Product Information

Product Name LED Light Panel
Model Numbers UGR16-30W-60SQ, UGR16-30W-120/30
Voltage Input AC200-240V/50/60Hz
Power Consumption 30W
Applications Hotel, meeting room, factory or office, residence or public

facilities, commercial use, schools, hospitals, and other
environments.
Usage| Indoor use only

Product Usage Instructions

Recessed Installation

  1. Take off the ceiling plaster tablet.
  2. Connect the wire.
  3. Fix the panel light into the ceiling screens.
  4. After securing the panel light, you can connect the electric current to use.

Surface Mount Installation

  1. Fix the panel frame directly, no screws are needed.
  2. Fix the panel light on the ceiling frame.

Suspended Installation

  1. Take off the cassette and install the screw cassette.
  2. Fix the ceiling frame into the ceiling or wall.
  3. Lock the Line controller into the cassette.
  4. Adjust the length of the iron line well and connect the power supply, then you can power.

Module Replacement

  1. Turn off the power and take off the LED panel light.
  2. Replace the LED module and fix it with a clasp.
  3. Fix the panel light on the ceiling frame.

Safety Instructions

This installation must be carried out by an electrician. Please read these instructions carefully before installation. Leave a copy for the user/maintenance engineer for future reference.

This is a mains-powered product. Before installation, maintenance, or cleaning, please ensure the power supply is isolated.

Maintenance Instructions

  1. Please ensure the fitting has cooled down prior to performing maintenance on this product.
  2. If the product is not damaged in transport, it is supplied ready to use.
  3. Clean using a dry cloth. Do not use detergent or water.

Additional Notes

  • Please confirm that this product has not been damaged during transit before using it.
  • Keep packing material and small accessories far away from children.
  • Avoid direct eye contact with the LED light-emitting area.
  • Keep products and packaging away from open fire or high-temperature goods.
  • The fixture must not be modified, as it will void the warranty and can make the product dangerous.
  • The recommended clearance from the rear heat sink to any flammable materials is 0.2m. Under no circumstance should any insulation or similar be laid onto the fitting.

Recessed Installation

  1. Take off Ceiling plaster tablet.
  2. Connect the Wire.
  3. Fix the panel Light on into the ceiling screens.
  4. After steady the panel light, you can connect the electric current to use.POWER-LITE-UGR16-30W-60SQ-LED-Light-Panel-FIG-4

Safety Instructions

  • This installation must be carried out by an electrician. Please read these instructions carefully before installation. Leave a copy for the user/maintenance engineer for future reference.
  • This is a mains-powered product. Before installation, maintenance, or cleaning please ensure the power supply is isolated.

Maintenance

  • a. Please ensure the fitting has cooled down prior to performing maintenance on this product.
  • b. If the product is not damaged in transport, it is supplied ready to use.
  • c. Clean using a dry cloth. No detergent or water is to be used.

Notes

  • Voltage input: AC200-240V/50/60Hz, using the newest high-efficiency constant current driver. Anti-electromagnetic interference, no mercury, no lead. Before using, please confirm that this product has not been damaged during transit.
  • Please keep packing material and small accessories far away from children. Avoid the eyes sighting the LED light-emitting area directly.
  • Please keep products and packaging away from open fire or high-temperature goods.
  • The fixture must not be modified. The modification will void the warranty and can make the product dangerous.
  • Please note the recommended clearance from the rear heat sink to any flammable materials is 0.2m. Under no circumstance should any insulation or similar be laid onto the fitting.

Applications

  • Hotel, meeting room, factory or office, residence or public facilities, commercial use, school, hospital, and other environments.
  • LED panel light for indoor use only.

Module Replacement

  1. Turn off the power, and take off the LED panel light.POWER-LITE-UGR16-30W-60SQ-LED-Light-Panel-FIG-5
  2. Replace the LED module. Fix it with a clasp.
  3. Fix the panel light on the ceiling frame.

Surface Mount Installation

  1. Fix the panel frame directly, no screws are needed.
  2. Fix the ceiling frame into the ceiling or wall.
  3. Fix the panel light on the ceiling frame.
  4. After steady the panel light, you can connect the electric current to use.

Suspended Installation

  1. Take off the cassette and install the screw cassette.
  2. Fix the cassette onto the ceiling.
  3. Lock the Line controller into the cassette.
  4. Adjust the length of the iron line well and connect the power supply, then you can power.

Documents / Resources

| POWER-LITE UGR16-30W-60SQ LED Light Panel [pdf] Installation Guide
UGR16-30W-60SQ, UGR16-30W-60SQ LED Light Panel, LED Light Panel, Light Panel, Panel
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals