VICKS VUL525E Mini Cool Mist Ultrasonic Humidifier Instruction Manual

June 6, 2024
Vicks

VUL525E Mini Cool Mist Ultrasonic Humidifier
Instruction Manual

VICKS VUL525E Mini Cool Mist Ultrasonic Humidifier -
overviewVICKS VUL525E Mini Cool
Mist Ultrasonic Humidifier - 1

IMPORTANT SAFETY INSTRUCTIONS
Read through all the instructions before starting to use the appliance. Keep this manual in a safe place for future reference.
These instructions are also available on our website.
Please visit www.helenoftroy.com/emea-en
WARNING:
Do not add essential oils to the tank.

  • Unplug the appliance during filling and cleaning.

  • Read all instructions before using this humidifier.

  • Always place this humidifier on a firm, flat and level surface. This humidifier may not work properly on an uneven surface.

  • Place this humidifier in an area where it is not accessible to children.

  • Do not place the humidifier near any heat sources such as stoves, radiators, and heaters.

  • Do not use the humidifier outdoors.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.

  • The appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of this appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  • To disconnect the humidifier, first, turn the controls to the OFF position, then grip the plug and pull it from the wall outlet. Never pull by the cord.

  • Never tilt or attempt to move the humidifier while it is operating or filled with water.
    UNPLUG the humidifier before moving.

  • This humidifier requires regular cleaning.
    Refer to the CLEANING instructions provided.
    Never clean the humidifier in any manner other than as instructed in this manual.

  • Do not direct moisture flow directly at individuals, walls, or furniture.

  • When a humidifier is used in a closed room or small rooms, check periodically for proper ventilation, as excessive humidity can cause condensation stains on walls.

  • Turn the humidifier OFF if you notice moisture on the inside of your windows. For proper humidity, reading using a hygrometer, which is available in many hardware and department stores, or by ordering one from the manufacturer.

  • Do not place the product directly on wood furniture or other surfaces that could be damaged by water or liquids. The manufacturer will not accept responsibility for property damage caused by spillage or leaking.

  • Micro-organisms that may be present in the water or in the environment where the appliance is used or stored, can grow in the water reservoir and be blown in the air causing very serious health risks when the water is not renewed and the tank is not cleaned properly every 3 days.

  • Be aware that high humidity levels may encourage the growth of biological organisms in the environment.

  • Do not permit the area around the humidifier to become damp or wet. If dampness occurs, turn the output of the humidifier down. If the humidifier output volume cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.

  • Never leave water in the reservoir when the appliance is not in use.

  • Empty and clean the humidifier before storage. Clean the humidifier before the next use.

  • This appliance must only be used with the power supply unit provided with the appliance.

  • The appliance is only to be used with the recommended vaporizing medium. The use of other substances may give rise to a toxic or fire risk.

COMPONENTS (See page 1)

  1. Carrying handle
  2. 180° mist nozzle
  3. Water tank
  4. Tank cap
  5. Base
  6. Power switch and intensity control
  7. Pilot light
  8. Cleaning indicator
  9. VapoPad heater
  10. Power cord

FIRST TIME OF USE

Before using the unit for the first time, you should note the following points:

  • Remove all packing material from the unit
  • It is recommended that you disinfect your humidifier prior to first use. See cleaning instructions.
  • Select a firm, level location at least 15 cm from any walls for proper airflow.
  • Place the humidifier on a water-resistant surface.

OPERATING INSTRUCTIONS

FILLING (See appendix A on page 2)
Remove the Water Tank by grasping the handle and pulling it straight up. Set aside (1).

  • Turn the Water Tank upside down so that the Tank Cap is facing up; unlock the Tank Cap by turning it counterclockwise and set it aside (2).

  • Fill the Water Tank with clean, cool, tap water (3).

  • Replace the Tank Cap by turning clockwise (4). Turn the Water Tank upright and check the Tank Cap for leaks. If any water drips from the Tank Cap, remove it and re- lighten it. The use of very cold water may temporarily reduce the mist output. Never fill the humidifier with hot or warm water as this could cause damage and void your warranty.
    NOTE: When carrying the filled Water Tank, please use the handle and place your other hand under the tank for additional support.

  • Position the Water Tank in the humidifier and push it into place. Some water will empty into the Base (5).

  • Once the filled tank has been positioned, do not attempt to move the humidifier. If it has to be moved, unplug the humidifier and remove the Water Tank first.
    NOTE: Every time you switch the device on or every 3 days when the sound and light go on, press the indicator to acknowledge that the water tank has been cleaned. The 3 days reminder to clean the device will then reset.

POWER (See appendix B on page 2)
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET
HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.

  • With the power switch in the OFF position, plug the filled humidifier into an outlet (1).

  • Turn the Power Switch clockwise to the on position. The pilot light will illuminate (2).

  • The Cleaning indicator and sound will go on when you switch the device on. Press the cleaning button to acknowledge that the water tank is cleaned (3), the sound and light to clean will turn off.

  • Set your desired output by turning the knob clockwise. To operate on HIGH, turn the dial to the end (4).

  • When a comfortable humidity level is reached turn Power Switch to a lower setting. A comfortable humidity level is between 40-and 60%. To monitor your humidity level use a hygrometer such as the Vicks V70 2-in-1 Hygrometer & Thermometer (5).

  • The unit will shut off when it is out of water.
    Cleaning affects the time it takes for the auto shut-off to work. When dirty – the time delay for auto shut-off takes longer When clean – works appropriately.

  • Turn the humidifier off before removing and refilling the Water Tank. When the Water Tank is empty and the water level in the base gets too low, the fan and nebulizer turn off.

VAPOPAD HEATER DIRECTIONS FOR USE
(see appendix C on page 2)

  • Turn off and unplug your humidifier (1).
  • Open the VapoPad door located below the power switch by pushing the button (2).
  • Insert VapoPad all the way in with angled end facing towards the product in the slot (3). Be careful not to touch the VapoPad with your hands (4). If your hands do come in contact with the pad, wash them thoroughly, as essential oils can be irritant to the skin.
  • Close the door, plug the unit back in and turn it on (5).

Note: As long as your humidifier is on, the VapoPad heater will also be activated. This area can be warm to the touch.
NEVER add essential oils or VapoPads directly into the water tank as this can result in degradation of the material.

WARNING:
Pad may present a choking hazard. Keep out of reach of children and pets. H317 May cause an allergic skin reaction. P102 Keep out of reach of children. P302

  • P352 IF ON SKIN: wash with plenty of soap and water. P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.
    Ingredients: eucalyptus oil, menthol, glycol, cedar leaf oil & others 1 menthol VapoPad included.
    Do not use for babies less than 36 months old, for more than 16 hours in a 24 hour period, and/or not more + than 36m* than 2 pads in a 24 hour period.

CARE AND CLEANING INSTRUCTIONS EVERY 3 DAYS CLEANING
(See appendix D on page 3)

  • Each time the device is switched on or every 3 days, the cleaning feature will illuminate and beep every 5 seconds to remind the user of the required cleaning. Press the leaning indicator to acknowledge that the water tank is cleaned, the reminder to clean the device will reset. The light and the beep sound will turn off. If you do not acknowledge your cleaning, the light will stay on and the beep will sound every 5 seconds until the cleaning indicator is pressed, whilst the unit will operate normally.
  • Disconnect from the mains before cleaning (1).
  • Every third day, lift the Water Tank from the Base (2) and empty all water from the reservoir (3). Before refilling, clean it with fresh tap water or cleaning agents if required  (4). Remove any scale, deposits, or film that has formed on the sides of the tank or on interior surfaces (5), and wipe all surfaces dry (6).
  • DO NOT leave water in the Water Tank or reservoir when the unit is not in use as it may result in the buildup of mineral deposits and bacteria that can inhibit the output efficiency of the humidifier. Please note that if water remains in the Water Tank for more than a day or two, bacteria growth is possible.
  • To fill and power ON, refer to Operating Instructions (see Appendix A and B on page 2).

WEEKLY SCALE REMOVAL
(See appendix E on page 3)

  • Disconnect from the mains before cleaning (1).

  • Lift the Water Tank from the Base (2) and empty all water from the reservoir (3). Remove the Tank Cap and drain any water from the Water Tank (4). Wipe it clean with a soft, damp cloth. Rinse the Water Tank with lukewarm water after each use.

  • Add 0.5 liter of undiluted distilled white vinegar to Water Tank. Replace Tank Cap and swish vinegar solution around in Tank. Place Tank on Base. The vinegar solution will drain into Water Reservoir and loosen mineral buildup (scale) on Nebulizer and Float as they soak in the solution. It will also loosen the scale on the bottom of the Water Tank (5).

  • Soak for 15-20 minutes (6).

  • After soaking, unlock the Tank Cap and pour the solution out into the sink.
    Pour the solution from Water Reservoir out into the sink (7).

  • Wipe Nebulizer and Float with a soft cloth to remove loosened mineral deposits (8).

  • Rinse Water Reservoir and Water Tank until the smell of vinegar is gone. Make sure water does not enter the fan opening (vented opening in the back of base) or Power Switch.

  • DO NOT immerse the Base in water. Gently wipe the reservoir with a soft, clean, wet cloth.

  • DO NOT use detergent to clean any water-containing parts of the humidifier. Detergents and the film they leave behind can affect the output of the humidifier. DO NOT use abrasive cleaners or brushes.

  • To fill and power ON, refer to Operating Instructions (see Appendix A and B on page 2).

WEEKLY DISINFECTING
(See appendix F on page 3)

  • Disconnect from the mains before cleaning (1).

  • Lift the Water Tank from the Base (2) and empty all water from the reservoir (3). Remove the Tank Cap and drain any water from the Water Tank (4).

  • If accessories are installed, remove accessories and set them aside.
    DO NOT clean accessories. This will damage the accessories.

  • Thoroughly clean humidifier every week using a solution of bleach and water (5ml of bleach in 1.8 liters of water). Fill the water tank partially with this solution (5).

  • Let stand twenty (20) minutes (6), shaking vigorously every few minutes. Drain and rinse with clean water until the bleach smell is gone (7).

  • Wipe the reservoir with a soft cloth dampened in the solution. Rinse the area thoroughly before proceeding (8).

  • If mineral deposits are evident around the Nebulizer, clean the surface with a soft, clean cloth and a small amount of undiluted white vinegar. If necessary for the removal of mineral deposits, mix a solution of 50% white vinegar and 50% water and fill the Base with enough solution to cover the Nebulizer. Rinse out the reservoir and wipe clean.
    Do not touch the Nebulizer or the Water Sensor with bare fingers as any fingerprints or residue can reduce mist output. Do not immerse the Base in water.

  • To fill and power ON, refer to Operating Instructions (see Appendix A and B on page 2).

STORAGE

Follow cleaning instructions and dry products thoroughly.
DISPOSAL
This appliance complies with EU legislation 2012/19/EU on the end of life recycling. Products showing the ‘Crossed Through’ wheeled bin symbol on either the rating label, gift box or instructions must be recycled separately from household waste at the end of their useful life. Please DO NOT dispose of appliances in normal household waste. Your local appliance retailer may operate a ‘take-back’ scheme when you are ready to purchase a replacement product, alternatively contact your local government authority for further help and advice on where to take your appliance for recycling.

GUARANTEE

Please read all instructions before attempting to use this device. Please retain the receipt as proof of and date of purchase. The receipt must be presented when making any claim within the relevant guarantee period. Any claim under the guarantee will not be valid without proof of purchase.
Your device is guaranteed for two years (2 Years) from the date of purchase.
This guarantee covers defects in materials or workmanship that occur under normal use; defective devices meeting these criteria will be replaced free of charge. The guarantee DOES NOT cover defects or damage resulting from abuse or failure to follow the user instructions. The guarantee becomes void if the device is opened, tampered with or used with other parts or accessories, or if repairs are undertaken by unauthorised persons.
Accessories and consumables are excluded from any warranty. For support requests, please visit www.helenoftroy.com/emea- en/support/ or find service contact information at the end of this owner’s manual.
This Guarantee is applicable to Europe, Russia, the Middle East, and Africa only.
UK Only: This does not affect your consumer statutory rights.
The LOT and SN of your device are printed on the rating label on the packaging of the product.

As a condition of sale, the purchaser assumes responsibility for the proper use and care of this appliance in accordance with these printed instructions. The purchaser or user must judge himself or herself when to use the appliance and the length of use.
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR HUMIDIFIER PLEASE SEE WARRANTY FOR INSTRUCTIONS. PLEASE DO NOT ATTEMPT TO REPAIR THE HUMIDIFIER YOURSELF. DOING SO WILL VOID THE WARRANTY AND COULD CAUSE DAMAGE OR PERSONAL INJURY.
This product carries the CE mark and is manufactured in conformity with the Electromagnetic Directive 2014/30/EU, the Low Voltage Directive 2014/35/EU, the RoHS Directive 2011/65/ EU, and the Energy Using Products Directive 2009/125/EC. Technical specifications are subject to change.
VUL525E
220-240V ~ 50-60Hz
25W

CONDITION OF SALE

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The power Switch is set to “On” and Power Light is off Unit not plugged in

Plug unit in.
No power at the outlet| Check circuits, and fuses, try a different outlet.
Little or no mist is produced| No water in the tank| Fill Water Tank.
Unit is not level| Place on a level surface.
Mineral deposits on Nebulizer| Clean Nebulizer per instructions.
The water Tank was washed with detergent| Rinse thoroughly with clean water. Wipe dry.
Water level is too low| Add water to Water Tank.
Nebulizer or fan not functioning| See Guarantee.
Condensation forms around humidifiers or windows| Mist intensity is set too high for room size or preexisting humidity level| Reduce output level or shut off the humidifier.
Mineral residue (“White Dust”) Accumulation| Hard water used| Use distilled water.
The Cleaning indicator and sound are always on| It is normal for the sound and light to activate every time the unit is powered to indicate that the humidifier must be regularly cleaned| Following the guidance in the owner manual, please undertake thorough cleaning every 3 days, press the cleaning button to clear the notifications.

PERFORMANCE SPECIFICATION
Tank capacity (liter) : 1.8L
Duration – Full tank at minimum setting (hour): 24h Ideal for Rooms (square meter): 15m2
Clean the water tank every three days

Support contact numbers

Austria
☎ +43 (0)1 360 277 1225
Bahrain
☎ +973 1725 1988
Belgium/Luxemburg
☎ +32 (0) 2 620 01 01
Bosnia
☎ +387 (33) 902 911
Bulgaria
☎ +359 2 492 87 05
Croatia
☎ +385 (01) 3444 856
Cyprus
☎ +357 22575016
Cyprus Northern region
☎ +90 (0) 392 22 72 367
Czech Republic
☎ +420 (0) 2 25 43 97 69
Denmark
☎ +45 35 15 80 40
Finland
☎ +358 (0)9 81 71 00 14

Certain trademarks used under license from
The Procter & Gamble Company or its affiliates.
© 2021, All rights reserved.

Kaz Europe Sàrl
A Helen of Troy Company
Place Chauderon 18
CH-1003 Lausanne – Switzerland
www.helenoftroy.com/emea-en/

Made and Printed in China
P/N: A005184R2
22JUN21

Helen of Troy
Creative Department Artwork Specifications
Brand: Vicks
Category: Humidifier
Model: VUL525E
Artwork Part #: A005184R2
Die Line Part #: N/A
Subject: Owner’s Manual
Region: EMEA
Flat Size: MM: W296 x H210
Folded Size: MM: W148 x H210
Scale: 1/1
Material: 40# gloss or matte text
Minimum 80# gloss or matte text (cover)
Page Count: 88
Revision: 1
Date: 22JUN21
Release Date: 15JUL21
Re-release Date:
Re-release Date:
Colors:

Dielines (Do not print) Spot Colors

Cyan
0%| Magenta
0%| Yellow
0%| Black
100%| PMS
XXXX| PMS
XXXX
| | | | |

Special Instructions:
Quality Requirement of Artwork and Quality
Clarification Process of Artwork Printing:
Meet Eng-QS-06&02

References