AFX 16-2012 LED Par Projector 28 X 10W RGBW Instructions

June 15, 2024
AFX

AFX-logo

AFX 16-2012 LED Par Projector 28 X 10W RGBW

AFX-16-2012-LED-Par-Projector-28 X 10W-RGBW-product

CONNECTORS (fig. 1)
DISPLAY (fig. 2)

AFX-16-2012-LED-Par-Projector-28 X 10W-RGBW-fig-1

INSTALLATION DIAGRAM (fig. 3)
FIXTURE LINKING (fig. 4)

AFX-16-2012-LED-Par-Projector-28 X 10W-RGBW-fig-2

PHOTOMETRIC DIAGRAM (fig. 5)
DIMENSIONS (fig. 6)

AFX-16-2012-LED-Par-Projector-28 X 10W-RGBW-fig-3

DMX CHANNELS

CH13| CH29|  |
---|---|---|---
1| 1|  | Dimmer
0..255| Dimmer 0%…100%





2

| ****




2

|  | Shutter
0..31| Shutter closed
32..63| shutter open
64..95| Strobe effect slow to fast
96..127| shutter open
128..159| Pulse-effect in sequences slow to fast
160..191| shutter open
192..223| Random strobe effect slow to fast
224..255| shutter open
3| 3|  | Red
0..255| 0-100% Red dimmer from dark to bright
4| 4|  | Green
0..255| 0-100% Green dimmer from dark to bright
5| 5|  | Blue
0..255| 0-100% Blue dimmer from dark to bright
6| 6|  | White
0..255| 0-100% White dimmer from dark to bright
7| 7|  | Focus
0..255| ln(near) to out(far)
 | 8|  | Red1
0..255| Red in pixel 1 saturation control (0-100%)
 | 9|  | Green 1
0..255| Red in pixel 1 saturation control (0-100%)
 | 10|  | Blue1
0..255| Red in pixel 1 saturation control (0-100%)
 | 11|  | White1
0..255| Red in pixel 1 saturation control (0-100%)
 | 12|  | Red2
0..255| Red in pixel 2 saturation control (0-100%)
 | 13|  | Green2
0..255| Red in pixel 2 saturation control (0-100%)
 | 14|  | Blue2
0..255| Red in pixel 2 saturation control (0-100%)
 | 15|  | White2
0..255| Red in pixel 2 saturation control (0-100%)
 | 16|  | Red3
0..255| Red in pixel 3 saturation control (0-100%)
 | 17|  | Green3
0..255| Red in pixel 3 saturation control (0-100%)
 | 18|  | Blue3
0..255| Red in pixel 3 saturation control (0-100%)
 | 19|  | White3
---|---|---|---
0..255| Red in pixel 3 saturation control (0-100%)
 | 20|  | Red4
0..255| Red in pixel 4 saturation control (0-100%)
 | 21|  | Green4
0..255| Red in pixel 4 saturation control (0-100%)
 | 22|  | Blue4
0..255| Red in pixel 4 saturation control (0-100%)
 | 23|  | White4
0..255| Red in pixel 4 saturation control (0-100%)












8

| ****











24

|  | Macro Color
0..15| No Function
16..31| Red
32..47| Green
48..63| Blue
64..79| White
80..95| Red+Green
96..111| Red+Blue
112..127| Red+White
128..143| Green+Blue
144..159| Green+White
160..175| Blue+Wtihe
176..191| R+G+B
192..207| R+G+B+W
208..212| 2700K
213..217| 3200K
218..222| 3500K
223..227| 5000K
228..232| 5500K
233..237| 6000K
238..242| 6500K
243..247| 7000K
248..255| 8000K





9

| ****




25

|  | Color Temp
0..15| No Function
16..45| Below3200K
46..75| 3200K – 3500K
76..105| 3500K – 5000K
106..135| 5000K – 5500K
136..165| 5500K – 6000K
166..195| 6000K – 6500K
196..225| 6500K – 7000K
226..255| 7000K – 8000K









10

| ****








26

|  | Macro RUN
---|---|---|---
0..15| No function
16..31| Macro Run 1
32..47| Macro Run 2
48..63| Macro Run 3
64..79| Macro Run 4
80..95| Macro Run 5
96..111| Macro Run 6
112..127| Macro Run 7
128..143| Macro Run 8
144..159| Macro Sound 1
160..175| Macro Sound 2
176..191| Macro Sound 3
192..207| Macro Sound 4
208..223| Macro Sound 5
224..239| Macro Sound 6
240..255| Macro Sound 7
11| 27|  | Macro Speed
0..255| Macro Speed from Slow To Fast









12

| ****








28

|  | Dynamic Rotate
0..15| No function
16..31| Dynamic Rotate  1
32..47| Dynamic Rotate  2
48..63| Dynamic Rotate  3
64..79| Dynamic Rotate  4
80..95| Dynamic Rotate  5
96..111| Dynamic Rotate  6
112..127| Dynamic Rotate 7
128..143| Dynamic Rotate  8
144..159| Dynamic Rotate  9
160..175| Dynamic Rotate 10
176..191| Dynamic Rotate 11
192..207| Dynamic Rotate 12
208..223| Dynamic Rotate 13
224..239| Dynamic Rotate 14
240..255| Dynamic Rotate 15
13| 29|  | Dynamic Rotate Speed
0..255| from Slow To Fast

FEATURES

  • 28x 10W RGBW LED
  • 13/29 DMX channels
  • Smooth electronic linear zoom 12-60°
  • CTB & CTO, linear colour temperature adjustment from 2800-8000°K
  • Strobe & pulse strobe effect
  • Auto, DMX, master-slave, music and remote controlled operation
  • Powercon in-/outputs
  • IR remote control included

EXPLANATION OF SYMBOLS

AFX-16-2012-LED-Par-Projector-28 X 10W-RGBW-fig-4

CAUTION
DO NOT OPEN THE HOUSING SHOCK HAZARD

SAFETY RECOMMENDATIONS

  • Please read these instructions carefully, they include important information about the installa-tion, usage and maintenance of this product.
  • Please keep this User Guide for future reference.
  • Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the bottom of the fixture.
  • The appliance is part of class I and must exclusively connected to an earthed mains outlet.
  • This product is intended for indoor use only!
  • To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.
  • The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
  • The minimum distance luminaire from that part of the luminaire or lamp to the lighted object is 0.5m. 0.5m
  • The max. ambient temperature (Ta) is 40°C. Don’t operate the fixture at higher temperatures.
  • The surface temperature of the unit may reach up to 85°C. DO NOT TOUCH the housing bare-hand during its operation. Turn off the power and allow about 20 minutes for the unit to cool down before replacing or servicing.
  • DO NOT OPEN the unit within 5 minutes after switching off.
  • In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction.v
  • Make sure the power cord is never crimped or damaged.
  • Avoid direct eye exposure to the light source while it is on as sensitive persons may suffer an epileptic shock (especially meant for epileptics)!.
  • The product is for decorative purposes only and not suitable as a household room illumination.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  • The lenses, housing or ultraviolet filter must be replaced if they are visibly damaged.
  • Please note that the lamp of this device cannot be replaced. If the lamp is faulty, the unit must be discarded

DISCONNECT DEVICE
Please note that the unit DOES NOT have an ON/OFF switch. Please unplug the unit to remove completele the power from the internal circuits before cleaning or servicing. Therefore, the discon-nect device shall remain readily accessible.

FUSE REPLACEMENT

  • Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
  • With a screwdriver wedge the fuse holder out of its housing.
  • Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
  • Insert the fuse holder back in its place and reconnect power.
  • Warning: If after replacing the fuse you continue to blow fuses, STOP using the unit. Contact cus-tomer support for further instructions. Continuing to use the unit may cause serious damage.

FIXTURE LINKING (FIG4)
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all fixtures on a serial data link determines the number of fixtures that the data link can support.
Important: Fixtures on a serial/data link must be daisy chained in one single line.

DATA CABLING
To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.

DMX CONNECTOR CONFIGURATION
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.

INSTALLATION (FIG.3)
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope. Never stand directly below the device when mounting, removing or servicing the fix-ture. This fixture may be mounted in any position provided there is adequate room for ventilation.

POWER LINK
Connect a POWERCON cable from the POWER OUT connector of the 1st unit to the POWER IN con-nector of the second unit, etc.

CONTROL PANEL (FIG. 2)
To access the main menu press the MENU button. Press the UP or DOWN buttons until you reach function you wish to change. When you reach the function you wish to change, press the ENTER button. When a function is selected, use the UP or DOWN buttons to change the function settings.  Once your changes are made, press the ENTER button. Check the following function table :

MENU|
---|---

RUN MODE

|

ADDR

| VALU| A001~A XXX (AXXX)|
SLAV|  |  |

AUTO

| Program1

Program8

| ALON /(AU-A)|

SP_1~SP_5 (Speed)

|

MAST /AU-M)

SOUN

|

Program1-7

| ALONE|
MASTER|

SET

| MIC| M-00-99%|  |
RELOAD| ON/OFF|  |
VERSION| V-2.0|  |

CAL

| Code (password: 088)|
CH03-CH06|

DMX

| CH13|  |  |
CH29|  |  |
REST| ON/OFF|  |  |

MANU

| RXXX| 000-255|  |
GXXX| 000-255|  |
BXXX| 000-255|  |
WXXX| 000-255|  |
 | FXXX| 000-255|  |
TEMP| TXXX|  |  |

DMX channel chart: please refer to page 3-5
IR REMOTE CONTROLLER
Please operate the remote control within a distance of 6m and 30° between the remote and the appliance. Aim the remote at the sensor. Remove all obstacles between the remote and the sensor. The remote control might not work properly if the sensor is exposed to strong sunshine. If the remote control doesn’t work properly, please check the batteries.

INSTALLING THE BATTERIES IN THE REMOTE CONTROL

  • Place the remote face down on a flat surface.
  • Push the compartment cover into the direction of the arrow.
  • Slide the battery compartment open.
  • Remove the old battery and install the new one (CR2025) with the plus (+) sym-bol facing up.
  • Gently slide the battery compartment closed. It locks automatically.

RECOMMENDATIONS FOR BATTERIES

This symbol indicates that used batteries should not be disposed of with household waste but deposed correctly in accordance with your local regulations.. Batteries shall not be exposed to excessive heat such as sunshine, fire or the like.When the internal batteries are not to be used, remove them to avoid damage caused by battery leakage or corrosion.

ATTENTION : Danger of explosion if battery is incorrectly placed. Only replace by the same or equivalent type.
WARNING :Do not swallow the battery. Danger of chemical burns. Keep new and old batteries out of the reach of children. If the battery compartment doesn’t close properly, stop using the product and keep it out of the reach of children.
If you are in doubt whether the batteries have been swallowed or introduced into any other part of the body, contact immediately a doctor.

REMOTE CONTROL

AFX-16-2012-LED-Par-Projector-28 X 10W-RGBW-fig-7

NOTE: PLEASE SET THE UNIT TO MODE -> ADDR, OTHERWISE THE REMOTE CONTROL WILL NOT WORK

  1. BRIGHTNESS & SPEED adjustment: Press and in programme mode
  2. ON/OFF of the LEDs.
  3. SELECT BASIC COLOR:
    • R: Red
    • G: Green
    • B: Blue
    • W: White
  4. COLOUR BUTTONS: For constant lighting of one colour, press the corresponding button.
  5. SELECT AN INTERNAL PROGRAMME
    • FLASH: Colour change
    • STROBE: Colour strobe
    • FADE: Colour fade

CLEANING AND USING FREQUENCY OF PRODUCT

Please make sure that the light is power off before dismantling or maintaining, it’s very important to keep the light clean. Frequent cleaning will ensure maximum brightness output, but also prolong the life time. It’s suggested to use the high quality, professional glass detergent and soft cloth to clean the light. It’s not allowed to use alcohol or chemical solvent. The front objective lens requires weekly cleaning as smoke-fluid tends to build up residues, thus reducing the light output very quickly. The cooling fans should be cleaned monthly. The inner part of the light should be cleaned by vacuum cleaner or an air-jet at least once a year.

Important! Check the air filters periodically and clean before they become clogged! Clean the two air filters that are placed in the fixture’s covers and two in the fixture’s base. Use a vacuum cleaner, compressed air or wash and dry them before they put them back. After replacing the air filters, reset the elapsed time counter in the menu “Information” (Informa-tion -> Air Filters -> Elapsed time.) When the light doesn’t work, please check if the fuse is burnt out or not. If it is, the same fuse should be replaced, find out the faulty and restart the light. But please note the repair must be handled by professional.

TECHNICAL SPECIFICATIONS

  • Power Supply…………………………………………………………………………………………………………90-240V~50/60Hz
  • Consumption……………………………………………………………………………………………………………………………. 285W
  • Light source………………………………………………………………………………………………………..28 x 10W RGBW LED
  • Dimensions………………………………………………………………………………………………………….265 x 213 x 117mm
  • Weight……………………………………………………………………………………………………………………………………..2.54kg

IMPORTANT NOTE: Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your dealer about the way to proceed.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AFX User Manuals

Related Manuals