CAUTION:.

  1. BEFORE INSTALLING THE LIGHT FIXTURES, PLEASE READ THE INSTALLATION INSTRUCTION CAREFULLY.
  2. DISCONNECT POWER AT THE CIRCUIT BREAKER BEFORE INSTALLATION OR SERVICING.
  3. DO NOT INSTALL THE TRACK IN DAMP OR WET LOCATIONS.
  4. THIS TRACK IS IP20, INDOOR USE ONLY.
  5. ALL ELECTRICAL CONNECTIONS SHOULD BE DONE BY A QUALIFIED ELECTRICIAN.

ACCESSORIES REQUIRED

KENDAL MODEL MSA16

WHICH INCLUDES

INSTALLATION

STEP 1 MARK CENTER LINE WHERE TRACK IS TO BE INSTALLED

  • NOTE: 24-VOLT POWER COMING FROM THE CEILING MUST ALIGN WITH THE 24-VOLT INPUT CONNECTOR ON THE TRACK. THE INPUT CONNECTOR IS LOCATED 5 1/2 INCHES FROM END OF THE TRACKKENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-2
  • STEP 2 INSTALL SURFACE MOUNT KITS ALONG CENTER LINE BUT  DO NOT OVER TIGHTEN. DO NOT INSTALL SURFACE MOUNT KITS WITHIN 8″ OF THE ENDS OF THE TRACK AS THIS MAY INTERFERE WITH THE POWERACCESSAREAAND WHERE TRACK JOINERS MAY BE USED.KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-3
  • STEP 3 USING PROVIDED ALLEN WRENCH, LOOSEN SET SCREWS ON POWER LOCATION ACCESS COVERS. SLIDE THE COVERS OPEN TO ACCESS THE 24 VOLT POWER CONNECTION.
  • STEP 4 CONNECT 24VOLT POWER FROM THE DRIVER TO THE 24 VOLT ON THE TRACK, RED WIRE TO POSITIVE AND BLACK WIRE TO NEGATIVE. ATTACH THE WIRE RESTRAINT TO THE POWER CORD. KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-5
  • STEP 5 SLIDE COVERS BACK OVER ACCESS HOLE AND TIGHTEN SET SCREWS
  • STEP 6 SECURE TRACK TO CEILING BY TURNING THE SURFACE MOUNT KITS AND LOCKING THE TRACK IN PLACE (KITS CAN BE USED SO THE TABS CAN BE ON EITHER SIDE OF THE TRACK EXAMPLE ALL ONE SIDE OR ALTERNATING FROM ONE SIDE TO THE OTHER) KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-7
  • STEP 7 INSTALL THE ELEMENTSKENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-8

ACCESSORIES REQUIRED

  • KENDAL MODEL MSA02 TRACK CONNECTOR
  • KENDAL MODEL MSA01 POWER PLATE
  • KENDAL MODEL MSA16 SURFACE MOUNT KITS AS NEEDED

INSTALLATION

  • STEP 1 MARK CENTER LINE WHERE TRACK IS TO BE INSTALLEDKENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-12
  • STEP 2 INSTALL SURFACE MOUNT KITS ALONG THE CENTER LINE BUT DO NOT OVER-TIGHTEN. DO NOT INSTALL SURFACE MOUNT KITS WITHIN 8″ OF THE ENDS OF THE TRACK AS THIS MAY INTERFERE WITH THE POWER ACCESS WHERE TRACK JOINERS MAY BE USED.KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-13
  • STEP 3 REMOVE END CAPS WHERE TRACK IS BEING JOINEDKENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-14
  • STEP 4 REMOVE THE DECORATIVE PLATE FROM THE TRACK BEING ADDEDKENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-15
  • STEP 5 REMOVE THE MAGNET FROM THE TRACK BEING ADDEDKENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-16
  • STEP 6 INSTALL A POWER PLATE MSA01KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-17
  • STEP 7 INSTALL A TRACK CONNECTOR MSA02 TO THE END OF THE TRACK BY INSERTING IT INTO THE SLOT ON THE BACK OF THE TRACK. SLIDE THE CONNECTOR IN ALL THE WAY SO THE PINS ARE VISIBLE WHEN JOINING THE TRACKS TOGETHER.
  • STEP 8 WHILE CAREFULLY LINING UP THE PIN CONNECTORS WITH PIN CONNECTOR HOLES ON THE OTHER TRACK JOIN THE TRACKS TOGETHER. KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-19

ATTENTION:

  • WHEN JOINING TRACKS OR ACCESSORIES UTILISE PIN CONNECTORS. MAKE SURE PINS ARE HORIZONTAL AND LINED UP WITH PIN CONNECTOR HOLES.
  • YOU MAY NEED TO GENTLY PUSH UP OR DOWN ON THE PINS SO THEY LINE UP CORRECTLY. FAILING TO DO THIS MAY RESULT IN PINS MISSING THE PIN CONNECTOR HOLES AND LOSS OF THE 24-VOLT CONNECTION.KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-20
  • STEP 9 SLIDE THE MSA02 TRACK CONNECTOR BACK SO IT IS HALF WAY ONTO EACH TRACK AND TIGHTEN SET SCREWS
  • STEP 10 USING PROVIDED ALLEN WRENCH, LOOSEN SET SCREWS ON POWER LOCATION ACCESS COVERS. SLIDE THE COVERS OPEN TO ACCESS THE 24 VOLT POWER CONNECTION.
  • STEP 11 CONNECT 24VOLT POWER FROM THE DRIVER TO THE 24 VOLT ON THE TRACK, RED WIRE TO POSITIVE AND BLACK WIRE TO NEGATIVE. ATTACH THE WIRE RESTRAINT TO THE POWER CORD. KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-23
  • STEP 12 SLIDE COVERS BACK.OVER ACCESS HOLE AND TIGHTEN SET SCREWS
  • STEP 1 3 SECURE TRACK TO CEILING BY TURNING THE SURFACE MOUNT KITS LOCKING TRACK IN PLACE (KITS CAN BE USED SO THE TABS CAN BE ON EITHER SIDE OF THE TRACK EXAMPLE ALL ONE SIDE OR ALTERNATING FROM ONE SIDE TO THE OTHER) KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-25
  • STEP 14 INSTALL THE ELEMENTSKENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-26
  • NOTE: AFTER EACH TRACK CONNECTION A CONTINUITY TEST SHOULD BE DONE TO ENSURE PROPER ELECTRICAL CONNECTIONS WERE MADE.

INSTALLATION INSTRUCTIONS

CAUTION:

  1. BEFORE INSTALLING THE LIGHT FIXTURES, PLEASE READ THE INSTALLATION INSTRUCTIONS CAREFULLY.
  2. DISCONNECT POWER AT THE CIRCUIT BREAKER BEFORE INSTALLATION OR SERVICING.
  3. DO NOT INSTALL THE TRACK IN DAMP OR WET LOCATIONS.
  4. THIS TRACK IS IP20, INDOOR USE ONLY.
  5. ALL ELECTRICAL CONNECTIONS SHOULD BE DONE BY A QUALIFIED ELECTRICIAN.

NOTE:

  1. TRACK SECTIONS SHOULD BE JOINED TOGETHER ON THE FLOOR BEFORE INSTALLING INTO THE CEILING.
    WHEN INSTALLING LONGEf’l Tf{ACI( HUNS UTILZING MULTIPLE 96 WATT SECTIONS, YOU MUST ENSURE THE ELECTRICAL CONNECTION BETWEEN EACH SECTION IS TERMINATED. A NEW CONNECTION FROM THE DRIVER SHOULD BE MADE AT THE START OF EACH ADDITIONAL 96-WATT SECTION WITHOUT THE USE: OF MSA22. 4-PIN CONNECTORS OJ{ RECESSED CABLE CON HECTORS.

TRACK PROFILE

  • MS1S 1000mm (39.4″)
  • MS2S 2000mm (78. 7″)
  • MS3S 3000mm (118.1″)

INCLUDED HARDWARE

MS1S (ONE METER TRACK) INCLUDES:

  • STEP 1 MARK CENTER LINE WHERE TRACK IS TO BE INSTALLED
  • STEP 2 REMOVE END CAPS FROM TRACK
  • STEP 3 REMOVE DECORATIVE PLATE
  • STEP 4 REMOVE MAGNET
  • STEP 5 HOLD TRACK UP TO CEILING AND MARK HOLE LOCATION FOR MOUNTING SCREW USING SECOND HOLE IN FROM END OF TRACK
  • STEP 6 SLIDE PCB BOARDS TO END OF TRACK TO EXPOSE MOUNTING HOLE AT OPPOSITE END OF TRACK
  • STEP 7 MARK HOLE LOCATION FOR MOUNTING SCREW USING SECOND HOLE FROM END OF TRACK
  • STEP 8 I NSTALL DRYWALLANCHORS
  • STEP 9 USING PROVIDED ALLEN WRENCH, LOOSEN SET SCREWS ON POWER LOCATION ACCESS COVERS. SLIDE THE COVERS OPEN TO ACCESS THE 24 VOLT POWER CONNECTION.
  • STEP 10 CONNECT24 VOLT POWER FROM THE DRIVER TO THE TRACK, RED WIRE TO POSITIVE AND BLACK WIRE TO NEGATIVE. ATTACH THE WIRE RESTRAINT TO THE POWER CORD. KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-39
  • STEP 11 SLIDE COVERS BACK OVER ACCESS HOLE AND TIGHTEN SET SCREWS
  • STEP 12 ATTACH ONE END OF TRACK TO CEILING
  • STEP 13 SLIDE PCB BOARDS TO END OF TRACK TO EXPOSE MOUNTING HOLE AT OPPOSITE END OF TRACK
  • STEP 14 ATTACH OTHER END OF TRACKTOCEILING
  • STEP 15 RE-INSTALL THE MAGNET
  • STEP 16 RE-INSTALL THE DECORATIVE PLATE
  • STEP 17 RE-INSTALL END CAPS
  • STEP 18 INSTALL THE FIXTURE

ACCESSORIES REQUIRED

  • KENDAL MODEL MSA02 TRACK CONNECTOR
  • KENDAL MODEL MSA01 POWER PLATE’

INSTALLATION

  • STEP 1 MARK CENTER LINE WHERE TRACK IS TO BE INSTALLED
  • STEP 2 REMOVE END CAPS FROM TRACK
  • STEP 3 REMOVE DECORATIVE PLATE
  • STEP 4 REMOVE MAGNET
  • STEP 5 INSTALL TRACK CONNECTOR MSA02 TO THE END OF THE FIRST TRACK BY INSERTING THE TRACK CONNECTOR INTO THE SLOT ON THE BACK OF THE TRACK APPROXIMATELY HALF WAY AND TIGHTEN WITH SET SCREWS (MAKE SURE MOUNTING HOLE IN TRACK LINES UP WITH MOUNTING HOLE IN TRACK CONNECTOR). MARK HOLE LOCATION USING THE SECOND HOLE IN FROM THE END OF THE TRACK. KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-60
  • STEP 6 WHILE HOLDING THE TRACK ON CENTER LINE, SLIDE PCB BOARDS TO THE OTHER END OF THE TRACK TO EXPOSE MOUNTING HOLES AND MARK HOLE LOCATION USING SECOND HOLE IN FROM THE END OF THE TRACK.
  • STEP 7 INSTALL DRYWALL ANCHORS
  • STEP 8 USING PROVIDED ALLEN WRENCH, LOOSEN SET SCREWS ON POWER LOCATION ACCESS COVERS. SLIDE THE COVERS OPEN TO ACCESS THE 24 VOLT POWER CONNECTION.
  • STEP 9 CONNECT 24 VOLT POWER FROM THE DRIVER TO THE TRACK, RED WIRE TO POSITIVE AND BLACK WIRE TO NEGATIVE. ATTACH THE WIRE RESTRAINT TO THE POWER CORD AND SLIDE COVERS OVER ACCESS HOLE. KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-55
  • STEP 10 TIGHTEN SET SCREWS
  • STEP 11 ATTACH ONE END OF THE FIRST TRACK TO CEILING
  • STEP 12 ATTACH OTHER END OF FIRST TRACK TO CEILING USING SECOND HOLE FROM END OF TRACK
  • STEP 13 REMOVE END CAP, DECORATIVE PLATE AND MAGNET FROM TRACK BEING ADDED KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-59
  • STEP 14 SLIDE NEXT TRACK ONTO THE TRACK CONNECTOR SO ITS TIGHT AGAINST THE FIRST TRACK, MARK HOLE LOCATIONKENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-60
  • STEP 15 SLIDE PCB BOARD TO EXPOSE MOUNTING HOLE AT OPPOSITE AND MARK HOLE LOCATION USING SECOND HOLE FROM END OF TRACK
  • STEP 16 INSTALL DRYWALLANCHORS
  • STEP 17 INSTALL A POWER PLATE MSA01 TO THE JOINING END OF THE FIRST TRACK
  • STEP 18 MOUNT THE JOINING END OF THE SECOND TRACK TO CEILING KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-63
  • STEP 19 REPLACE END CAP AT BEGINNING OF FIRST TRACK
  • STEP 20 BY PUSHING ON THE PCB BOARDS FROM THE END OF THE SECOND TRACK, CAREFULLY SLIDE THE PCB BOARDS SO THE PINS ON THE MSA01 POWER PLATE LINE UP AND CONNECT WITH THE PIN CONNECTOR HOLES ON THE SECOND TRACK. KENDAL-LIGHTING-MS3S-WH-Track-Surface-Mount-fig-65

ATTENTION:

  • WHEN JOINING TRACKS OR ACCESSORIES UTILIZING PIN CONNECTORS, MAKE SURE PINS ARE HORIZONTALAND LINE UP WITH PIN CONNECTOR HOLES. YOU MAY NEED TO GENTLY PUSH UP OR DOWN ON THE PINS SO THEY LINE UP CORRECTLY.
  • FAILING TO DO TH IS MAY RESULT IN PINS MISSING THE PIN CONNECTOR HOLES AND LOSS OF THE 24 VOLT CONNECTION.
  • STEP 21 ATTACH OTHER END OF THE SECOND TRACK TO CEILING
  • STEP 22 RE-INSTALL THE MAGNET AND DECORATIVE PLATE
  • STEP 23 INSTALL REMAINING END CAP