Structure

BURG WACHTER 610 Scan and Lock - Structure A Lock body and shackle
B USB type-C port
C Emergency lock
D Fingerprint sensor
E Indicator light

Features

Easy Operation:
Up to 10 fingerprints can be programmed (1x administrator, 9x user)
Waterproof & Dustproof:
IP65, protected from rain and dust.
Unlocking in 1 second:
Quick-recognition technology, identify your fingerprint quickly.
Low Power Consumption:
After being fully charged, up to 1,800-2,000x locking and unlocking possible.

Ways to unlock

Note:
Pull the shackle after release via the fingerprint or open it upwards using the key.

Operating instructions: Fingerprint sensor

BURG WACHTER 610 Scan and Lock - fig 1

Opening with fingerprint

Action Beeps LED Explanation
To activate: press the shackle once Blue flashing Note: At the

factory and in delivery
condition, the lock can be opened with
any fingerprint. The lock is individualised
when it is set-up by the administrator.
To open: place your finger on the sensor for around 1 sec.| Two beeps| Blue shining

Set administrator account

Action

| | Beeps| LED|

Explanation

---|---|---|---|---
To activate, press the shackle down once| | | Blue flashing|
Press fingerprint sensor around 3s| | Two beeps, 3 sec. pause, one beep| Blue shining|
Input administrator fingerprint, 10 times| | One beep| Blue flashing, lx|

Input finger again

| Neli piiksu Four beeps| Vilgub punaselt Red flashing| Finger not registered, input again
| | Pikk piiks Long beep| Poleb siniselt Blue shining| Programming finished
| Uks piiks One beep| Poleb punaselt Red shining| Restart programming with 1st step

Set user account

Action Beeps LED Explanation
To activate: press the shackle down once Blue flashing
Press fingerprint sensor around 3s Two beeps Blue/red flashing
Place administrator fingerprint One beep Vilgub siniselt, lx Blue

flashing, lx
| Four beeps| Red flashing| Place administrator finger again
Place user fingerprint, 10 times| | One beep| Blueflashing, lx| Place finger again
| Four beeps| Red flashing| Finger not registered, input again
| | Long beep| Blue shining| Programming completed
| One beep| Red shining| Restart programming with 1st step

Reset

Action Beeps LED Explanation
To activate: press the shackle down once Blue flashing
Place administrator fingerprint, 8 sec. Two beeps Blue/red flashing,
pause, red flashing
Place administrator fingerprint Long beep Red shining Lukk lahtestatud
Four beeps Red flashing Finger not registered, place again

Charging
If the green light flashes after you unlock it, it means the battery is low. Please charge it in time to avoid locking unsuccessful by fingerprint when the battery runs out. In order to charge, use the included Type-C USB-cable.

Action Beeps LED Explanation

BURG WACHTER 610 Scan and Lock - fig 7| | Green flashing| Note: If the battery is already completely discharged, the lock can still be opened with the enclosed key.
Charging with enclosed USB-cable| | Green shining

Troubleshooting

Symptoms Reasons Solution
The light is off when you press the sensor Battery discharged Charging the

fingerprint padlock
In standby status| Please press the shackle
Any finger can unlock| The lock is in factory setting, any finger can be be used to open be used to open it.| Set administrator account
Cannot unlock| Sensor does not identify finger| Sensor surface or fingerprint dirty; please clean

Warnings
Please note the following information:

  1. The output voltage of the adapter must be 5 V when charging.
  2. Do not insert any extraneous objects into the lock or the USB port.

Warranty

BURG-WÄCHTER products comply with the technical standards at the time of production and adhere to our own quality standards. The guarantee only covers defects which can be proved to have resulted from production or material defects at the time of purchase. The warranty ends after two years, further claims are excluded. Defects and damage caused by e.g. transport, incorrect operation, improper use, wear etc. are excluded from the warranty. A short description of any defects identified must be made in writing and the device returned to the place it was purchased, together with the original packaging. After the device has been tested, and within a appropriate period of time, the guarantor will decide whether or not to repair or exchange the item.
For returns, all undamaged device parts must furthermore be in the factory setting due to your right of revocation. Failure to comply with this will invalidate the warranty.

Disposal of the device

Dear customer, please help us to avoid unnecessary waste. Should you intend to dispose of this device at any time, please remember that many components of this device contain valuable materials that can be recycled.
Please be aware that electrical and electronic equipment and batteries marked in this way must not be disposed of with household waste but collected separately.
Please obtain information on the collecting points for electrical waste from the responsible authority of your city/ municipality.
BURG-WÄCHTER KG hereby declares that this device complies with the Directives 2014/30/EU, (EMC) and 2011/65/EU (RoHS).
The complete text of the EU Declaration of Conformity is available at the following Internet address: www.burg.biz

Eesti keeles
Scan &Lock 610 / 53
Printing and typesetting errors as well as technical changes reserved.
BURG-WÄCHTER KG
Altenhofer Weg 15
58300 Wetter
Germany
www.burg.biz
www.burg.biz
SWI/MLO Scan & Lock 610 / 53 ET -EN 040523

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BURG WACHTER User Manuals

Related Manuals