AENO DI1 Dental Irrigator User Guide
- June 13, 2024
- AENO
Table of Contents
AENO DI1 Dental Irrigator
Product Information
The AENO device is designed for thorough oral care and removal of food remnants from interdental spaces. It has a nozzle outlet and comes with various modes for different cleaning preferences. The device is equipped with an automatic turn-off feature that activates after 2 minutes of use. It is important to follow the maintenance instructions to ensure the proper functioning of the device. For any questions or issues, please contact our online support team at support@aeno.com or visit aeno.com/service-and-warranty.
Product Usage Instructions
- For first-time users, please refer to the user manual for detailed instructions.
- Ensure the device is charged before use.
- Choose the desired mode by pressing the corresponding button (1) on the device.
- Point the nozzle outlet away from your eyes and towards the interdental spaces for effective cleaning.
- Move the device along the gumline and interdental spaces, gently applying pressure for a thorough clean.
- After each use, wash the device and the used nozzles as indicated in the Maintenance section (clause Daily Care).
- Do not use the nozzle (16) in the Light mode to avoid damage to periodontal pockets.
The AENO ADI0001 Irrigator is designed for oral care, and cleaning plaque and food debris in hard-to-reach places.
DESCRIPTION
Specifications
- Power input parameters: 5 V (DC), 1.0 A, 5.0 W (max)
- Battery : non-detachable, lithium-ion; 2200 mA·h, 3.7 V (DC).
- Noise level (at a distance of 0.3 m): ≤ 69 dB. Water pressure: 206–689 kPa.
- Pulsation: 1500 pulses/min.
- Full battery charging time: 4.5 h.
- Water tank: 200 ml.
- Casing’s protection degree: IPX7.
- Operating time after a full charge: not less than 45 minutes.
- Operating time with a full tank: not less than 55 s.
- Size (L×W×H): 70×45×223 mm.
- Operating conditions : temperature +5…+40 °C, humidity 45–75 %.
- Storage conditions: temperature 0…+50 °C, humidity 45–90 %.
Package contents (Figures b, c)
Irrigator AENO ADI0001 (white) (11), 4 replaceable nozzles (13–16), cable USB
(A)/USB (C) (1 m) (12), case for replaceable nozzles (9), quick start guide.
Limitations and Warnings
- Monitor the use of the device by children under the age of 12 and persons with physical or mental disabilities.
- Do not allow children to play with the device. If you have oral diseases, you should consult your dentist before using the device.
- Do not switch on a damaged device.
- Do not leave the device plugged in unsupervised.
- Do not use the irrigator and do not perform maintenance on the device or its accessories unless the device is disconnected from the power supply.
Please use purified water without adding mouthwash, or other. If you have any
questions or issues with your AENO device, please contact our online support
team at support@aeno.com or
aeno.com/service-and-warranty. This is
a better option than visiting the store and will save you time and effort.
liquids or substances. Do not point the nozzle outlet into your eyes while the
unit is operating.
Preparing the device for operation
Unpack the device. Wipe its casing with a cloth soaked in a little water and wipe it dry. Disconnect the tank ( see fig. f ). Rinse and dry the tank and nozzles as described in the “Maintenance” section, clause “Daily Care ”.
Charging the device
WARNING! The power adapter is not included in the package. You can use the AC adapter from a smartphone, tablet, or other device as long as it provides 5 V, 1.0 A power parameters (DC).
Connect the device to the mains as shown in figure d. Status of the battery charge indicator (6) during charging:
- the device is charging – the indicator blinks red;
- the device is fully charged – the indicator lights green.
- When charging is completed, unplug the device, disconnect the cable (12), and close the USB port (8) by firmly inserting the blind plug. Charge the device for at least 12 hours before using it for the first time.
- Status of the battery charge indicator (6) in the operating mode:
- the charge level is less than 5 % – the indicator blinks red rapidly, the device does not turn on;
- the charge level is 5–10 % – the indicator blinks red slowly;
- the charge level is 10–100 % – the indicator is off.
- When the device is charged, place one of the replaceable nozzles (13–16) on the casing by pushing it until it clicks. The nozzle can spin 360°.
- Purpose of the irrigator nozzles (Figure C):
- standard nozzle for cleaning food debris, plaque (13);
- tongue cleaner nozzle (14);
- orthodontic nozzle for braces, and dentures (15);
- nozzle for cleaning of the periodontal pockets (16). aeno.com/documents
Fill the water tank (2) as shown in figure g. Close the water fill cap (10) tightly. After that, go on to select the operating mode of the device .
Setting the operating mode of the device
- To set the operating mode, point the nozzle’s outlet in a safe direction so that the water jet does not damage the interior and so that you can see the mode selection panel (5).
- Press the button (3) to turn on the device. The operating mode indicator on the irrigator panel (5) will light up.
- Use the mode selection button (4) to select the desired mode. The first time you turn on the device, the default operating mode is “High”. Subsequent single presses of the mode selection button (4) alternately change the operating modes, which are displayed on the panel (5).
Device operating modes
- “High”: intensive cleaning for healthy gums;
- “Medium”: daily standard cleaning, plaque removal;
- “Light”: gentle cleaning for sensitive teeth and gums. Also recommended for first-time users of the device;
- “Spot”: thorough oral care, removal of food remnants from interdental spaces, prevention of tartar formation. Water is ejected when button (3) is pressed.
Each mode of the device has three power levels:
- High,
- Medium,
- Low.
To switch the power level, press and hold the button (4) for 3 (three) seconds. The mode and its power level, set during the last use, will be automatically selected the next time the irrigator is turned on. Turn off the device by using the button (3). Device operation Point the nozzle’s outlet (1) into your mouth cavity. Press the button (3) to turn on the device. Move the nozzle’s outlet (1) along the gum contour as shown in figure h. During the cleaning, you can switch the operating mode and its power level with the button (4). When you have finished the cleaning, press the button (3) to turn the device off. If you do not turn off the device, it will automatically turn off no later than 2 (two) minutes. After each use, wash the device and the used nozzles as indicated in the “Maintenance” section (clause “Daily Care ”).
NOTE. It is not recommended to use the nozzle (16) in the “Light” mode to avoid damage to periodontal pockets.
Maintenance
- Daily maintenance. Open the filler cap (10) and drain off any water remaining in the tank. Disconnect the nozzle as shown in figure e. Rinse the tank and nozzles in warm running water, without detergents or cleaning agents, and dry thoroughly.
- Total care. A total cleaning of the water tank must be performed once a week. To do this, disconnect the tank as shown in picture f. Wash it inside and outside in warm running water with a soft brush or sponge, without detergents or cleaning agents, and dry thoroughly.
Troubleshooting
- The device does not turn on. Possible reason: the battery is low.
- Solution: charge the device for at least 4.5 hours.
- The device does not supply water. Possible causes: the nozzle’s outlet is clogged, and the water tank is out of water.
- Solution : fill the tank with water, and clean the nozzle’s outlet.
- Operating time after a full charge is less than 10 minutes. Possible reason: the battery does not hold charge.
- Solution : contact the service center to replace the battery of the device.
WARNING! If none of the suggested solutions solves the problem, contact your supplier or service center. Do not disassemble or attempt to repair the device by yourself.
Recycling information
These symbols indicate that you must follow the Waste Electrical and
Electronic Equipment (WEEE) and Waste Battery and Battery Regulations when
disposing of the device, its batteries and accumulators, and its electrical
and electronic accessories. According to the rules, this equipment must be
disposed of separately at the end of its service life. Do not dispose of the
device, its batteries, and accumulators, or its electrical and electronic
accessories together with unsorted municipal waste, as this will harm the
environment. To dispose of this equipment, it must be returned to the point of
sale or turned into a local recycling facility. You should contact your local
household waste disposal service for details.
Download the full warranty card on aeno.com
Please contact our online support team if you have any questions or issues with vour AENO device.
Get support
aeno.com/service-and-warranty
References
- Home appliances AENO - Smart home appliances on the official website of the manufacturer AENO in Europe
- Documents | AENO in Europe
- Dokumenty | AENO w Polsce
- aeno.com/service-and-warranty
- aeno.com/sk/documents
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>