ALPICAIR AM-35CNR1A Portable Air Conditioners Owner’s Manual
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air
conditioning unit. Make sure to save this manual for future reference.
Safety Precautions
Read Safety Precautions Before Operation and Installation
To prevent death or injury to the user or other people and property damage,
the following instructions must be followed. Incorrect operation due to
ignoring of instructions may cause death, harm or damage.
WARNING
This symbol indicates the possibility of personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of property damage or serious
consequences.
WARNING
-
Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
-
Use only the included accessories and parts, and specified tools for the installation. Using non- standard parts can cause water leakage, electrical shock, fire, and injury or property damage.
-
Make sure that the outlet you are using is grounded and has the appropriate voltage.
-
The power cord is equipped with a three-prong grounding plug to protect against shock.
-
Voltage information can be found on the nameplate of the unit.
-
Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse or circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on unit), have a qualified electrician install the proper receptacle.
-
Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
-
The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
-
Do not modify the length of the power cord or use an extension cord to power the unit.
-
Do not share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
-
Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
-
Do not install the unit in a location that may be exposed to combustible gas, as this could cause fire.
-
The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects, as these could cause tipping.
-
Do not operate a unit that it has been dropped or damaged.
-
The appliance with electric heater shall have at least I meter space to the combustible materials.
-
Do not touch the unit with wet or damp hands or when barefoot
If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance. -
In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
-
Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if it occurs.
-
All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
-
The unit’s circuit board(PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board, such as. T 3.1 5A/250V, etc.
-
When the water drainage function is not in use, keep the upper and the lower drain plug firmly to the unit to get rid of choking. When the drain plug is not in use, keep it carefully to prevent children from choking.
CAUTION
- This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries)
- This appliance is not intended for use by persons (including childern) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- Children must be supervised around the unit at all times (be applicable for other countries except the European Countries )
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
- Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- Do not operate unit with a damaged cord, plug, power fuse or circuit breaker. Discard unit or return to an authorized service facility for examination and/or repair.
- To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
- The appliance shall be installed in accordance with national wiring regulations.
- Contact the authorised service technician for repair or maintenance of this unit.
- Contact the authorised installer for installation of this unit.
- Do not cover or obstruct the inlet or outlet grilles.
- Do not use this product for functions other than those described in this instruction manual.
- Before cleaning, turn off the power and unplug the unit.
- Disconnect the power if strange sounds, smell, or smoke comes from it.
- Do not press the buttons on the control panel with anything other than your fingers.
- Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
- Do not operate or stop the unit by inserting or pulling out the power cord plug
- Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol, etc.
- Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
- Always contact a qualified person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
- Hold the plug by the head of the power plug when taking it out.
- Turn off the product when not in use.
Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)
- Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the C02 equivalent in tonnes of the fluorinated greenhouse gas(on some models), please refer to the relevant label on the unit itself.
- Installation, service, maintenance and repair of this unit must be performed by a certified technician.
- Product uninstallation and recycling must be performed by a certified technician.
Sociable Remark
When using this appliance in the European countries, the following information
must be followed:
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities:
- The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
- When buying a new product, the retailer will take back the old product at least free of charge.
- The manufacture will take back the old appliance for disposal at least free of charge to the user.
- As old products contain valuable resources, they can be sold to scrap metal dealers. Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
WARNING for Using R32/R290 Refrigerant
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that the refrigerants may not contain an odour.
- Appliance should be installed, operated and stored in a room with a floor area according to the amount of refrigerant to be charged. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself. When there are differences between the lable and the manual on the Min. room area description, the description on label shall prevail
For R32 frigerant models:
Appliance shall be installed, operated and stored in a room with a floor area
larger than 4 m
Appliance shall not be installed in an unvertilated space, if that space is
smaller than 4 m
-
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction. -
The appliance shall be stored so as to prevent mechanical damage from occurring.
-
A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
-
Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
• Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled personnel shall be carried out under the supervision
of the person competent in the use of flammable refrigerants. -
Please follow the instruction carefully to handle, install, clear, service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32 or R290) shall be recovered properly, shall not discharge to air directly.
-
No any open fire or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used. Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
-
Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.For speci-c information on the type of gas and the amount, please to the relevant label on the unit itself.
-
The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
Caution: Risk of fire/
flammable materials
(Required for R32/R290 units only)
Explanation of symbols displayed on the unit(For the unit adopts R32/R290 Refrigerant only):
-
Transport of equipment containing flammable refrigerants
See transport regulations -
Marking of equipment using signs
See local regulations -
Disposal of equipment using flammable refrigerants
See national regulations. -
Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions. -
Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the equipment
inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of
equipment permitted to be stored together will be determined by local regulations. -
Information on servicing
1) Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimised. For
repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
2) Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the
risk of a flammable gas or vapour being present while the work is being
performed.
3) General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out. Work in confined spaces shall be
avoided. The area around the workspace shall be sectioned off. Ensure that the
conditions within the area have been made safe by control of flammable
material.
4) Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially flammable
atmospheres. Ensure that the leak detection equipment being used is suitable
for use with flammable refrigerants, i.e. non-sparking, adequately sealed or
intrinsically safe.
5) Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate fire extinguishing equipment shall be available
to hand. Have a dry powder or C02 fire extinguisher adjacent to the charging
area.
6) No ignition sources
No person carrying out work in relation to a refrigeration system which
involves exposing any pipe work that contains or has contained flammable
refrigerant shall use any sources of ignition in such a manner that it may
lead to the risk of fire or explosion. All possible ignition sources,
including cigarette smoking, should be kept sufficiently far away from the
site of installation, repairing, removing and disposal, during which flammable
refrigerant can possibly be released to the surrounding space. Prior to work
taking place, the area around the equipment is to be surveyed to make sure
that there are no flammable hazards or ignition risks. No Smoking signs shall
be displayed.
7) Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation
shall continue during the period that the work is carried out. The ventilation
should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
8) Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed If in doubt consult the
manufacturer’s technical department for assistance The following checks shall
be applied to installations using flammable refrigerants:
The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
The ventilation machinery and outlets are operating adequately and are not
obstructed;
If an indirect refrigerating circuit is being used, the secondary circuit
shall be checked for the presence of refrigerant; Marking to the equipment
continues to be visible and legible. Markings and signs that are illegible
shall be corrected;
Refrigeration pipe or components are installed in a position where they are
unlikely to be exposed to any substance which may corrode refrigerant
containing components, unless the components are constructed of materials
which are inherently resistant to being corroded or are suitably protected
against being so corroded.
9) Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the circuit
until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate temporary
solution shall be used. This shall be reported to the owner of the equipment
so all parties are advised.
Initial safety checks shall include:
That capacitors are discharged: this shall be done in a safe manner to avoid
possibility of sparking;
That there no live electrical components and wiring are exposed while
charging, recovering or purging the system; That there is continuity of earth
bonding.
7 .Repairs to sealed components
1)During repairs to sealed components, all electrical supplies shall be
disconnected from the equipment being worked upon prior to any removal of
sealed covers, etc. If it is absolutely necessary to have an electrical supply
to equipment during servicing, then a permanently operating form of leak
detection shall be located at the most critical point to warn of a potentially
hazardous situation.
2)Particular attention shall be paid to the following to ensure that by
working on electrical components, the casing is not altered in such a way that
the level of protection is affected. This shall include damage to cables,
excessive number of connections, terminals not made to original specification,
damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is
mounted securely. Ensure that seals or sealing materials have not degraded
such that they no longer serve the purpose of preventing the ingress of
flammable atmospheres. Replacement parts shall be in accordance with the
manufacturer’s specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types
of leak detection equipment. Intrinsically safe components do not have to be
isolated prior to working on them.
8. Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit
without ensuring that this will not exceed the permissible voltage and current
permitted for the equipment in use. Intrinsically safe components are the only
types that can be worked on while live in the presence of a flammable
atmosphere. The test apparatus shall be at the correct rating. Replace
components only with parts specified by the manufacturer. Other parts may
result in the ignition of refrigerant in the atmosphere from a leak.
9.Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
10. Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the
searching for or detection of refrigerant leaks. A halide torch (or any other
detector using a naked flame) shall not be used.
11 .Leak detection methods
The following leak detection methods are deemed acceptable for systems
containing flammable refrigerants. Electronic leak detectors shall be used to
detect flammable refrigerants, but the sensitivity may not be adequate, or may
need re-calibration. (Detection equipment shall be calibrated in a
refrigerant-free area.) Ensure that the detector is not a potential source of
ignition and is suitable for the refrigerant used. Leak detection equipment
shall be set at a percentage of the LFL of the refrigerant and shall be
calibrated to the refrigerant employed and the appropriate percentage of gas
(25 % maximum) is confirmed. Leak detection fluids are suitable for use with
most refrigerants but the use of detergents containing chlorine shall be
avoided as the chlorine may react with the refrigerant and corrode the copper
pipe-work. If a leak is suspected, all naked flames shall be removed/
extinguished.
If a leakage of refrigerant is found which requires brazing, all of the
refrigerant shall be recovered from the system, or isolated (by means of shut
off valves) in a part of the system remote from the leak. Oxygen free nitrogen
(OFN) shall then be purged through the system both before and during the
brazing process.
12.Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other
purpose conventional procedures shall be used. However, it is important that
best practice is followed since flammability is a consideration. The following
procedure shall be adhered to:
Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again
with inert gas; Open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders.
The system shall be flushed with OFN to render the unit safe. This process may
need to be repeated several times. Compressed air or oxygen shall not be used
for this task. Flushing shall be achieved by breaking the vacuum in the system
with OFN and continuing to fill until the working pressure is achieved, then
venting to atmosphere, and finally pulling down to a vacuum. This process
shall be repeated until no refrigerant is within the system.
When the final OFN charge is used, the system shall be vented down to
atmospheric pressure to enable work to take place. This operation is
absolutely vital if brazing operations on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not close to any ignition
sources and there is ventilation available.
13. Charging procedures
In addition to conventional charging procedures, the following requirements
shall be followed. Ensure that contamination of different refrigerants does
not occur when using charging equipment. Hoses or lines shall be as short as
possible to minimise the amount of refrigerant contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed prior to charging the system
with refrigerant. Label the system when charging is complete (if not already).
Extreme care shall be taken not to overfill the refrigeration system. Prior to
recharging the system it shall be pressure tested with OFN. The system shall
be leak tested on completion of charging but prior to commissioning. A follow
up leak test shall be carried out prior to leaving the site.
14. Decommissioning
Before carrying out this procedure, it is essential that the technician is
completely familiar with the equipment and all its detail. It is recommended
good practice that all refrigerants are recovered safely. Prior to the task
being carried out, an oil and refrigerant sample shall be taken in case
analysis is required prior to re-use of reclaimed refrigerant. It is essential
that electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation. b) Isolate system
electrically. c) Before attempting the procedure ensure that: Mechanical
handling equipment is available, if required, for handling refrigerant
cylinders;All personal protective equipment is available and being used
correctly;
The recovery process is supervised at all times by a competent person;
Recovery equipment and cylinders conform to the appropriate standards. d) Pump
down refrigerant system, if possible. e) If a vacuum is not possible, make a
manifold so that refrigerant can be removed from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes
place. g) Start the recovery machine and operate in accordance with
manufacturer’s instructions. h) Do not overfill cylinders. (No more than 80 %
volume liquid charge).
i) Do not exceed the maximum working pressure of thecylinder, even
temporarily. j) When the cylinders have been filled correctly and the process
completed, make sure that the cylinders and the equipment are removed from
site promptly and all isolation valves on the equipment are closed off. k)
Recovered refrigerant shall not be charged into another refrigeration system
unless it has been cleaned and checked.
15. Labelling
Equipment shall be labelled stating that it has been de-commissioned and
emptied of refrigerant. The label shall be dated and signed. Ensure that there
are labels on the equipment stating the equipment contains flammable
refrigerant.
16. Recovery
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely. When transferring refrigerant into cylinders, ensure that only
appropriate refrigerant recovery cylinders are employed. Ensure that the
correct number of cylinders for holding the total system charge is available.
All cylinders to be used are designated for the recovered refrigerant and
labelled for that refrigerant (i.e. special cylinders for the recovery of
refrigerant). Cylinders shall be complete with pressure relief valve and
associated shut-off valves in good working order. Empty recovery cylinders are
evacuated and, if possible, cooled before recovery occurs. The recovery
equipment shall be in good working order with a set of instructions concerning
the equipment that is at hand and shall be suitable for the recovery of
flammable refrigerants.
In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
Installation Instructions
Preparation
NOTE:
All the illustrations in the manual are for explanation purpose only. Your
machine may be slightly different. The actual shape shall prevail. The unit
can be controlled by the unit control panel alone or with the remote
controller. This manual does not include Remote Controller Operations, see the
«Remote Controller Instruction»» packed with the unit for details.
Design Notice
In order to ensure the optimal performance of our products, the design
specifications of the unit and remote control are subject to change without
prior notice.
Ambient Temperature Range For Unit Operating
Exhaust Hose Installation
The exhaust hose and adaptor must be installed or removed in accordance with
the usage mode. For COOL, HEAT(heat pump type) or AUTO mode must be installed
exhaust hose. For FAN, DRY or HEAT (electrical heat type) mode must be removed
exhaust hose.
Choosing The Right Location
Your installation location should meet the following requirements:
- Make sure that you install your unit on an even surface to minimize noise and vibration.
- The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
- The unit should be located at least 30cm (1 2 from the nearest wall to ensure proper air conditioning. The horizontal louver blade should be at least 50cm (19.7″) away from obstacles
- DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit.
Recommend Instruction
Energy Rating Information
The energy rating and noise information for this unit is based on the standard
installation using an un-extended
exhaust duct (Diameter. 150mm, Length:l .5m) without window slider adaptor or
wall exhaust adaptor A.
The unit with 3 meters extended exhaust duct is running by using 2 exhaust
ducts(Diameter:1 50mm, Length: 1.5m + Diameter: 130mm, Length: 1.5m) . The
Energy rating and noise information for unit with 3 meters extended exhaust
duct is not assessed (For some models)
NOTE :
We recommend that operating the unit at room temperature below 350C . Since
there is a risk that the unit with 3 meters extended exhaust duct would not
work at room temperature above 350C under some extreme conditions, such as the
lower air intake be blocked for 50%.
How to Stay Cool with a New Portable Air Conditioner(For the models comply
with the requirements of Department Of Energy in US)
Because of a new federal test procedure for Portable Air Conditioners, you may
notice that the cooling capacity claims on portable air conditioner packaging
are significantly lower than that of models produced prior to 2017. This is
due to changes in the test procedure, not to the portable air conditioners
themselves.
What should I look for first when purchasing a portable air conditioner?
The right air conditioner helps you cool a room efficiently. An undersized
unit won’t cool adequately while one that’s too large will not remove enough
humidity, leaving the air feeling damp. To find the proper air conditioner,
determine the square footage of the room you want to cool by multiplying the
room length by its width. You also need to know the air conditioner’s BTU
(British Thermal Unit) rating, which indicates the amount of heat it can
remove from a room. A higher number means more cooling power for a larger
room. (Be sure you are comparing only newer models to each other- older models
may appear to have a higher capacity, but are actually the same). Be sure to
“size up” if your portable air conditioner will be placed in a very sunny
room, in a kitchen, or in a room with high ceilings. After you’ve found the
right cooling capacity or your room, you can look at other features.
Why is the cooling capacity lower on newer models than on older units?
Federal regulations require manufacturers to calculate cooling capacity based
on a specific test procedure, which was changed just this year. Models
manufactured before 2017 were tested under a different procedure and cooling
capacity is measured differently than in prior years models. So, while the
BTUs may be lower, the actual cooling capacity of the air conditioners has not
changed
What is SACC ?
SACC is the representative value of Seasonally Adjusted Cooling Capacity, in
Btu/h, as determined in accordance with the DOE test procedure at title 10
Code of Federal Regulations (CFR) 430, subpart B, appendix CC and applicable
sampling plans.
Tools Needed
- Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors;
- Saw (On some models, to shorten window adaptor for narrow windows)
Accessories
NOTE: Items with ( * ) are on some models. Slight variations in design may
occur.
North America
Window Installation Kit
Type window installation:
Step One: Preparing the Exhaust Hose assembly
Press the exhaust hose(or extended exhaust hose) into the window slider adaptor(or wall exhaust adaptor) and unit adaptor, clamp automatically by elastic buckles of the adaptors.
Step Two: Install the Exhaust hose assembly to the unit
Insert unit adaptor of the Exhaust hose assembly into the lower groove of the
air outlet of the unit while the hook of the adaptor is aligned with the hole
seat of the air outlet and slide down the Exhaust hose assembly along the
arrow direction for installation.
Step Three: Preparing the Adjustable Window Slider
- Choose the window sliders according the size of your window. Sometimes, it needs to be cut short to meet the window size, please take extra care to cut it properly.
- Use bolts to fasten the window sliders once they are adjusted to the Proper length
Installation
NOTE: Once the Exhaust Hose assembly and Adjustable Window Slider are
prepared, choose from one of
the following two installation methods.
Type I: Hung Window or Sliding Window Installation(For some models)
Type 2: Wall Installation(For some models)
- Cut a 125mm (4.9inch) hole into the wall for the Wall Exhaust Adaptor B
- Secure the Wall Exhaust Adaptor B to the wall using the four Anchors and Screws provided in the kit.
- Connect the Exhaust Hose Assembly(with Wall Exhaust Adaptor A) to the Wall Exhaust Adaptor B.
NOTE: To ensure proper function, DO NOT overextend or bend the hose. Make
sure that there is no obstacle around the air outlet of the exhaust hose (in
the range of 500mm) in order to the exhaust system works
properly. All the illustrations in this manual are for explanation purpose
only. Your air conditioner may be slightly different. The actual shape shall
prevail.
Operating Instructions
Control Panel Features
NOTE: The following control panels are for explanation purpose only. The
control panel of the unit you
purchased may be slightly different according to the models. Your machine may
not contain some indicators or
buttons. The actual shape shall prevail.
Operation Instructions
Other Features
FOLLOW ME/TEMP SENSING feature(On some models)
NOTE: This feature can be activated from the remote control ONLY. The remote
control serves as a remote thermostat allowing for the precise temperature
control at its location.
To activate the Follow Me/Temp Sensing feature, point the remote control
towards the unit and press the Follow Me/Temp Sensing button. The remote
control will send this signal to the air conditioner until press the Follow
Me/Temp Sensing button again. If the unit does not receive the Follow Me/Temp
Sensing signal
during any 7 minutes interval, the unit will exit the Follow Me/Temp Sensing
mode.
NOTE: This feature is unavailabe under FAN or DRY mode.
AUTO-RESTART
If the unit breaks off unexpectedly due to the power cut, it will restart with
the previous function setting automatically when the power resumes.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the air flow direction
automatically
- When the Power is ON, the louver opens fully. Press the SWING button on the panel or remote controller to initiate the Auto swing feature. The louver willl swing up and down automatically.
- Please do not adjust the louver manually.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted operation in the first 3
minutes. This is to protect the unit. Operation will automatically start after
3 minutes.
POWER MANAGEMENT feature(On some models)
Under cooling operation, when the ambient temperature is lower than the
setting temperature for a period of time, the unit will be automatically
operate power management feature. The compressor and fan motor stop. When the
ambient temperature is higher than the setting temperature, the unit will be
automatically quit the power management feature. The compressor and (or) fan
motor run.
Water drainage
- During dehumidifying modes, remove the upper drain plug from the back of the unit, install the drain connector(5/8″ universal female mender) with 3/4 ” hose(locally purchased). For the models without drain connector, just attach the drain hose to the hole. Place the open end of the hose directly over the drain area in your basement floor
• During heating pump mode, remove the lower drain plug from the back of the unit, install the drain connector (5/8″ universal female mender) with 3/4 hose(locally purchased). For the models without drain connector, just attach the drain hose to the hole. Place the open end of the Hose adaptor directly over the drain area in your basement floor.
NOTE: Make sure the hose is secure so there are no leaks. Direct the hose toward the drain, making sure
Maintenance
Safety Precautions
- Always unplug the unit before cleaning or servicing.
- DO NOT use flammable liquids or chemicals to clean the unit.
- DO NOT wash the unit under running water. Doing so causes electrical danger.
- DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
Air Filter Cleaning
Removal
This unit has upper and lower filters. Take the upper filter out along the the
arrow direction. Remove the lower filter by loosening the screw(if any),
taking out the filter as shown.
Cleaning
- Wash the air filter by immersing it gently in warm water( about 40 C/1Ö4 F ) with a neutral detergent. Rinse the filter and dry it in a shady place.
Mounting
Install the upper air filter after cleaning , and install the lower filter by
using the screw (if any).
Maintenance Tips
Be sure to clean the air filter every 2 weeks for optimal performance.
The water collection tray should be drained immediately after PI error occurs,
and before storage to prevent mold
In households with animals, you will have to periodically wipe down the grill
to prevent blocked airflow due to animal hair.
CAUTION
DO NOT operate the unit without filter because dirt and lint will clog it and
reduce performance.
Unit Cleaning
Clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit
with a dry, lint-free cloth.
Store the unit when not in use
- Drain the unit’s water collection tray according to the instructions in the following section. Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold
- Turn off the appliance and unplug it.
- Clean the air filter according to the instructions in the previous section. Reinstall the clean, dry filter before storing.
Remove the batteries from the remote control.
Note: Be sure to store the unit in a cool, dark place. Exposure to direct sunshine or extreme heat can shorten the lifespan of the unit.
Note: The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dam- pened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. Never use harsh cleansers, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the unit.
Troubleshooting Tips
Impedance Information
To be in compliance EN 61000-3-11, the product MPPD-14CRN1-QB6 shall be connected only to a supply of the system impedance: I Zsyslz0.346 ohms or less, the product MPPDB-12HRN1 -QB6GI shall be connected only to a supply of the system impedance: I ZsysIzO.337 ohms or less. Before connect the product to public power network, please consult your local power supply authority to ensure the power network meet above requirement.
To be in compliance EN 61000-3-11, the product MPPDB-12HRN7-QB6GI shall be connected only to a supply of the system impedance: I ZsyslzO.348 ohms or less, the product AM-35CNR1 A shall be connected only to a supply of the system impedance: I ZsyslzO.362 ohms or less. Before connect the product to public power network, please consult your local power supply authority to ensure the power network meet above requirement.
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to (31. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 131 times higher than Ikg of C02 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
Energy consumption (1,41 kWh per 60 minutes,tN.A.J kWh per 60 minutes in heating mode,based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.