SURE SP15AZ60AJ2NA Vantix Line iM Heat Pumps Instruction Manual

June 13, 2024
SURE

SURE SP15AZ60AJ2NA Vantix Line iM Heat Pumps

Product Information

The Heat Pumps SP15AZ is part of the VantixTM Line iM Heat Pumps. It has cooling efficiencies of up to 16 SEER2 / 11.7 EER2 and heating efficiencies of up to 8.1 HSPF. The nominal sizes range from 1.5 to 5 tons [5.3 to 17.6 kW] with cooling and heating capacities ranging from 13.36 kBTU to 45.6 kBTU. Proper sizing and installation of the equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star standards.

Features and Benefits

  • 2-Stage Cooling and Heating
  • All-Region Design
  • R-410A Refrigerant
  • Multiple Capacity Options
  • Energy Efficient – Up to 16 SEER2 / 11.7 EER2 Cooling Efficiencies
  • Quiet Operation

Model Number Identification
The model number SP15AZ is decoded as follows:

  • S – Sure Comfort Brand
  • P – Heat Pump
  • 15 – 15.2 SEER2
  • A – All Regions
  • Z – R-410A Refrigerant
  • 18 – 18,000 [5.28 kW] Capacity
  • J – 208/230/1/60 Voltage
  • 2 – 2+ Stage Controls
  • N – Non-Comm. Minor Series

Available Models

  • SP15AZ18AJ2NA – VantixTM Line 1 1/2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
  • SP15AZ24AJ2NA – VantixTM Line 2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
  • SP15AZ30AJ2NA – VantixTM Line 2 1/2 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
  • SP15AZ36AJ2NA – VantixTM Line 3 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
  • SP15AZ42AJ2NA – VantixTM Line 3 1/2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
  • SP15AZ48AJ2NA – VantixTM Line 4 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
  • SP15AZ60AJ2NA – VantixTM Line 5 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60

General Data/Electrical Data
The following are the general data and electrical data for the SP15AZ models:

Model No.| Nominal Tonnage| Valve Connections| Number of Blades| Motor hp| CFM| RPM| Watts
---|---|---|---|---|---|---|---
(-)P15AZ 18AJ2NA| 1.5| 0.375| 2| 1/6| 2582| 1075| 145
(-)P15AZ 24AJ2NA| 2| 0.375| 2| 1/6| 2582| 1075| 145
(-)P15AZ 30AJ2NA| 2.5| 0.375| 3| 1/5| 4077| 850| 222
(-)P15AZ 36AJ2NA| 3| 0.375| 3| 1/5| 4206| 850| 246
(-)P15AZ 42AJ2NA| 3.5| 0.375| 3| 1/5| 4206| 850| 246
(-)P15AZ 48AJ2NA| 4| 0.375| 3| 1/5| 4206| 850| 246
(-)P15AZ 60AJ2NA| 5| 0.375| 3| 1/5| 5106| 850| 294

The electrical data for the models are as follows:

Model No.| Line Voltage Data (Volts-Phase-Hz)| Compressor Rated Load Amps| Compressor Locked Rotor Amps| Condenser Fan Motor Full Load Amps| Condenser Fan Motor Locked Rotor Amps
---|---|---|---|---|---
(-)P15AZ 18AJ2NA| 208/230-1-60| 8| 56| 0.75| 1.5
(-)P15AZ 24AJ2NA| 208/230-1-60| 11| 61| 0.75| 1.5
(-)P15AZ 30AJ2NA| 208/230-1-60| 14| 87| 1.0| 2.56
(-)P15AZ 36AJ2NA| 208/230-1-60| 15| 102| 1.0| 2.56
(-)P15AZ 42AJ2NA| 208/230-1-60| 20| 151| 1.0| 2.56
(-)P15AZ 48AJ2NA| 208/230-1-60| 21| 0| 1.0| 2.56
(-)P15AZ 60AJ2NA| 208/230-1-60| 24| 151| 1.0| 2.56

Accessories/Weighted Sound Power
The following accessories are available for the SP15AZ models:

  • Compressor crankcase heater* – Model No.: 44-17402-44
  • Low ambient control – Model No.: RXAD-A08

SP15AZ

  • Cooling Efficiencies up to: 16 SEER2 / 11.7 EER2
  • Heating Efficiencies up to: 8.1 HSPF
  • Nominal Sizes: 1.5 to 5 Tons [5.3 to 17.6 kW]
  • Cooling & Heating Capacities: 13.36 kBTU to 45.6 kBTU

*Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.

Features and Benefits

  • Two-Stage Scroll Compressor: Features two speeds (high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors
  • 7 mm Condenser Copper Coil1: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • Inverted Reversing Valve: Allows for faster heat transfer with gravity-assist shifting and reduced joint stress for increased reliability
  • Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space — provides a minimum working area of 27 square inches for easier access
  • Triple Service Access: 15″ wide, industry leading corner service access, two fastener, removable corner and individual louver panels — makes repairs easier and faster

Heat Pumps

[ ] Designates Metric Conversions

AVAILABLE MODELS DESCRIPTION
SP15AZ18AJ2NA Vantix™ Line 1 1/2 ton 15.2 SEER2 2-Stage iM Heat

Pump-208/230/1/60
SP15AZ24AJ2NA| Vantix™ Line 2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
SP15AZ30AJ2NA| Vantix™ Line 2 1/2 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
SP15AZ36AJ2NA| Vantix™ Line 3 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
SP15AZ42AJ2NA| Vantix™ Line 3 1/2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
SP15AZ48AJ2NA| Vantix™ Line 4 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
SP15AZ60AJ2NA| Vantix™ Line 5 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
STANDARD EQUIPMENT

R-410A Refrigerant
Scroll Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays

General Data


MODEL NO.| (-)P15AZ 18AJ2NA| (-)P15AZ 24AJ2NA| (-)P15AZ 30AJ2NA| (-)P15AZ 36AJ2NA| (-)P15AZ 42AJ2NA| (-)P15AZ 48AJ2NA| (-)P15AZ 60AJ2NA
Nominal Tonnage|  |  |  |  |  |  |
Valve Connections|
Liquid Line O.D. – in.| 0.375| 0.375| 0.375| 0.375| 0.375| 0.375| 0.375
Suction Line O.D. – in.| 0.75| 0.75| 0.75| 0.75| 0.875| 0.875| 0.875
Refrigerant (R410A) furnished oz.¹| 118| 118| 120| 127| 143| 146| 220
Compressor Type| 2-stage Scroll
Outdoor Coil|
Net face area – Outer Coil| 10.9| 10.9| 19.5| 21.5| 21.5| 21.5| 32.5
Net face area – Inner Coil| 10.5| 10.5|  |  |  |  |
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276| 0.276| 0.276| 0.375
Number of rows| 2| 2| 1| 1| 1| 1| 1
Fins per inch| 22| 22| 22| 22| 22| 22| 20
Outdoor Fan|
Diameter – in.| 20| 20| 24| 24| 24| 24| 26
Number of blades| 2| 2| 3| 3| 3| 3| 3
Motor hp| 1/6| 1/6| 1/5| 1/5| 1/5| 1/5| 1/5
CFM| 2582| 2582| 4077| 4206| 4206| 4206| 5106
RPM| 1075| 1075| 850| 850| 850| 850| 850
watts| 145| 145| 222| 246| 246| 246| 294
Shipping weight lbs.| 157| 157| 209| 221| 247| 247| 298
Operating weight lbs.| 150| 150| 202| 214| 240| 240| 291

Electrical Data

Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
---|---|---|---|---|---|---|---
Maximum overcurrent protection (amps)²| 15| 25| 30| 30| 45| 45| 50
Minimum circuit ampacity³| 11| 15| 18| 20| 26| 28| 31
Compressor|
Rated load amps| 8| 11| 14| 15| 20| 21| 24
Locked rotor amps| 56| 61| 87| 102| 151| 0| 151
Condenser Fan Motor|
Full load amps| 0.75| 0.75| 1.0| 1.0| 1.0| 1.0| 1.0
Locked rotor amps| 1.5| 1.5| 2.56| 2.56| 2.56| 2.56| 2.56

¹ Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories

MODEL NO.| (- )P15AZ18| (- )P15AZ24| (- )P15AZ30| (- )P15AZ36| (- )P15AZ42| (- )P15AZ48| (- )P15AZ60
---|---|---|---|---|---|---|---
Compressor crankcase heater*| 44-17402-44| 44-17402-44| 44-17402-44| 44-17402-44| 44-17402-45| 44-17402-45| Factory Standard
Low ambient control| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08
Compressor sound cover| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-25| 68-23427-25| 68-23427-25
Compressor hard start kit| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1
Low pressure control| Factory Standard| Factory Standard| Factory Standard| Factory Standard| Factory Standard| Factory Standard| Factory Standard
High pressure control| Factory Standard| Factory Standard| Factory Standard| Factory Standard| Factory Standard| Factory Standard| Factory Standard
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD3T3TVLC| 200RD3T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD3T3TVLC| 200RD3T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
Classic Top Cap w/Label| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21

*Bi-flow kits are required when installing a liquid line solenoid on a heat pump.

Weighted Sound Power Level (dBA)

UNIT SIZE – VOLTAGE, SERIES| STANDARD RATING (DBA)| TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
SP15AZ18A| 73| 58.0| 58.8| 62.0| 62.3| 59.2| 56.6| 50.5
SP15AZ24A| 73| 56.6| 59.6| 62.2| 62.1| 58.8| 55.4| 50.8
SP15AZ30A| 72| 48.9| 55.3| 63.6| 61.0| 59.1| 56.5| 48.7
SP15AZ36A| 74| 51.2| 56.4| 63.1| 63.8| 60.8| 57.4| 56.5
SP15AZ42A| 74| 56.8| 58.7| 65.9| 66.2| 62.9| 59.4| 54.2
SP15AZ48A| 74| 57.3| 56.6| 64.1| 64.0| 61.1| 58.0| 56.5
SP15AZ60A| 74| 43.9| 55.2| 63.4| 65.8| 61.7| 57.9| 52.9

NOTE : Tested in accordance dard 270-08 (not listed in AHRI)

Unit Dimensions


MODEL NO.

| OPERATING| SHIPPING
---|---|---
H (Height)| L (Length)| W (Width)| H (Height)| L (Length)| W (Width)
INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm
(-)P15AZ18AJ2NA| 25.00| 635.00| 29.75| 755.65| 29.75| 755.65| 27.90| 708.66| 33.25| 844.55| 33.25| 844.55
(-)P15AZ24AJ2NA| 25.00| 635.00| 29.75| 755.65| 29.75| 755.65| 27.90| 708.66| 33.25| 844.55| 33.25| 844.55
(-)P15AZ30AJ2NA| 35.00| 889.00| 33.75| 857.25| 33.75| 857.25| 38.35| 974.09| 37.64| 956.06| 37.64| 956.06
(-)P15AZ36AJ2NA| 39.00| 990.60| 33.75| 857.25| 33.75| 857.25| 42.35| 1075.69| 37.64| 956.06| 37.64| 956.06
(-)P15AZ42AJ2NA| 39.00| 990.60| 33.75| 857.25| 33.75| 857.25| 42.35| 1075.69| 37.64| 956.06| 37.64| 956.06
(-)P15AZ48AJ2NA| 39.00| 990.60| 33.75| 857.25| 33.75| 857.25| 42.35| 1075.69| 37.64| 956.06| 37.64| 956.06
(-)P15AZ60AJ2NA| 51.00| 1295.40| 35.75| 908.05| 35.75| 908.05| 54.50| 1384.30| 39.37| 1000.00| 39.37| 1000.00

[ ] Designates Metric Conversions

CLEARANCES

NOTE : NUMBERS IN () = mm
IMPORTANT : When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventilation to prevent re- circulation of the discharge air.

Refrigerant Line Size Information

SINGLE AND TWO-STAGE HEAT PUMPS



UNIT SIZE

| ****

MAX. LIQUID LINE SIZE

| ****

SUCTION LINE SIZE

| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH IN FEET
0- 15| 16- 25| 26- 50| 51- 80| 81- 100| 101- 125| 126- 150
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER


1.5 TON

| ****

3/8″

| 1/2″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.97| 100 / 0.97| 115 / 0.96| 115 / 0.95
5/8″| 15 / 1| 25 / 1| 50 / 1| 80 / 0.99| 100 / 0.99| 115 / 0.99| 115 / 0.98
3/4″| 15 / 1| 25 / 1| 50 / 1| 80 / 0.99| 100 / 0.99| 115 / 0.99| 115 / 0.98
2 TON| 3/8″| 5/8″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.98| 100 / 0.97| 100 / 0.96| 95 / 0.95
3/4″| 15 / 1| 25 / 1| 50 / 1| 80 / 0.99| 100 / 0.99| 100 / 0.99| 95 / 0.98


2.5 TON

| ****

3/8″

| 5/8″| 15 / 1| 25 / 0.99| 50 / 0.98| 80 / 0.97| 95 / 0.96| 90 / 0.94| 85 / 0.93
3/4″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.99| 95 / 0.98| 90 / 0.98| 85 / 0.97


3 TON

| ****

3/8″

| 5/8″| 15 / 1| 25 / 0.99| 50 / 0.97| 80 / 0.95| 85 / 0.94| 80 / 0.92| 75 / 0.9
3/4″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.98| 85 / 0.98| 80 / 0.97| 75 / 0.96
7/8″| 15 / 1| 25 / 1| 50 / 1| 80 / 0.99| 85 / 0.99| 80 / 0.99| 75 / 0.98
3.5 TON| 3/8″| 3/4″| 15 / 1| 25 / 0.99| 50 / 0.98| 80 / 0.97| 80 / 0.97| 70 / 0.96| 65 / 0.95
7/8″| 15 / 1| 25 / 1| 50 / 0.99| 80 / 0.99| 80 / 0.99| 70 / 0.98| 65 / 0.98
4 TON| 3/8″| 3/4″| 15 / 1| 25 / 0.99| 50 / 0.98| 75 / 0.97| 70 / 0.96| 60 / 0.95| 50 / 0.94
7/8″| 15 / 1| 25 / 1| 50 / 0.99| 75 / 0.99| 70 / 0.98| 60 / 0.98| 50 / 0.97
5 TON| 3/8″| 3/4″| 15 / 1| 25 / 0.99| 50 / 0.97| 65 / 0.95| 45 / 0.94| 30 / 0.92| 15 / 0.9
7/8″| 15 / 1| 25 / 0.99| 50 / 0.99| 65 / 0.98| 45 / 0.97| 30 / 0.96| 15 / 0.96

NOTES:

  • Maximum Equivalent Line Length may not exceed 250′.
  • Maximum Actual Line Length may not exceed 200′.
  • Light Grey shaded areas are considered long line and may require accessories as recommended in Long Line Set Guide.
  • Refer to supplemental Long Line Set Guide for applications that require liquid line size other than 3/8″.
  • DO NOT use suction line traps in the suction riser as this adds additional unwanted pressure drop in the system.

SINGLE AND TWO-STAGE HEAT PUMPS



UNIT SIZE

| ****

MAX. LIQUID LINE SIZE

| ****

SUCTION LINE SIZE

| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH IN METERS
0- 5| 5.5- 8| 8.5- 15| 15.5- 24| 24.5- 30| 30.5- 38| 38.5- 46
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER


1.5 TON

| ****

3/8″

| 1/2″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.97| 30 / 0.97| 35 / 0.96| 35 / 0.95
5/8″| 5 / 1| 8 / 1| 15 / 1| 24 / 0.99| 30 / 0.99| 35 / 0.99| 35 / 0.98
3/4″| 5 / 1| 8 / 1| 15 / 1| 24 / 0.99| 30 / 0.99| 35 / 0.99| 35 / 0.98
2 TON| 3/8″| 5/8″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.98| 30 / 0.97| 30 / 0.96| 29 / 0.95
3/4″| 5 / 1| 8 / 1| 15 / 1| 24 / 0.99| 30 / 0.99| 30 / 0.99| 29 / 0.98


2.5 TON

| ****

3/8″

| 5/8″| 5 / 1| 8 / 0.99| 15 / 0.98| 24 / 0.97| 29 / 0.96| 27 / 0.94| 26 / 0.93
3/4″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.99| 29 / 0.98| 27 / 0.98| 26 / 0.97


3 TON

| ****

3/8″

| 5/8″| 5 / 1| 8 / 0.99| 15 / 0.97| 24 / 0.95| 26 / 0.94| 24 / 0.92| 23 / 0.9
3/4″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.98| 26 / 0.98| 24 / 0.97| 23 / 0.96
7/8″| 5 / 1| 8 / 1| 15 / 1| 24 / 0.99| 26 / 0.99| 24 / 0.99| 23 / 0.98
3.5 TON| 3/8″| 3/4″| 5 / 1| 8 / 0.99| 15 / 0.98| 24 / 0.97| 24 / 0.97| 21 / 0.96| 20 / 0.95
7/8″| 5 / 1| 8 / 1| 15 / 0.99| 24 / 0.99| 24 / 0.99| 21 / 0.98| 20 / 0.98
4 TON| 3/8″| 3/4″| 5 / 1| 8 / 0.99| 15 / 0.98| 23 / 0.97| 21 / 0.96| 18 / 0.95| 15 / 0.94
7/8″| 5 / 1| 8 / 1| 15 / 0.99| 23 / 0.99| 21 / 0.98| 18 / 0.98| 15 / 0.97
5 TON| 3/8″| 3/4″| 5 / 1| 8 / 0.99| 15 / 0.97| 20 / 0.95| 14 / 0.94| 9 / 0.92| 5 / 0.9
7/8″| 5 / 1| 8 / 0.99| 15 / 0.99| 20 / 0.98| 14 / 0.97| 9 / 0.96| 5 / 0.96

NOTES:

  1. Maximum Equivalent Line Length may not exceed 76 Meters.
  2. Maximum Actual Line Length may not exceed 61 Meters.
  3.  Light Grey shaded areas are considered long line and may require accessories as recommended in Long Line Set Guide.
  4. Refer to the supplemental Long Line Set Guide for applications that require liquid line size other than 3/8″.
  5. DO NOT use suction line traps in the suction riser as this adds additional unwanted pressure drop in the system.

Performance Data @ AHRI Standard Conditions – Cooling

DESIGNATED TESTED COMBINATION (DTC)


OUTDOOR UNIT

| ****

AIR HANDLER

| TOTAL CAPACITY BTU/H [kW]| NET SENSIBLE BTU/H [kW]| NET LATENT BTU/H [kW]| ****

SEER2

| ****

EER2

| ****

INDOOR CFM [L/S]

| 47 DEGREE HEATING CAPACITY BTU/H [KW]| 47

DEGREE COP

| 17 DEGREE HEATING CAPACITY BTU/H [KW]| 17

DEGREE COP

| REGION IV HSPF2
(-)P15AZ18AJ2N| RH2TZ2417STANN| 17,100 [5.0]| 13,100 [3.8]| 4,000 [1.2]| 15.2| 11.7| 625 [295.0]| 17,100 [5.0]| 3.87| 11,600 [3.4]| 2.6| 7.8
(-)P15AZ24AJ2N| RH2TZ2417STANN| 22,800 [6.7]| 17,400 [5.1]| 5,400 [1.6]| 15.2| 11.7| 775 [365.8]| 22,600 [6.6]| 3.88| 15,600 [4.6]| 2.8| 7.8
(-)P15AZ30AJ2N| RH2TZ3617STANN| 28,400 [8.3]| 21,800 [6.4]| 6,600 [1.9]| 15.2| 11.7| 900 [424.8]| 28,400 [8.3]| 3.62| 19,700 [5.8]| 2.6| 7.8
(-)P15AZ36AJ2N| RH2TZ3617STANN| 34,200 [10.0]| 26,200 [7.7]| 8,000 [2.3]| 15.2| 11.7| 1,050 [495.5]| 34,200 [10.0]| 3.62| 24,400 [7.2]| 2.7| 7.8
(-)P15AZ42AJ2N| RH2TZ4821STANN| 40,000 [11.7]| 30,500 [8.9]| 9,500 [2.8]| 15.2| 11.7| 1,325 [625.3]| 39,500 [11.6]| 3.95| 28,200 [8.3]| 2.9| 7.8
(-)P15AZ48AJ2N| RH2TZ4821STANN| 45,500 [13.3]| 35,000 [10.3]| 10,500 [3.1]| 15.2| 11.7| 1,450 [684.3]| 45,000 [13.2]| 3.92| 33,200 [9.7]| 2.9| 7.8
(-)P15AZ60AJ2N| RH2TZ6024STANN| 57,000 [16.7]| 43,500 [12.7]| 13,500 [4.0]| 15.2| 11.7| 1,800 [849.5]| 57,000 [16.7]| 4.04| 42,500 [12.5]| 3.0| 7.8

NOTE : This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, will be accessible from the AHRI website: www.ahridirectory.org later this year.

GENERAL TERMS OF LIMITED WARRANTY

Sure Comfort® will furnish a replacement for any part of this product that fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.

Conditional Parts

  • (Registration Required) ……………………………Ten (10) Years

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
© 2023 Rheem Manufacturing Company. Sure Comfort trademarks owned by Rheem Manufacturing Company.
In keeping with its policy of continuous progress and product improvement, Sure Comfort reserves the right to make changes without notice.

Sure Comfort • 5600 Old Greenwood Road
Fort Smith, Arkansas 72908 • www.surecomfort.com
Sure Comfort Canada • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5 • surecomfort.ca