Product Information
The APV-16 series is a 16W single-output switching power supply. It is designed for various applications that require a stable and reliable power source. The power supply has multiple models with different output voltages and currents to suit different requirements.
Key Specifications:
- Model: APV-16-5, APV-16-12, APV-16-15, APV-16-24
- Output Voltage: 5V, 12V, 15V, 24V
- Rated Current: 2.6A, 1.25A, 1A
- Rated Power: 13W, 15W, 15W
- Efficiency: 76%, 80%, 81%, 83%
- Input Voltage Range: 90 ~ 264VAC
- Operating Temperature: -30°C ~ +70°C
- Safety Standards: UL8750, CSA C22.2 No.250.0-08, BIS IS15885 (except for 15V), EAC TP TC 004, IP42, BS EN/EN 62368-1 approved
Product Usage Instructions
- Ensure that the input voltage is within the range of 90 ~ 264VAC.
- Connect the AC/N (Blue) and AC/L (Brown) wires to the appropriate AC power source.
- Connect the +V (Red) and -V (Black) wires to the device requiring power.
- Make sure the power supply is placed in a well-ventilated area with sufficient clearance for heat dissipation.
- Monitor the ambient temperature and ensure it does not exceed the specified operating temperature range of -30°C to +70°C.
- Do not overload the power supply beyond the rated current and power limits.
- In case of an over-voltage or overload condition, the power supply has built-in protection mechanisms to prevent damage. Once the fault condition is removed, the power supply will automatically recover.
- Refer to the provided derating curve to understand the power supply’s performance at different ambient temperatures and load percentages.
- For detailed safety guidelines and other specifications, please refer to the user manual available at https://www.meanwell.com/Upload/PDF/LED_EN.pdf.
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Features
- Constant voltage design
- Universal AC input/Full range
- Protections: Short circuit/Over load/Over voltage
- Fully isolated plastic case
- Cooling by free air convection
- Small and compact size
- Class II power unit, no FG
- Class 2 power unit
- Pass LPS
- IP42 design
- Suitable for LED-related fixtures or appliances (such as LED Decoration or Advertisement devices
- 100% full load burn-in test
- Low cost, high reliability (Note.7)
- 2 years warranty
SPECIFICATION
MODEL | APV-16-5 | APV-16-12 | APV-16-15 | APV-16-24 |
---|
OUTPUT
| DC VOLTAGE| 5V| 12V| 15V| 24V
RATED CURRENT| 2.6A| 1.25A| 1A| 0.67A
CURRENT RANGE| 0 ~ 2.6A| 0 ~ 1.25A| 0 ~ 1A| 0 ~ 0.67A
RATED POWER| 13W| 15W| 15W| 16.08W
RIPPLE & NOISE (max.) **Note.2| 100mVp-p| 120mVp-p| 120mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.3| ±5.0%
LINE REGULATION| ±1.0%
LOAD REGULATION| ±2.0%
SETUP, RISE TIME| Note.6| 1500ms, 30ms / 230VAC
1500ms,30ms / 115VAC at full load
HOLD UP TIME (Typ.)**| 20ms/230VAC 12ms/115VAC at full load
INPUT
| VOLTAGE RANGE| Note.4| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 76%| 80%| 81%| 83%
AC CURRENT| 0.3A/230VAC 0.5A/115VAC
INRUSH CURRENT(Typ.)| COLD START 50A(twidth=250μs measured at 50% Ipeak)
at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 13 units (circuit breaker of
type B) / 22 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION
| OVERLOAD| Above 105% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
OVERVOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16V| 17.5 ~ 21V| 27.6 ~ 32.4V
Protection type: Shut off o/p voltage, clamping by Zener diode
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃(Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, and Z axes
SAFETY & EMC
| SAFETY STANDARDS Note.8| UL8750,CSA C22.2 No.250.0-08, BIS IS15885(except for 15V),EAC TP TC 004,IP42 ,
BS EN/EN 62368-1 Approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS
EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN55035,BS
EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), EAC TP TC 020
OTHERS
| MTBF| 7265.5K hrs min. Telcordia SR-332 (Bellcore) ;
1128.9K hrs min.| MIL-HDBK-217F (25℃)|
DIMENSION| 774029mm (LWH)
PACKING| 0.1Kg; 120pcs/14Kg/1.06CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation, and load regulation.
- Derating may be needed under low input voltage. Please check the static characteristics for more details. Please connect the L line to the positive pole and the N line to the negative pole under DC input.
- The power supply is considered a component that will be operated in combination with the final equipment. Since EMC’s performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation.
- The length of set-up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time.
- This product is not intended for LED lighting luminaire applications in the EU. (In the EU the LPF/NPF/XLG series are recommended.)
- The model certified for CCC(GB19510.14, GB19510.1, GB17743, and GB17625.1) is an optional model. Please contact MEAN WELL for details.
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000(6500ft)
- Products sourced from the Americas regions may not have the ENEC/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
- For any application note and IP waterproof function installation caution, please refer to our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx.
Mechanical Specification
Block Diagram
Derating Curve
Static Characteristics
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>