simx FAN0120 Extraction Fan Selection User Guide
- June 1, 2024
- Simx
Table of Contents
- FAN0120 Extraction Fan Selection
- Specifications
- Product Usage Instructions
- Regulations and Standards
- Choosing the Right Fan to Comply
- Fan Type Considerations
- Q: How do I determine the airflow rate required for different
- Q: What type of fans are suitable for shorter duct runs?
- Q: How can I ensure compliance with ventilation standards?
FAN0120 Extraction Fan Selection
Specifications
- Maximum length of flexible ducting: Sleeve
- Duct Supports: Minimum radius = diameter of ducting
- Exterior Grille Airflow: Peaks and troughs
- Preferred flexible ducting route: Interior Grille Airflow
- Sealant Cavity Restrictions
Product Usage Instructions
Regulations and Standards
New Zealand Building Code and Healthy Homes require mandatory
extraction ventilation in certain categories.
Choosing the Right Fan to Comply
Fans must be selected based on the complete installed system
performance for a designated room.
Fan Type Considerations
Consider location, sound levels, and aesthetic appeal when
choosing a fan. Different fans suit different applications.
Short Run Systems
For through wall or window mounted fans, select a fan with low
pressure for short run systems.
Ducted Systems
For longer ducted systems, consider centrifugal or mixed flow
fans for necessary pressure and resilience to overcome
resistance.
Installed System Performance
The performance can vary based on location, duct length, bends,
and accessories like backdraught shutters. Follow best practice
guidelines for installation.
FAQ
Q: How do I determine the airflow rate required for different
rooms?
A: Refer to the table provided in the manual for recommended
airflow rates for rooms like toilets, bathrooms, laundries, and
kitchens.
Q: What type of fans are suitable for shorter duct runs?
A: Axial inline fans are suitable for shorter duct runs, such as
through wall or window mounted fans.
Q: How can I ensure compliance with ventilation standards?
A: Select fans based on complete installed system performance
and follow best practice guidelines for duct installation and
accessory use.
extraction fan selection guide
www.simx.co.nz
1
Regulations and Standards
New Zealand Building Code and Healthy Homes
The following two category requirements have been established for mandatory
extraction ventilation in New Zealand.
The New Zealand Building Code for New Building Consents The building
regulatory system sets out a framework to promote good quality decisions being
made during the Building Consent process. The legislation and regulations work
together, as the building regulatory system. The functional clauses of the NZ
Building Code are grouped and described by a letter and number. Clause G of
the NZ Building Code covers services, with G4 setting out the performance
requirements for ventilation. The Building Code is enshrined in law. The New
Zealand Building Code, G4, has been changed. This is supported by Acceptable
Solution G4/AS1 Fourth Edition that specifies mechanical ventilation in
accommodation units that contain cooktops, showers and baths.
Residential Tenancy Regulations to the Healthy Homes Standards Residential
Tenancy Regulations for rental properties only is changing to the Healthy
Homes Standards, sub part 4 – Ventilation Standards.
Complying with the Acceptable Solution G4/AS1 To comply, the mandatory
mechanical extract system must deliver minimum airflow rates for the complete
installed ventilation system. This means that airflow rates must deliver the
airflow after resistance of the ducting, internal and external grilles, as
well as all other accessories, such as backdraught shutters, are included. Fan
selection is important as some types are far better at overcoming ducting
system pressure drops. Additionally, the quality of the ducting system
installation can be all important. Rigid duct systems are best as they are the
most efficient. Good installation practice is vital for flexible duct systems.
Sleeve
Maximum length of flexible ducting
Duct Supports
Minimum radius = diameter of ducting
Exterior Grille Airflow
Peaks and troughs
Preferred flexible ducting route
Interior Grille
Airflow
Sealant
Cavity
Restrictions
Choosing the Right Fan to Comply
Fans cannot be selected on the basis of free-air performance only. Fans must now be selected on the basis of the complete installed system performance for a designated room as per the table below.
Room
Toilet1) Bathroom/shower Laundry2) Kitchen
Airflow Rate (min.)
Intermittent
Continuous
25 l/s
10 l/s
25 l/s
10 l/s
40 l/s
–
50 l/s
12 l/s
- Toilets only require ventilation if they have no openable windows 2) Simx
recommends 40 l/s for laundries with unvented non-condensing tumble dryers as
covered in AS 1668: Part 2 2012
With earlier unregulated extract fan practices in New Zealand, the market trended to basic, low pressure axial fan products, as installed system performance was not defined for independent inspection testing and compliance signed off by local authorities. This approach has changed under the latest mandatory regulations.
Fan Type Considerations
Determining the best fan requires consideration of location, sound levels and
aesthetic appeal. Different fans suit different applications. The longer the
duct run, the greater the pressure that is required to over come the
resistance created by the duct. Low pressure is required for short run
systems, such as through wall or window mounted fans, but far greater pressure
is required for longer ducted systems and where the fan and ducting, with more
bends, is installed in the roof cavity.
Short Run Systems As through wall and window mounted axial fans only have to extract air over a short distance, the installed system performance rates are only slightly lower than that of fan’s free-air performance rate. Fan selection to ensure compliance for any room requirement is, therefore, a straightforward procedure. See page 6 for further information.
Ducted Systems The best solutions for ducted systems are centrifugal and mixed
flow fans. These types of extraction fans are designed to develop the
necessary pressure and resilience to overcome duct and grille system pressure-
drop resistance. Axial inline fans are suitable for shorter duct runs, but
will not be very forgiving when it comes to installation so care must be taken
to ensure the best practice guidelines are followed.
Installed performance of a fan can, however, vary greatly dependent on the
location, length of duct, number of bends and fittings such as backdraught
shutters, cowls and grilles. For complete installed system performances to
meet the standards, the following guidelines may be used as application limits
dependent on best practice duct installation being employed along with the use
of airflow efficient accessories such as grilles and backdraught shutters.
2
www.simx.co.nz
Fan Selection Guidelines
Ceiling Extraction Fans
The new Manrose CONTOUR range of centrifugal fans offers model options that
easily exceed the New Zealand Building Code G4/AS1 requirements for that
specific room installation. To make it even easier for correct product
selection, Manrose Contour fans are identified by their intended application
purpose.
Selection Reference Guide Toilet Manrose Contour Toilet fan – FAN7030 Bathroom
Manrose Contour Bathroom fan – FAN7031 Laundry Manrose Contour Kitchen and
Laundry fan – FAN7032 Kitchen Manrose Contour Kitchen and Laundry fan –
FAN7032
Further, the Manrose CONTOUR fan range also includes the CONTOUR High Steam
Area Fans (FAN7033 & FAN7034) for the more demanding applications and/or
complete performance peace-of-mind. See page 9 for details.
Toilet
25 l/s
Metres of Ducting
1
2
3
4
5
6
7
8
9
10
1
2
No. of Bends
3
4
5
Bathroom
25 l/s
Toilets only require ventilation if they have no openable windows Metres of Ducting
1
2
3
4
5
6
7
8
9
10
1
2
No. of Bends
3
4
5
Laundry
40 l/s
Metres of Ducting
1
2
3
4
5
6
7
8
9
10
1
2
No. of Bends
3
4
5
Kitchen
50 l/s
Simx recommends 40 l/s for laundries with unvented non-condensing tumble dryers Metres of Ducting
1
2
3
4
5
6
7
8
9
10
1
2
No. of Bends
3
4
5
DESIGNED FOR
Fan Selection Contour Toilet – FAN7030 Contour Bathroom – FAN7031 Contour
Kitchen & Laundry – FAN7032
www.simx.co.nz
3
Fan Selection Guidelines
Inline Extraction Fans
The following chart provides easy fan selection guidelines, if good ducting
system selection and installation best practices have been employed. This is
to ensure compliance with the building code. An upgrade to the next available
model is always recommended for higher airflow rates and more complex
installations. These are guideline recommendations to assist with fan
selection for NZBC G4/AS1 compliance.
Selection Reference Guide
Toilet
Manrose Hyper150 EC axial fan for simple runs
Manrose Mixflo 150 mixed flow fan for longer runs
Bathroom Manrose Hyper150 EC axial fan for simple runs
Manrose Mixflo 150 mixed flow fan for longer runs
Laundry
Manrose Mixflo 150 axial fan
Kitchen
Manrose Mixflo 150 or Manrose Blue Jet mixed flow fans for best efficiency/airflow or on long ducts
Toilet
25 l/s
Metres of Ducting
1
2
3
4
5
6
7
8
9
10
1
2
No. of Bends
3
4
5
Bathroom
25 l/s
Toilets only require ventilation if they have no openable windows Metres of Ducting
1
2
3
4
5
6
7
8
9
10
1
2
No. of Bends
3
4
5
Laundry
40 l/s
Metres of Ducting
1
2
3
4
5
6
7
8
9
10
1
2
No. of Bends
3
4
5
Kitchen
50 l/s
Simx recommends 40 l/s for laundries with unvented non-condensing tumble dryers Metres of Ducting
1
2
3
4
5
6
7
8
9
10
1
2
No. of Bends
3
4
5
Fan Selection Hyper150 EC Mixflo 150 Blue Jet
4
www.simx.co.nz
Fan Selection Guidelines
Through Wall and Window Fans
The through wall and window fans listed in the following sections provide an
easy fan selection guideline for Manrose through wall or window fans designed
for the New Zealand Building Code G4 Acceptable Solution when best practice
duct system selection and installation is used. An upgrade higher pressure and
free-air performance is always recommended for better results.
Fan Models with Simple Selection Reference Guidelines – to be used in conjunction with the following pages
Toilet
125mm fan
150mm fan
Bathroom 125mm fan
150mm fan
Laundry
150mm fan
Kitchen
150mm fan
Healthy Home Compliance – for Residential Tenancies rental properties only
Application
Toilet
150mm 125mm
Designer FAN7183 FAN7180
Wall / Ceiling Fans Pro-Series FAN0594
FAN0589
Classic FAN0120 FAN0072
Through Wall / Ceiling Fan Kits
Designer
Pro-Series
Classic
FAN7190
FAN0621
FAN0135
FAN7187
FAN0614
FAN0080
Bathroom
150mm 125mm
FAN7183 FAN7180
FAN0594 FAN0589
FAN0120 FAN0072
FAN7190 FAN7187
FAN0621 FAN0614
FAN0135 FAN0080
Laundry 150mm
FAN7183
FAN0594
FAN0120
FAN7190
FAN0621
FAN0135
Kitchen
150mm
FAN7183
FAN0594
FAN0120
FAN7190
FAN0621
FAN0135
Window Fans Classic FAN0107 FAN0107 FAN0107 FAN0107
Continuous Ventilation
As an alternative to the traditional intermittent fans, the products shown
below can be set as continuous running fans which provide a low level of
trickle ventilation which runs constantly. These fans then have a boost
facility via manual or automatic operation. These fans provide the most energy
efficient and comfortable form of ventilation with low noise and excellent
indoor air quality.
Genius
Blue Jet
IntelliVent
MultiVent FAN7200
Filtered Passive Ventilation
The Puro Filtered Passive Vent Kit DCT4565 is recommended for use in
conjunction with Manrose and Vent-Axia extract fans to deliver improved indoor
air quality. This is especially recommended with the continuously operating
fans above.
www.simx.co.nz
5
Choose the Right Fan
Extraction fans should be placed as close as possible to the steam source
(e.g. over or near the shower). Inline fans are the most appropriate solution
as the extraction grille can be placed directly above the steam source. Use
following steps 1-6 as your guide to selecting the right fan for your
application.
1. Calculate the Room Size
· Calculate the room volume in cubic metres (L x W x H) e.g. 2.8m x 2.6m x 2.4m = 17.47m3.
· Multiply the room volume by the following guidelines for air changes per hour (ACH) for that room. Always use the higher limit.
H
Toilets
6-10 ACH
Bathrooms, showers, ensuites
11-15 ACH
Kitchens, laundries
15-20 ACH
L
W
· The result is the minimum airflow performance required in cubic metres per hour that can be assessed against the fans Free Air Fan Performance,
listed on the following pages, after a large downgrading allowance is made for the considerable slowing effect of a complete installed system. See page 3 for a description of duct system losses that will also occur from fascias, grilles, cowls and backdraft shutters. Manrose technical support can be consulted for their recommendations.
2. Consider the Location in the Room
The right placement of an extraction fan will ensure optimum airflow through the bathroom. To ensure the fan works to its maximum efficiency, the extracted air needs to be replenished, or “made up”, with an equal amount of dry air drawn in from an adjacent room or hallway. This make-up air replenishment may be assisted with the installation of a door grille (FAN0159).
Window Open
Window Closed
Window Closed
Poor Circulation
Medium Circulation
3. Wet Area Zones & Recommended Fan Types
Wet area zones are determined by their proximity to the bath or shower. Use the wet area zone plan and table to identify what type of fan is required.
Zone Description
Recommended Fan Type
1
Area immediately above the bath or shower tray up to the higher of either 2.25m or the height of the fixed plumbing connection
Safety extra low voltage, inline fans only, or contour without light
2 Area within 0.6m around the edge of the bath or shower tray 3 Any area outside Wet Area Zones 1 & 2
Any fan Any fan
Best Circulation
1
1
2
2
3
3
2 3
4. Select a Fan Type
From the list below select a fan type, then see the following sections to
identify the model you require. Ensure the model you select has a performance
(m3/h) greater than the performance calculated in step 1.
Fan Type
Application
Key
Inline Extraction Fans
Wet area zone 1
Wall/Ceiling Fans
Wall and ceiling
Heat-Fan-Light Systems
Ceiling, multi-function
Inline Extraction Fan Kits
Wet area zone 1, integrated light
Through Wall Fan Kits
Wall
Through Roof Fan Kits
Roof
Safety Extra Low Voltage (SELV)
Wet area zone 1
Window Fans
Window
5. Saving Energy
The best way of calculating the most efficient fan for your needs, is to
compare the specific fan powers of each one selected. The fan with the lower
watts per l/s, will use less energy. If a fan has similar specific fan power
to another, but much higher pressure for ducted installations, it will still
be the more efficient option.
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
25
60
101
364
0.25
20
35
36
130
0.56
Sound dB(A)
40 41
6. Fan Switching Options
Option
Description
Standard Timer
Remote wall switch Remote switch with delayed OFF adjustable from 1-20 minutes
Pull Cord PIR Control
Integral pull cord switch on fan Motion sensor incorporated in fan
Option Auto Sense Variable Speed Controller Humidity Automation
Description Condition sensor incorporated in fan Incorporated speed drive in fan Humidity sensing and control incorporated in fan
6
www.simx.co.nz
DESIGNER SERIES
CONTOUR
FAN SYSTEMS
Setting the Standards in Ventilation Solutions
BAT
DESIGNED FOR HRHOEOASLTMTAHNSYD&HAORKMD IETSC
H ENS
Manrose Contour Fan Systems
the new standard in powerful, stylish, easy to install, configurable extract systems
www.simx.co.nz
7
Ceiling Extraction Fans – Centrifugal
Manrose CONTOUR fans deliver simple compliance with current New Zealand
Building Code G4/AS1 mandatory mechanical extract ventilation system
requirements. As well as providing application room specific performance,
Contour Toilet, Bathroom and Kitchen & Laundry fans have a comprehensive range
of stylish, interchangeable fascia to choose from.
CONTOUR Toilet Fan
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure (Pa)
Free Air Fan Performance
(l/s) (m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Product Code
100 Centrifugal
30
93
49
175
0.61
38
Range Selection
Standard
FAN7030
CONTOUR Bathroom Fan
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure (Pa)
Free Air Fan Performance
(l/s) (m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Product Code
150 Centrifugal
45
147
77
276
0.58
40
Range Selection
Standard
FAN7031
CONTOUR Kitchen and Laundry Fan
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure (Pa)
Free Air Fan Performance
(l/s) (m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Product Code
150 Centrifugal
50
210
105
378
0.48
42
Range Selection
Standard
FAN7032
CONTOUR High Steam Area Fan
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure (Pa)
Free Air Fan Performance
(l/s) (m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Product Code
Round White
Standard
FAN7033
150 Centrifugal
106
220
153
550
0.69
42
Square White
Standard
FAN7034
Fascia Selections Fan
White
Round
Black
LED White
LED Black
White
Square
Black
LED White
LED Black
Toilet Bathroom Kitchen and Laundry
DCT4502 DCT4510
DCT4503 DCT4511
DCT4506 DCT4714
DCT4507 DCT4515
DCT4504 DCT4712
DCT4505 DCT4513
DCT4508 DCT4516
DCT4509 DCT4517
8
www.simx.co.nz
Inline Extraction Fans – Mixed Flow
The Blue Jet fan incorporates powerful jet streaming technology and is driven
by the energy efficient, brushless EC motor to deliver best-in-class airflow
performance. A surface mounted variable speed control, and 10m control cable,
is supplied along with a plug and lead for the fan. The Blue Jet fan is
suitable for all residential applications. 5 year warranty.
The powerful MixFlo fans have been designed to produce higher working
pressures for applications that require higher airflows with low relative
noise levels. These large bore fans are designed for use with both rigid and
flexible ducting. They offer two and half times the pressure of conventional
axial fans and are dimensionally more compact making them ideal for many
ducted applications. The impeller blade design with guide vanes provides
optimum pressure characteristics. The fan can operate in both horizontal and
vertical positions. Supported by a 4 year warranty or 30,000 continuous hours.
Designer BLUE JET
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching
Product Code
EC
150
40
Mixed Flow
490
165
594
0.24
60
Variable Speed Controller
FAN6960
Pro-Series MIXFLO 3 Speed
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure (Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching
Product Code
85
200
Mixed Flow
60
45
250
272
980
0.31
140
239
860
0.25
80
196
706
0.23
48
Standard FAN1007
45
41
Plug & Lead FAN1053
Pro-Series MIXFLO 2 Speed
Duct (mm)
150 125 100
Fan Type
Max. Fan Watts
(W)
Mixed Flow
70 60
Mixed Flow
40 26
Mixed Flow
40 26
Max. Fan Pressure (Pa)
300 240
220 160
180 120
Free Air Fan Performance
(l/s)
(m3/hr)
166
597
92
330
89
320
72
260
69
250
53
190
Specific Fan Power
(W/l/s)
0.42 0.65
0.45 0.36
0.58 0.49
Sound dB(A)
47 40 43 36 40 33
Switching
Product Code
Standard Plug & Lead
Standard Plug & Lead
Standard Plug & Lead
FAN1006 FAN1048 FAN1005 FAN1051 FAN1004 FAN1050
Inline Extraction Fans – Axial
The Hyper150 EC axial fan is the trusted leader in bathroom extraction. Now
with an EC motor, other ongoing improvements and variable speed control with
10m control cable, Hyper150 continues to lead the field. 7 year warranty.
Ceiling mounted ID and ECO fans have a range of performance levels for short
and efficient duct systems. 2 year warranty.
Classic HYPER150 EC
Duct (mm)
Fan Type
Max.
Max.
Fan Watts Fan Pressure
(W)
(PA)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching Product Code
150
EC Axial
18
91
105
380
0.17
38
Standard FAN0085
Classic STANDARD
Classic ECONOMY
Variable
150
EC Axial
18
91
105
380
0.17
38
Speed
FAN7000*
Controller**
Duct (mm)
150
Fan Type
Max.
Max.
Fan Watts Fan Pressure
(W)
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Axial
25
60
87
313
0.29
125
Axial
20
35
36
130
0.56
100
Duct (mm)
Axial
20
25
23
85
0.87
Fan Type
Max.
Max.
Fan Watts Fan Pressure
(W)
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
40
41
41
Sound dB(A)
Switching
Standard Timer
Standard Timer
Standard Timer
Switching
Product Code
FAN0090 FAN0091 FAN0060 FAN0061 FAN0012 FAN0013
Product Code
150
Axial
25
50
64
230
0.39
40
Standard FAN2078
*All data for FAN7000 at full speed
** Euro flush-box for variable speed control switch included
www.simx.co.nz
9
Inline Fans – Centrifugal 3 Speed
Suitable for a variety of domestic applications, these inline centrifugal fans
provide high performance at your preset choice of speed. Can also be used for
supply. 2 year warranty.
Classic 3 Speed
Duct (mm)
200
150
Fan Type & Speed
Max.
Max.
Free Air Fan Performance
Fan Watts Fan Pressure
(W)
(Pa)
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Centrifugal
(tba)
200
130
466
(tba)
Speed 1
(tba)
275
161
580
(tba)
Speed 2
105
310
180
648
0.58
Speed 3
Centrifugal
Speed 1
41
Speed 2
46
Speed 3
57
225
86
310
0.48
296
122
440
0.38
356
149
535
0.34
Sound dB(A)
(tba) (tba) 56
30 36 43
Switching Order Code Standard FAN0997 Standard FAN0921
Inline Fans – Centrifugal
The following high performance centrifugal inline fans are suitable for a
variety of domestic applications and can also be used for supply. 2 year
warranty.
Classic 3 Speed
Duct (mm)
315 250 200 150 100
Fan Type
Max.
Max.
Free Air Fan Performance
Fan Watts Fan Pressure
(W)
(Pa)
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Centrifugal
318
720
472
1700
0.67
Centrifugal
170
500
280
1010
0.61
Centrifugal
105
418
208
750
0.50
Centrifugal
57
320
124
445
0.46
Centrifugal
32
153
49
176
0.65
Sound dB(A)
52 47 56 50 38
Switching Order Code
Standard Standard Standard Standard Standard
FAN0356 FAN0358 FAN0467 FAN0330 FAN0361
WhisperVent 3 Speed
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max.
Free Air Fan Performance
Fan Pressure
(Pa)
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching Order Code
150
Centrifugal
80
305
124
445
0.65
43
Standard FAN0829
Classic
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max.
Free Air Fan Performance
Fan Pressure
(Pa)
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching Order Code
150
Centrifugal
80
305
124
445
0.65
43
Standard FAN0829
10
www.simx.co.nz
Inline Extraction Fan Kits – CONTOUR Hyper150 EC Axial
Kits are designed so the fascia-fitted adapter plate can be mounted directly
above the steam source (eg: shower or bath). The adapter plate can be finished
in style with a choice of separately ordered fascia from a comprehensive range
of interchangeable round and square fascia options in either black or white
(with or without 10W LED). 5 year warranty.
Designer Standard Profile
Duct (mm)
Fan Type
Max.
Max.
Free Air Fan Performance Specific
Fan Watts Fan Pressure
Fan Power
(W)
(Pa)
(l/s)
(m3/hr)
(W/l/s)
Fascia
Exterior Grille
Switching
Product Code
Range White
150 EC Axial 18
91
105
380
0.17
Selection Fixed Standard FAN7044
(see below) Louvre
Inline Extraction Fans Kits – Mixed Flow
The powerful MixFlo fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels. These large bore fans are designed for use with both rigid and flexible ducting. They offer two and half times the pressure of conventional axial fans and are dimensionally more compact making them ideal for many ducted applications. The impeller blade design with guide vanes provides optimum pressure characteristics. The fan can operate in both horizontal and vertical positions. Supported by a 5 year warranty or 30,000 continuous hours.
Designer Standard Profile
Duct (mm)
Fan Type
Max.
Max.
Free Air Fan Performance Specific
Fan Watts Fan Pressure
Fan Power
(W)
(Pa)
(l/s)
(m3/hr)
(W/l/s)
Fascia
Exterior Grille
Switching
Product Code
Mixed
70
300
166
597
0.42
Range
White
150
Flow
60
240
Selection Fixed Standard FAN7366
92
330
0.65
(see below) Louvre
Fascia Selections (order separately)
White
Black
Round LED White
LED Black
White
Square
Black
LED White
LED Black
DCT4502
DCT4503
DCT4506
DCT4507
DCT4504
DCT4505
DCT4508
DCT4509
Inline Extraction Fan Kits without Lights
These kits are designed so that the interior grille can be mounted directly
above your steam source (e.g. shower or bath). Kits with the low profile
fascia are supplied with a choice of stylish grilles. Mixed flow fans provide
users with a two fan speed option. 5 year warranty.
Pro-Series Low Profile
Classic Standard Profile
Duct (mm) 150 125 100
150
Duct (mm) 150 125
100
Fan Type
Max. Fan Watts (W)
Max. Fan Pressure (Pa)
Mixed Flow
70 60
300 240
Mixed Flow
40 26
220 160
Mixed Flow
40 26
180 120
EC Axial 18
91
Fan Type
Max. Fan Watts (W)
Max. Fan Pressure (Pa)
EC Axial 18
91
Axial
20
35
Centrifugal 20
120
Axial
20
24
Free Air Fan Performance
(l/s) (m3/hr)
Specific Fan
Power (W/l/s)
166 597 0.42 92 330 0.65
89 320 0.45 72 260 0.36
69 250 0.58 53 190 0.49
105 380 0.17
Free Air Fan Performance
(l/s) (m3/hr)
Specific Fan
Power (W/l/s)
105 380 0.17
36 130 0.56
31 110 0.65
23
85
0.87
Fascia
Round White
Round White
Round White
Round White and Square White
Fascia
Round White Round White Round White
Round White
Exterior Grille
Switching
Product Code
Weatherproof Cowl White and Fixed Louvre White
Weatherproof Cowl White and Fixed Louvre White
Weatherproof Cowl White and Fixed Louvre White
Weatherproof Cowl White and Fixed Louvre White
Standard FAN2051 Standard FAN2050 Standard FAN2049 Standard FAN0618
Timer FAN0619
Exterior Grille
Fixed Louvre White Fixed Louvre White Fixed Louvre White Fixed Louvre White
Switching
Product Code
Standard Timer
Standard Timer
Standard
FAN0101 FAN0102 FAN0064 FAN0065
FAN0328
Standard FAN0017 Timer FAN0018
www.simx.co.nz
11
Inline Extraction Fan Kits with LED Lights
These high efficiency inline fans are designed to provide higher levels of
extraction for larger bathrooms and the LED light adds light directly above
your steam source (e.g. shower or bath). Mixed flow fans provide users with a
two fan speed option. 5 year warranty.
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts (W)
Max. Fan Pressure (Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan
Power (W/l/s)
Fascia
150 EC Axial
18
91
105
Round
380
0.17
White
Exterior Grille
Switching
Product Code
Eggcrate White
Standard Timer
FAN5369 FAN5370
125
Axial
20
35
36
Standard FAN5371
130
0.56
Round Eggcrate
White
White
Timer
FAN5372
100 Centrifugal 20
120
31
Standard FAN5373
Round Eggcrate
110
0.65
White
White
Timer
FAN5374
Inline Extraction Fan Kits with Halogen Lights
These high efficiency inline fans are designed to provide higher levels of
extraction for larger bathrooms and the halogen light adds light directly
above your steam source (e.g. shower or bath). Mixed flow fans provide users
with a two fan speed option. 5 year warranty.
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts (W)
Max. Fan Pressure (Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan
Power (W/l/s)
Fascia
150 EC Axial
18
91
105
Round
380
0.17
White
125
Axial
20
35
36
Round
130
0.56
White
Exterior Grille
Switching
Product Code
Eggcrate White
Eggcrate White
Standard Timer
Standard Timer
FAN0803 FAN0804 FAN2037 FAN2038
100 Centrifugal 20
120
31
Round Eggcrate
110
0.65
Timer
FAN0438
White
White
12
www.simx.co.nz
Wall/Ceiling Fans
The new high-pressure and energy-efficient QUIET fans have ultra-high airflow
without nuisance noise and are designed to be ducted straight through a
bathroom or kitchen exterior wall. 5 year warranty.
Designer QUIET
Duct (mm)
Max.
Max.
Free Air Fan Performance
Fan Type Fan Watts Fan Pressure
(W)
(Pa)
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
150 Axial
22
138
114
410
0.19
125 Axial
15
68
54
194
0.28
Sound dB(A)
41
38
Fascia Square Square
Switching
Standard Timer
Humidity Control Standard Timer
Humidity Control
Product Code
FAN7183 FAN7184 FAN7185 FAN7180 FAN7181 FAN7182
Kitchen Fans
CUCINA is a powerful 2 boost speed centrifugal extraction fan with a washable
metal grease filter. The installation selectable speeds are suitable for
kitchens (high speed) or laundries (medium). The fan is G4 and Healthy Homes
compliant for kitchen extract ventilation levels (when installed in through
wall applications at kitchen boost level) and also has a low speed for long
term trickle ventilation. A plate fascia and fine filter kit is also available
as a front grille alternative for laundry installations.
Designer CUCINA
Duct (mm)
Fan Type
Fan Speed and Application
Max.
Max.
Free Air Fan Performance
Fan Watts Fan Pressure
(W)
(Pa)
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching
Product Code
100
Centrifugal
High Medium
Kitchen Laundry
60 41
236 140
73 39
263 140
0.82 1.05
52 38
Pull Cord FAN7201
Plate Fascia and Fine Filter Kit (order separately)
Replacement Washable Metal Grease Filter (order separately)
DCT4529 DCT4562
Through Wall Fans
IntelliVent fans are sensor operated complete with adjustable speed control
and LED function indication. Easy access to the control panel provides for
simple and exact adjustment of settings. Includes energy efficient DC motor. 5
year warranty.
Designer INTELLIVENT
Duct (mm)
100 125
100 125
Fan Type DC Axial DC Axial
Max. Fan Watts
(W)
8
8
Max. Fan Pressure
(Pa)
21
21
Free Air Fan Performance
(l/s)
(m3/hr)
37
134
37
134
Specific Fan Power
(W/l/s)
0.22
0.22
Sound dB(A)
21
21
Fascia Rectangle Rectangle
Switching
Auto Sense Humidity Auto Sense Temperature
Product Code
FAN5901
FAN6051
Through Wall Fan Kits
The new high-pressure and energy-efficient QUIET fan kits have ultra-high
airflow without nuisance noise and are designed to be ducted straight through
a bathroom or kitchen exterior wall. All kits include a weatherproof cowl. 5
year warranty.
The Manrose Genius is the new generation of unitary fans. Following
installation home owners automatically have a ventilation system offering a
wide range of standard default operating settings which can be easily
customised via an intuitive App. Includes energy efficient DC motor. 5 year
warranty.
Designer QUIET
Designer GENIUS
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
150 Axial
22
138
114
410
0.19
41
Square
125 Axial
15
68
54
194
0.28
38
Square
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max.
Free Air Fan Performance
Fan Pressure
(Pa)
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Standard Timer
Humidity Control Standard Timer
Humidity Control
Switching
Product Code
FAN7190 FAN7191 FAN7192 FAN7187 FAN7188 FAN7189
Product Code
100 DC Axial
4
30
30
108
0.13 17-20
Round
App Control
FAN6844
www.simx.co.nz
13
Wall/Ceiling Fans
These axial fans are designed for easy installation and efficient operation.
SELV (safety extra low voltage) models are designed for use in wet area zones
1, 2 and 3 and incorporate a 12V AC motor and a 12V AC isolating transformer.
Auto shutter models have automated backflow prevention vanes. 5 year warranty.
Safety Extra Low Voltage (SELV)
Pro-Series Low Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
150
Axial
20
60
101
364
0.20
40
Classic Standard Profile
125
Axial
20
35
36
130
0.56
41
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
150
Axial
20
60
101
364
0.20
40
125
Axial
20
35
36
130
0.56
41
100
Axial
20
20
23
85
0.87
41
Fascia
Square Round Square Round
Fascia
Square Square Square
Switching
Standard Standard Standard Standard
Switching
Standard Standard Standard
Product Code
FAN5892 FAN5891 FAN5886 FAN5885
Product Code
FAN5896 FAN5890 FAN5883
Auto Shutter
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
150
Axial
25
60
87
313
0.29
40
Square
Switching
Standard Pull Cord
Timer
Product Code
FAN0121 FAN0122 FAN0123
Standard
Pro-Series Low Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
150
Axial
20
60
101
364
0.20
40
125
Axial
20
35
36
130
0.56
41
Classic Standard Profile
Duct (mm)
300 230
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Axial
82
60
306
1100
0.27
60
Axial
45
50
152
550
0.30
50
Fascia
Square Round Square Round Square Round Square Round
Fascia
Square Square
150
Axial
25
60
101
364
0.25
40
Square
125
Axial
20
35
36
130
0.56
41
Square
100
Axial
20
20
23
85
0.87
41
Square
14
www.simx.co.nz
Switching
Standard Standard
Timer Timer Standard Standard Timer Timer
Switching
Standard Standard Standard Pull Cord
Timer PIR Control Standard Pull Cord
Timer Standard Pull Cord
Timer
Product Code
FAN0594 FAN0609 FAN0595 FAN0610 FAN0589 FAN0604 FAN0590 FAN0605
Product Code
FAN2040 FAN0374 FAN0120 FAN0126 FAN0127 FAN0124 FAN0072 FAN0074 FAN0075
FAN0046 FAN0047 FAN0048
Through Wall Fan Kits
These axial fan kits are easy to install and are designed to be ducted
straight through an exterior wall. SELV (safety extra low voltage) fans are
for use in wet area zones 1, 2 and 3 and incorporate a 12V AC motor and a 12V
AC isolating transformer. Auto shutter models have automated backflow
prevention vanes. All kits include a weatherproof cowl. 5 year warranty.
Safety Extra Low Voltage (SELV)
Pro-Series Low Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
150
Axial
20
60
101
364
0.20
40
125
Axial
20
35
36
130
0.56
41
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
150
Axial
20
60
101
364
0.20
40
125
Axial
20
35
36
130
0.56
41
100
Axial
20
20
23
85
0.87
41
Fascia
Square Round Square Round
Fascia
Square Square Square
Switching
Standard Standard Standard Standard
Switching
Standard Standard Standard
Product Code
FAN5894 FAN5893 FAN5887 FAN5888
Product Code
FAN5895 FAN5889 FAN5882
Auto Shutter
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
300
Axial
82
60
306
1100
0.27
60
230
Axial
45
50
152
550
0.30
50
Fascia Square Square
150
Axial
25
60
87
313
0.29
40
Square
Switching
Standard Standard Standard Pull Cord
Timer
Product Code
FAN2043
FAN0348 FAN0136 FAN0137 FAN0138
Standard
Pro-Series Low Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
150 Axial
20
60
101
364
0.20
40
Fascia Square
125 Axial
20
35
36
130
0.56
41
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
330 Axial
82
60
306
1100
0.27
60
230 Axial
45
50
152
550
0.30
50
Square
Fascia Square Square
150 Axial
25
60
101
364
0.20
40
Square
125 Axial
20
35
36
130
0.56
41
Square
100 Axial
20
20
23
85
0.87
41
Square
www.simx.co.nz
Switching
Standard Timer
Standard Timer
Switching
Standard Standard Standard Pull Cord
Timer Standard Pull Cord
Timer Standard Pull Cord
Timer
Product Code
FAN0621 FAN0623 FAN0614 FAN0615
Product Code
FAN2042 FAN0455 FAN0135 FAN0140 FAN0141 FAN0080 FAN0082 FAN0083 FAN0053
FAN0054 FAN0055
15
Window Fans
These axial fans are designed for installation situations where an existing
window fan is being replaced or where there is no available external wall, or
ceiling, space access. SELV fans are designed for use in wet area zones 1, 2
and 3 and incorporate a 12V AC motor and a 12V AC isolating transformer. Auto
shutter models have automated backflow prevention vanes. 5 year warranty.
Safety Extra Low Voltage (SELV)
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Product Code
100
Axial
20
20
23
85
0.87
41
Square
Pull Cord FAN5884
Safety Extra Low Voltage (SELV) & Auto Shutter
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Product Code
150
Axial
25
60
87
313
0.29
40
Square
Pull Cord FAN5897
Auto Shutter
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
150
Axial
25
60
87
313
0.29
40
Square
Standard
Classic Standard Profile
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Product Code
Pull Cord FAN0107
Pull Cord Timer
FAN0109
Switching
Product Code
100
Axial
20
20
23
85
0.87
41
Square
Pull Cord FAN0021
Wall Fans – Internal
Internal wall fans are designed to move air efficiently over long distances
with the centrifugal fan providing quiet operation.
Standard
Classic Standard Profile Rectangular Fascia
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Fascia
Switching
Product Code
100 Centrifugal
45
120
31
110
1.45
45
Rectangular
Standard
FAN0041
16
www.simx.co.nz
Heat-Fan-Light Systems
These multi-function systems are designed to meet the higher operational
demands of both small and large bathrooms. Fans incorporate a unique anti-
condensate design and efficient heating system. All systems are supplied with
duct, grille and wall switch.
4 & 2 Light Units
Designer Low Profile
Total Duct Fan Type Watts
(W)
Free Air Fan Performance
(l/s)
(m3/hr)
150
2x Centrifugal
2115
106
380
Heat Element
2 Level PTC 1100/2000W
Fascia
Product Code
White Black
FAN7020 FAN7021
150 Centrifugal 1100
69
248
1 x 1000W Halogen
White
FAN6577
Pro-Series Vivo
Designer SATIN Low Profile
150 Centrifugal 1080
99
356
Total Duct Fan Type Watts
(W)
Free Air Fan Performance
(l/s)
(m3/hr)
125 Centrifugal 2100
92
330
Total Duct Fan Type Watts
(W)
Free Air Fan Performance
(l/s)
(m3/hr)
125 Centrifugal 1138
84
303
1 x 1000W Halogen
Heat Element 2 Level PTC 1400/2000W Heat Lamps
4 x 275W
Pro-Series Low Profile
Classic Standard Profile
125 Centrifugal 588
75
270
Total Duct Fan Type Watts
(W)
125 Centrifugal 1180
Free Air Fan Performance
(l/s)
(m3/hr)
60
216
125 Centrifugal 635
Total Duct Fan Type Watts
(W)
50
180
Free Air Fan Performance
(l/s)
(m3/hr)
100 Centrifugal 670
35
126
2 x 275W Heat Lamps
4 x 275W 2 x 275W Heat Lamps 2 x 275W
White
FAN5876
Fascia
Product Code
White
FAN7291
Fascia
Product Code
White Silver White Silver
FAN6882 FAN6883 FAN6880 FAN6881
Fascia
Product Code
White
FAN0995
White
FAN0940
Fascia
Product Code
White
FAN2162
Heat-Light System
The Heat-Light system is designed to provide instant heat and additional
lighting. A 150mm inline extraction fan kit, or Blue Jet fan and ducting
combination can be added for a complete HEAT-FAN-LIGHT solution. 5 year
warranty.
2 Light Units
Classic Standard Profile
Duct (mm)
Total Watts (W)
Heat Lamps
Fascia
Product Code
Manrose Heat-Fan-Light systems have been teste1d0t0omthme downlight standard AS/NZS665005W98.2.2 Amendment A and a2rex a2l7l c5lWassified as CA135.
White
FAN2200
www.simx.co.nz
17
Through Roof Fan Cowls and Through Roof Fan Kits
Through Roof Fan Cowls – Air Extraction
Classic
Duct (mm)
150 150 150
Fan Type
Centrifugal Centrifugal 3-Speed
EC Axial
Max. Fan Watts
(W)
70
70
18
Max. Fan Pressure
(Pa)
320
320
91
Free Air Fan Performance
(l/s)
(m3/hr)
153
550
153
550
105
380
Specific Fan Power
(W/l/s)
0.46
0.46
0.17
Sound dB(A)
62 62 38
Switching
Standard Standard Standard
Product Code
FAN0529 FAN1002 FAN0531
Through Roof Fan Cowls – Air Supply
Classic
Duct (mm)
Fan Type
150
EC Axial
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching
Product Code
18
91
105
380
0.17
38 Standard FAN0533
Through Roof Fan Kits with Flashing & HDPE Tube – Air Extraction
Classic
Duct (mm)
150 150 150
Fan Type
Centrifugal Centrifugal 3-Speed
EC Axial
Max. Fan Watts
(W)
70
70
18
Max. Fan Pressure
(Pa)
320
320
91
Free Air Fan Performance
(l/s)
(m3/hr)
153
550
153
550
105
380
Specific Fan Power
(W/l/s)
0.46
0.46
0.17
Sound dB(A)
62 62 38
Switching
Standard Standard Standard
Product Code
FAN0530 FAN0967 FAN0532
Through Roof Fan Heavy Duty Kits with Flashing & HDPE Tube – Air Extraction
Classic
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching
Product Code
150
Centrifugal
70
320
153
550
0.46
62 Standard FAN0740
150
EC Axial
18
91
105
380
0.17
38 Standard FAN0739
Through Roof Fan Kits with Flashing & HDPE Tube – Air Supply
Classic
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching
Product Code
150
EC Axial
18
91
105
380
0.17
38 Standard FAN0534
Through Roof Fan Kits with Flashing for Metal Based Roof – Air Extraction
Classic
Duct (mm)
Fan Type
Max. Fan Watts
(W)
Max. Fan Pressure
(Pa)
Free Air Fan Performance
(l/s)
(m3/hr)
Specific Fan Power
(W/l/s)
Sound dB(A)
Switching
Product Code
150
Centrifugal
70
320
153
550
0.46
62 Standard FAN0535
150
EC Axial
18
91
105
380
0.17
38 Standard DCT0189
18
www.simx.co.nz
Duct, Grilles and Accessories
Ducting
Aluminium Flexible Duct x 3m 150mm 125mm 100mm
Acoustic Duct x 3m 150mm
PVC Flexible Duct 150mm x 3m 125mm x 4m 100mm x 5m
Semi-Rigid Duct x 3m 150mm 125mm 100mm
DCT0330 DCT0329 DCT0328
DCT0633
DCT0338 DCT0337 DCT0336
DCT0116 DCT0115 DCT0114
Duct Accessories
Inline Backdraught Shutters 150mm PVC 125mm PVC 100mm PVC
Duct Joiners 150mm Metal 125mm Metal 100mm PVC
Door Grille Door Grille
Duct Connectors Cable Ties – 150mm Cable Ties – 125mm Cable Ties – 100mm Duct
Tape – 48mm x 5m Duct Tape – 48mm x 30m
DCT0511 DCT0036 FAN0213
DCT0059 DCT0037 DCT0159
FAN0159
FAN0282 FAN0281 FAN0274 DCT0173 DCT0807
Interior Grilles/Soffit Grilles
Low Profile Grilles – Round Plastic 150mm – Matte Black 150mm – Gloss White
125mm – Gloss White 100mm – Gloss White
Low Profile Grilles – Square Plastic 150mm – Matte Black 150mm – Gloss Black
150mm – Gloss White 125mm – Gloss White 100mm – Gloss White
Standard Profile Grilles – Round Plastic 150mm – Matte Black 150mm – Gloss
Black
Flat Face Grilles – Square Plastic
DCT4401 DCT1067 DCT1090 DCT1089
DCT4259 DCT4314 DCT2225 DCT2224 DCT2223
DCT4257 DCT4315
150mm – Matte Black
DCT4371
Eggcrate Grilles – White Plastic
150mm 125mm 100mm
DCT0473 DCT0472 DCT0375
Exterior Grilles
Weatherproof Cowls (includes flap and bird mesh)
150mm – Matte Black Plastic 125mm – Matte Black Plastic 100mm – Matte Black
Plastic 150mm – Gloss Black Plastic 150mm – Gloss White Plastic 125mm – Gloss
White Plastic 100mm – Gloss White Plastic 150mm – Stainless Steel 125mm –
Stainless Steel 100mm – Stainless Steel
Gravity Shutter Grilles
150mm – Black Plastic 150mm – White Plastic 125mm – White Plastic 100mm –
White Plastic 150mm – Stainless Steel 125mm – Stainless Steel 100mm –
Stainless Steel
Fixed Louvre Grilles – Square Plastic
150mm – Matte Black 125mm – Matte Black 100mm – Matte Black 150mm – Gloss
Black 150mm – Gloss White 125mm – Gloss White 100mm – Gloss White
DCT4261 DCT4399 DCT4400 DCT4316 DCT1031 DCT1030 DCT0018 DCT3616 DCT3615
DCT3614
DCT4320 DCT0066 DCT0044 DCT0029 DCT2147 DCT2146 DCT2145
DCT4373 DCT4429 DCT4428 DCT4319 DCT0063 DCT0041 DCT0025
Extraction Grilles
Extraction Grilles – Round Plastic 150mm – Gloss White 125mm – Gloss White
100mm – Gloss White
DCT2187 DCT2186 DCT2185
Roof Cowl Kits
General Purpose with Flashing & HDPE Tube
150mm
DCT0172
General Purpose with Lead Flashing & HDPE Tube
150mm
DCT1095
Heavy Duty with Flashing & HDPE Tube
150mm
DCT0710
Fan Timers
Timer – Fixed Run On Time (approx), AC only
Fan On Time up to 5 mins over 5 mins
Run On Time 7 mins 12 mins
Code FAN0372
Timer – Adjustable Run On Time & Start Delay, AC/EC
Fan On Time up to 5 mins
Run On Time up to 20 mins
Code FAN2444
Transformer
Electronic Transformer 12V AC, 50KHz Transformer
FAN2101
SELV Isolating Transformer 12V AC Transformer
FAN0436
www.simx.co.nz
19
Manrose leads the market in air movement and air extraction. Developed and
designed to meet the specific application needs of the New Zealand market,
Manrose fans perform to those exacting standards for the life of the product.
Manrose ducting, fans, fan kits and air movement accessories deliver elegance
and innovation in reliable and durable solutions everytime.
For the full range of
fans, ducting, grilles, diffusers,
hand dryers and accessories visit our website
www.manrose.co.nz
Distributed by Simx Limited. Specifications are subject to change without notice.
Dealers Details PUB0076 2311
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>