inELS RFSA-61B-24V Switch Unit 1 channel User Manual
- June 14, 2024
- inELS
Table of Contents
inELS RFSA-61B-24V Switch Unit 1 channel
Characteristics
- The switching unit with 1 output channel is used to control appliances, lights (easy to integrate it to control garage doors or gates).
- They can be combined with detectors, controllers, iNELS RF Control or system components.
- The BOX design lets you mount it right in an installation box, a ceiling or controlled appliance cover.
- It enables connection of the switched load up to 16A (4.000 W).
- RFSA-11B : single function design – switch on / off.
- RFSA-61B : multifunction design – button, impulse relay and time function of delayed ON or OFF with time setting of 2s-60 min.
- The switching unit may be controlled by up to 25 channels (1 channel represents 1 button on the controller).
- The programming button on the unit is also used for manual control of the output.
- Memory status can be preset in the event of a power failure.
- For components labelled as iNELS RF Control2 (RFIO2), it is possible to set the repeater function via the RFAF/USB service device.
- Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.
- Communication frequency with bidirectional protocol iNELS RF Control2 (RFIO2).
Assembly
- mounting in an installation box
- mounting into the light cover
- ceiling mounted
Connection
Radio frequency signal penetration through various construction materials.
For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures
Indication, manual control
- LED STATUS – indication of the device status.
Indicators of memory function
- On – LED blinks x 3.
- Off – The LED lights up once for a long time.
- Manual control is performed by pressing the PROG button for less than 1s.
- Programming is performed by pressing the PROG button for more than 1s.
In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed this indicates the incoming command.
Compatibility
- The device can be combined with all system components, controls and devices of iNELS RF Control and iNELS RF Control2.
- The detector can be assigned an iNELS RF Control2 (RFIO2) communication protocol.
RFSA-11B
Functions and programming with RF transmitters
Function button ON/OFF
Description of button
The output contact closes by pressing one button position, and opens by
pressing the other button position.
Programming
-
Press of programming button on actuator RFSA-11B for 1 second will activate actuator RFSA-11B into programming mode. LED is flashing in 1s interval.
-
Pressing your chosen button on the RF transmitter assigns the function “close”. The second position of the control “switch off ” is assigned automatically (for 4 button in the same half of the RF transmitter).
-
Press of programming button on actuator RFSA-11B shorter then 1 second will finish programming mode. The LED lights up according to the preset memory function.
RFSA-61B
Functions and programming with RF transmitters
Function button
Description of button
- The output contact will be closed by pressing the button and opened by releasing the button.
For the correct execution of individual commands (press = closing / releasing the button = opening), the time delay between these commands must be a min of . 1s (press – delay 1s – release).
Programming
-
Press of programming but-ton on actuator RFSA-61B for 1 second will activate actua-tor RFSA-61B into program-ming mode. LED is fl ashing in 1s interval.
-
Select and press one button on wireless switch, to this button will be assigned function Button.
-
Press of programming button on actuator RFSA-61B shorter then 1 second will finish programming mode. The LED lights up according to the preset memory function.
Function switch on
Description of switch on
- The output contact will be closed by pressing the button.
Programming
-
Press of programming button on actuator RFSA-61B for 1 second will activate actuator RFSA-61B into program-ming mode. LED is fl ashing in 1s interval.
-
Press of programming button on actuator RFSA-61B for 1 second will activate actuator RFSA-61B into programming mode. LED is flashing in 1s interval.
-
Press of programming button on actuator RFSA-61B shorter then 1 second will finish programming mode. The LED lights up according to the preset memory function.
Function switch off
Description of switch off
The output contact will be opened by pressing the button.
Programming
-
Press of programming button on actuator RFSA-61B for 1 second will activate actua-tor RFSA-61B into programming mode. LED is flashing in 1s interval.
-
Three presses of your selected button on the RF transmitter assigns the function switch off (must be a lapse of 1 s between individual presses).
-
Press of programming button on actuator RFSA-61B shorter then 1 second will finish programming mode. The LED lights up according to the preset memory function.
Function impulse relay
Description of impulse relay
The output contact will be switched to the opposite position by each press of
the button. If the contact was closed, it will be opened and vice versa.
Programming
-
Press of programming button on actuator RFSA-61B for 1 second will activate actuator RFSA-61B into programming mode. LED is fl ashing in 1s interval.
-
Four presses of your selected button on the RF transmitter assigns the function impulse relay (must be a lapse of 1 s between individual presses).
-
Press of programming button on actuator RFSA-61B shorter then 1 second will fi nish programming mode. The LED lights up according to the preset memory function.
Function delayed off
Description of delayed off
The output contact will be closed by pressing the button and opened after the
set time interval has elapsed.
Programming
-
Press of programming button on actuator RFSA-61B for 1 second will activate actuator RFSA-61B into programming mode. LED is flashing in 1s interval.
-
Assignment of the delayed off function is performed by fi ve presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
-
Press of programming button longer then 5 seconds, will activate actuator into timing mode. LED fl ashs 2x in each 1s interval. Upon releasing the button, the delayed return time starts counting.
-
After the desired time has elapsed (range of 2s…60min), the timing mode ends by pressing the button on the RF transmitter, to which the delayed return function is assigned. This stores the set time interval into the actuator memory.
-
Press of programming button on actuator RFSA-61B shorter then 1 second will fi nish programming mode. The LED lights up according to the preset memory function.
Function delayed on
Description of delayed on
The output contact will be opened by pressing the button and closed after the
set time interval has elapsed.
Programming
-
Press of programming button on actuator RFSA-61B for 1 second will activate actuator RFSA-61B into programming mode. LED is fl ashing in 1s interval.
-
Assignment of the delayed on function is performed by six presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
-
Press of programming button longer then 5 seconds, will activate actuator into timing mode. LED fl ashs 2x in each 1s interval. Upon releasing the button, the delayed return time starts counting.
-
After the desired time has elapsed (range of 2s…60min), the timing mode ends by pressing the button on the RF transmitter, to which the delayed return function is assigned. This stores the set time interval into the actuator memory.
-
Press of programming button on actuator RFSA-61B shorter then 1 second will fi nish programming mode. The LED lights up according to the preset memory function.
Programming with RF control units
The address listed on the front of the actuator is used for programming and
controlling actuators by RF control units.
Delete actuator
Deleting one position of the transmitter
- By pressing the programming button on the actuator for 5 seconds, deletion of one transmitter activates. LED fl ashs 4x in each 1s interval.
- Pressing the required button on the transmitter deletes it from the actuator’s memory.
- To confi rm deletion, the LED will confirm with a fl ash long and the component returns to the operating mode. The memory status is not indicated.
- Deletion does not affect the preset memory function.
Deleting the entire memory
- By pressing the programming button on the actuator for 8 seconds, deletion occurs of the actuator’s entire memory. LED fl ashs 4x in each 1s interval.
- The actuator goes into the programming mode, the LED fl ashes in 0.5s intervals (max. 4 min.).
- You can return to the operating mode by pressing the Prog button for less than 1s. The LED lights up according to the preset memory function and the component returns to the operating mode.
- Deletion does not aff ect the preset memory function.
Selecting the memory function
-
Press of programming button on receiver RFSA-x1B for 1 second will activate receiver RFSA-x1B into programming mode. LED is fl ashing in 1s interval.
-
Pressing the programming button on the RFSA-x1B receiver for less than 1 second will finish the programming mode, this will reverse the memory function. The LED lights up according to the current preset memory function. The set memory function is saved.
- Every other change is made in the same way.
Memory function on
- For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change.
- For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after reconnecting the power, the relay is set to the target state.
Memory function off
When the power supply is reconnected, the relay remains off.
Technical parameters
RFSA-11B/230V RFSA-11B/120V RFSA-11B/24V
Supply voltage | 230 V AC / 50-60 Hz | 120 V AC / 60Hz | 12-24 V AC/DC 50-60Hz | |
---|---|---|---|---|
Apparent input | 7 VA / cos φ = 0.1 | 7 VA / cos φ = 0.1 | – | |
Dissipated power | 0.7 W | 0.7 W | 0.7 W | |
Supply voltage tolerance | +10 %; -15 % | |||
O utput | ||||
Number of contacts | 1x switching | |||
Rated current | 16 A / AC1 | |||
Switching power | 4000 VA / AC1, 384 W / DC | |||
Peak current | 30 A / <3 s | |||
Switching voltage | 250 V AC1 / 24 V DC | |||
Min. DC switching power | 500 mW | |||
Mechanical service life | 3×107 | |||
Electrical service life (AC1) | 0.7×105 | |||
Contro l | ||||
RF, by command from transmitter | 866 MHz, 868 MHz, 916 MHz | |||
Manual control | button PROG | |||
Range in free space | up to / až 200 m | |||
O ther data | ||||
Operating temperature | -15 … + 50 °C | |||
Operating position | any | |||
Mounting | free at lead in wires | |||
Protection | IP 30 | |||
Overvoltage category | III. | |||
Contamination degree | 2 | |||
Terminals (CY wire, cross-section) | 2x 0.75 mm2 , 2x 2.5 mm2 | |||
Length of terminals | 90 mm | |||
Dimensions | 49 x 49 x 21 mm | |||
Weight | 46 g | |||
Related standards | EN 60730, EN 63044, EN 300 220, EN 301 489 |
Attention
- When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
- Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device.
It is always a part of its packing. Installation and connection can be carried
out only by a person with adequate professional qualification upon
understanding this instruction manual and functions of the device, and while
observing all valid regulations. Troublefree function of the device also
depends on transportation, storing and handling. In case you notice any sign
of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and
its parts as electronic waste after its lifetime is terminated. Before
starting installation, make sure that all wires, connected parts or terminals
are deenergized. While mounting and servicing observe safety regulations,
norms, directives and professional, and export regulations for working with
electrical devices. Do not touch parts of the device that are energized – life
threat. Due to transmissivity of RF signal, observe correct location of RF
components in a building where the installation is taking place. RF Control is
designated only for mounting in interiors. Devices are not designated for
installation into exteriors and humid spaces. The must not be installed into
metal switchboards and into plastic switchboards with metal door –
transmissivity of RF signal is then impossible. RF Control is not recommended
for pulleys etc. – radiofrequency signal can be shielded by an obstruction,
interfered, battery of the transceiver can get fl at etc. and thus disable
remote control.
ELKO EP, s.r.o.
- 769 01 Holešov, Všetuly
- Czech Republic
- e-mail: elko@elkoep.com
- Support: +420 778 427 366
- E-mail: elkoep@elkoep.sk
- www.elkoep.com
- www.elkoep.sk