Danby DPA135E1WDB Portable Air Conditioner Owner’s Manual
- June 15, 2024
- Danby
Table of Contents
Danby DPA135E1WDB Portable Air Conditioner
Welcome to the Danby family
We are proud of our quality products and we believe in dependable service. We suggest that you read this owner’s manual before plugging in your new appliance as it contains important operation information, safety information, troubleshooting, and maintenance tips to ensure the reliability and longevity of your appliance.
You are entitled to the warranty coverage as described in the owner’s manual provided with your new appliance.
- Please write down your appliance information below. You must keep the original proof of purchase receipt to validate and receive warranty services.
- Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION after filling out a product survey, at www.danby.com/support/product-registration/
Need Help?
- Read your Owner’s Manual for installation help, troubleshooting, and maintenance assistance.
- Visit www.Danby.com to access self-service tools, FAQs and much more by searching your model number in the search bar.
- For the Quickest Customer Service, please fill out the web form at www.danby.com/support. Your submission will go directly to an expert on your particular appliance. Our average response times are between 20 minutes and 2 hours, during EST business hours.
- Call 1-800-263-2629 – please note that during peak hours, hold times can exceed one hour.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAFETY REQUIREMENTS
DANGER: Risk of fire or explosion. Flammable refrigerant used. Do not damage the refrigerant circuit.
- Ensure that servicing is done by factory authorized service personnel, to minimize product damage or safety issues.
- Consult repair manual or owner’s guide before attempting to service this product. All safety precautions must be followed.
- Dispose of properly in accordance with federal or local regulations.
- Follow handling instructions carefully.
- Keep ventilation openings, in the appliance clear of obstruction.
- Do not use mechanical devices or other means to accelerate the defrosting process.
- Children should be supervised to ensure that they do not play with the appliance.
- Do not store or install the appliance near continuously operating ignition sources such as open flames or a gas stove.
- Do not operate near water or in a wet room.
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odor.
- The appliance must be stored so as to prevent mechanical damage from occurring.
All wiring must comply with local and national codes and must be installed by a qualified electrician. Check the available power supply and resolve any wiring problems before installing and operating this appliance.
The rating plate located on the right side of the appliance just above the power cord contains electrical and other technical data.
This appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities may be different or reduced, or who lack experience or knowledge, unless such persons receive supervision or training to operate the appliance by a person responsible for their safety.
GROUNDING INSTRUCTIONS
This appliance must be grounded. Grounding reduces the risk of electrical shock by providing an escape wire for the electrical current.
This appliance has a cord that has a grounding wire with a 3-prong plug. The power cord must be plugged into an outlet that is properly grounded. If the outlet is a 2-prong wall outlet, it must be replaced with a properly grounded 3-prong wall outlet. The serial rating plate indicates the voltage and frequency the appliance is designed for.
WARNING – Improper use of the grounding plug can result in a risk of electric shock. Consult a qualified electrician or service agent if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.
Do not connect your appliance to extension cords or together with another appliance in the same wall outlet. Do not splice the power cord. Do not under any circumstances cut or remove the third ground prong from the power cord. Do not use extension cords or ungrounded (two prongs) adapters.
If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified person in order to avoid hazard.
CAUTION: RISK OF FIRE
Flammable refrigerant used. When maintaining or disposing of the air conditioner, the refrigerant must not be allowed to vent into the open air.
SAVE THESE INSTRUCTIONS!
Any person involved with working on the refrigerant circuit should hold a current, valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
When maintaining or disposing of the appliance the refrigerant must be recovered properly and should not be allowed to discharge to the air directly.
Information on servicing
-
Checks to the area: Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
-
Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapour being present while the work is being performed.
-
General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the work area have been made safe by removing all flammable material.
-
Checking for the presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non sparking, adequately sealed and intrinsically safe.
-
Presence of fire extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available on hand. Have a dry powder or C02 fire extinguisher adjacent to the work area.
-
No ignition sources: No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to risk of fire or explosion. All possible ignition sources including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure there are no flammable hazards or ignition risks. No smoking signs shall be displayed.
-
Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferable expel it externally into the atmosphere.
-
Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.
he following checks shall be applied to installations using flammable refrigerants: The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
The following checks shall be applied to installations using flammable refrigerants:- The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
- The ventilation machinery and outlets are operating adequately and are not obstructed.
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
- Marking to the equipment continues to be visible and legible. Markings and signs that become illegible must be corrected.
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitable protected against being corroded.
-
Checks to electrical devices: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
- That capacitors are discharged. This shall be done in a safe manner to avoid possibility of sparking.
- That no live electrical components and wiring are exposed while charging, recovering or purging the system.
- That there is continuity of earth bonding.
Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- To ensure that by working on electrical components the casing is not altered in such a way that the level of protection is affected, particular attention shall be paid to the following:
- Damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
- Ensure the apparatus is mounted securely.
- Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
Note: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch or any other detector using a naked flame shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants:
- Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not be adequate or may need recalibration. Detection equipment shall be calibrated in a refrigerant-free area. Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
- Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confirmed.
- Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper or pipe-work.
- If a leak is suspected, all naked flames shall be removed or extinguished.
- If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that the best practice is followed since flammability is a consideration. The following procedures shall be adhered to:
- Remove refrigerant.
- Purge the circuit with inert gas.
- Evacuate.
- Purge again with inert gas.
- Open the circuit by cutting or brazing.
- The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task.
- Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OF ON charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital is brazing operations on the pipe-work are to take place.
- Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed:
- Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- Label the system when charging is complete, if not already labeled.
- Extreme care shall be taken not to overfill the refrigeration system.
- Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment in all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
- A. Become familiar with the equipment and its operation.
- B. Isolate system electrically.
- C. Before attempting the procedure ensure that:
- Mechanical handling equipment is available if required for handling refrigerant cylinders.
- All personal protective equipment is available and being used correctly.
- The recovery process is supervised at all times by a competent person.
- Recovery equipment and cylinders conform to the appropriate standards.
- D. Pump down refrigerant system, if possible.
- E. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- F. Make sure that cylinder is situated on the scales before recovery takes place.
- G. Start the recovery machine and operate in accordance with the manufacturer’s instructions. H. Do not overfill cylinders. No more than 80% volume liquid charge.
- I. Do not exceed the maximum working pressure of the cylinder, even temporarily. J. When the cylinders have been filled correctly and the process is completed, make sure that the cylinders and the equipment are removed from the site promptly and all isolation valves on the equipment are closed off.
- K. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been decommissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovers cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designed for the recovered refrigerant and labeled for that refrigerant, i.e. special cylinders for the recovery of refrigerant. Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that is it in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant leak. Consult the manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note shall be arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained form a system, it shall be carried out safely
INSTALLATION INSTRUCTIONS
REQUIRED TOOLS
- Medium sized Phillips screwdriver
- Tape measure or ruler
- Knife or scissors
- Saw (in the event that the window sliders need to be cut to size)
ACCESSORIES
- Air outlet adapter
- Exhaust hose
- Window slider adapter
- 8 bolts
- Window slider A and B
- Window slider C and D
- Foam seal A and B (adhesive)
- Foam seal C (non-adhesive)
- Remote control and batteries
ASSEMBLING THE WINDOW KIT
- Screw the air outlet adapter and the window slider adapter onto either end of the exhaust hose.
- Attach the air outlet adapter to the back of the unit by placing it over the air exhaust and then pushing in the direction of the arrow to lock into place.
- Measure the window opening where the window kit will be installed. Assemble as many sliders as needed to fit the window. If the length of the window requires all three sliders, use two bolts to fasten the sliders at the correct length. If the window opening is less than the minimum length of a single slider, use the slider that has the hole in it and cut it to the correct length. Make sure not to cut the end that has the hole as this is needed to attach the exhaust hose adapter.
INSTALLING THE WINDOW KIT
The window kit can be used in either a hung window or a sliding window. The images at the right are for a hung window but the steps for a sliding window are the same.
-
Cut the adhesive foam seals A and B to the correct length for the window. Attach them to the window sash and frame as shown.
-
Insert the assembled window slider kit into the window opening and close the window on it.
-
Cut the non-adhesive foam seal C to match the width of the window. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room.
-
Extend the exhaust hose and attach the window slider adapter to the hole in the window slider. In tricky installations, it may be easier to attach the adapter to the slider before placing the kit in the window.
Important : Do not over extend or bend the hose as this will impede air flow.
IMPORTANT WARNING
Do not leave this air conditioner unattended in a space where people or animals who cannot react to a malfunction are located. A malfunction such as the exhaust hose becoming dislocated, can cause extreme overheating or death in an enclosed, unattended space.
OPERATING INSTRUCTIONS
FEATURES
- Control panel
- Louver
- Remote control receiver
- Handle (both sides)
- Casters
- Air intake
- Air exhaust
- Continuous drain
- Air intake
- Condenser drain
- Power cord
- Used to secure the power cord for storage. Wrap the power cord and plug the end of the cord here to secure.
LOCATION
- Place the air conditioner on a smooth, level floor that is strong enough to support 110 lbs (50 kg).
- Make sure the air conditioner is level to minimize noise and vibration.
- The air conditioner must be installed near a grounded receptacle and the drain outlet on the rear must be accessible.
- Do not cover air inlets or outlets or the remote control receiver.
- The air conditioner requires 18 inches (45 cm) of space on all sides for proper ventilation.
- Do not over extend or bend the hose as this will impede air flow.
CONTROL PANEL
- Timer indicator
- Wireless connection indicator
- Timer button
- High fan indicator
- Low fan indicator
- Auto mode indicator
- Fan button
- Display panel
- Temperature control buttons
- Cool mode indicator
- Fan mode indicator
- Dry mode indicator
- Mode button
- Sleep mode indicator
- Power button
OPERATING MODE CHART
Press the mode button repeatedly to choose the desired mode.
MODE | DESCRIPTION | EXHAUST HOSE? | DRAIN HOSE? |
---|---|---|---|
Cool |
- Use the temperature control buttons to set the temperature.
- Use the fan button to set the fan speed.
- Temperature range: 18 – 32°C (64 – 90°F).
| Yes| No
Fan|
- Press the fan button to set the fan speed.
| Optional| No
Smart|
- The appliance will choose whether to run cool or fan mode automatically based on the ambient temperature.
- Press the fan button to set the fan speed.
- The appliance will run in fan mode when the ambient temperature is below 23°C (73°F) and in cool mode when the ambient temperature is above 23°C (73°F).
| Mandatory in cool mode.
Optional in fan mode.
| No
Dry|
- The fan speed will be set to auto.
- Water should be drained from the continuous drain using a hose to a floor drain for optimal dehumidification.
- Not using a continuous drain hose and allowing the water to accumulate into the condenser drain reservoir is possible, but could result in re-introducing moisture to the room, and frequent emptying of the reservoir. This can be lessened by using the drain hose from the condenser drain into a floor drain.
| Optional| Using the drain hose with the continuous drain is recommended.
Condenser drain, if necessary.
TIMER
The timer function can be used to turn the appliance on or off after a period of time to conserve energy.
To set the timer to turn the appliance off:
- While the appliance is running, press the timer button. The time display will flash.
- Press the up and down buttons to choose the number of hours before the appliance will turn off.
- Wait 5 seconds to confirm the setting. The timer icon will illuminate.
To set the timer to turn the appliance on:
- Turn the appliance on and choose the desired mode and settings. Turn the appliance off.
- While the appliance is turned off, press the timer button. The time display will flash.
- Press the up and down buttons to choose the number of hours before the appliance will turn on.
- Wait 5 seconds to confirm the setting. The timer icon will illuminate.
Notes: Turning the appliance on or off at any time or adjusting the timer setting to 0 hours will cancel the timer settings.
TURBO
The turbo setting will run the air conditioner at maximum settings to cool the room as quickly as possible. Press the turbo button and the turbo symbol will flash 10 times on the display. The fan speed and temperature cannot be adjusted.
LOUVER
The louver can be adjusted to direct the flow of air. Press the swing button on the remote control to turn the louver on. It will move up and down. Press the louver button again when the louver reaches the desired angle.
CHILD LOCK
Activate the child lock by pressing the temperature control buttons on the remote control at the same time for 3 seconds. The buttons on the remote control cannot be used while the child lock is active. To deactivate the child lock, press and hold the temperature control buttons at the same time for 3 seconds.
SLEEP
The sleep function can be used to conserve energy during sleeping hours. The
sleep function can only be used during cool mode.
When selected, the set temperature will increase by 1 degree per hour for 2
hours. The air conditioner will hold the new set temperature for 6 hours and
then will return to normal operation.
The sleep function can only be activated with the remote control and can be
canceled at any time by pressing the sleep button.
FOLLOW ME
The follow me feature can only be activated from the remote control.
The remote control has a thermostat inside of it. Keep the remote control with
you and the air conditioner will automatically adjust the set temperature
based on the ambient temperature at your location. This feature is available
in cool mode and can be used within 7 meters (23 feet).
To activate follow me, press the turbo button and then press the temperature
control buttons until the follow me icon appears on the display and then press
the turbo button to confirm the selection.
The remote control display will show the actual ambient temperature at its
location. The remote control will send a signal to the air conditioner every
20 minutes to update the set temperature. If the air conditioner does not
receive a signal from the remote control during any 25 minute period, the
follow me feature will deactivate.
To deactivate follow me, press the turbo button and then press the temperature
control buttons until the follow me icon flashes on the display and then press
the turbo button to confirm the selection.
REMOTE CONTROL
- Power button
- Turbo button
- Temperature control buttons
- Timer button
- Mode button
- Swing button
- Sleep button
- Fan button
- °C/°F button
Note: The remote control will function within a range of 7 meters (23 feet) of the appliance.
REMOTE DISPLAY
The digital display on the remote control will show a number of symbols.
REPLACING THE REMOTE BATTERIES
This air conditioner comes with two AAA batteries. Place the batteries in the remote control before use.
- Slide the back cover from the remote downward to expose the battery compartment.
- Insert the batteries, ensure to match the (+) and (-) symbols on the ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
Notes:
- The air conditioner will not respond if curtains, doors or other materials block the signal from the remote control to the unit.
- Prevent any liquid from contact with the remote control. Do not expose the remote control to direct sunlight or heat.
- If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
- Do not mix old and new batteries or batteries of different types.
- Do not leave the batteries in the remote control if it is not going to be used for more than 2 months.
IMPORTANT
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
REMOTE CONTROL REGULATIONS
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not approved by the party responsible for FCC compliance could void the user’s authority to operate the equipment. This appliance complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This device complies with Canadian CAN ICES-003 (B) / NMB-003 (B)
WIRELESS CONNECTION
This air conditioner can be controlled with a wireless application on your wireless device. You will require Android version 5.0 or higher or IOS version 10.0 or higher.
To download the wireless app, either scan the QR code below or download the SmartLife-SmartHome app from either the Google Play Store or the IOS App Store.
You will need to enable permissions for storage, location, camera, Wi-Fi and Bluetooth for this app to work correctly.
Activate the App
The first time you open the wireless app, it will ask for an activation code. Either scan the QR code below to activate the app or enter the code Danby.
s/logo/DANBY
Register A New Account
- Tap “register” if you have never signed in before.
- Read the privacy policy and then tap “Agree”. The text of the privacy policy may vary by location.
- Tap the arrow to choose your country, enter your email address and then tap “Get Verification Code”.
- You will receive a verification code in your email. Enter it into the verification code field.
- Choose a password that is between 6 – 20 characters long and includes both letters and numbers.
Log In
- Tap “Log in with Existing Account”.
- Enter your email and password.
- Tap “Log in”.
Forgotten Password
- If you forget the password for the wireless app, tap “Forgot Password” on the log in page.
- Enter your email account and then tap “Get Verification Code”.
- Enter the verification code from your email.
- Set a new password and tap “Done”.
Basic Voice Commands
Use the greeting for your device, either “Alexa” or “Hi Google” and then use the following commands. In the example below, the air conditioner has been named “bedroom”. You can just say “air conditioner” if you have not given the unit a name.
Command | Description |
---|---|
Turn on bedroom | Will turn the air conditioner on at the most recently used |
settings
Turn off bedroom| Will turn the air conditioner off
Set bedroom temperature to XX degrees| Will set the air conditioner to the
chosen temperature
Increase bedroom temperature| Will increase the set temperature by 1 degree
Decrease bedroom temperature| Will decrease the set temperature by 1 degree
Add A Device – CF (Quick Connection) Mode
-
Power on the appliance that you wish to connect.
-
Hold the fan button and the minus sign on the control panel at the same time to activate the wireless connection. The display will show “CF” to show the wireless is searching for a connection.
-
Click the plus sign in the top right corner of the app and then tap “Add Device”.
-
Tap the logo of the type of appliance you are trying to connect.
-
Input the wifi password.
-
Click the arrows in the top right corner of the app and select CF mode.
-
The codes in the app will indicate the status of the connection.
-
“PP” means “searching for router”
-
“SA” means “connecting to the router”
-
“AP” means “connected to the server”
If the wireless fails to connect, reset the connection using one of the below methods. -
Press the fan button on the control panel 6 times within 4 seconds.
-
Hold the power button on the control panel for 5 seconds.
-
Hold the mode button on the control panel for 3 seconds.
-
Wait 10 seconds for the control panel to flash “CF” or “AP” 5 times before trying to connect again.
-
Add A Device – AP (Access Point) Mode
The appliance will default to CF mode. If you have difficulty connecting to CF mode, try AP mode instead. To change to AP mode, press the fan button 6 times within 4 seconds, wait 10 seconds for the display to show “AP” and the proceed with the connection.
-
Hold the fan button and the minus sign on the control panel at the same time to activate the wireless connection. The display will show “AP” to show the wireless is searching for a connection.
-
Click the plus sign in the top right corner of the app and then tap “Add Device”.
-
Tap the logo of the type of appliance you are trying to connect.
-
Input the wifi password.
-
Click the arrows in the top right corner of the app and select AP mode.
-
The codes in the app will indicate the status of the connection.
-
“PP” means “searching for router”
-
“SA” means “connecting to the router”
-
“AP” means “connected to the server”
If the wireless fails to connect, reset the connection using one of the below methods. -
Press the fan button on the control panel 6 times within 4 seconds.
-
Hold the power button on the control panel for 5 seconds.
-
Hold the mode button on the control panel for 3 seconds.
-
Wait 10 seconds for the control panel to flash “CF” or “AP” 5 times before trying to connect again.
-
WATER DRAINAGE
There are two ways to drain water:
Condenser Drain
When the internal condenser pan is full of condensed water, the appliance will stop operating and the display will show error code “Ft”. The air conditioning or dehumidifying action will stop but the fan may continue to operate
- Ensure that the appliance is turned off and unplugged from the power source before draining the water.
- Carefully move the appliance to a location where the water can be drained such as a floor drain, a sink or similar. Keep the appliance upright at all times so water does not leak.
- Remove the drain plug and allow the water to completely drain.
- Replace the bottom drain plug, pressing firmly to ensure a tight fit and no leaks.
- The “Ft” error symbol will disappear and the appliance will resume regular function once power is restored.
Continuous Drain
During dry mode, we recommend using the continuous drain option so that the appliance will automatically drain collected water.
- Ensure that the appliance is turned off and unplugged from the power source before attaching the drain hose.
- Remove the drain plug and attach the provided drain hose or a standard garden hose to the continuous drain. If using a garden hose, ensure that it is not more than 6 feet long so that water does not collect inside the hose.
- Ensure that there are no kinks or bends in the drain hose as this can stop water from draining.
- Direct the end of the drain hose toward a basement floor drain, a sink or similar.
CARE & MAINTENANCE
CLEANING
- Unplug the appliance before cleaning or servicing.
- Clean the cabinet with a lukewarm damp cloth and dish soap. Dry the cabinet with a lint-free dry cloth.
- Do not use gasoline, paint thinner or other chemicals to clean the appliance.
- Do not wash the appliance directly under a tap or using a hose. It may cause electrical damage.
AIR FILTER
The filters in this appliance should be cleaned every two weeks to ensure efficient performance.
In households with animals, the air filters may need to be cleaned more often and the external grills may need to be wiped to prevent blocked air flow.
LONG-TERM STORAGE
- Drain all water from the appliance.
- Run the appliance on fan mode for half a day in a warm room to dry the inside of the appliance and prevent mold formation.
- Turn off the appliance and unplug it, wrap the cord and bundle it with tape.
- Remove the battery from the remote control.
- Clean the air filters and reinstall them.
- Store the appliance in a cool, dark place. Prolonged exposure to direct sunlight or extreme heat can shorten the lifespan of the appliance.
DISPOSAL
This appliance should not be treated as regular household waste. Check for local regulatory compliance regarding the approved and safe disposal of this appliance.
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
ERROR CODES
PF – sensor failure – unplug the appliance for 5 minutes to reset the internal sensors; if the error code persists after plugging the appliance back in, please contact consumers care for servicing information.
Ft – condenser pan is full – drain excess water
TROUBLESHOOTING AND FREQUENTLY ASKED QUESTIONS
PROBLEM| POSSIBLE CAUSE AND SOLUTION
Appliance will not operate|
- Plug is not fully inserted into the wall outlet; ensure the unit is plugged in.
- Blown fuse or circuit breaker; check the circuit breaker panel.
Insufficient cooling|
- Air filters are dirty; ensure the air filter is clean.
- Blocked air flow; ensure that the air inlets are not blocked.
- Appliance size is too small for application; consider a larger appliance.
Noise|
- The ground is not level; ensure the appliance is level
- Air filters are dirty; ensure the air filter is clean
- Gurgling sounds are normal; this is the refrigerant moving inside the appliance
Odors|
- Usually caused by the formation of mold or mildew on internal wet surfaces.
- Ensure the filter is clean.
- Run the air conditioner on fan mode to remove any internal moisture.
Can I leave my the window kit in place through the winter?| No, this is
not recommended.
What is the electrical rating?| This information can be found on the
rating plate located on the side of the unit.
Can I use an extension cord?| No, an extension cord may not be used.
When should I use the exhaust hose?| The exhaust hose should be used in
cool mode. It is optional in dry and fan mode.
Can I extend the length of the exhaust hose?| No, the exhaust hose
cannot be extended. Instead use an additional fan to blow the cool air to
other locations.
When should I use the drain hose?| The drain hose should be used with
the continuous drain during dry mode.
WIRELESS APP TROUBLESHOOTING
PROBLEM| POSSIBLE CAUSE AND SOLUTION
Appliance can’t be configured successfully|
- Ensure that permissions are enabled for storage, location, camera, Wi-Fi and Bluetooth.
- Check the mobile connected WLAN router SSID and password is correct.
- Check whether there are additional settings of the WLAN router such as:
- Firewall by router itself or by PC
- MAC address filtering
- Hidden SSID
- DHCP server
- Reboot the WLAN router, mobile device and the appliance and try connecting again.
- Before rebooting, check that no one else has already connected to the appliance.
Mobile device cannot control the appliance|
- In the case of a power failure, the wireless will lose permissions to control the appliance for 3 minutes.
- If the wireless does not automatically reconnect after 3 minutes, you may need to connect the wireless again.
Mobile device cannot find the appliance|
- Check that the appliance is turned on and has power.
- Check that the wireless router is turned on and has power.
- Check that the internet connection is working.
- Check that the mobile device is charged and can connect to the internet.
- The appliance may have disappeared from the device list; try to read it again.
LIMITED “CARRY IN” WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non- transferable.
TERMS OF WARRANTY
Plastic parts are warranted for thirty (30) days from the date of purchase, with no extensions provided.
First 24 months: During the first twenty four (24) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s option, at no charge to the original purchaser.
To obtain service: Contact the dealer where the unit was purchased, or contact the nearest authorized Danby service depot, where service must be performed by a qualified service technician. If service is performed on the unit by anyone other than an authorized service depot, all obligations of Danby under this warranty shall be void.
It is the responsibility of the purchaser to transport the appliance to the nearest authorized service depot.
Transportation charges to and from the service location are not protected by this warranty and are the responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or statute is hereby expressly excluded. Save as herein provided, Danby shall not be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or property caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
- Power failure
- Damage in transit or when moving the appliance.
- Improper power supply such as low voltage, defective house wiring or inadequate fuses.
- Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions (ie. extremely high or low room temperature).
- Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
- Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
- Service calls resulting in customer education.
- Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled).
Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present the proof of purchase to our authorized service depot.
Warranty Service
In-home
Customer Support
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: 519-837-0920 FAX:
519-837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone : 419-425-8627 FAX:
419-425-8629
*Trademark of Danby Products
References
- Danby® the Appliance Specialists | Canada
- Danby® the Appliance Specialists | Canada
- Customer Support | Danby Canada
- Product Registration | Danby Canada
- Apps | Danby Canada
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>