ALPICAIR Eco X Series Split Type Wall Mounted Air-Conditioner
Safet Precautions
Incorrect installation or operation by not following these instructions may
cause harm or damage to people, properties, etc.
The seriousness is classified by the following indications
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to properties. :
WARNING
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
(Only for the AC with CE-MARKING)
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
(Except for the AC with CE-MARKING)
-
The air conditioner must be grounded. Incomplete ground ing may result in electric shocks.
Do not connect the earth wire to the gas pipeline, water pipeline, lightning rod, or telephone earth wire. -
Always switch off the device and cut the power supply when the unit is not in use for long time so as to ensure safety.
-
Take care not let the remote control and the indoor unit watered or being too wet.
-
If the power supply cable is damaged, it must be replaced by the manufacture or its service agent or a similar qualified person.
-
Don’t cut off main power switch during operating or with wet hands.
-
Don’t share the socket with other electric appliance.
-
Always switch off the device and cut the power supply before performing any maintenance or cleaning.
Otherwise, it may cause electric shock or damage. -
Don’t pull the power cable
The damage of pulling power cord will cause serious electric shock. -
An earth leakage breaker with rated capacity must be installed to avoid possible electric shocks.
-
Don’t install air conditioner in a place where there is flammable gas or liquid. The distance between them should above 1 m.
It may cause fire even explosion. -
Don’t use liquid or corrosive cleaning agent wipe the air conditioner and sprinkle water or other liquid either.
Doing this may cause electric shock or damage to the unit. -
Don’t attempt to repair the air conditioner by yourself.
Incorrect repairs may cause fire or explosion. Contact a qualified service technician for all service requirement. -
Don’t use air conditioner in lightning storm weather.
Power supply should be cut in time to prevent the occurrence of danger. -
Don’t put hands or any objects into the air inlets or outlets.
This may cause personal injury or damage to the unit. -
Please note whether the installed stand is firm enough or not.
If ii is damaged, ii may lead to the fall of the unit and cause the injury. -
Don’t block air inlet or air outlet.
Otherwise, the cooling or heating capacity will be weakened, even cause system stop operating. -
Don’t let the air conditioner blow against the heater appliance.
Otherwise it will lead to incomplete combustion, thus causing poisoning. -
The appliance shall be installed in accordance with national wiring regulations.
This product contains fluorinated greenhouse gases. Refrigerant leakage
contributes to climate change. Refrigerant with lower global warming potential
(GWP) would contribute less to global warming than a refrigerant with higher
GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid
with a GWP equal to [2088]. This means that if 1 kg of this refrigerant fluid
would be leaked to the atmosphere, the impact on global warming would be
[2088] times higher than 1 kg of CO2 , over a period of 100 years. Never try
to interfere with the refrigerant circuit yourself or disassemble the product
yourself and always ask a professiona. The specification of the fuse are
printed on the circuit board, such as: 3.15A/250V AC, etc.
WEEE Warning
Meaning of crossed out wheeled dustbin: Do not dispose of electrical
appliances as unsorted municipal waste, use separate collection facilities.
Contact you local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into the food
chain, damaging your health and well-being. When replacing old appliances with
new ones, the retailer is legally obligated to take back your old appliance
for disposals at least free of charge.
CAUTION
-
Don’t open the windows and doors for long time when the air conditioner is running.
Otherwise, the cooling or heating capacity will be weakened. -
Don’t stand on the top of the outdoor unit or place heavy things on it.
This cloud cause personal injuries or damage the unit. -
Don’t use the air conditioner for other purposes, such as drying clothes, preserving foods,etc.
-
Don’t apply the cold air to the body for a long time.
It will deteriorate your physical conditions and cause health problems. -
Set the suitable temperature.
Appropriate adjustments of the setting temperature can prevent the waste of electricity. -
If your air conditioner is not fitted with a supply cord and a plug, an all-pole switch must be installed in the fixed wiring and the distance between contacts should be no less than 3.0 mm.
If your air conditioner is permanently connected to the fixed wiring, a
residual current device (RCD) having rated residual operating current not
exceeding 30 mA should be installed in the fixed wiring.
The power supply circuit should have leakage protector and air switch of which
the capacity should be more than1 .5 times of the maximum current.
Regarding the installation of the air conditioners, please refer to the below
paragraphs in this manual.
NOTICE FOR USAGE
The conditions of unit can’ t normally run
Within the temperature range provided in following table, the air conditioner may stop running and other anomalies may arise.
- When the temperature is too high, the air conditioner may activate the automatic protection device, so that the air conditioner could be shut down.
- When the temperature is too low, the heat exchanger of the air conditioner may freeze, leading to water leakage or other malfunction.
- In long-term cooling or dehumidification with a relative humidity of above 80% (doors and windows are open), there may be water condenses or dripping near the air outlet.
- T1 and T3 refer to ISO 5151.
Notes for heating
- The fan of the indoor unit will not work immediately when the heating is started to avoid blowing out cool air.
- When it is cold and wet outside, the outdoor unit will develop frost over the heat exchanger which will compromise the heating capacity. This is when the air conditioner will start defrost.
- During defrost, the air conditioner will stop heating for about 5-12 minutes.
- Vapor may come out from the outdoor unit during defrost. This is not a malfunction, but a result of fast defrost.
- eating will resume after defrost is complete.
Notes for turning off
- When the air conditioner is turned off, the main controller will automatically decide whether to stop immediately or after running for dozens of seconds with lower frequency and lower air speed.
Emergency operation
- If the remote controller is lost or broken, use force switch button to operate the air conditioner.
- If this button is pushed with the unit OFF, the air conditioner will operate in Auto mode.
- If this button is pushed with the unit ON, the air conditioner will stop running.
Airflow direction adjustment
- Use up-down swing and left-right swing buttons on the remote controller to adjust the airflow direction. Refer to the operation manual of the remote ontroller for detail.
- For models without left-right swing function, the air vent has to be moved manually.
Note: Move the air vents before the unit is in operation, or your finger might be injured.
Never place your hand into the air inlet or outlet when the air conditioner is in operation.
ATTENTION
If the equipment emissions cannot meet the technical requirement of IEC
61000-3-3, following attention should be take care.
Attention: This appliance can be connected only to a supply with system
impedance no more than Zmax. In case necessary, please consult your supply
authority for system impedance information.
=LK700,LF,LH,Ll,LM,LN,LR,LU,LS,LD,LP, LQ,LB,LO,LC,LE,LL,LV800,LT,LW,LZ
,ULK700,ULF, ULH,ULM,ULN,ULl,ULS,ULU,ULD,ULP,ULR, ULQ,ULB,ULO,ULC,ULE,ULL,ULV800,ULT,ULW, ULZ,QLK700,QLF,QLH,QLM,QLN,QLl,QLS,QLU,QLD,QLP,QLR,QLQ,QLB,QLO,QLC,QLE,QLL ,QLV800,QLT,QLW,QLZ,DA,DB,DC,DE,DF,DH,DI
names of each art
Note: All the illustrations in this manual are for explanation purpose only.
Your air conditioner may be slightly different. The actual shape shall
prevail.
are Plug, They are WIFI optional.the subject function, actual to unit change
Negative-ion shall without prevail. function, notice and for Vertical future
and horizontal improvement. swing function both
Clean and care
WARNING
- Before the cleaning of the air conditioner, it must be shut down and the electricity must be cut off for more than 5 minutes, otherwise there might be the risk of electric shocks.
- Do not wet the air conditioner, which can cause an electric shock. Make sure not to rinse the air conditioner with water under any circumstances.
- Volatile liquids such as thinner or gasoline will damage the air conditioner housing, therefore please clean the housing of air conditioner only with soft dry cloth and damp cloth moistened with neutral detergent.
- In the course of the usage, pay attention to cleaning the filter regularly, to prevent the accumulation of dust which may affect the air conditioner performance. If the service environment of the air conditioner is dusty, correspondingly increase the number of times of cleaning. After removing the filter, do not touch the fin part of the indoor unit with the finger, so as to avoid scratching it.
Clean the panel
When the panel of the indoor unit is contaminated, clean it gently with a
wrung towel using tepid water below 45 C, and do not remove the panel while
cleaning.
Clean the air filter
Remove the air filter
- Use both hands to open the panel for an angle from both ends of the panel in accordance with the direction of the arrow.
- Release the air filter from the slot and remove it.
Clean the Air Filter
Use a vacuum cleaner or water to rinse the filter, and if the filter is very dirty (for example, with greasy dirt), clean it with warm water (below 45 C) with mild detergent , and then put the filter in the shade to dry in the air.
Mount the Filter
- Reinstall the dried filter in reverse order of removal, then cover and lock the panel.
Check before using
- Check whether all the air inlets and outlets of the units are unblocked.
- Check whether there is blocking in the water outlet of the drain pipe, and immediately clean it up if any.
- Check the ground wire is reliably grounded.
- Check whether the remote control batteries are installed, and whether the power is sufficient.
- Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our local service center.
Maintain after using
- Cut off the power source of the air conditioner, turn off the circuit breaker and remove the batteries from the remote control.
- Clean the filter and the unit body.
- Remove the dust and debris from the outdoor unit.
- Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our local service center.
troubleshooting
CAUTION
- Do not repair the air conditioner by yourself as wrong maintenance may cause electric shock or fire, please contact the authorized service center and let the professionals conduct the maintenance, and checking the following items prior to contacting for maintenance can save your time and money.
Immediately stop all operations and cut off the power supply , contact our Service center locally in following situations.
- Shrill sound is heard or Unpleasant odor is emitted during the operation.
- There is an abnormal heat in power supply cord and power plug.
- Accidentally pour impurities or water into the machine or the remote control.
- Air switch or protection switch often breaks.
notices for installation
Important Notices
- Before installating, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may not solved,due to discommodious contact.
- The air conditioner must be installed by professionals according to the national wiring rules and this manual.
- To move and install air conditioner to another place, please contact our local special service center.
Requirements For Installation Position
- Avoid places of inflammable or explosive gas leakage or where there are strongly aggressive gases.
- Avoid places subject to strong artificial electric/magnetic fields.
- Avoid places subject to noise and resonance.
- Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct sunshine or high temperature heat sources).
- Avoid places within the reach of children.
- Shorten the connection between the indoor and outdoor units.
- Select where it is easy to perform service and repair and where the ventilation good.
- The outdoor unit shall not be installed in any way that could occupy an aisle, stairway, exit, fire escape, catwalk or any other public area.
- The outdoor unit shall be installed as far as possible from the doors and windows of the neighbors as well as the green plants.
Requirements of the mounting structure
- The mounting rack must meet the relevant national or industrial standards in terms of strength with welding and connection areas rustproofed.
- The mounting rack and its load carry surface shall be able to withstand 4 times or above the weight of the unit, or 200kg, whichever is heavier.
- The mounting rack of the outdoor unit shall be fastened with expansion bolt.
- Ensure the secure installation regardless of what type of wall on which it is installed, to prevent potential dropping that could hurt people.
Electrical Safety Requirements
-
Be sure to use the rated voltage and air conditioners dedicated circuit for the power supply, and the power cable diameter must meet the national requirements.
-
When the maximum current of air conditioner is 16A, it must use the air switch or leakage protection switch equipped with protection devices.
-
The normal operating range is 90%-110% of the local rated voltage
-
The minimum clearance between the air conditioner and the combustibles is 1.5 m.
-
The Interconnection cord connect the indoor and outdoor units. You must first choose the right cable size before preparing it for connection.
-
Cable Types:
Outdoor Power Cable: H0?RN-F or H05RN-F;
Interconnection cord: H0?RN-F or H05RN-F; -
Minimum Cross-Sectional Area of Power Cable and interconnection cord
-
The size of the interconnection cord, power cable, fuse, and switch needed is determined by the maximum current of the unit The maximum current is indicated on the nameplate located on the side panel of the unit. Refer to this nameplate to choose the right cable, fuse, or switch.
-
Note: Core number of cable refer to the detailed wiring diagram adhered on the unit which you purchased.
Requirements for operations at raised height
- When carrying out installation at 2m or higher above the base level, safety belts must be worn and ropes of sufficient strength be securely fasten to the outdoor unit, to prevent falling that could cause personal injury or death as well as property loss.
Grounding Requirements
- The air conditioner is the type I electrical appliance and must ensure a reliable grounding.
- Do not connect the grounding wire to a gas pipe, water pipe, lightning rod, telephone line, or a circuit poorly grounded to the earth.
- The grounding wire is specially designed and shall not be used for other purpose, nor shall it be fastened with a common tapping screw.
Others
- The connection method of the air conditioner and the power cable and the interconnection method of each independent element shall be subject to the wiring diagram affixed to the machine.
- The model and rating value of the fuse shall be subject to the silkscreen on corresponding controller or fuse sleeve.
Packing list [
](https://manuals.plus/wp-content/uploads/2022/08/ALPICAIR-Eco-X -Series-Split-Type-Wall-Mounted-Air-Conditioner-fig-27.png)
NOTE: Interconnection cord and sound deadening pads is optional accessorie.
All accessories shall be subject to actual packaging material, and if there is
any difference, please understand.
Installation for indoor unit[
](https://manuals.plus/wp-content/uploads/2022/08 /ALPICAIR-Eco-X-Series-Split-Type-Wall-Mounted-Air-Conditioner-fig-28.png)
Mounting plate
- The wall for installation of the indoor unit shall be hard and firm, so as to prevent vibration.
- Use the”+” type screw to fasten the peg board, horizontally mount the peg board on the wall, and ensure the lateral horizontal and longitudinal vertical.
- Pull the peg board by hand after the installation, to confirm whether it is solid.
Wall-through Hole
- Make a hole with an electric hammer or a water drill at the predetermined position on the wall for piping, which shall slant outwardly by 5°-10°.
- To protect the piping and the cables from being damaged running through the wall, and from the rodents that may inhabit in the hollow wall, a pipe protecting ring shall be installed and sealed with putty.
Note: Usually, the wall hole is Cl>60mm~Cl>80mm. Avoid pre-buried power wire and hard wall when making the hole.
installation for indoor unit
Route of Pipeline
- Depending on the position of the unit, the piping may be routed sideway from the left or the right ( Fig 1 ), or vertically from the back( Fig 2 )(depending on the pipe length of the indoor unit). In the case of sideway routing, cut off the outlet cutting stock of the opposite side.
Install the connection pipe
- Remove the mountings and pull the indoor unit pipe out of the housing.
- Connect the connecting pipe to the indoor unit:
Aim at the pipe center, tighten the Taper nut with fingers, and then tighten the Taper nut with a torque wrench, and the direction is shown in diagram on the right.
IMPORTANT: If the unit with the quick connectors, please refer to the
booklet of “Install the connection pipe(the unit with the quick connectors)”.
Wrap the Piping
-
Use the insulation sleeve to wrap the joint part the indoor unit and the connection pipe, and then use insulating material to pack and seal insulation pipe, to prevent generation of condensate water on the joint part.
-
Connect the water outlet with drain pipes, and make the connection pipe, cables, and the drain hose straight.
-
Use plastic cable ties to wrap the connecting pipes, cables and drain hose. Run the pipe sloping downward.
Fixing the Indoor Unit
- Hang the indoor unit on the peg board, and move the unit from left to right to ensure that the hook is properly positioned in the peg board.
- Push toward the lower left side and the upper right side of the unit toward the peg board, until the hook is embedded in the slot and makes a “click” sound.
Interconnection cord installation
Connect interconnection cord of indoor unit
-
Open the panel, remove the screw on the wiring cover and then take down the cover.
-
Make the interconnection cord go through the cable-cross hole at the back of indoor unit and then pull it out from the front side.
(Some models do not have a signal cable.) -
Remove the wire clip; connect the interconnection cord to the wiring terminal according to the wiring diagram; tighten the screw and then fix the interconnection cord with wire clip. NOTE:This manual usually includes the wiring mode for the different kind of air conditioner. We cannot exclude the possibility that some special type of
wiring diagrams are not included.
The diagram are for reference only. If the entity is difference with this wiring diagram, please refer to the detailed wiring diagram adhered on the unit which you purchased. -
Put wiring cover back and then tighten the screw.
-
Close the panel.
After installation check
- The screws whether have been fixed effectively, and there is no risk of loosening.
- Connector of display board whether put in the right place and do not touch the terminal board.
- Control box cover whether cover tightly.
Dimension drawing of outdoor unit installation[
](https://manuals.plus/wp-content/uploads/2022/08 /ALPICAIR-Eco-X-Series-Split-Type-Wall-Mounted-Air-Conditioner-fig-38.png)
Install the connection pipe
Note: This table is for reference only. liquid side pipe
IMPORTANT: If the unit with the quick connectors, please refer to the booklet
of “Install
the connection pipe the unit with the quick connectors”. ****
Wiring Connection
- Loosen the screws and remove E-parts cover from the unit.
- Connect the cables respectively to the corresponding terminals of the terminal board of the outdoor unit (see the wiring diagram), and if there are signals connected to the plug, just conduct butt joint.
- Ground wire: Remove the grounding screw out of the electric bracket, cover the grounding wire end onto the grounding screw and screw it into the grounding hole.
- Fix the cable reliably with fasteners (Pressing board).
- Put the E-parts cover back in its original place and fasten it with screws.
Wiring diagram [
](https://manuals.plus/wp-content/uploads/2022/08/ALPICAIR-Eco-X -Series-Split-Type-Wall-Mounted-Air-Conditioner-fig-42.png)
NOTE:
- This manual usually includes the wiring mode for the different kind of air conditioner. We cannot exclude the possibility that some special type of wiring diagrams are not included
- The diagram are for reference only. If the entity is difference with this wiring diagram, please refer to the detailed wiring diagram adhered on the unit which you purchased.
Expelling the air
- Outdoor unit refrigerant discharging method After the pipe side connection is complete, proceed as follows.
Vacuum Pumping Method (R410A refrigerant evacuation must use the vacuum pumping method)
Before working on the air conditioner, remove the cover of the stop valve(gas and liquid valves)and be sure to retighten it afterward.(to prevent the potential air leakage)
-
To prevent air leakage and spilling tighten all connecting nut of all flare tubes.
-
Connect the stop valve, charge hose, manifold valve, and vacuum pump.
-
Fully open the handle Lo of the manifold valve and apply vacuum for at least 15 minutes and check that the compound vacuum gauge reads
– 0.1 MPa(-76cmHg). -
After applying vacuum, fully open the stop valve with a hex wrench.
-
Check that both indoor and outdoor connections are free of air leakage.
IMPORTANT: The unit with the quick connectors does not require vacuum pumping.
Outdoor condensation drainage(Heat pump type only)
When the unit is heating, the condensing water and defrosting water can be out
reliably through the drain house. Installation:
Install the outdoor drain elbow in
waste water formed in the outdoor unit can be drained out to a proper plate.
Check after installation and test operation
Check after installation
Electrical Safety Check
- If the supply voltage is as required.
- If there is any faulty or miss connection in each of the power, signal and grounding wires.
- If the grounding wire of the air conditioner is securely grounded.
Installation Safety Check
- If the installation is secure.
- If the water drain is smooth.
- If the wiring and piping are correctly installed.
- Check that no foreign matter or tools are left inside the unit.
Leak test of the refrigerant
Depending on the installation method, the following methods may be used to check for suspect leak, on areas such as the four connections of the outdoor unit and the cores of the cut-off valves and t-valves:
- Bubble method: Apply of spray a uniform layer of soap water over the suspected leak spot and observe carefully for bubble.
- lnstrument method: Checking for leak by pointing the probe of the leak detector according to the instruction to the suspect points of leak.
Test Operation
Test Operation preparation:
- Verify that all piping and connection cables are well connected.
- Confirm that the values at the gas side the liquid-side are fully open.
- Connect the power cable to an independent power socket.
- Install batteries in remote control.
Test Operation method:
- Turn on the power and push the ON/OFF switch button of the remote controller to start the air conditioner.
- Select COOL, HEAT (not available on cool-only models), SWING and other operation modes with the remote controller and see if the operation is ok.
Specific caution
- Open front panel of the indoor.
- The connector(as Fig) can not touch the terminal board, and is positioned as shown in Fig.