BEGA 24115 Ceiling And Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA 24115 Ceiling And Wall Luminaire

Ceiling and wall luminaire

BEGA-24115-Ceiling-And-Wall-Luminaire-FIG-1

Instructions for use

Application
Unshielded ceiling and wall luminaire with high protection class. For a variety of interior and exterior lighting applications.

Product Description
Luminaire made of aluminum alloy, aluminum, and stainless steel BEGA Unidure® coating technology White synthetic diffuser 2 elongated fixing holes Width 7 mm · 350 mm spacing Connection box with 2 cable entries for through-wiring of the mains supply cable ø 5-13 mm, max. 5×2,5@ LED power supply unit 220-240 V 0/50-60 Hz DC 176-264 V DALI-controllable Number of DALI addresses: 1Basic insulation is provided between the mains and control cables BEGA Thermal Control® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Protection class IP 65 Dust-tight and protection against water jets Impact strength IK06 Protection against mechanical impacts < 1 joule

  • Safety mark
  • Conformity mark

Weight: 3.4 kg This product contains light sources of energy efficiency class(es) B

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability fordamage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation

Undo the hexagon socket head screw (wrench size 3 mm) in the luminaire base and remove the covering cap. Fix the luminaire base with enclosed or any other suitable fixing material onto the mounting surface.BEGA-24115-Ceiling-And-
Wall-Luminaire-FIG-4

Use the supplied connection box to make the electrical connection (see illustration). Undo the hexagon socket screws and open the connection box. Run the luminaire power supply cable through the PG 9 cable gland and the power connecting cable through the M25 cable gland and into the connection box. For through-wiring, the factory-fitted dummy plug must be removed. Tighten the cable glands firmly. Make the protective earth connection and the electrical connection. Observe the correct configuration of the connecting cable. Make the mains connection to the brown (L), blue (N) and green-yellow wires ( ). The control cables are connected via the two DALI-labelled wires white-red (wh-rd) and white-black (wh-bl). If these wires are not assigned, the luminaire will work with full light output. Close the connection box. Make sure the gasket is properly located. Note the position of application of the luminaire top “arrow down”. Place the luminaire top onto the luminaire base and tighten the screws evenly.

Cleaning  Maintenance

Clean dirt and debris from the luminaire regularly with a clean, soft, lint- free cloth that is kept damp throughout the cleaning. If possible, please use water for this, adding a little commercial dishwashing detergent. For lacquered surfaces, we recommend the use of BEGA Lacquer Care Set 71 179. Cleaning agents containing solvents and high-pressure cleaners are unsuitable for cleaning and maintenance.

Lamp

  • Module connected wattage 11.1 W
  • Luminaire connected wattage 14.7 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

24 115 K3

  • Module designation 2x LED-0894/830 + LED-0900/830
  • Color temperature 3000 K
  • Color rendering index CRI > 80
  • Module luminous flux 2320 lm
  • Luminaire luminous flux 1847 lm
  • Luminaire luminous efficiency 125,6 lm / W

24 115 K4

  • Module designation 2x LED-0894/840 + LED-0900/840
  • Color temperature 4000 K
  • Color rendering index CRI > 80
  • Module luminous flux 2385 lm
  • Luminaire luminous flux 1899 lm
  • Luminaire luminous efficiency 129,2 lm / W

Please note: Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture.

Replacement Power supply unit/LED module

The designation of the LED module is noted on a label in the luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system. Undo the hexagon socket head screw (wrench size 3) in the luminaire base and remove the covering cap. Loosen the three hexagon socket screws at the cover of the connection compartment and lift off the cover of the connection compartment. Loosen connecting cable at the plug-in terminals. Disassemble the front-end head plate at the terminal side. For this purpose loosen the hexagon head screw (wrench size 4) as far as it will go and remove the head plate from the synthetic cover. Pull out the LED module carrier out of the synthetic diffuser. Replace the power supply unit or LED module. Please follow the installation instructions for the LED module. Insert LED module carrier. Make sure that the module carrier is seated in the guiding bolts of the opposite head plate. Push the head plate firmly onto the synthetic diffuser. Make electrical connections at the plug-in terminals and assemble cover of the connection compartment. Place the luminaire top onto the luminaire base and tighten the screws evenly.

Spares

  • Synthetic cover 15 000 525 B
  • LED power supply unit DEV-0388/700i
  • LED module 3000 K LED-0894/830
  • LED module 4000 K LED-0894/840
  • LED module 3000 K LED-0900/830
  • LED module 4000 K LED-0900/840
  • Gasket Synthetic cover 83 001 761
  • Gasket cover 83 001 830

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals