9
Introduction for special function…………………………………………………………………15
Operation guide ………………………………………………………………………………………17
Replacement of batteries in remote controller……………………………………………..17
Emergency operation ………………………………………………………………………………18
Maintenance
Clean and Maintenance……………………………………………………………………………18
Malfunction
Malfunction analysis ………………………………………………………………………………..21
Installation Notice
Installation dimension diagram ………………………………………………………………….25
Safety precautions for installing and relocating the unit …………………………….. 26
Tools for installation …………………………………………………………………………………27
Selection of installation location ………………………………………………………………..27
Requirements for electric connection …………………………………………………………28
Installation
Installation of indoor unit…………………………………………………………………………..29
Check after installation …………………………………………………………………………….34
Test and operation
Test operation …………………………………………………………………………………………34
Attachment
Configuration of connection pipe ……………………………………………………………….35 Safety operation of flammable refrigerant……………………………………………………37
Pipe expanding method……………………………………………………………………………39
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
1
Frequency band(s) in which the radio equipment operates 2400MHz-2483.5MHz 2
Maximum radio-frequency power transmitted in the frequency band(s) in which
the radio equipment operates20dBm
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased. They can take this product for
environmental safe recycling. R32: 675
If it needs to install, move or maintain the air conditioner, please contact
dealer or local service
center to conduct it at first. Air conditioner must be installed, moved or
maintained by appointed
unit. Otherwise, it may cause serious damage or personal injury or death.
Explanation of Symbols
DANGER
Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could
WARNING result in death or serious injury.
CAUTION
NOTICE
Indicates a hazardous situation that, if not avoided, may result in minor or
moderate injury.
Indicates important but not hazard-related information, used to indicate risk
of property damage.
Indicates a hazard that would be assigned a signal word WARNING or CAUTION.
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or property
loss is caused by the following reasons.
1.Damage the product due to improper use or misuse of the product; 2.Alter,
change, maintain or use the product with other equipment without abiding
by the instruction manual of manufacturer; 3.After verification, the defect of
product is directly caused by corrosive gas; 4.After verification, defects are
due to improper operation during transportation of
product; 5.Operate, repair, maintain the unit without abiding by instruction
manual or related
regulations; 6.After verification, the problem or dispute is caused by the
quality specification or
performance of parts and components that produced by other manufacturers;
7.The damage is caused by natural calamities, bad using environment or force
majeure.
Appliance filled with flammable gas R32.
Before use the appliance, read the owner’s manual first.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant
circulates in the system. The used refrigerant is the fluoride R32, which is
specially cleaned. The refrigerant is flammable and inodorous. Furthermore, it
can leads to explosion under certain conditions. But the flammability of the
refrigerant is very low. It can be ignited only by fire. Compared to common
refrigerants, R32 is a nonpolluting refrigerant with no harm to the
ozonosphere. The influence upon the greenhouse effect is also lower. R32 has
got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
WARNING
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacture. Should repair be necessary, contact your
nearest authorized Service Centre. Any repairs carried out by unqualified
personnel may be dangerous. The appliance shall be stored in a room without
continuously operating ignition sources. (for example: open flames, an
operating gas appliance or an operating electric heater.) Do not pierce or
burn. Appliance shall be installed, operated and stored in a room with a floor
area larger than X m2. (Please refer to table “a” in section of ” Safety
Operation of Inflammable Refrigerant” for Space X.) Appliance filled with
flammable gas R32. For repairs, strictly follow manufacturer’s instructions
only. Be aware that refrigerants may not contain an odour. Read specialist’s
manual.
1
Precautions
WARNING
Attachment Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage. Must follow the electric
safety regulations when installing the unit. According to the local safety
regulations, use qualified power supply circuit and circuit break. Do install
the circuit break. If not, it may cause malfunction. An all-pole disconnection
switch having a contact separation of at least 3mm in all poles should be
connected in fixed wiring. Including an circuit break with suitable capacity,
please note the following table. Air switch should be included magnet buckle
and heating buckle function, it can protect the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect grounding may cause
electric shock. Don’t use unqualified power cord. Make sure the power supply
matches with the requirement of air conditioner. Unstable power supply or
incorrect wiring may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power
socket. Be sure to cut off the power supply before proceeding any work related
to electricity and safety.
4
Parts Name
Indoor Unit
(Display content or position may be different from above graphics, please
refer to actual products)
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
7
Introduction for buttons on remote controller
Note:
This is a general use remote controller, it could be used for the air
conditioners with multifunction; For some function, which the model don’t
have, if press the corresponding button on the remote controller that the unit
will keep the original running status.
After putting through the power, the air conditioner will give out a sound.
Operation indicator ” ” is ON (red indicator). After that, you can operate the
air conditioner by using remote controller.
Under on status, pressing the button on the remote controller, the signal icon
” ” on the display of remote controller will blink once and the air
conditioner will give out a “di” sound, which means the signal has been sent
to the air conditioner.
Under off status, set temperature and clock icon will be displayed on the
display of remote controller (If timer on, timer off and light functions are
set, the corresponding icons will be displayed on the display of remote
controller at the same time); Under on status, the display will show the
corresponding set function icons.
1 ON/OFF button
Press this button, the unit will be turned on, press it once more, the unit
will be turned off. Sleep function will be canceled, while unit off.
2 FAN button
Press this button, Auto, Low, Medium-low, Medium, Medium-high, High speed can
be circularly selected. After powered on, Auto fan speed is default. Under DRY
mode, Low fan speed only can be set up.
ATUO
Low fan
Medium-low fan
Medium fan
Medium-high fan
High fan
Note:
It’s Low fan speed under Dry mode.
X-FAN functionHold fan speed button for 2s in COOL or DRY mode, the icon ” ”
is displayed and the indoor fan will continue operation for a few minutes in
order to dry the indoor unit even though you have turned off the unit. After
energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or
HEAT mode.
This function indicates that moisture on evaporator of indoor unit will be
blowed after the unit is stopped to avoid mould. Having set X-FAN function on:
After turning off the unit by pressing ON/OFF
button indoor fan will continue running for a few minutes. at low speed. In
this period, Hold fan speed button for 2s to stop indoor fan directly. Having
set X-FAN function off: After turning off the unit by pressing ON/OFF button,
the complete unit will be off directly.
9
Introduction for buttons on remote controller
swing angle will remain original.
If guide louver is stopped when it is swinging up and down, it will remain its
present position.
indicates guide louver swings back and forth in the five places, as shown in
the figure.
8 CLOCK button
Press this button, the clock can be set up, signal blink and display. Within 5
seconds, the value can be adjusted by pressing + or – button, if continuously
press this button for 2 seconds above, in every 0.5 seconds, the value on ten
place of minute will be increased 1. During blinking, repress the Clock button
or Confirm button, signal will be constantly displayed and it denotes the
setting succeeded. After powered on, 12:00 is defaulted to display and signal
will be displayed. If there is signal be displayed that denotes the current
time value is Clock value, otherwise is Timer value.
9 TIMER ON/TIMER OFF button
Timer On setting: Signal “ON” will blink and display, signal will conceal, the
numerical section will become the timer on setting status. During 5 seconds
blink, by pressing + or – button to adjust the time value of numerical
section, every press of that button, the value will be increased or decreased
1 minute. Hold pressing + or button, 2 seconds later, it quickly change, the
way of change is: During the initial 2.5 seconds, ten numbers change in the
one place of minute, then the one place is constant, ten numbers change in the
tens place of minute at 2.5 seconds speed and carry. During 5s blink, press
the Timer button, the timer setting succeeds. The Timer On has been set up,
repress the timer button, the Timer On will be canceled. Before sett ing the
Timer, please adjust the Clock to the current actual time. One press this key
to enter into TIMER OFF setup, in which case the TIMER OFF icon will blink.
The method of setting is the same as for TIMER ON.
10 TEMP button
Press this button, you can see indoor set temperature, indoor ambient
temperature or outdoor ambient temperature on indoor unit’s display. The
setting on remote controller is selected circularly as below:
no display
When selecting ” ” with remote controller or no display, temperature indicator
on indoor unit displays set temperature; When selecting ” ” with remote
controller, temperature indicator on indoor unit displays indoor ambient
temperature; When selecting ” ” with remote controller, temperature indicator
on indoor unit displays outdoor ambient temperature. 3s later it will return
to the setting temperature or it depends on the other received signal within
3s.
11
Introduction for buttons on remote controller
Attention: When displaying the outdoor ambient, the displaying range is 0-60
When it goes beyond the range, it keeps the threshold data (the smallest–0 and
the largest 60). Warm tips: When operating buttons on the cover please make
sure the cover is
closed completely.
Note: Outdoor temperature display is not available for some models. At that
time,
indoor unit receives ” ” signal, while it displays indoor set temperature.
11 / button
Press this button to achieve the on and off of health and scavenging functions
in operation status. Press this button for the first time to start scavenging
function; LCD displays ” ” . Press the button for the second time to start
health and scavenging functions simultaneously; LCD displays ” ” and ” “.
Press this button for the third time to quit health and scavenging functions
simultaneously. Press the button for the fourth time to start health function;
LCD display ” ” . Press this button again to repeat the operation above. NOTE:
This function is applicable to partial of models.
12 I FEEL button
Press this button once, to turn on the I FEEL function, then the figure of “I
FEEL” will be displayed, after every press of other function button, every
200ms to send I FEEL once, after this function started, the remote controller
will send temperature to the main un it in every 10 minutes. When repress this
button, this function will be turned off. When I FEEL function is turned on,
the remote controller should be put within the area where indoor unit can
receive the signal sent by the remote controller.
13 LIGHT button
Press this button at unit On or Off status, Light On and Light Off can be set
up. After powered on, Light On is defaulted.
14 WiFi button
Press ” WiFi ” button to turn on or turn off WiFi function. When WiFi function
is turned on, the ” WiFi ” icon will be displayed on remote controller; Under
status of remote controller off, press “MODE” and ” WiFi ” buttons
simultaneously for 1s, WiFi module will restore to factory default setting.
This function is only available for some models.
12
Introduction for buttons on remote controller
15 QUIET button
Press this button, the Quiet status is under the Auto Quiet mode (display ” ”
and “Auto” signal) and Quiet mode (display ” ” signal) and Quiet OFF (there is
no signal of ” ” displayed), after powered on, the Quiet OFF is defaulted.
Under the Quiet mode (Display ” ” signal). The Quiet function is only
available for some models.
16 SLEEP button
Press this button, can select Sleep 1 ( ), Sleep 2 ( ), Sleep 3 ( ) and cancel
the Sleep, circulate between these, after electrified, Sleep Cancel is
defaulted. Sleep 1 is Sleep mode 1, in Cool modes: sleep status after run for
one hour, the main unit setting temperature will increase 1, 2 hours, setting
temperature increased 2 , the unit will run at this setting temperature; In
Heat mode:sleep status after run for one hour, the setting temperature will
decrease 1 , 2 hours, setting temperature will decrease 2, then the unit will
run at this setting temperature. Sleep 2 is sleep mode 2, that is air
conditioner will run according to the presetting a group of sleep temperature
curve. In Cool mode: (1) When setting the initial temperature 16-23, after
turned on Sleep function,
the temperature will be increased 1 in every hour, after 3 the temperature
will be maintained, after 7hours, the temperature will be decreased 1, after
that the unit will keep on running under this temperature; (2) When setting
the initial temperature 24-27, after turned on Sleep function, the temperature
will be increased 1 in every hour, after 2 the temperature will be maintained,
after 7hours, the temperature will be decreased 1, after that the unit will
keep on running under this temperature; (3) When setting the initial
temperature 28-29, after turned on Sleep function, the temperature will be
increased 1 in every hour, after 1 the temperature will be maintained, after
7hours, the temperature will be decreased 1, after that the unit will keep on
running under this temperature; (4) When setting the initial temperature 30,
under this temperature setting, after 7hours, the temperature will be
decreased 1, after that the unit will keep on running under this temperature;
In Heat mode: (1) Under the initial presetting temperature 16, it will run
under this setting tem-
perature all along.
13
Introduction for buttons on remote controller
(2) Under the initial presetting temperature17-20, after Sleep function
started up, the temperature will decrease 1 in every hour, after 1 decreased,
this temperature will be maintained.
(3) Under the initial presetting temperature 21-27, after Sleep function
started up, the temperature will decrease 1 in every hour, after 2 decreased,
this temperature will be maintained.
(4) Under the initial presetting temperature 28-30, after Sleep function
started up, the temperature will decrease 1 in every hour, after 3 decreased,
this temperature will be maintained.
Sleep 3 – the sleep curve setting under Sleep mode by DIY: (1) Under Sleep 3
mode, press “Turbo” button for a long time, remote controller en-
ters into user individuation sleep setting status, at this time, the time of
remote controller will display “1hour”, the setting temperature “88” will
display the corresponding temperature of last setting sleep curve and blink
(The first entering will display according to the initial curve setting value
of original factory); (2) Adjust “+” and “-” button, could change the
corresponding setting temperature, after adjusted, press “Turbo” button for
confirmation; (3) At this time, 1hour will be automatically increased at the
timer position on the remote controller, (that are “2hours” or “3hours” or
“8hours”), the place of setting temperature “88” will display the
corresponding temperature of last setting sleep curve and blink; (4) Repeat
the above step (2)~(3) operation, until 8hours temperature setting finished,
sleep curve setting finished, at this time, the remote controller will resume
the original timer display; temperature display will resume to original
setting temperature. Sleep3 – the sleep curve setting under Sleep mode by DIY
could be inquired: The user could accord to sleep curve setting method to
inquire the presetting sleep curve, enter into user individuation sleep
setting status, but do not change the temperature, press “Turbo” button
directly for confirmation. Note: In the above presetting or enquiry procedure,
if continuously within10s, there
is no button pressed, the sleep curve setting status will be automatically
quit and resume to display the original displaying. In the presetting or
enquiry procedure, press “ON/OFF” button, “Mode” button, “Timer” button or
“Sleep” button, the sleep curve setting or enquiry status will quit similarly.
14
Introduction for special function
About AUTO RUN
When AUTO RUN mode is selected, the unit will be in accordance with the room
temp. automatically to select the suitable running method and to make ambient
comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or
heat quickly so that the ambient temp. approachs the preset temp. as soon as
possible.
About lock
Press + and – buttons simultaneously to lock or unlock the keyboard. If the
remote controller is locked, the icon will be displayed on it, in which case,
press any button, the mark will flicker for three times. If the keyboard is
unlocked, the mark will disappear.
About swing up and down
1. Press swing up and down button continuously more than 2s, the main unit
will swing back and forth from up to down , and then loosen the button, the
unit will stop swing and present position of guide louver will be kept
immediately.
2. Under swing up and down mode, when the status is switched from off to , if
press this button again 2s later, status will switch to off status directly;
If press this button again within 2s, the change of swing status will also
depend on the circulation sequence stated above.
About swing left and right
1. Press swing left and right button continuously more than 2s, the main unit
will swing back and forth from left to right, and then loosen the button, the
unit will stop swing and present position of guide louver will be kept
immediately.
2. Under swing left and right mode, when the status is switched from off to ,
if press this button again 2s later, status will switch to off status
directly; if press this button again within 2s, the change of swing status
will also depend on the circulation sequence stated above.
15
Operation guide
General operation 4
1. After powered on, press ON/OFF button, the unit will start
to run. (Note: When it is powered on, the guide louver of 3
5
main unit will close automatically.)
2
2. Press MODE button, select desired running mode.
3. Pressing + or – button, to set the desired temperature.
1
4. Pressing FAN button, set fan speed, can select AUTO FAN,
LOW, MEDIUM-LOW, MEDIUM, MEDIUM-HIGH and HIGH.
5. Pressing and button, to select the swing.
Optional operation
4
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set the
2
scheduled timer on or timer off.
3. Press LIGHT button, to control the on and off of the
3
1
displaying part of the unit (This function may be not
available for some units).
4. Press TURBO button, can realize the ON and OFF of
TURBO function.
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction. 2. Replace two 7# (AAA
1.5V) dry batteries, and
make sure the position of “+” polar and “-” polar are correct. 3. Reinstall
the cover of battery box.
reinstall
battery
remove
Cover of battery box
NOTICE
During operation, point the remote control signal sender at the receiving
window on indoor unit.
The distance between signal sender and receiving window should be no more than
8m, and there should be no obstacles between them.
Signal may be interfered easily in the room where there is fluorescent lamp or
wireless telephone; remote controller should be close to indoor unit during
operation.
Replace new batteries of the same model when replacement is required. When you
don’t use remote controller for a long time, please take out the
batteries. If the display on remote controller is fuzzy or there’s no display,
please
replace batteries.
17
Emergency operation
If remote controller is lost or damaged, please use aux. button to turn on or turn off the air conditioner. The operation in details is as below:
air conditioner. When the air conditioner is turned on, it will operate under auto mode.
panel
aux. button
WARNING:
Use insulated object to press the auto button
Clean and Maintenance
WARNING
Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
Do not wash the air conditioner with water to avoid electric shock. Do not use
volatile liquid to clean the air conditioner. Do not use liquid or corrosive
detergent clean the appliance and do not splash
water or other liquid onto it, otherwise, it may damage the plastic
components, even cause electric shock.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry
cloth or wet cloth to wipe it.
NOTICE:
Do not remove the panel when cleaning it.
18
Clean and Maintenance
1 Open panel Pull out the panel to a certain
3 Use dust catcher or water to
the water (below 45 ) to clean it, and then put it in a shady and cool place to dry.
2
4
panel cover tightly.
WARNING
operation environment, clean frequency can be increased.
19
Malfunction analysis
Phenomenon
Check items
Solution
Odours are emitted
Whether there’s odour source, Eliminate the odour source. such as furniture and cigarette, etc.
Air conditio- Whether there’s interference,
ner operates such as thunder, wireless
abnormally
devices, etc.
Disconnect power, put back power, and then turn on the unit again.
“Water noise
Air conditioner is turned on or turned off just now?
The noise is the sound of
the unit, which is a normal phenomenon.
Cracking noise
Air conditioner is turned on or turned off just now?
This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature.
23
Installation dimension diagram
25
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant
circuit free from air or substances other than the specified refrigerant. Any
presence of air or other foreign substance in the refrigerant circuit will
cause system pressure rise or compressor rupture, resulting in injury.
When installing or moving this unit, do not charge the refrigerant which is
not comply with that on the nameplate or unqualified refrigerant. Otherwise,
it may cause abnormal operation, wrong action, mechanical malfunction or even
series safety accident.
When refrigerant needs to be recovered during relocating or repairing the
unit, be sure that the unit is running in cooling mode.Then, fully close the
valve at high pressure side (liquid valve).About 30-40 seconds later, fully
close the valve at low pressure side (gas valve), immediately stop the unit
and disconnect power. Please note that the time for refrigerant recovery
should not exceed 1 minute. If refrigerant recovery takes too much time, air
may be sucked in and cause pressure rise or compressor rupture, resulting in
injury.
During refrigerant recovery, make sure that liquid valve and gas valve are
fully closed and power is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is
not yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely connected
before the compressor starts running. If compressor starts running when stop
valve is open and connection pipe is not yet connected, air will be sucked in
and cause pressure rise or compressor rupture, resulting in injury.
Prohibit installing the unit at the place where there may be leaked corrosive
gas or flammable gas. If there leaked gas around the unit, it may cause
explosion and other accidents.
Do not use extension cords for electrical connections. If the electric wire is
not long enough, please contact a local service center authorized and ask for
a proper electric wire. Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the indoor
and outdoor units. Firmly clamp the wires so that their terminals receive no
external stresses. Electric wires with insufficient capacity, wrong wire
connections and insecure wire terminals may cause electric shock or fire.
26
Tools for installation
1 Level meter 4 Drill head
2 Screw driver 5 Pipe expander
3 Impact drill 6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
13 Inner hexagon spanner
14 Measuring tape
Note:
Please contact the local agent for installation.
Selection of installation location
Basic requirement
Installing the unit in the following places may cause malfunction. If it is
unavoidable,
please consult the local dealer: 1. The place with strong heat sources,
vapors, flammable or explosive gas, or
volatile objects spread in the air. 2. The place with high-frequency devices
(such as welding machine, medical
equipment). 3. The place near coast area. 4. The place with oil or fumes in
the air. 5. The place with sulfureted gas. 6. Other places with special
circumstances. 7. The appliance shall not be installed in the laundry. 8. It’s
not allowed to be installed on the unstable or motive base structure (such
as truck) or in the corrosive environment (such as chemical factory).
Indoor unit
1. There should be no obstruction near air inlet . 2. Select a location where
the condensation water can be dispersed easily and
won’t affect other people. 3. Select a location which is convenient to connect
the outdoor unit and near the
power socket. 4. Select a location which is out of reach for children. 5. The
location should be able to withstand the weight of indoor unit and won’t
increase noise and vibration. 6. The appliance must be installed 2.5m above
floor. 7. Don’t install the indoor unit right above the electric appliance. 8.
Please try your best to keep way from fluorescent lamp.
27
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
air switch. 3. Make sure the power supply matches with the requirement of air
conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install
proper power supply cables before using the air conditioner. 4. Properly
connect the live wire, neutral wire and grounding wire of power socket. 5. Be
sure to cut off the power supply before proceeding any work related to
electricity and safety. For models with a power plug, make sure the plug is
within reach after installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer,
its
8. The temperature of refrigerant circuit will be high, please keep the
interconnection cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring
regulations. 10. Appliance shall be installed, operated and stored in a room
with a floor area
larger than Xm2. (Please refer to table “a” in section of ” Safety Operation
of Inflammable Refrigerant” for Space X.)
Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people and
material. Details to this refrigerant are found in chapter “refrigerant”.
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can’t be
used for other purposes. 3. The grounding resistance should comply with
national electric safety regulations. 4. The appliance must be positioned so
that the plug is accessible. 5. An all-pole disconnection switch having a
contact separation of at least 3mm in
28
Installation of indoor unit
Step one: choosing installation location
rm it with the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position
with the
plastic expansion particles in the holes. 3. Fix the wall-mounting frame on
the wall with tapping screws (ST4.2X25TA) and
.
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet
pipe. The position of piping hole should be a little lower than the wall-
mounted frame, shown as below.
AWI-20HRDC1A, AWI-40HRDC1A:
Wall Mark in the middle of it
Space to the wall above 150mm
Level meter
Wall
Space to the wall above 150mm
Left 55mm
Rear piping hole
Right 55mm Rear piping hole
AWI-60HRDC1A1,AWI-80HRDC1A1:
Wall Mark in the middle of it
Space to the wall above 150mm
Level meter
Wall
Space to the wall above 150mm
Left 70mm
Rear piping hole
Right 70mm Rear piping hole
2. Open a piping hole with the diameter of 55 or 70 on the selected outlet pipe position.In order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.
29
Installation of indoor unit
2. Make the power connection wire go through the cable-cross hole at the back of indoor unit and then pull it out from the front side.
cable-cross hole
power connection wire
3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw and then fix the power connection wire with wire clip.
N(1) 2 3
blue black brown yellowgreen
Outdoor unit connection
Note: the wiring board is for reference only, please refer to the actual one.
4. Put wiring cover back and then tighten the screw. 5. Close the panel.
Note:
All wires of indoor unit and outdoor unit should be connected by a
professional.
for a new one. Avoid extending the wire by yourself.
installation. For the air conditioner without plug, an air switch must be
installed in the line.
The air switch should be all-pole parting and the contact parting distance
should be more than 3mm.
32
Check after installation
Items to be checked
Possible malfunction
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
(heating) capacity.
It may cause condensation and water dripping.
Is water drained well?
It may cause condensation and water dripping.
Is the voltage of power supply accord-
ing to the voltage marked on the
It may cause malfunction or damaging
nameplate?
the parts.
Is electric wiring and pipeline installed It may cause malfunction or damaging
correctly?
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the speci- It may cause malfunction or damaging the parts.
Is there any obstruction in the air inlet
and outlet?
(heating) capacity.
The dust and sundries caused during It may cause malfunction or damaging
installation are removed?
the parts.
The gas valve and liquid valve of connection pipe are open completely? (heating) capacity.
Is the inlet and outlet of piping hole been covered?
It may cause insufficient cooling (heating) capacity or waster eletricity.
Test operation
1. Preparation of test operation
The client approves the air conditioner.
Specify the important notes for air conditioner to the client.
2. Method of test operation
Put through the power, press ON/OFF button on the remote controller to start
operation.
Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not. If the ambient temperature is lower than 16 , the air conditioner can’t
start cooling.
34
Configuration of connection pipe
1. Standard length of connection pipe 5ma7.5ma8m
2. Min. length of connection pipe For the unit with standard connection pipe
of 5m, there is no limitation for the min. length of connection pipe. For the
unit with standard connection pipe of 7.5m and 8m, the min. length of
connection pipe is 3m.
3. The calculation method of additional refrigerant oil and refrigerant
charging amount after prolonging connection pipe After the length of
connection pipe is prolonged for 10m at the basis of standard length, you
should add 5ml of refrigerant oil for each additional 5m of connection pipe.
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe): (1) Additional refrigerant charging amount= prolonged length
of liquid pipe × additional refrigerant charging amount per meter (2) Basing
on the length of standard pipe, add refrigerant according to the requirement
as shown in the table. The additional refrigerant charging amount per meter is
different according to the diameter of liquid pipe. See Sheet 2.
35
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:
A: Cut the pipe
the distance of indoor unit and outdoor unit. Cut the required pipe with pipe
cutter.
E: Expand the port Expand the port with expander.
expander
hard mold
pipe
pipe pipe cutter
leaning
uneven burr
B: Remove the burrs Remove the burrs with shaper and
prevent the burrs from getting into the pipe.
pipe shaper
downwards
C: Put on suitable insulating pipe D: Put on the union nut Remove the union
nut on the indoor
connection pipe and outdoor valve; install the union nut on the pipe.
union pipe
Note: “A” is different according to the
diameter, please refer to the sheet below:
Outer diameter (mm)
A(mm) Max Min
6 – 6.35(1/4″) 1.3
0.7
9.52(3/8″)
1.6
1.0
12-12.7(1/2″) 1.8
1.0
15.8-16(5/8″) 2.4
2.2
F: Inspection Check the quality of expanding port.
If there is any blemish, expand the port again according to the steps above.
smooth surface
improper expanding
pipe
leaning damaged surface
the length is equal
crack
uneven thickness
39
User Manual
Original Instructions Split Air Conditioner outdoor unit
Thank you for choosing our product. Please read this Owner’s Manual carefully
before operation and retain it for future reference.
Precautions
WARNING
For the air conditioner with plug, the plug should be reachable after
finishing installation.
For the air conditioner without plug, an circuit break must be installed in
the line.
If you need to relocate the air conditioner to another place, only the
qualified person can perform the work. Otherwise, it may cause personal injury
or damage.
Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Instructions for installation and use of this product are provided by the
manufacturer.
Working temperature range
For some models:
Indoor side DB/WB( ) Outdoor side DB/WB( )
Maximum cooling
32/23
52/32
Maximum heating
27/-
24/18
NOTICE:
The operating temperature range (outdoor temperature) for cooling only unit is
-18 ~ 52 ; for Low-temperature heat pump unit is -30 ~ 52 .
6
Installation of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure. 2. Fix the
support of outdoor unit on the selected location with expansion screws.
Note:
installing the outdoor unit. Make sure the support can withstand at least
four times of the unit weight. The outdoor unit should be installed at least
joint. (for the model with heating tube, the installation height should be no
less than 20cm.)
For the unit with cooling capacity of 2300W ~5000W, 6 expansion screws are
needed; for the unit with cooling capacity of 6000W ~8000W, 8 expansion screws
are needed; for the unit with cooling capacity of 10000W ~16000W, 10 expansion
screws are needed.
at least 3cm above the floor
Configuration of connection pipe
1. Standard length of connection pipe 5ma7.5ma8m
2. Min. length of connection pipe For the unit with standard connection pipe
of 5m, there is no limitation for the min. length of connection pipe. For the
unit with standard connection pipe of 7.5m and 8m, the min. length of
connection pipe is 3m.
3. The calculation method of additional refrigerant oil and refrigerant
charging amount after prolonging connection pipe After the length of
connection pipe is prolonged for 10m at the basis of standard length, you
should add 5ml of refrigerant oil for each additional 5m of connection pipe.
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe): (1) Additional refrigerant charging amount= prolonged length
of liquid pipe × additional refrigerant charging amount per meter (2) Basing
on the length of standard pipe, add refrigerant according to the requirement
as shown in the table. The additional refrigerant charging amount per meter is
different according to the diameter of liquid pipe. See Sheet 2.
19
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:
A: Cut the pipe Confirm the pipe length according to
the distance of indoor unit and outdoor unit. Cut the required pipe with pipe
cutter.
E: Expand the port Expand the port with expander.
expander
hard mold
pipe
pipe pipe cutter
leaning
uneven burr
B: Remove the burrs Remove the burrs with shaper and
prevent the burrs from getting into the pipe.
pipe shaper
downwards
C: Put on suitable insulating pipe D: Put on the union nut Remove the union
nut on the indoor
connection pipe and outdoor valve; install the union nut on the pipe.
union pipe
Note: “A” is different according to the
diameter, please refer to the sheet below:
Outer diameter (mm)
A(mm) Max Min
6 – 6.35(1/4″) 1.3
0.7
9.52(3/8″)
1.6
1.0
12-12.7(1/2″) 1.8
1.0
15.8-16(5/8″) 2.4
2.2
F: Inspection Check the quality of expanding port.
If there is any blemish, expand the port again according to the steps above.
smooth surface
improper expanding
pipe
leaning damaged surface
the length is equal
crack
uneven thickness
21