KEPLERX K15HVC18W2H Multi Position Air Handler Datasheet
- May 15, 2024
- KEPLERX
Table of Contents
15SEER2 series
Multi-Position, Multi-speed
Air Handler 1½ to 5 Tons
Product Features
- Internal factory-installed Piston as expansion valve for cooling and heat pump applications.
- PSC & ECM motor through 1.5-5ton, provide selections of air flow to meet desired applications.
- Painted Galvanized steel cabinet with thermal insulator cover all inside panels to reduce heat transfer and prevent condensed water accumulation.
- “A” Shape coil, constructed with copper tubing and enhanced anti-corrosion aluminum fins.
- Coil mounting track for quick repositioning.
- Optimized for use with R-410A refrigerant.
- Horizontal or vertical configuration capabilities.
- 22”depth for easier attic access.
- 3/4” NPT primary and secondary drains.
- Foil-faced insulation covers the internal casing to reduce cabinet condensation.
- Glue-less cabinet insulation retention.
- Tool-less filter access.
- Field Installed 5 kW – 20 kW electric heater kits available.
- AHRI certified; ETL listed.
Nomenclature
Product Specifications
| K15HVC18W2H| K15HVC24W2H| K15HVC30W2H| K15HVC36W2H|
K15HVC42W2H| K15HVC48W2H| Kl5HVC60W2H
---|---|---|---|---|---|---|---
Nominal Ratings| | | | | | |
Cooling (Btu/h)| 17,500| 22,000| 28,000| 33,000| 40,000| 45,000| 55,500
Blower| | | | | | |
Diameter| 11| 11| 11| 11| | 11| 11
Width| 11| 11| 11| 11| 11| 11| 11
Coil Connections| | | | | | |
Liquid| ⅜”| ⅜”| ⅜”| ⅜”| ⅜”| ⅜”| ⅜”
Suction| ¾”| ¾”| ¾”| ¾”| ¾”| ⅞ “| ⅞ “
Coil Drain Connect (NPT)| ¾”| ¾”| ¾”| ¾”| ¾”| ¾”| ¾”
Electrical Data| | | | | | |
Voltage| 208/230| 208/230| 208/230| 208/230| 208/230| 208/230| 208/230
Minimum Circuit Ampacity| 1.8A| 2.3A| 2.8A| 4.0A| 4.5A| 5.2A| 5.4A
Max. Overcurrent Device (Amos)| 3.0A| 3.0A| 3.0A| 6.0A| 6.0A| 6.0A| 6.0A
Min/Max Volts| 187/253| 187/253| 187/253| 187/253| 187/253| 187/253| 187/253
Blower Motor| | | | | | |
Full Load Amps (FLA)| 1.1A| 1.7A| 2.1A| 2.8A| 3.3A| 3.6A| 3.9A
Horsepower (HP)| 1/4HP| 2/7HP| 1/2HP| 1/2HP| 3/4HP| 3/4 HP| 3/4HP
Ship Weight (Lbs.)| 137| 143| 141| 141| 146| 185| 185
Dimensions
DEMENSIONAL DATA
MODEL SIZE | Dimensions inch |
---|
UNIT HEIGHT
“H” IN| UNIT WIDTH
“W” IN.| UNIT LENGHT
“D” IN| SUPPLYDUCT
“A” IN| LIQUID LINE/
VAPOR LINE IN
K15HVC18W2H| 45-3/4″| 19-5/8″| 22″| 17-7/8″| 3/8″ / 3/4″
K15HVC24W2H| 45-3/4″| 19-5/8″| 22″| 17-7/8″| 3/8″ / 3/4″
K15HVC30W2H| 45-3/4″| 19-5/8″| 22″| 17-7/8″| 3/8″ / 3/4″
K15HVC36W2H| 45-3/4″| 19-5/8″| 22″| 17-7/8″| 3/8″ / 3/4″
K15HVC42W2H| 45-3/4″| 19-5/8″| 22″| 17-7/8″| 3/8″ / 3/4″
K15HVC48W2H| 53-1/8″| 22″| 24-1/2″| 19-1/2″| 3/8″ / 7/8″
K15HVC60W2H| 53-1/8″| 22″| 24-1/2″| 19-1/2″| 3/8″ / 7/8″
WIRING DIAGRAM
- To avoid the electrical shock, please connect the air conditioner with the ground lug. The main power plug in the air conditioner has been joined with the ground wiring, please don’t change it freely.
- The power socket is used as the air conditioner specially.
- Don’t pull the power wiring hard.
- When connecting the air conditioner with the ground, observe the local codes.
- If necessary, use the power fuse or the circuit, breaker or the corresponding scale amper®:
Wiring connection for A/C Systems
Wiring connection for H/P Systems
Applicable for K15HVC18W2H, K15HVC24W2H
LINEAR ANNOTATION | NOTES | DIAL SWITCH DESCRIPTION |
---|
_____ FACTORY DEFAULT
– – – – – – FIELD INSTALLED
– – – – – – FACTORY OPTION
Please refer to the actual wiring diagram| 1. Grounded and all wiring to
conform to I.E.C.
2. Replacement wire must be the same gauge and insulation type as original
wire.
3. The units should connect the stated-cross-section earth wire and keep it
grounding unfailingly.
4. Electric Heater is optional.| SW1-1| AC FAN
The rest of the DIP switches are reserved
K15HVC30W2H, K15HVC36W2H, K15HVC42W2H, K15HVC48W2H, K15HVC60W2H
| DIAL SWITCH DESCRIPTION
---|---
LINEAR ANNOTATION| NOTES| SW1-1| LOW
_____ FACTORY DEFAULT
– – – – – – FIELD INSTALLED
– – – – – – FACTORY OPTION
Please refer to the actual wiring diagram| 1. Grounded and all wiring to
conform to I.E.C.
2. Replacement wire must be the same gauge and insulation type as original
wire.
3. The units should connect the stated-cross-section earth wire and keep it
grounding unfailingly.
4. Electric Heater is optional.| SW1-2| MEDIUM LOW
SW1-3| MEDIUM
SW2-1| MEDIUM HIGH
SW2-2| HIGH
DIAL SWITCH| FAN SPEED MODE| MODEL| | DIAL SWITCH| FAN
SPEED MODE| MODEL
---|---|---|---|---|---|---
| MEDIUM| 30K, 42K| | MEDIUM HIGH| 36K, 48K, 60K
COMPANY WITH
QUALITY SYSTEM
CERTIFIED BY DNV GL
= ISO 9001=
COMPANY WITH
ENVIRONMENTAL SYSTEM
CERTIFIED BY DNV GL
= ISO 14001=
- Complete warranty details available from your local dealer or at www.eqkhvac.com. To receive the 10-Year Compressor and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.
http://www.keplerx.net
15SEER2 series
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>