nuwave 47251 OxyPure Zero Smart Air Purifier User Guide
- June 13, 2024
- nuwave
Table of Contents
nuwave 47251 OxyPure Zero Smart Air Purifier User Guide
Table
Button | Name | Function | Use |
---|---|---|---|
**** | **POWER** | Turns the OxyPure® on and off. | Press POWER to |
turn the OxyPure® on and off.
****| **AUTO| Allows you to run the OxyPure at the lowest fan
speed, raising it based on PM level.| Press AUTO and the Auto back light
will turn on. There is no time limit on the Auto Mode. Press AUTO again to
deactivate Auto Mode.
****ECO MODE| Allows you to save energy by turning the OxyPure fan off
when it is not needed.| Press and hold AUTO for 1 second to activate Eco
Mode. When the air quality is poor, the unit will automatically run. When the
air quality is good, the unit will turn off. Press AUTO and hold for 1
second to deactivate Eco Mode.
**| ULTIMATE CLEAN| Automatically switches to the highest fan
speed when the PM level rises.| Press ULTIMATE CLEAN to activate the
Ultimate Clean Mode.
Wi-Fi MODE| Allows you to connect the OxyPure to your Wi-Finetwork|
Press and hold ULTIMATE CLEAN to initiate Wi-Fi pairing.
**| FLOW ANGLE| Adjusts the louver angles.| Press AIR FLOW ANGLE
to adjust the louver angles from 30°, 60°, 90°.
MUTE & UNMUTE| Turns the beeping on or off.| Press and hold FLOW
ANGLE to mute the OxyPure. Repeat to unmute.
**| FAN SPEED| Adjusts the OxyPure’s fan speed.| There are 6
fan speed levels. Press FAN SPEED to adjust from Speed 1 (lowest) to Speed
6 (highest).
SLEEP MODE| Turns off the control panel LED lights but keeps thefan
active.| Adjust the Fan Speed prior to activating Sleep Mode. Press and hold
FAN SPEED for 2 seconds to activate Sleep Mode. Press any button to
deactivate it.
**| TIMER| Helps limit the amount of time the OxyPure is on.| Press
TIMER to select from the 6 timer settings of 1/2, 1, 2, 4, 8 or 12 hours.
FILTER 2 RESET| Reset the Filter indicator| Press and hold
TIMER for 2 seconds to reset the FILTER 2 indicator.
**| **TURBO| Operates at the highest fan speed for a set time
(1/2 hour, 1 or 2 hours).| Press TURBO once to run the OxyPure at the
highest speed for ½ hour.
FILTER 4 RESET| Reset the Filter indicator| Press and hold
TURBO** for 2 seconds to reset the FILTER 4 indicator.
Customer Service: For Amazon Purchases: support@nuwavenow.com ● For All Other Purchases: help@nuwavenow.com
Before Use
- Make sure the OxyPure® is unplugged. Open the panel on the back to expose the filters.
- Pull the filters from their slots.
- Remove the plastic wrapping from the filters.
- Fully reinsert the filters into the Oxypure and close the panel.
- Remove the sticker from the control panel.
WI- FI Connection (Optional)
Connect the OxyPure to your home Wi-Fi network and pair it with your smart
device:
-
Download the NuWave® Connect app via the Apple Store or Google™ Play Store on your smartphone or device and open the app
-
Once you download the NuWave® Connect app, ensure your phone is connected to your home Wi-Fi network on the 2.4GHz frequency and that your phone’s Bluetooth is on.
-
Turn on the OxyPure and activate Wi-Fi Pairing Mode by pressing and holding ULTIMATE CLEAN until the light next to the Wi-Fi symbol begins to blink rapidly.
-
In the NuWave® Connect app, tap the + symbol, then tap Auto Scan and select your device.
-
Enter your Wi-Fi network’s password and tap Confirm. If the connection is successful, the app will display “Added Successfully” on the screen.
If you’re unable to pair your OxyPure using Auto Scan, follow the
instructions for AP Mode or EZ Mode on page 9 of the owner’s manual.
Wi-Fi LED Status Pairing Mode & AP Mode
Solid Light| The OxyPure® is paired with the Wi-Fi and ready to be used.
Rapid Blinking Light| The OxyPure is in Pairing Mode. The OxyPure will remain
in Pairing Mode for up to 3 minutes, or until your device is paired.
Slow Blinking Light| The OxyPure is in AP Mode.
No Light| The OxyPure’s Wi-Fi is off.
Filters
-
2. Bio-Guard® Filters (Lifespan up to 20 years)
- The 8,000-volt electrostatic filter captures airborne particles as small as 0.1 microns..
- The 8,000-volt electrostatic filter captures airborne particles as small as 0.1 microns..
-
Ozone (O3) Emission Removal Filter (Lifespan up to 20 years)
- Eliminates harmful ozone gas (O3) from the home to less than 3 part per billion (ppb), 17 times less than the EPA’s household standards of 50 ppb by converting Ozone to Oxygen.
-
Stainless-Steel Prefilter (Lifespan up to 20 years)
- Made from rust-free 18/8 stainless-steel.
- The durable, washable, and reusable Prefilter captures and collects large particles.
Air Filter Assembly
When maintaining the filters, unplug the unit and open the Filter Access Panel. You will see that the order of the filters, from the outside in, is as follows:
-
Stainless-Steel Prefilters
-
Bio-Guard® filters
-
Ozone Emission Removal filter
-
Bio-Guard® 4 360 filter
-
Open
-
Access to Filters
-
Removing & Inserting Filters
-
CAUTION
Unplug the OxyPure® from the power source before inserting or removing any
parts or attachments and before cleaning
The OxyPure® is easily movable with wheels on the bottom. Before moving your OxyPure, turn it off and unplug it from the outlet. Your settings will be saved and will automatically activate next time the unit is turned on
Cleaning & Maintenance
Filter Maintenance Indicator
The FILTER 2 and FILTER 4 lights will turn green in about 3 months to alert
you that the Bio-Guard® filters SHOULD be cleaned to maintain optimal
performance (NuWave Recommendation). When either light turns red (after about
6 months), that Bio-Guard® filter MUST be cleaned. Once cleaned, press and
hold TIMER or TURBO for 2 seconds to reset the FILTER 2 and FILTER 4 indicator
lights respectively
Cleaning the Filters
The filters need to be cleaned on schedule to help the unit maintain
optimum performance.
- Remove the Filter Access Panel in the r ear of the OxyPure® using its built-in handle.
- Slide out the filters that need cleaning.
- Always allow the washable filters to dry completely, out of direct sunlight, before you reinstall them. Never place a wet filter into the OxyPure.
- Reattach and close the Filter Access Panel. If the panel is not properly closed, the POWER button will blink red and the unit will not power on.
General Filter Cleaning Tips
-
Always Wear a Mask and Use Rubber gloves.
Prevents accidental inhalation of any contaminants when cleaning your filters. -
Move the OxyPure, Not the Filters
Minimizes filter shaking. -
Handle the Filters Carefully
Be careful not to agitate the filters to avoid releasing trapped contaminants. -
Dry the Filters Completely
Never install a wet or damp filter into your OxyPure.
To Clean the Ozone Emission Removal Filters
- Remove the filters. If possible, take them outside to clean.
- Gently, but thoroughly, clean the filters using a brush-tipped vacuum.
- Repeat the process on the other side. DO NOT GET WET.
To Clean the Stainless-Steel Prefilters
The Prefilters need to be cleaned at least once every two months, depending
on use.
- Use a brush-tipped vacuum to remove any dust or lint.
Cleaning the Odor Sensor
- The Odor Sensor is behind the three slots above the Dust Sensor Cover and may ONLY be cleaned using a brush-tipped vacuum.
Note: If you are unable to close the Filter Access Panel for any reason, the OxyPure will not operate and you will need to contact NuWave Customer Service. Exercise caution to ensure the tabs are not damaged when securing the Filter Access Panel.
Cleaning the Dust Sensor
The Dust Sensor is located on the side of the unit.
- Open the Dust Sensor Cover.
- Using a dry cotton swab, gently remove any dirt or dust from the Dust Sensor.
- For more buildup on the Dust Sensor, wipe it with a slightly wet cotton swab.
- Remove any moisture with a dry cotton swab.
- The Dust Sensor requires regular cleaning (approximately every 3 months) for the unit to operate efficiently.
- If your OxyPure is set up in an area with high dust accumulation, more frequent cleaning of the Dust Sensor is needed.
- Do not use the cotton swab on any part or area other than the Dust Sensor
**Do not immerse the OxyPure in water. Clean the outside of the unit with a damp sponge or cloth and wipe it dry. Make sure all parts and covers are securely attached.
Do not dry the filters in direct sunlight or with a hot blow dryer. Do
not use a vacuumcleaner or too stiff a brush to clean the Bio-Guard filters
** EPA Establishment Number: 101594-CHN-1
©2023 NuWave® LLC • All Rights Reserved.
Item: BQ47251- 47261 • Rev.1-V8-CB • 07-28-23
Customer Service: For Amazon Purchases: support@nuwavenow.com For All Other Purchases: help@nuwavenow.com