LED WORLD FA60M28-5M-12V-X Bright Plus LED Strip Light Instruction Manual
- June 4, 2024
- LED WORLD
Table of Contents
- LED WORLD FA60M28-5M-12V-X Bright Plus LED Strip Light
- IMPORTANT INSTRUCTIONS
- INSTALLATION PLANNING
- FLEX STRIP CONNECTION
- MOUNTING NOTE
- WIRIN-G FOR VOLTAGE DROP
- WATTAGE CALCULATION
- LAYOUT OPTIONS
- POWERING OPTION
- CONNECTION OPTION
- LED STRIP CUTTING
- Maximum band radius 4
- MAXIMUM FLEXSTRIP LENGTH SUPPORTED BY LED WORLD’s CLASS 2 POWER SUPPLY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LED WORLD FA60M28-5M-12V-X Bright Plus LED Strip Light
IMPORTANT INSTRUCTIONS
Never Nail or use Staples Never apply weights or walk on strips Only power with 12VDC Class 2 Power Source Apply to surface at room temperature. Keep away from flammable materials. Surface temperature MAX 40°C (104°F). Don’t install under, above or near heat sources (i.e. stoves, fireplaces.
SAFETY & WARNINGS
Before using this product make sure you have right color, product item
number and voltage (printed on product). Check for possibility of damage
during shipping. If damaged, or wrong product, do not use. Disconnect power
before installing or using. Use only with Class 2 Type power supply. Using
with any other type of power supply will void the limited warranty.
- Use only with LED World’s Class 2 Type power supply.
- Indoor use, Dry locations.
- Do not expose LED Flex Strip to moisture.
- Disconnect power before installing or servicing at breaker point.
- This product is intended to be installed and serviced by a qualified licensed electrician.
- Install in accordance with the National Electric Code, and local regulations.
- Only power with a (listed) constant voltage Class 2 power supply (12V DC).
- Never plug into 120V AC.
- The product requires a optional class 2 Transformer Power Supply.
- Do not power when rolled. Lighting must be installed in a straight line on a flat surface.
- Do not curl or twist and roll out completely straight before applying power.
- Only install on smooth flat surfaces free of burrows that are fire retardant.
- Product has an adhesive tape on back.
- Adhesion can only be made once and the LED strip must fully adhere to surface flush.
- Failure to do this step will damage product.
- Rigidly support wires with wire clamps.
- During installation, do not damage the printed circuit.
- Exposed wires can cause short circuit damaging product and creating a serious hazard.
- Do not mount in a manner or support LED Strip light in a manner that can damage the outer jacket or cord insulation.
- Do not install this lighting system where the exposed bare conductors can be shorted or contact any conductive materials.
- Carefully check that there is no wire cross-over or possibility in the future in area of installation.
- To reduce the risk of fire and overheating, make sure all connections are tight.
- Product is sold in the maximum length. Do not exceed or extend the length of the roll.
- Only qualified electrician or engineer can perform installation familiar with low voltage wiring techniques.
- Correct polarity is imperative +/- is marked on printed circuit.
- Parallel connection only.
- DO NOT install on flammable material or possibility of in the future.
- Do not install any luminaire closer than 6 inches (15.25 cm) from any curtain, or similar combustible materials.
- The light and all its components cannot be mechanically pressed. Never apply to surface above 40c (104F).
- Voltage must not exceed 12VDC and must be regulated.
- The Voltage is printed every 3 LEDS.
- Check that it is the correct voltage before applying power.
- This is not a toy.
- Keep out of children’s reach.
- Keep Flex strip spaced ¾ apart if placing next to each other.
- LED Flex Strip is bendable on one flat widest plane.
- Maximum bend radius is 4 inches (100mm) on one plane (flat).
- Not for use in mission critical, aircraft, emergency signs or lifesaving equipment.
- Static electricity can damage LED.
- Handle with care.
- Inspect installation after one hour and thereafter regularly.
- For stationary use only and not subjected to possible pressure or movement or in the future.
- Not for in-wall use.
- Max Soldering temperature cannot exceed 250°C (482°F) for a max of 4 seconds.
- Use 22~20 AWG wire to connect.
- Use correct wiring as required by local electrical code.
- Use a 20 gauge wire to attach to strip by solder 2464 type of wire.
- Connection to power source may use Wago 222-413 in hardwire applications.
- Conductors of extra-low-voltage circuits be rigidly supported.
- Conductors not be installed in contact with combustible materials and not run through walls, ceilings, floors or partitions, and Uninsulated conductors not be installed less than 2.2 m (86) from the floor.
- Do not stare directly into the LED Light. Install LED lighting out of direct sight.
FIVE YEAR LIMITED LIGHTING WARRANTY
LED WORLD INC. warranties this product for five year (some exceptions may
apply) from the date of shipping unless otherwise noted in writing. This
warranty is expressly in lieu of all other warranties expressed or implied.
Under this Limited Warranty, the obligation of the company is limited to
replacing on a prorated basis, at its option, any component found to be
defective. This Limited Warranty does not apply to damage caused by buyer or
alteration to the product or incorrect power supply. Factory warrantees are
covered by the original manufacturer and claims must be submitted to them.
This product must be used with LED World’s class 2 power supply. Failure to do
so will void limited warranty. LED World Inc. And its providers will never be
liable to you or any other person for any indirect, incidental, consequential,
special, punitive or exemplary loss or damage arising from, connected with,
the purchase of products, including but not limited to loss of data, business,
markets, cost of labour, savings, income, profits, use, production, reputation
or goodwill, anticipated or otherwise, or economic loss, under any theory of
liability (whether in contract, tort, strict liability or any other theory or
law or equity), regardless of any negligence or other fault or wrongdoing
(including without limitation gross negligence and fundamental breach) by led
world inc or any person for whom led world inc is responsible, and even if led
world inc has been advised of the possibility of such loss or damage being
incurred.
If a product is defective, we will replace the product with similar or
identical product or at our option a credit towards a future purchase. To make
a claim under this warranty, obtain a return authorization number.
INSTALLATION PLANNING
LED Flexstrip is a versatile lighting product that can provide a superior lighting solution in a variety of applications. Recommend design steps before starting the installation process
General questions based on lighting requirements
- Where will your power supply be located
- How will you switch your LED lighting ON and OFF?
- What is the best layout configuration for your installation with wiring consideration?
- How will you run your wiring to your LED strip lighting?
FLEX STRIP CONNECTION
Wire connection using WAGO block connectors
Cut instructions
Note Polarity Marks
Polarity marks must match + to + and – to – otherwise strip will not work
Solder Connection Points
Solder connection points are at marked intervals. Cut points are at every 3 LEDs (12VDC)
MOUNTING NOTE
LED Strip is equipped with 3M self-adhesive tape. Mount strips on clean (no wax/oil), dry, smooth, burrows free surface. Adhesion can be made once and LED Strip must fully adhere to surface.
Use Aluminum profile or aluminum heat sink tape to avoid overheating , ensure proper heat dissipation and extend the life of the LED
WIRIN-G FOR VOLTAGE DROP
Voltage drop is normal loss of voltage that occurs as power flows along a wire connection in a low voltage systems, and increases as the length of a wire connection is increased. Wire length and thickness as well as total light wattage influence the amount of voltage drop.
Recommended maximum wire lengths 12VDC
Recommended maximum wire lengths – 12VDC
Wire Guage (AWG)| 20W| 30W| 50W| 60W| 90W| 100W
20 AWG| 13 FEET| 9 FEET| 5 FEET| 4 FEET| 3 FEET| 3 FEET
18 AWG| 21 FEET| 14 FEET| 8 FEET| 7 FEET| 5 FEET| 4 FEET
16 AWG| 34 FEET| 22 FEET| 13 FEET| 11 FEET| 7 FEET| 7 FEET
Download Magnitude app for voltage drop calculations
Android App
IOS App
WATTAGE CALCULATION
The LED Flex Strips have a label on each roll that indicates the voltage and wattage. You must have the correct Class 2 Power Supply (Transformer) for LED Strip model. To calculate the wattage, measure the total length of LED Strip in your run multiplied by the wattage of the LED Strip. Remember that a power source should only operate at a maximum 80% of it rated capacity.
For example
10 feet of FA60M28-5M-12V-X x 2.2W = 22 Watts. Never Extend the Length of
rolls. Rolls are sold in there max length.
LAYOUT OPTIONS
Layout 1
Note
- Always check the Wattage of your LED Strip or Fixture.
- Power Supply Wattage x 0.8 = Available Wattage
Class 2 Power Supply
Layout 2
Layout 3
POWERING OPTION
Option 2
Regulated Class 2 Power Supply
Option 3
Option 4
CONNECTION OPTION
Connect LED light strips with our optional strip connectors. Please our quick connector instruction sheet included with the connector bag. However, it is strongly recommended to solder the connection.
LED STRIP CUTTING
Our strips comes with cut mark sign. Strips are be cuttable at each 3 LEDs. Cut marks lying between set of soldering points.
TROUBLESHOOTING
Tape light strip does not light
- Make sure your power supply is turned on and has the correct voltage.
- Confirm you have the correct polarity (+ to + and – and -) throughout the run of LED Lighting.
- Have a electrician check all connections and any switch or dimmer connections from the power supply to the LED Light Strips.
- Consider testing with a multimeter to ensure light strip is receiving 12V power.
LED Flex Strip lights blink on, then go off
- The power supply is not adequate for the length of LED Light Strips you are powering.
- Install a adequate Class 2 power supply.
LEDs farthest from the power supply are noticeably dimmer
- This is the result of voltage drop.
- Decrease the length of the 12V power feed or use thicker power feed wires between the 12V power supply and the lighting strips.
IMPORTANT
Apply 1 ½long electrical heat shrink over all connection points. Secure connection wire with wire clamp.
Maximum band radius 4
Wrong
Right
- On widest one flat plane only.
- Do not bend sideways.
- Flexible on one axis.
MAXIMUM FLEXSTRIP LENGTH SUPPORTED BY LED WORLD’s CLASS 2 POWER SUPPLY
Power Supply| Max Feet of LED Flexstrips| Power Supply| Max Feet of LED
Flexstrips
---|---|---|---
MD-012-030VTDHV2
|
10.9 Feet Continuous 24 Watts
| MD-012-060VTDHV2|
21.8 Feet Continuous 48 Watts
MD-012-180VTD52JV2
|
3 X 21.8 Feet Continuous 48 Watts each channel
|
MD-012-300VTD52JV2
|
5 X 21.8 Feet Continuous 48 Watts each channel
References
- LED World Canada - A Commercial LED lighting supplier
- LED World Lighting - A Commercial LED lighting supplier