Oceanic OCEAVCDB110 Tower Fan Instruction Manual

June 13, 2024
Oceanic

Oceanic OCEAVCDB110 Tower Fan

Oceanic-OCEAVCDB110-Tower-Fan-PRODUCT

Safety Instructions

Thanks sincerely for choosing our tower fan. For better use, please read this manual thoroughly before using and keep it for future use.

WARNING:

  • To reduce the risk of fire, electrical shock, or injury to a person: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • The product is for household use only.
  • Connect the appliance to AC supply of the voltage specified on the rating plate.
  • Never leave the fan unattended while it is in use. Always turn the product to the OFF position and unplug it from the electrical outlet when not in use.
  • Extreme caution is necessary when any fan is used by or near children, invalids or elderly person and whenever the fan is left operating and unattended.
  • Do not run cord under carpeting and do not cover cord with throw rugs. Arrange the cord away from traffic areas and where it will not be tripped over.
  • Do not operate the fan with a damaged cord or plug, or after the fan malfunctions, has been dropped, or damaged in any manner.
  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person to avoid a hazard.
  • Use the fan in a well-ventilated area. While using, distance of no less than 20 cm should be kept away from wall or corner to ensure the air intakes or exhaust openings should not be blocked unexpectedly.
  • Do not insert or allow fingers or any other objects into the grilles or louvres to avoid mechanical danger when in use. Do not block air intake or exhaust openings in any manner.
  • Use the fan on flat, dry floor only.

Brief introduction

This tower fan is with multiple functions: 3 speed, 3 mode, 85 degrees oscillation, 12H timer, and remote control.

Specification

MODEL NO. RATED POWER CLASS REFERENCE NO.
NDTFT14RH 220-240V~,50-60Hz 50W II OCEAVCDB110 / OCEAVCDW110

Structure

Oceanic-OCEAVCDB110-Tower-Fan-FIG- \(1\)

1 Head
2 Display
3 Remote control
4 Air outlet
5 Air inlet
6 Base A
7 Base B

Installing

  1. Take out the two bases from the packaging carton and connect together. Fig 1
  2. Fix fan body with the base by 4pcs screws. Fig 2

Function

Display

1 Temperature indicator
2 Timer indicator
3 Oscillation indicator
4 Low speed
5 Middle speed
6 High speed
7 Normal mode
8 Natural mode
9 Sleep mode
10 Temperature and time indicator

Control panel and remote controlOceanic-OCEAVCDB110-Tower-Fan-FIG-
\(4\)

1 2 3 4 5

On/Off

button

| ****

Oscillation button

| ****

Mode button

| ****

Timer button

| ****

Speed button

ON/OFF

Press this ON/OFF button to turn the fan ON/OFF. Press it once, the fan will start operation and shows the default wind level 2. Press the button again to stop the fan.

Mode
The model has three modes: Normal/ Natural/ Sleeping, when you turn on the fan, the default mode is Normal, the LED screen will indicate , if you want to change the mode, press , and choose the mode you want.

  • Normal wind mode:
    The Normal light indicator will be switched ON when selected this mode.

  • Natural wind mode:
    The Natural light indicator  will be ON when selected this mode. The fan will run from selected Max wind level to Min wind level mode as cycle mode.

  • Sleep wind mode:
    The Sleep light indicator will be ON when selected this mode. The fan will run from selected Max wind level to Min wind level mode as cycle mode. This mode will reduce 1 wind level in every single half an hour. Keep Wind Speed Level 1 until it turns off.

Oscillation
Press button , the fan will oscillate from left to right automatically

Timer
Press button , then press button again to set the duration of time (from 0h to 12h Max, with each pressure you increase the time of 1h). To cancel the set timer, press button , then press button again to set as 00 Hr.

Wind Speed
Press to choose the wind speed range from 1 to 3.

Remote control
Before using the remote control, pull the plastic card at the bottom of the remote control out. Please make sure the remote control alignment the fan when you use the remote control.Oceanic-OCEAVCDB110-Tower-Fan-FIG-
\(13\)

This product is supplied with disposable batteries

WARNING: KEEP BATTERIES OUT OF REACH OF CHILDREN.
Choking hazard. Do not swallow. Harmful if swallowed. Swallowing can lead to chemical bums, perforation of soft tissue, and death. Severe burns can occur within 2 hours of ingestion. Seek medical attention immediately. Warning! : Batteries should not be exposed to excessive heat such as sun, fire or similar origin. Do not short-circuit the battery. Do not recharge the battery. Do not disassemble the battery. Remove the battery in case of prolonged non-use. Do not throw the battery into the fire. Used batteries are recyclable: do not throw them in the trash! Take them back to your store and they will be recycled!

TECHNICAL DATA

Information requirements for comfort fans.

Information to identify the model(s) to which the information relates to [fill in as necessary]:
Description| Symbol| Value| Unit
Maximum fan flow rate| F| 22,62| m³/min
Fan power input| P| 43,70| W
Service value| Sv| 0,52| (m³/min)/W
Standby power consumption| PSB| 0,67| W
Fan sound power level| LWA| 57,64| dB(A)
Maximum air velocity| C| 2,66| meters/sec
Measurement standard for service value| EN IEC 60879: 2019


Contact details for obtaining more information

| OCEANIC

120-126 Quai de Bacalan CS 11584

33000 Bordeaux

**Attention

Oceanic-OCEAVCDB110-Tower-Fan-FIG-
\(14\) Oceanic-OCEAVCDB110-Tower-Fan-FIG-
\(15\)**

Maintenance and Storage

  1. Always remove the plug from the socket outlet and allow the fan to stop before cleaning it.

  2. Clean the external surfaces of the fan with a soft damp (not dripping wet cloth)
    WARNING:
    Do not immerse the fan in water.
    Do not use any cleaning chemicals such as detergents and abrasives. Do not allow the interior to get wet as this could create a hazard.

  3. When the unit is not in use, make sure that it is unplugged from the wall socket. To store the fan, you may pack it in the original carton and store it in a cool and dry place.

  4. In case of malfunction or doubt, do not try to repair the fan yourself, it may result in a fire hazard or electric shock.

After sale service

This appliance has a warranty of 2 years from the date of purchase, considering the following notes:

  • The guarantee is only valid showing the invoice or purchase ticket.
  • Damage caused during transportation, negligence, incorrect installation or installation, and external influences such as: atmosphere or electric rays, floods, humidity, etc. are not covered by the guarantee.
  • This warranty will finish when it is discovered that it has been subjected to repairs, alterations or interventions by any person not authorized.

DISPOSAL
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling

OCEANIC
120-126 Quai de Bacalan CS 11584 33000 Bordeaux

IMPORT BY:
A.M.C. 123, QUAI JULES GUESDE 94400 VITRY SUR SEINE France

www.oceanic.eu

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Oceanic User Manuals

Related Manuals