00 200778 Network Cable Tester

JACK PIN DESIGNATIONS Patch

1

2

| white/orange orange
---|---
3| white/green
4

5

| blue white/blue
6| green
7

8

| white/brown brown

Operating instruction

Package contents

  • Network Cable Tester
  • Remote unit
  • These operating instructions

Safety instructions

  • This product is intended for private, non-commercial use only.
  • Protect the product from dirt, moisture and overheating and use it in dry rooms only.
  • Only use the article under moderate climatic conditions.
  • Do not attempt to service or repair the product yourself. Leave any and all service work to qualified experts.
  • Do not open the device or continue to operate it if it becomes damaged.
  • Do not operate the product outside the power limits given in the specifications.
  • Do not modify the device in any way. Doing so voids the warranty.
  • As with all electrical products, this device should be kept out of the reach of children.
  • Use the product only for the intended purpose.
  • Protect the product from dirt, moisture and overheating and use it in dry rooms only.
  • The product is intended only for use inside buildings.
  • Do not use the product in the immediate vicinity of heaters, other heat sources or in direct sunlight.
  • Do not use the product in a damp environment and avoid splashing water.
  • Do not use the product in areas in which electronic products are not permitted.
  • Do not drop the product and do not expose it to any major shocks.
  • Dispose of packaging material immediately in accordance with the locally applicable regulations.

Warning – Batteries

  • When inserting batteries, note the correct polarity (+ and – markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
  • Only use batteries (or rechargeable batteries) that match the specified type.
  • Before you insert the batteries, clean the battery contacts and the polarity contacts.
  • Do not allow children to change batteries without supervision.
  • Do not mix old and new batteries, or batteries of different types or from different manufacturers.
  • Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).
  • Do not short-circuit batteries.
  • Do not charge batteries.
  • Do not burn batteries.
  • Keep batteries out of the reach of children.
  • Never open, damage or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
  • Remove spent batteries from the product and dispose of them without delay.
  •  Avoid storing, charging and using in extreme temperatures and at extremely low atmospheric pressures (such as at high altitudes).

Commissioning and operation – Multi-port

3.1 Inserting / changing the batteries

  • Remove the battery compartment cover on the back.
  • Remove the flat battery if necessary and replace it with a new 9V block battery, observing the correct polarity.
  • Close the battery compartment again. Your test device is now ready for use.

3.2 Preparation
Warning

  • Do not connect any live cables to the tester.
  • Ensure that all screw and crimp connections on the cables to be tested have been carried out carefully. Modular plugs that are not fully crimped can lead to damage to the tester.

Testing 6p6c/RJ12 and 6p4c/RJ11 cables:
Connect one end of the cable to the 6p6c socket on the network tester (1) and the other to the 6p6c socket on the remote unit (1).
Testing 8p8c/RJ45 cables: Connect one end of the cable to the 8p8c socket on the network cable tester (2) and the other to the 8p8c socket on the remote unit (2).
3.3. Testing and evaluation

  • Move the slider switch (A) to the “ON” position for normal testing speed.

  • Move the slider switch (A) to the “S” position for slow testing speed.

  • If the cables are connected correctly, the LEDs (B) 1-8 (or 1-6) both on the network cable tester and the remote unit will light up in a numerical sequence.

  • If the cables and plug shieldings are present and correctly connected, the LED “G” (C ) will also light up once the 1-8 (or 1-6) sequence has been completed.

  • If one or more cables are interrupted, the corresponding LEDs on the network cable tester and remote unit will not light up.

  • If fewer than two cables are connected correctly, all LEDs will remain dark.

  • If two or more wires are mixed up, the LEDs on the remote unit will light up in a backward, non-numerical sequence. The LEDs on the network cable tester light up
    in the normal, numerical sequence.

  • If there is a short circuit of up to two wires, the LEDs that are assigned to the shortcircuited wires will not light up.

  • If three or more wires are short-circuited, all LEDs will remain dark.

  • To test installed sockets or patch panels, short network cables (not supplied) can be used to connect the sockets to the sockets on the network cable tester or remote unit.

  • The remote unit is detachable so that cable connections between different rooms can also be tested (Graphic B).

Warranty Disclaimer

Hama GmbH & Co KG assumes no liability and provides no warranty for damage resulting from improper installation/mounting, improper use of the product or from
failure to observe the operating instructions and/or safety notes.

HamaGmbH&CoKG
86652Monheim/Germany
Service&Support
www.hama.com
+499091502-0

00200778/ 10.22

All listed brands are trademarks of the corresponding companies. Errors omission excepted, and subject to technical changes. Our general terms of delivery payment is applied.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals