Installation
- Installation must be carried out by a qualified engineer in accordance with local regulations.
- Disconnect supply before installing.
- Install to a solid surface – vibrations may cause mistriggering.
- Ensure environmental conditions are Suitable for electronic equipment
Technical Specifications
Rotary Switch Settings
A rotary switch is built inside the sensor for scene selection / fast programming. Total 16 channels available
Sensor Mode Selection
Sensor mode can be easily selected by choosing the correct combination of the DIP switches
- HF+PIR: Light is on when both HF and PIR sensors are activated.
- HF/PIR: Light is on when HF or PIR sensors are activated.
Functions
Daylight Harvest (Daylight Regulating)
The built-in daylight sensor can measure ambient natural light, and calculate how much electrical light is needed to reach the target lux level. The demand is given to the LED driver by DALI signal, so as to deliver the needed amount of electric light. The target lux level can be adjusted by remote control or long press on the push switch
Lux Off Function
The light dims to minimum level even switches off completelly if ambient daylight is sufficient (natural light level exceeds target lux level), no matter it is during hold-time or stand-by time, with or without motion. Note: if the stand-by time is preset at “+∞”, the light never turns off even when natural light is sufficient.
Manual Override (Push Function)
With the help of a push-switch, this sensor may be overridden by the end-users to switch on/off the lights manually or adjust the target lux level. This makes the product more user-friendly and offers more options to fit for extra- ordinary demands. Short push (<1s): on/off function;
ON: the light turns off immediately and cannot be lightened for a certain time
(equals to hold time preset) even if movement is detected. After this period,
the sensor goes back to auto sensor mode.
OFF: the light turns on and goes to auto sensor mode. Long push (>1s): adjust
the target lux level by turning the light up or down. Both the adjustment by
remote control and push switch can overwrite each other, the last adjustment
remains in memory.
Semi-auto Function (Absence Detection)
The motion sensor is employed, but only activated on the manual press of the
push switch. With presence, the light remains on and can interact with ambient
natural light, then dims down in absence, eventually switching off
automatically after the stand-by time has expired. Note: end-user can choose
either function 5.3 or 5.4 for application. Default function is 5.3. By
connecting the “SYNC” terminals in parallel (see wiring diagram), no matter
which sensor detects motion, all HIM14 in the group will tun on the lights
when surrounding natural light is below the daylight threshold. The sensor
module is shared and the detection area could be widely enlarged in this way.
Casing option 1
Casing option 2
Direct junction “J” box mounting
- Separate control board (A) from facia (B) & junction bOx (C).
- Make electrical connections to control board (A). See detailed wiring diagram on next page
- Secure control board (A) to junction box.
- Set-up sensor modes as per sections 3 & 4 of this manual.
- Clip facial plate (B) to control board (A).
Surface mount assembly
- Separate control board (A) from facia (B) & Surface box (C).
- Securely mount surface box (C) to a flat and solid surface.
- Make electrical connections to control board (A). See detailed wiring diagram on next page.
- Set-up sensor modes as per sections 3 & 4 of this manual.
- Secure control board (A) to surface box (C).
- Clip facial plate (B) to control board (A.
Wiring Diagram
Detection Pattern
Description of the Button Functions (remote control HRC-11)
Permanent ON/OFF [button
- Press button to select permanent ON or permanent OFF mode.
- Press button/@to resume automatic operation.
- The mode will change to AUTO Mode after power failure.
RESET [ button
Press button @, all settings go back to the rotary switch settings. Sensor mode return to DiP switch setings.
Shift [ button
- Press button, the LED on the top let corner tlashes for indication.
- All values/ settings in RED are in valid for 20 seconds.
Auto Mode [button
- Press button@to initiate automatic mode. Ihe sensor starts working and all settings remain as before the light was switched ONOFF.
Semi-auto Mode [ button O &®]
- Press button Shift (the red LED flashes for indication),
- press button to initiate semi-auto mode. The fixture is manually on by push-switch and automatically off in semi-auto mode.
Power output button
Press out on 6, tne ignt Output shifts between 80% and 100%. Note: the function of Sensor off and “light” are disabled.
Brightness +/- [button ©]
Press the button to adjust light brightness to reset the target lux level.
Scene prog. [ zone O] (One-key-commissioning)
- Press the button “start” to program.
- Select the buttons in “Detection range”, O/®°Daylight threshold”,
- Hold time”, ®’Stand-by time”, Stand-by dimming level” to Set all parameters.
- Press button “Memory to save all the settings programmed in the remote Control.
- Press button “Apply” to set the settings to each sensor unit(s).
- For example, to pre-set detection range 100%, daylight threshold
- Disable, nod time bmin, stand-oy tme +oo, stand-by dimming level 30%, steps should be:
- Press button Start, button100%, Disable, Shift, O5min,
Detection range [ zone O)
Press buttons in zone to set HF detection range at 100%/ 75%%/ 50% 10%
Daylight threshold [ zone O]
- Press buttons in zone to set the daylight sensor at 50Lux/ 100Lux 300Lux/500Lux or Disable as threshold/target Lux level.
Note: 2Lux/ 10Lux are disabled.
- To set daylight sensor at 100Lux/ 300 Lux/500Lux, press button Shift at first.
Ambient daylight threshold [ button]
- Press buttonOShift, the red LED flashes for indication.
- Press button o, the ambient lux level is sampled and set as daylight threshold/target Lux level.
Hold time[ zone DJ
- Press buttons in zone Oto set the hold time at 2s /30s / 1min / 5min/10min /15min / 20min/30min.
Note:
To set hold-time at 30s/ 5min /15min /30min, press button Shift at first. 2. 2s is for test purpose only, stand-by time and daylight sensor settings are disabled in this mode. lo exit from lest mode, press buttonor any button in zone.
Stand-by time [ zone1
- Press buttons in zoneto set the stand-by time at 0s/ 10s/ 1min/
- Smin /10min /30min / 1h/ +oo.
Note: “0s” means on/off control; “+eo” means bi-level control, 100% on when motion detected, and remains at the stand-by dimming level wnen no presence after nold-tume.
Stand-by dimming level [ zone9]
Press buttons in zone ®to set the stand-by dimming level at 10% 20%/30%/50%.
Daylight harvest auto-configuration function
- Press button “Shift”, the red LED is on for indication.
- Select a time period and the sensor will do light level measurement and determine/save the lowest light level (commission line) with 100% light on, so as to set the target lux level automatically.
Note:
- Make sure the light level measurement covers the night time.
- Ihe tbture il go into sensor mode after the measurement, all sensor settings remain unchanged
Dual tech & RF mode [ zone 9]
- Press butons in zone to select sernsor technology.
- HE+PIR: Light is on when both HF and PIR sensors are activated.
- HFPIR: Light is on when HF or PIR sensors are activated.
- Learn/Erase, Transmit, RX100% and RX STBY% are disabled.