Product Information

Specifications:

  • Product Model: 854D
  • Voltage: AC 220V/230V
  • Power Consumption: 400W
  • Heating Area: 130mm*130mm
  • Heater Material: Ceramic Heater
  • Temperature Sensor: K-type Thermocouple
  • Preheat Temperature Range: 040
  • Temperature Stability: High
  • Sensor Measuring Range: Not specified
  • Thermometer Accuracy: Not specified
  • Ambient Temperature: Not specified
  • Dimensions (LWH): 20327165mm
  • Weight: About 2.8 kg

Product Usage Instructions:

1. Safety Instructions

Before using the product, please read and follow the safety
instructions below:

  • CAUTION: During the installation and use of
    this product, all electrical safety regulations of the country and
    regions must be strictly observed. The power supply must be
    disconnected when disassembling the product. Do not operate with
    power on. If the product does not work properly, please contact the
    supplier or our company, and do not disassemble or change the
    product in any way. We are not responsible for any problems caused
    by unauthorized maintenance or modification.

  • WARNING: The product should be used away from
    places where there is magnetic interference. Don’t install the
    product in a place where the surface is easy to shake or be
    impacted, as it may damage the product. Don’t install the product
    in places where it may be exposed to rain or moisture. When using,
    the surrounding temperature is extremely high, pay attention to
    prevent scalding. Don’t use in flammable and explosive
    environments. Please place the product on the table covered with
    fire-proof and heat-resistant rubber mat to avoid causing fire.
    Please unplug the power cord when the product is not used for a
    long time.

2. Overview

The QUICK 854D Infrared Preheater is designed to preheat PCBs
using far-infrared heating principle and non-contact heating
method. It works in conjunction with other heating tools such as
soldering station or hot air gun to desolder and rework the
components of the PCB.

3. Product Characteristics

The product features:

  • Three-channel temperature design for fast temperature
    switching.

  • Imported dark infrared ceramic heating element for fast
    heating, high efficiency, and long life.

  • External K-type sensor interface for convenient testing of
    actual temperature of the heating products.

  • Sensor closed loop PID control, TFT LCD display for accurate
    temperature and sectional preheating temperature setting.

  • Digital temperature calibration for convenient and fast
    adjustments.

  • Data communication port for automatic linkage control.

4. Functional Descriptions

4.1 Dimensions

The dimensions of the product are illustrated below:

4.2 Part Descriptions

NO. Part Descriptions
1 Power switch
2 Preheating area
3 Display part
4 Button
5 External port for K-type sensor
6 RS485 communication port

4.3 Key Descriptions

Key Function Descriptions
1 Press in the main interface to switch between CH1, CH2 and CH3.

In the setting interface: Return/Cancel.
2| Press in the main interface to turn on/off. In the setting
interface: Advance/Save. In the main interface, long press 2S to
enter the setting interface.
+ and –| Press at the interface same time to enter temperature
calibration.
+| In the main interface, press to increase the parameter + value.
In the setting interface: Page up.
–| In the main interface, press to decrease the parameter –
value.

FAQ (Frequently Asked Questions)

Q: What is the voltage requirement for the product?

A: The voltage requirement for the product is AC 220V/230V.

Q: Can I use the product in a flammable and explosive

environment?

A: No, it is not recommended to use the product in flammable and
explosive environments.

Q: What should I do if the product does not work properly?

A: If the product does not work properly, please contact the
supplier or our company for assistance. Do not attempt to
disassemble or change the product on your own as it may void the
warranty and cause further damage.

QUICK 854D Infrared Preheater Instruction Manual
Thank you for purchasing our products. Please keep the instruction manual properly for future reference.

Contents
1. Safety Instructions……………………………………………………………………. 1 2. Overview……………………………………………………………………………………2 3. Product Characteristics…………………………………………………………….. 2 4. Product Specifications……………………………………………………………….3 5. Functional Descriptions……………………………………………………………..4
5.1. Dimensions………………………………………………………………….. 4 5.2. Part Descriptions…………………………………………………………..5 5.3. Key Descriptions………………………………………………………….. 6 5.4. Function Descriptions of the Main Interface………………….7 6. Connection……………………………………………………………………………….. 8 7. Temperature Settings……………………………………………………………….. 8 8. Menu Settings…………………………………………………………………………… 9 8.1. Channel Settings…………………………………………………………..9 8.2. Address Settings………………………………………………………… 11 8.3. Buzzer Settings………………………………………………………….. 12 8.4. Language Settings………………………………………………………13 8.5. Password Settings………………………………………………………14 8.6. Linkage Settings………………………………………………………… 15 9. Temperature Calibration…………………………………………………………. 17

1.Safety Instructions
CAUTION
During the installation and use of this product, all electrical safety regulations of the country and regions must be strictly observed.
The power supply must be disconnected when disassembling the product. Do not operate with power on.
If the product does not work properly, please contact the supplier or our company, and do not disassemble or change the product in any way. We are not responsible for any problems caused by unauthorized maintenance or modification.
WARNING
The product should be used away from places where there is magnetic interference.
Don’t install the product in a place where the surface is easy to shake or be impacted, as it may damage the product.
Don’t install the product in places where it may be exposed to rain or moisture.
When using, the surrounding temperature is extremely high, pay attention to prevent scalding.
Don’t use in flammable and explosive environments. Please place the product on the table covered with fire-proof and
heat-resistant rubber mat to avoid causing fire. Please unplug the power cord when the product is not used for a long
time.
1

2.Overview
This infrared preheater adopts the far-infrared heating principle and non- contact heating method to preheat the PCB, and works with other heating tools such as soldering station or hot air gun to desolder and rework the components of the PCB.
3.Product Characteristics
Three-channel temperature design, fast temperature switching. Imported dark infrared ceramic heating element, fast heating,
high efficiency and long life. External K-type sensor interface, convenient to test the actual
temperature of the heating products. Sensor closed loop PID control, TFT LCD display, accurate
temperature and sectional preheating temperature setting. Digital temperature calibration, convenient and fast. Data communication port, automatic linkage control.
2

4.Product Specifications

Product model Voltage
Power consumption Heating area
Heater material Temperature sensor Preheat temperature range Temperature stability Sensor measuring range Thermometer accuracy Ambient temperature Dimensions(LWH)
Weight

854D AC 220V/230V
400W 130mm130mm Ceramic heater K-type Thermocouple
50500 ±1
Room temperature 600 ±5
040 203
271*65mm
About2.8 kg

3

5.Functional Descriptions
5.1.Dimensions
Unitmm
4

5.2.Part Descriptions

NO.

Part Descriptions

1

Power switch

2

Preheating area

3

Display part

4

Button

5

External port for K-type sensor

6

RS485 communication port

5

5.3.Key Descriptions

Key

Function Descriptions

1.Press in the main interface to switch between CH1, CH2 and CH3.
2.In the setting interface: Return/Cancel.

1.Press in the main interface to turn on/off.
2.In the setting interface : Advance/Save.
3.In the main interface, long press 2S to enter the setting interface.

+ and –

Press at the interface.

same

time

to

enter

temperature

calibration

1.In the main interface, press to increase the parameter + value.
2.In the setting interface : Page up.
1.In the main interface, press to decrease the parameter – value.
2.In the setting interface : Page down.

6

5.4.Function Descriptions of the Main Interface

Symbols

Descriptions Symbols Descriptions

Display channel.
1.Red: heating state. 2.Alternately flashing red and black: the set temperature is reached. 3.Blue: cooling state.
Buzzer on.
Display the temperature of external K-type thermometer.
T1/T2 Temperature zone 1
and temperature zone 2
7

Buzzer off.

The current set temperature value.

Press

to turn

off the temperature

control.

External K-type thermometer disconnected.
Countdown

6.Connection

  1. Insert the power plug into the power socket consistent with the label value. 2) Turn on the preheater and it will start to heat up. 3) To change the set temperature, adjust the keys on the panel. 4) After a few minutes, the temperature will reach the set value and stabilizes at the set value. 5) After working, please turn off the power supply. The preheating plate will no longer be heated, and its temperature will slowly drop to room temperature.
    7.Temperature Settings

The default temporary channel at startup is CH0. Press

to switch

to CH1, and press

successively to switch to CH2 or CH3. The

temperatures of CH1-CH3 are 200 300 and temperature zone. To

change the set temperature and display the set temperature

value

, “+” or “-” key can be used to change the temperature

value. The temperature range is 50 – 500 .

Temperature rise

Short press “+” key, the temperature will rise by 1. Long press “+” key, the temperature will rise rapidly. When the required temperature is reached, release “+” key.

Temperature drop
Short press “-” key, the temperature will drop by 1. Long press “-” key, the temperature will drop rapidly. When the required temperature is reached, release “-” key.

8

8.Menu Settings
Long press to enter the setting menu.
8.1.Channel Settings

  1. Press

key to select the channel bar, and continue to press

key to select the parameter bar.

  1. Press “+” or “-” key in the channel bar to select channels; In the

parameter bar, set the temperature and press

key to save.

  1. In CH3, select the temperature zone and press

key to enter the

temperature zone setting interface to realize the function of segmented

temperature control. Two temperature ranges can be set, in which the

temperature and time can be adjusted. The range of temperature 1 is 50

– 300, the range of temperature 2 is 300 – 500, and the range of

time 1 and 2 is 000 – 600 seconds.

When temperature 1 reaches the set temperature, the countdown starts (time 1 is set according to your requirement), when the countdown ends, it will enter temperature 2. When temperature 2 reaches the set temperature, the countdown starts (time 2 is set according to your requirement), when the countdown ends, it will return to temperature 1 and remains there. If you want to continue the above functions, press

key in the main interface to turn it off and turn it on again.

  1. Press interface.

key to go back level by level until you return to the main

9

10

8.2.Address Settings

  1. Press “+” and “-” on the main menu to switch the menu to Address. 2) Press to select the parameter and the parameter turns blue, press “+” or “-” to set the address value, which ranges from 001 to 255. 3) Press to save.
    11

8.3.Buzzer Settings

  1. Press “+” and “-” on the main menu to switch the menu to Buzzer. 2) Press to select the parameter and the parameter turns blue, press “+” or “-” to turn the buzzer on or off. 3) Press to save.
    12

8.4. Language Settings

  1. Press “+” and “-” on the main menu to switch the menu to Language. 2) Press to select the parameter and the parameter turns blue, press “+” or “-” to select English and Chinese. 3) Press to save.
    13

8.5.Password Settings

  1. Press “+” and “-” on the main menu to switch the menu to Password.

  2. Press to input the old password (default 000000) and enter the new

password setting interface. Press “+” or “-” to change the value,

each time you input a value, you need to press

to confirm.

  1. After the new password input is completed, the screen will display “Successfully”. Then it will be directly back to the Channel.

  2. The new password takes effect after it is shut down and restarted or return to the main interface.

14

8.6.Linkage Settings

  1. Press “+” and “-” on the main menu to switch the menu to Linkage.

  2. Double click to select mode 1, M1 turns blue, and press to confirm. M1: There is no linkage.

again

  1. Press “-” to select mode 2, press , M2 turns blue. Press to confirm. M2: External equipment controls the preheater.

again

  1. Press “-” to select mode 3, press , the value of mode 3 turns blue, press “+” or “-” to select appropriate temperature.
    M3: Preheater controls external equipment, with optional temperature r ange of 50 ~ 350 .

  2. Press

to return to the main interface.

15

16

9.Temperature Calibration
Note:

  1. When the display temperature is consistent with the set temperature, the temperature can be calibrated. 2) Long press “+” and “-” for 2s to enter the temperature calibration interface. For example a) The product needs to be preheated to 100 , so we set the temperature to 100 .

Display temperature

Set temperature

b) When the temperature is set to 100 due to the material of the

preheating plate and environmental factors, the temperature above the

preheating plate is measured to be 95 by the thermometer. Input the

value of 95 in the temperature calibration interface, and press

to

exit.

17

Warranty Card

The warranty period of this product

Warranty Card

is calculated from the date of Purchase.

During the warranty period, if the

product breaks down during normal use,

show the original warranty card and enjoy free service in the authorized

Type:

repair company(or our company). Please keep the purchase certificate and

Model No.:

this warranty card and show it before maintenance.

Serial No.:

During the warranty period, the following repairs need to be paid:

Delivery Date:

a.Unable to offer valid warranty card or

certificate;

b.The purchase date, sales company

and other items are not completely filled in

or the warranty card is altered;

c.Damage caused by failure to follow the

use methods and precautions in the

manual;

Warranty File Card

d.Damage caused by disassembly, repair

and modification of products without

authorization of the manufacturer;

e.Replacement of vulnerable and consumable parts.

Type:

All items of the warranty card shall be completely filled in by the agent or user

Model No.:

to obtain a 12-month warranty period. Please keep this warranty card properly.

Serial No.:

It will not be re-offered after.

Delivery Date:

QUICK INTELLIGENT EQUIPMENT CO., LTD.

Address :

ADD: NO.11, FengXiang Road, Wujin High-Tech Industrial Development Zone, Jiangsu, China

Postcode:

TEL: 86-519-86225678 FAX: 86-519-86558599

Telephone:

POSTCODE: 213167 WEBSITE: www.quick-global.com

Contact Person:

QUICK INTELLIGENT EQUIPMENT CO., LTD.
ADD: NO.11, FengXiang Road, Wujin High-Tech Industrial Development Zone, Jiangsu, China
TEL: 86-519-86225678
FAX: 86-519-86558599 POSTCODE: 213167
WEBSITE: www.quick-global.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals