fronius 6.0 Plus Primo Gen24 Plus Single Phase Hybrid User Guide
- June 13, 2024
- Fronius
Table of Contents
fronius 6.0 Plus Primo Gen24 Plus Single Phase
Technical Data (WLAN)
Frequency band: channel 1-14(2412-2462 MHz)
Radio-frequency power: <100 mW (<20 dBm)
English Hereby, Fronius International GmbH declares that the radio equipment type Fronius Primo GEN24 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.fronius.com
WARNING! Operating the equipment incorrectly or poor workmanship can cause serious injury or damage. The inverter may only be installed and commissioned by trained personnel acting in accordance with the technical regulations. Before working with the device, ensure that you have read and understood all the documents provided (both hard copies enclosed with the product and documents provided online). When solar modules are exposed to light, they supply voltage to the inverter. This document does not describe all of the possible system configurations.
FRONIUS PRIMO GEN24 3.0 – 6.0 / 3.0 – 6.0 PLUS
Dimensions (height x width x depth)| 530 x 474 x 165 mm
Max. short-circuit current (ISC PV = ISC max)| 36 A (MPPT1) / 19 A (MPPT2)
Battery voltage range| 150 – 455 V
FRONIUS PRIMO GEN24 8.0 – 10.0 / 8.0 – 10.0 PLUS
Dimensions (height x width x depth)| 595 x 529 x 180 mm
Max. short-circuit current (ISC PV = ISC max)| 41.25 A (MPPT1) / 36 A (MPPT2)
Battery voltage range| 150 – 455 V
Only suitable battery configurations for Fronius GEN24 inverters permitted.
To connect a battery to the Fronius Primo GEN24 inverter see:
QUICK START GUIDE (Components)
Fronius Primo GEN24 Plus
Fronius Smart Meter 63A-3 / TS 65A-3
BYD Battery-Box Premium HVS / HVM and LG RESU FLEX
MOUNTING
AC
DC
Close & Commission
CUSTOMER SUPPORT
Detailed, country-specific warranty terms are available on: www.fronius.com/solar/warranty