POWER-LITE MS-6M-360 Infrared Motion Sensor Instruction Manual
- June 15, 2024
- POWER-LITE
Table of Contents
POWER-LITE MS-6M-360 Infrared Motion Sensor
Introduction
The MS-6M-360 infrared motion sensor is equipped with integrated circuitry that provides great detection sensitivity. It utilizes the infrared energy emitted by humans as the control-signal source.
Specifications
- Power Source: 220-240V/AC
- Power Frequency: 50/60Hz
- Ambient Light:
Product Usage Instructions
- Power Source: Connect the MS-6M-360 infrared motion sensor to a power source with a voltage rating of 220-240V/AC.
- Power Frequency: Ensure that the power frequency of the connected power source is either 50Hz or 60Hz.
- Ambient Light: The MS-6M-360 infrared motion sensor is designed to detect motion in various lighting conditions. However, it is recommended to avoid installing the sensor in direct sunlight or areas with intense artificial lighting, as it may affect its performance.
- Mounting: Choose an appropriate location for mounting the sensor, preferably at a height of around 2-3 meters. Ensure that the sensor has a clear line of sight to the area you want to monitor for motion.
- Sensitivity Adjustment: The MS-6M-360 infrared motion sensor allows you to adjust its detection sensitivity. Refer to the user manual for instructions on how to adjust the sensitivity to suit your specific requirements.
- Testing: After installation, test the sensor by walking within its detection range and ensuring that it triggers the desired response, such as activating lights or alarms.
- Maintenance: Regularly clean the sensor lens with a soft cloth to remove any dust or dirt that may affect its performance. Avoid using harsh chemicals or abrasive materials for cleaning.
For more detailed information on installation, operation, and troubleshooting, please refer to the complete user manual.
Introduction
MS-6M-360 infrared motion sensor
The sensor has great detection sensitivity via integrated circuitry. It
utilizes the infrared energy from humans as the control-signal source.
Specifications
- Power Source: 220-240V/AC
- Power Frequency: 50/60Hz
- Ambient Light: <3-2000LUX (adjustable)
- Time Delay:
- Min.10sec±3sec
- Max.15min±2min
- Rated Load:
- Max.2000W
- 1000W
- Detection Range: 360°
- Detection Distance: 6m max (<24℃)
- Working Temperature: -20~+40℃
- Working Humidity: <93%RH
- Power Consumption: approx 0.5W
- Installation Height: 2.2-4m
- Detection Moving Speed: 0.6-1.5m/s
Installation
As the detector responds to changes in temperature, avoid the following situations:
- Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
- Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
- Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
Warning. Danger of death through electric shock!
* Must be installed by professional electrician.
* Disconnect power source.
* Cover or shield any adjacent live components.
* Ensure device cannot be switched on.
* Check power supply is disconnected.
- Please turn the upper cover anti-clockwise as per the diagram on the right.
- Connect the power and the load as per the wiring diagram.
- Fix the sensor to the installation surface.
- Place the cover back onto the sensor, then switch on the power and test it.
Wiring Diagram
Sensor Information
Testing the Sensor
-
Adjust the hold time using the time control on the side of the sensor to 10 seconds.
-
Switch on the power; the sensor and its connected lamp will have no signal to start with. After Warm-up 30sec, the sensor will work. If the sensor receives the induction signal, the lamp will turn on. When there is no induction signal, the load should stop working within 10sec±3sec and the lamp would turn off.
-
Turn LUX control clockwise to the minimum (3). If the ambient light is more than 3LUX, the sensor will not be activated. If the ambient light is less than 3LUX (night time), the sensor will be activated.
Note if testing during daylight, turn the lux control clockwise to the sun setting.
If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.
Troubleshooting
- The load does not work:
- Please check if the connection of power source and load is correct.
- Please check if the load is ok.
- Please check if the settings of on the sensor correspond to ambient light.
- The sensitivity is poor:
- Please check if there is any obstruction in front of the detector that would cause the sensor not to receive a signal.
- Please check if the ambient temperature is too high.
- Please check if the induction signal source is in the detection field.
- Please check if the installation height corresponds to the height recommended in the instruction leaflet.
- The sensor won’t switch off the load automatically:
- Please check if there is continual signal in the detection field.
- Please check if the time delay is set to the maximum position
ABOUT COMPANY
- 1800 909 306
- nedlandsgroup.com.au
- sales@nedlandsgroup.com.au
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>