nuWave 47601 Rev.1 OxyPure Smart Air Purifier Owner’s Manual
- April 16, 2024
- nuwave
Table of Contents
- 47601 Rev.1 OxyPure Smart Air Purifier
- Product Information
- Specifications:
- Important Safeguards:
- Parts & Accessories:
- Assembly:
- WiFi Connection:
- Operation:
- Cleaning & Maintenance:
- Troubleshoot Guide:
- Limited Warranty:
- Q: How do I register my product?
- Q: What should I do in case of a damaged cord or plug?
47601 Rev.1 OxyPure Smart Air Purifier
“`html
Product Information
Specifications:
- Model: 47601 Rev.1
- Meets California ozone emissions limit
- CARB certified
Product Usage Instructions
Important Safeguards:
Always keep this manual handy for future reference. Read all
instructions and warnings to avoid misuse of the product.
Parts & Accessories:
Refer to the manual for a detailed list of parts and accessories
included with the product.
Assembly:
Follow the assembly instructions provided in the manual to set
up the product correctly.
WiFi Connection:
Refer to pages 8-9 of the manual for instructions on how to
connect the product to WiFi.
Operation:
Understand the operation of the product by referring to pages
9-12 of the manual for detailed instructions on its usage.
Cleaning & Maintenance:
Proper cleaning and maintenance guidelines are provided on pages
12-15 of the manual to ensure the longevity of the product.
Troubleshoot Guide:
In case of any issues, refer to page 16 of the manual for
troubleshooting tips and solutions.
Limited Warranty:
Details regarding the product’s warranty coverage can be found
on pages 17-19 of the manual.
FAQ
Q: How do I register my product?
A: You can register your product by scanning the QR code or
visiting nuwavenow.com/register. Opt-in for an additional year of
warranty for free.
Q: What should I do in case of a damaged cord or plug?
A: Do not operate the product with a damaged cord or plug.
Contact Customer Service immediately for assistance.
“`
OXYPURE ZERO® E2000 SMART AIR PURIFIER
Owner’s Manual
Model 47601 Rev.1
Questions or Comments? For Amazon Purchases: support@nuwavenow.com
For All Other Purchases: help@nuwavenow.com
THANK YOU!
Congratulations on your NuWave® purchase. We know there are many options
available and sincerely appreciate the trust you have placed in us.
For the last 30 years, we have committed to introducing products that promote
healthy living at affordable prices. By combining the highest quality designs
with cutting edge technology, we have always strived to blend feature,
function, and innovation into every product we make. We hope you will agree.
We would love to hear from you. Please feel free to reach out with any
feedback or comments that could improve your experience. We would also enjoy
hearing about your successes.
The best way to reach us is by email: For Amazon Purchases:
support@nuwavenow.com For All Other Purchases: help@nuwavenow.com
For Amazon Purchases
For All Other Purchases
support@nuwavenow.com
help@nuwavenow.com
Scan to Register nuwavenow.com/register
Register Today!
Protecting your investment is easy and rewarding. Simply scan the QR code or
visit nuwavenow.com/register to register. When you register, simply opt in for
an additional year of warranty. Don’t worry. There is no catch. We are
extending it absolutely FREE to show our appreciation!
Connect with Us!
2 | nuwavenow.com
nuwavenow
Visit nuwavenow.com to see other great products and accessories.
TABLE OF CONTENTS
OWNER’S MANUAL Important Safeguards …………………………………………….4-5 Parts & Accessories
…………………………………………………. 6 Assembly ……………………………………………………………….. 7 WiFi
Connection…………………………………………………….8-9 Operation ……………………………………………………………9-12
Cleaning & Maintenance ………………………………………12-15 Troubleshoot
Guide…………………………………………………. 16 Limited Warranty …………………………………………………17-19
Para la versión en español de este manual, visita www.nuwavenow.com
Meets California ozone emissions limit. CARB certified
U.S Environmental Protection Agency
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: · Reorient or relocate the receiving antenna. ·
Increase the separation between the equipment and receiver. · Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
nuwavenow.com | 3
IMPORTANT SAFEGUARDS
NOT INTENDED FOR OUTDOOR USE · HOUSEHOLD USE ONLY
ALWAYS KEEP THIS MANUAL HANDY FOR FUTURE REFERENCE.
READ ALL INSTRUCTIONS and WARNINGS: The failure to follow any of the important safeguards, warnings, or instructions for safe use is a misuse of the OxyPure that can void your warranty and create the risk of serious injury. When using the OxyPure, basic safety precautions should always be followed.
1. ONLY use the OxyPure for its intended 10. ALWAYS set up the OxyPure on a flat,
purpose.
stable surface.
2. To protect against the risk of electrical shock, DO NOT immerse the cord,
plug, or any part of the OxyPure in water or any other liquid.
3. Close supervision is necessary when the OxyPure is used by or near
children. The OxyPure is not intended for use by children, persons with
reduced physical, sensory, or mental capabilities, or those who lack expertise
or knowledge of this device.
4. DO NOT operate the OxyPure with a damaged cord, plug, after any
malfunction, or if the unit has been dropped or damaged in any way. Contact
Customer Service by emailing For Amazon Purchases: support@nuwavenow.com For
All Other Purchases: help@nuwavenow.com
5. Discard the protective plastic covering the power plug before use.
6. DO NOT run the cord under carpeting, throw rugs, runners or other
coverings.
7. DO NOT route the cord under furniture or appliances. Arrange the cord away
from high-traffic areas where it will not pose a tripping hazard.
8. DO NOT plug the OxyPure into an outlet or power strip that is being used
by other appliances.
9. Remove any dust or water from the plug, if needed.
4 | nuwavenow.com
11. DO NOT set up the OxyPure where it could be pushed, kicked, or tripped
over.
12. Leave at least 2-3 feet of space between the OxyPure’s vents and any
walls.
13. DO NOT install the OxyPure near a heating device, flammable or
combustible gases or vapors, or in areas exposed to moisture or water.
14. DO NOT operate the OxyPure on its side.
15. DO NOT place objects on top of the OxyPure.
16. DO NOT sit or stand on, or lean against, the OxyPure.
17. Alteration or modification of any part of the OxyPure, or the use of
attachments not recommended by the manufacturer, may cause fire, injury, or
damage to property.
18. As with most electrical units, electrical parts are live even when the
OxyPure is off. Be sure the OxyPure is unplugged when assembling.
19. DO NOT use the OxyPure in a factory or industrial setting where machine
oil may be present in the air.
20. Turn the power OFF on the OxyPure before unplugging it.
21. Unplug the OxyPure from outlet when the unit is not in use or will be
left unattended for an extended period of time;
IMPORTANT SAFEGUARDS
NOT INTENDED FOR OUTDOOR USE · HOUSEHOLD USE ONLY
before putting on or taking off parts; when removing or replacing the filters;
and before cleaning.
22. DO NOT operate the OxyPure if an abnormal sound or motion is detected.
23. If a hard or foreign object comes into contact with the fan, do not
operate. Turn off and unplug the OxyPure.
24. Inspect the OxyPure for any loose or missing parts before and after each
use. If parts are loose, damaged, or missing, contact Customer Service by
emailing For Amazon Purchases: support@nuwavenow.com For All Other Purchases:
help@nuwavenow.com
25. DO NOT pull, lift, drag, pick up, or carry the OxyPure by its cord.
26. DO NOT block the air inlet or outlet vents.
27. DO NOT operate the OxyPure without filters or the Filter Access Panel in
place.
28. DO NOT place anything with a strong odor or chemical on or close to the
odor sensor.
ELECTRICAL INFORMATION These servicing instructions are for use by qualified
personnel only. To reduce the risk of electric shock, do not perform any
servicing other than that contained in the operating instructions unless you
are qualified to do so.
Power-Supply Cords A short, detachable power-supply cord is provided to reduce
the risk of becoming entangled in, or tripping over, a longer cord. Longer
detachable power-supply cords or extension cords are available and may be used
if care is exercised in their use. If a longer, detachable power-supply cord
or extension cord is used:
1. The marked electrical rating of the extension cord should be at least as
great as the electrical rating of the appliance.
2. The longer cord should be arranged so that it will not drape over any
countertop or tabletop where it could be pulled on or tripped over
unintentionally.
3. The OxyPure should be operated on a separate electrical outlet from other
operating appliances due to wattage limitations.
WARNING
FILTER CHANGING PRECAUTIONS
1. Once all filters have been removed, the body of the OxyPure can be washed
with warm, soapy water. Dry thoroughly before replacing the filters.
2. ALWAYS use rubber gloves when handling the filters.
3. When removing dirty filters, ALWAYS do so outside or in a well ventilated
area.
4. ALWAYS replace your filters with NuWave filters made for your model of air
purifier.
RISK OF ELECTRIC SHOCK: To reduce the risk of electric shock, this equipment
has a polarized plug (one blade is wider than the other). This plug will fit
in a polarized outlet only one way. If the plug does not fit fully in the
outlet, reverse the plug. If it still does not fit, contact qualified
personnel to install the proper outlet. Do not alter the plug in any way.
These servicing instructions are for use by qualified personnel only. To
reduce the risk of electric shock, do not perform any servicing other than
that contained in the operating instructions unless you are qualified to do
so.
nuwavenow.com | 5
PARTS
1
Air Vent Part #: OXA1
Front Display 2 Touchpad Panel
Part #: OXA13
Handles 3 Part #: OXA3
Odor Sensor 4 Part #: OXP8
Base 5 Part #: OXA14
6
Inflow Vent Part #: OXA10
Filter Slot Cover 7 Part #: OXP6
Wheels 8 Part #: OXP9
Sensor Cover 9a Part #: OXP3
9b
Filter Sensor Part #: OXP7
Ozone Emission 10 Removal Filter
Part #: OXA6
Bio-Guard® Filter 2 11 Part #: OXA12
Bio-Guard® Filter 1
12
Part #: OXA7
Stainless Steel 13 Pre-Filter
Part #: OXA8
Front
3
1
2
4
7 5
8 6
Back
9a 9b
10
11
12 13
ORDERING PARTS
Keeping your OxyPure up and running is a breeze! To order additional filters
or parts… 1. Locate the part number on the above parts list. 2. Contact NuWave
Customer Service by emailing For Amazon Purchases: support@nuwavenow.com For
All Other Purchases: help@nuwavenow.com Or order online at www.nuwavenow.com
6 | nuwavenow.com
Open
1
Access to Filters
4 3 2 1
ASSEMBLY
Close
2
3
4
Stainless Steel Bio-Guard® Filter 1 Bio-Guard® Filter 2 Ozone Emission
Pre-Filter
Removal Filter
Before Use: 1. Make sure the OxyPure is unplugged. Open the
Filter Slot Cover on the back to expose the filters.
2. Remove all tape and pull the filters from their slots using the tabs or
handles.
3. Remove the plastic wrapping from the 1 Stainless Steel Pre-filter and the
4 Ozone Emission Removal Filter. (Bio-Guard® filters are not wrapped.)
4. Fully reinsert the filters into the Oxypure and close the Filter Slot
Cover.
5. Remove the sticker from the control panel.
4 3 2 1
Air Filter Assembly The OxyPure® comes with four different preassembled
filters inside the unit (see diagram above). Each filter is labeled with a
number. Match these with the slot numbers when installing the filters. When
the filters require cleaning, please refer to Cleaning &
Maintenance.
nuwavenow.com | 7
THE NUWAVE CONNECT APP
MONITOR AND CONTROL THE OXYPURE REMOTELY
The OxyPure is equipped to operate using WI-FI. This allows you to conveniently operate your new air purifier from nearly any location, whether at home or while you are out and about, as long as you have a reliable Internet connection.
Download the NuWave Connect App This is an optional feature that is not
required to operate your OxyPure.
Using the QR reader in your Camera App: 1. Scan the QR code below.
2. It will take you to the App’s download page on either the Google Play
Store or the Apple AppStore, then just follow the download and installation
instructions.
Downloading a QR reader App: If your phone doesn’t have that capability built-
in, simply download a 3rd-Party QR Scanning App before scanning the NuWave QR
Codes and you are ready to go. 1. Open your device’ mobile app store (Ap-
ple App Store or the Google Play Store).
2. Search for “QR code readers.” 3. Simply download the QR code reader to
your phone, open it, scan the code and you are ready to go.
Wi-Fi
Auto Scan Mode 1. Once you download the NuWave®
Connect app, ensure your phone is connected to your home Wi-Fi network on the
5GHz frequency and that your phone’s Bluetooth is on. 2. Turn on the OxyPure
and activate Wi-Fi Pairing Mode by pressing and holding AUTO until the light
next to the Wi-Fi symbol begins to blink rapidly. 3. In the NuWave® Connect
app, tap the + symbol, then tap Auto Scan and select your device. 4. Enter
your Wi-Fi network’s password and tap Confirm. If the connection is
successful, the app will display “Added Successfully” on the screen.
WiFi LED Status Light Pairing Mode & Standby Mode
Solid Light. The OxyPure is paired with the wifi
network and ready to be used.
Rapid Blinking Light. The OxyPure is in Pairing Mode. The OxyPure will stay in
Pairing Mode for up to 3 minutes or until your device is paired.
Slowly Blinking Light. The OxyPure is in AP Pairing Mode.
No Light. The OxyPure’s WiFi is off.
If the OxyPure did not connect to your network, the Wi-Fi light will turn off.
Repeat the steps for pairing. Make sure to select the proper Wi-Fi network and
type the correct password. Note: If your home network doesn’t broadcast in a
5GHz or a dual band broadcast frequency, contact your ISP to inquire about
setting up a 5GHz network.
8 | nuwavenow.com
AP Mode 1. If you can’t connect your OxyPure
using Auto Scan, follow the instructions in the app to reset the connection
process. 2. Press and hold AUTO until the Wi-Fi light begins blinking slowly
to enable AP Mode. 3. Tap the + symbol, then select the OxyPure unit you want
to add to the network. 4. Confirm that the Wi-Fi light on your OxyPure is
blinking slowly and tap AP Mode on your phone screen. 5. Connect your phone to
the available hotspot following the instructions on the screen. 6. Once
connected, return to the NuWave Connect app and the unit will begin connecting
automatically.
7. Once your OxyPure is successfully connected, tap Done.
EZ Mode 1. Tap the + symbol, then select the
OxyPure unit you want to add to the network. 2. Enter and confirm your Wi-Fi
network password. 3. Tap AP Mode in the top right of your screen, then select
EZ Mode to switch pairing modes. 4. Confirm that the Wi-Fi light on your
OxyPure is blinking rapidly. 5. Once the OxyPure is connected, tap Done.
SAVE THESE INSTRUCTIONS
OPERATING THE OXYPURE
CONTROL PANEL · POWER · MODES & FUNCTIONS
The OxyPure’s control panel allows you to turn the unit on and off, choose an
operating mode or function (see below), and monitor your filter health.
AUTO
WIFI
ULTIMATE CLEAN
ECO MODE
FAN SPEED
LOW
HIGH
SLEEP MODE
TIMER
HR RESET FILTER
TURBO
HR
AIR
ODOR
CLEAN
DIRTY NO
STRONG
ODOR ODOR
CLEAN FILTER 2/3
WIFI
Air/Odor Quality – Detects particles as small as 2.5/1000mm
Low PM Level
High PM Level
Particulate Matter (PM) with a diameter of 2.5 microns or less
0~5
5~10
10~20
20~30
30~50
Over 50
Fan Speeds
1
2
3
4
5
6
Air and Odor LEDs The OxyPure will display the Air/Odor quality based on the particulate matter in the air from low to high as represented below. If the PM level in the air exceeds the upper limit of the range, a warning is triggered with a beeping sound and a flashing LED. To turn off this warning, press AUTO and Fan Speed at the same time. Press the same buttons to turn the warning feature back on.
Low PM Level
High PM Level
nuwavenow.com | 9
OPERATING THE OXYPURE
Filter Functions Air purifiers operate more efficiently when all windows and
doors are closed. The OxyPure can purify the air in extra-large rooms.
Stainless Steel Pre-Filter Washable and reusable for up to 20 years. Captures
and collects large particles and allergens including pet hair, dander, and
pollen. Made from rust-free 18/8 stainless steel.
Bio-Guard® Filter 1 and 2: Washable and reusable for up to 20 years. 8,000V,
positive and negative charges capture particles as small as 0.1 microns, as
well as smoke, pollen, and allergens.
Ozone Emission Removal Filter Reusable for up to 20 years. Not washable.
Eliminates ozone emissions and other harmful airborne chemicals.
OPERATING BUTTONS
Power ON/OFF 1. Plug your OxyPure into an outlet.
The POWER button will be lit red for standby mode.
ULTIMATE CLEAN
ULTIMATE CLEAN Allows your Oxypure to automatically adjust to the highest fan
speed based on your air quality. (No time limit, cannot run with Auto).
2. Press POWER. The OxyPure will turn on and the POWER button will be lit green. · Each bar around AIR and ODOR will illuminate, this is measuring current air quality while the fan is on.
1. Press ULTIMATE CLEAN. The ULTIMATE CLEAN light will be lit green.
2. Press ULTIMATE CLEAN again to turn it off.
3. Press POWER again to turn the OxyPure off. · When you select a different
mode other than the default AUTO before turning off, the OxyPure will run the
previously selected mode when it is powered back on.
AUTO
AUTO Allows your OxyPure to adjust the fan speed automatically (No time limit,
cannot run with Fan Speed and Ultimate Clean).
ECO MODE ECO MODE Allows you to save energy by keeping the Oxypure fan off
until it’s needed. The POWER button will be lit yellow.
1. Press and hold ULTIMATE CLEAN for 2 seconds to activate. The Power icon
backlight will be yellow while ECO MODE is on.
2. Press and hold ULTIMATE CLEAN for 2 seconds again to deactivate ECO MODE.
1. Press AUTO. The AUTO light will be lit. 2. Press AUTO again to turn off
function.
WIFI WIFI Allows you to connect the OxyPure to your Wi-Fi network. 1. Press
and hold AUTO to initiate Wi-Fi
pairing function. See page 8 for details.
FAN SPEED
LOW HIGH FAN SPEED Allows you to adjust the Oxypure’s fan speed to 6 different
speeds (LOW to HIGH). (Cannot run with Auto and Turbo).
1. Press FAN SPEED to adjust. 2. To go back to the lowest fan speed,
press FAN SPEED until the first green bar is lit.
10 | nuwavenow.com
OPERATING THE OXYPURE
SLEEP MODE SLEEP MODE Allows your Oxypure fan to still be active while the LED
lights are turned off. Adjust the fan speed to your preference prior turning
on sleep mode.
1. Manually set FAN SPEED to desired setting.
2. Press and hold FAN SPEED for 2 seconds again to activate SLEEP MODE.
3. To turn off SLEEP MODE, press any button.
NOTE: ULTIMATE CLEAN and TURBO will work while the Oxypure is in SLEEP MODE.
TIMER
TIMER
HR
Allows you to choose the Oxypure’s duration of operation from ½ hour, 1, 2, 4,
8, or 12 hours by settng a countdown timer to shut off the Oxypure or end the
current function.
1. Press TIMER. The bar next to ½ hour will be lit. After pressing timer six
times, all bars will be lit.
2. Press TIMER once more to turn the TIMER off.
· After about 6 months the CLEAN FILTER 2/3 light will turn Orange indicating
that the Bio-Guard® Filters 1 and 2 SHOULD BE CLEANED.
· After 12 months the CLEAN FILTER 2/3 light will turn Red indicating that the
Bio-Guard® Filters 1 and 2 MUST BE CLEANED. · After the filters are cleaned
and the indicator is reset, the first green bar around AIR will be lit.
TURBO
TURBO
HR
Allows you to operate the Oxypure at the highest fan speed 6 to clean the air
for a selected duration of time from ½ hour, 1, or 2 hours. To add more time
press Timer. (Cannot run with Fan Speed).
1. Press TURBO to select and set the duration of operation to ½ hour, 1, or 2
hours. When the selected time has finished, TURBO will shut off automatically.
2. To exit TURBO mode, press TURBO four times.
TO MUTE BEEP SOUNDS (TURBO) Press and hold TURBO for 4 seconds untill 3 beeps
are heard. Repeat to unmute.
RESET FILTER RESET FILTER The CLEAN FILTER 2/3 light will illuminate
indicating that the Oxypure’s Bio-Guard® Filters 1 and 2 need to be cleaned.
To reset the indicator light after cleaning the filters,
1. Press and hold TIMER for 2 seconds, until 2 beeps are heard and the CLEAN
FILTER 2/3 light turns off.
COLORS OF CLEAN FILTER 2/3 light:
· After about 3 months the green CLEAN FILTER 2/3 light will turn Yellow
alerting you that the Bio-Guard® Filters 1 and 2 SHOULD BE CLEANED to maintain
optimal performance.
AIR
CLEAN DIRT AIR QUALITY INDICATOR The OxyPure will automatically measure and
display the current air quality in the room. The colored bars around AIR will
illuminate, increasing and decreasing according to air quality. See page 9 for
details on AIR/ODOR QUALITY.
ODOR
NO
STRONG
ODOR ODOR
ODOR QUALITY INDICATOR
The OxyPure will automatically measure
and display the current odor quality in the
room. The colored bars around ODOR
will illuminate, increasing and decreasing
according to odor quality. See page 9 for
details on AIR/ODOR QUALITY.
nuwavenow.com | 11
OPERATING THE OXYPURE
Your OxyPure can easily be moved from one location to another. Just hold the OxyPure by the handles on each side and roll the OxyPure to the chosen location. The wheels underneath provide extra maneuverability and mobility whenever it’s needed.
Wheels
Handles
Cleaning & Maintenance
Before First Use Wipe the Top Vent and In Flow Vent with a slightly damp cloth
or paper towel. Dry thoroughly before use.
TOP
Top Vent
After Use Your OxyPure should be cleaned periodically and after excessive use to ensure proper performance and function. To clean the outsides of the OxyPure, use a cloth, paper towel or vacuum brush attachment to remove dust and other particles from the vents. Clean tougher buildup with a damp cloth or paper towel, then dry thoroughly.
Cleaning the Top Vent and In Flow Vent
1. Turn off and unplug the OxyPure.
Inflow Vent BOTTOM
Cleaning the Filters
2. Use a vacuum with a brush attachment to remove any dust and debris.
3. If needed, use a slightly wet paper towel or damp cloth to remove heavier
buildup. Do not use any harsh abrasives or cleaning pads on the Top Vent or
any other part of the OxyPure.
When cleaning filters it is recommended to: · Wear a mask. · Wash your hands after cleaning. · Allow the filters to air dry thoroughly, this can take 12-24 hours. · NEVER use a heat source such as blow dryers or place by heat vents to dry.
12 | nuwavenow.com
CLEANING & MAINTENANCE
Cleaning the Filters The filters inside the Filter Slot need to be cleaned on schedule to help your OxyPure maintain optimum performance.
4 3 2
1
1 4
1. Remove the Filter Slot Cover in the rear of the OxyPure using its built-in
handle.
2. Slide out the filters for cleaning.
3. After washing allow the Filters to completely dry before you reinserting
them. · Never place a wet filter into the OxyPure.
· Ensure the Filter Slot Cover is properly aligned and secure
Stainless Steel Pre-Filter
2
COLORS OF CLEAN FILTER 2/3 light:
· After about 3 months the green CLEAN FILTER 2/3 light will turn Yellow
alerting you that the Bio-Guard® Filters 1 and 2 SHOULD BE CLEANED to maintain
optimal performance.
· After about 6 months the CLEAN FILTER 2/3 light will turn Orange indicating
that the Bio-Guard® Filters 1 and 2 SHOULD BE CLEANED.
· After 12 months the CLEAN FILTER 2/3 light will turn Red indicating that the
Bio-Guard® Filters 1 and 2 MUST BE CLEANED.
Bio-Guard® Filter 1
CONTROL PANEL
AIR
CLEAN
DIRTY
CLEAN FILTER 2/3
Ozone Emission Removal Filter
3
Bio-Guard® Filter 2
nuwavenow.com | 13
CLEANING & MAINTENANCE
Cleaning the Stainless Steel Pre-Filter The Pre-Filter collects large
particles and will need to be cleaned at least once every two months depending
on use. The filter can be cleaned using a vacuum with a brush attachment or in
warm soapy water.
1. Remove the Filter from slot 1 . 2. Use a vacuum with a brush
attachment and vacuum up and down then side to side. 3. Flip and repeat to
vacuum the other side of the Filter.
OR
1. Clean the Filter with warm soapy water.
2. Rinse the Filter thoroughly until the water is clear, and remove any soap
particles.
3. Allow the Filter to air dry completely BEFORE placing it back into the
OxyPure (drying can take up to 12-24 hours).
Cleaning the Bio-Guard® Filters 1 & 2 1. Remove the Filter from slots 2 + 3 .
2. Spray both sides of the Filter with a mild degreaser or dish soap and set
aside for 2-3 minutes in the sink or a cleaning tote caddy.
3. Lift Filter to drain excess cleaner. Submerge the Filter in warm water.
Shake and flip to rinse.
4. Continue shaking and flipping in warm water until the water is clear. (The
water may need to be changed several times).
5. Drain all excess water by turning filter.
6. Allow the Filter to air dry completely BEFORE placing it back into the
OxyPure (drying can take up to 12-24 hours).
Cleaning the Ozone Emission Removal Filter 1. Remove the Filter from slot 4 .
2. Use a vacuum with a brush
attachment and vacuum up and down then side to side. 3. Flip and repeat to
vacuum the other side of the Filter. 4. Repeat this process on the other side.
Cleaning the Filter Sensor The Filter Sensor is located on the back, above the
Filter Slot Cover. 1. Open the panel
(Sensor Cover).
2. Using a dry cotton swab or small, soft brush, gently remove any dirt or dust from the Sensor.
Sensor Cover
3. For heavier buildup on the Sensor, wipe it with a slightly wet cotton swab.
4. Remove any moisture with a dry cotton swab. · The Filter Sensor requires regular cleaning (approx. every 3 months) for the OxyPure to operate efficiently.
· If your OxyPure is set up in an area with high dust accumulation, more frequent cleaning of the Filter Sensor is needed.
· Do not use the cotton swab on any part or area other than the Filter Sensor.
14 | nuwavenow.com
CLEANING & MAINTENANCE
Cleaning the Odor Sensor Opening The Odor Sensor is located on the upper right
side corner of the OxyPure underneath the small grill opening. · Keep the Odor
Sensor clear of dust and debris by cleaning with
a vacuum brush attachment. · DO NOT tamper or spray inside or near the odor
sensor. This
may cause the sensor to malfunction and will void the warranty.
Odor Sensor
AUTO WIFI
ULTIMATE CLEAN
ECO MODE
SLEEP MODE
LOW
HIGH
TIMER HR
RESET FILTER
CLEAN FILTER 2/3
WIFI
ODOR ODOR
TURBO HR
CLEAN
DIRTY NO
STRONG
FAN SPEED
AIR
ODOR
Cleaning the Top Vent The Top Vent of your OxyPure can be removed to clean
with a vaccum with a brush attachement or cleaned in mild soapy water and
dried thoroughly. To clean the surface underneath the Inner Vent Screen. 1.
Turn the OxyPure off and unplug it from
the wall outlet.
2. Lift the Top Vent using the built-in tab.
3. Using a vacuum with a brush attachment or duster, clean any dust or
accumulated particles from the surface an Inner Vent Screen.
To clean the inner wall opposite of the fan or to remove an object that has
fallen through the Inner Vent Screen.
1. After removing the Top Vent, locate the two screws at the top of each side
of the vent.
2. Use a Phillips screwdriver to loosen only the two screws shown on the
diagram to the right. Be sure to set in a secure location.
3. Lift up the Inner Vent Screen.
4. After cleaning the inner wall with a soft cloth or paper towel, or duster.
Reassemble the Inner Vent, retightening the two screws, and replace the Top
Vent. · Make sure all parts are secure before plugging in the OxyPure and
turning it on again.
Note: DO NOT unscrew the four outer screws located toward the corners. Doing
so will void your warranty. DO NOT immerse the OxyPure in water. Clean with a
damp sponge or cloth and wipe dry. Make sure all parts and covers are securely
attached.
nuwavenow.com | 15
TROUBLESHOOTING GUIDE
The OxyPure does not turn on.
1. The plug is not in the wall outlet. Plug into wall outlet. 2. POWER on the
touchpad panel is not on. Press the POWER button. 3. The Filter Slot Cover in
the back rear is off or loose. Make sure Filter Slot Cover is on securely.
Check that the tabs are not damaged or broken off. 4. Be sure the filters are
secure in their designated slots. Pull each filter out partially, then
securely slide back into its slot. 5. Check if the Oxypure is on sleep mode.
TIMER does not work when pressed.
The OxyPure is not reading the function selected. Press FAN SPEED or AUTO,
then press TIMER.
The fans are not blowing.
1. An appropriate outlet is not being used. Make sure outlet has appropriate
voltage for use. 2. The Filter Slot Cover in back rear is not properly in
place. Make sure Filter Slot Cover is on
securely. 3. Check the Air Vent for obstructions. See page 15 on how to remove
the Inner Vent Screen.
Speed of the airflow is not changing when FAN SPEED is pressed.
The OxyPure may be in AUTO mode. Set the OxyPure to another operating mode on
the touchpad then press “FAN SPEED”.
Airflow from the Top Vent is weak.
The air filter(s) are dirty. Clean the air filters.
The OxyPure is producing smoke or odor.
The air filter(s) are dirty. Clean the air filters. If the problem continues,
contact Customer Service by emailing: For Amazon Purchases:
support@nuwavenow.com For All Other Purchases: help@nuwavenow.com
CLEAN 2/3 FILTER Indicator has not reset after the filter(s) have been
cleaned.
1. The Filter Sensor is not reading the reinstalled filter(s). Turn the
OxyPure off then on again. Press and hold down TIMER for 2 seconds until a
beep is heard.
2. Turn the OxyPure off, unplug and adjust the filter(s) by removing and
reinstalling them into their proper slots. Plug in and turn the OxyPure ON
again.
3. The Filter Slot Cover in back rear is not securely in place. Make sure
Filter Slot Cover is on securely.
4. The Filter Sensor is dirty. Clean the Filter Sensor.
ULTIMATE CLEAN does not come on when pressed.
The OxyPure is not reading the function selected. Turn the OxyPure on and off
by pressing POWER twice.
Power is blinking red.
1. The Bio-Guard® filter is not properly installed or is loose. Turn off and
unplug the OxyPure. Check that the filters #1 and #2 are properly installed
into their correct slots and are not loose. Plug in the OxyPure and press
POWER to turn it on.
2. When the Filter Slot Cover is removed, POWER will be backlit solid red.
Pressing POWER will make it blink. However, as a safety measure, the OxyPure
will not operate when the Filter Slot Cover is removed. Ensure that Filter
Slot Cover is installed securely.
The Odor/Air indicators are flashing or on high.
1. Place the OxyPure in a different room, and run manually for 8 hours. 2.
Clean the odor and filter sensors. If the problem persists, contact Customer
Service by emailing For Amazon Purchases: support@nuwavenow.com For All Other
Purchases: help@nuwavenow.com
16 | nuwavenow.com
LIMITED WARRANTY
THE MANUFACTURER WARRANTS NuWave, LLC warrants that the OxyPure Zero® E2000
will be free from manufacturer defects for 5 years from the date of purchase,
under normal household use, and when operated in accordance with the
Manufacturer’s written instructions. The Limited Warranty covers the Original
Purchaser only. The Manufacturer will provide the necessary parts and labor to
repair the product at the NuWave LLC Service Department. After the expiration
of the warranty, the cost of the parts and labor will be the responsibility of
the owner.
THE WARRANTY DOES NOT COVER The Limited Warranty is voided if repairs are made
by an unauthorized dealer, or the serial number data plate is removed or
defaced. Normal deterioration of finish due to use or exposure is not covered
by this Warranty. This Limited Warranty does not cover failure, damages, or
inadequate performance due to accident, acts of God (such as lightning),
fluctuations in electric power; alterations, abuse, misuse, misapplications,
corrosive-type atmospheres, improper installation; failure to operate and
maintain the unit in accordance with the Manufacturer’s written instructions;
failure to regularly clean and maintain the unit and reusable filters in
accordance with the Manufacturer’s written instructions; abnormal, commercial,
or rental uses; or resold units. NuWave LLC reserves the right to void the
Limited Warranty, where allowable by law, for products purchased from an
unauthorized dealer.
TO OBTAIN SERVICE The owner shall have the obligation and responsibility to
pay for all services and parts not covered by the warranty; prepay the freight
to and from Service Department for any part or system returned under this
warranty; and carefully package the product using adequate padding material to
prevent damage in transit. The original container is ideal for this purpose.
Include in the package the owner’s name, address, daytime telephone number, a
detailed description of the problem, and RGA (Return Goods authorization
number). To obtain the RGA number, email us at:
For Amazon Purchases: support@nuwavenow.com For All Other Purchases:
help@nuwavenow.com
Provide the product model & serial number and proof of date of purchase (a
copy of the receipt) when making claims under this warranty.
MANUFACTURER’S OBLIGATION The Manufacturer’s obligation under this Limited
Warranty is limited, to the extent allowable by law, to repairing or replacing
any part covered by this Limited Warranty which upon examination is found to
be defective under normal use. The Limited Warranty is applicable only within
the continental United States and only to the original purchaser of the
manufacturer’s authorized channels of distribution.THE LIMITED WARRANTY MAY
NOT BE ALTERED, VARIED OR EXTENDED EXCEPT BY A WRITTEN INSTRUMENT EXECUTED BY
THE MANUFACTURER. THE REMEDY OF REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS
LIMITED WARRANTY IS EXCLUSIVE. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE
FOR ANY
nuwavenow.com | 17
LIMITED WARRANTY
CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANY PERSON, WHETHER OR NOT OCCASIONED
BY NEGLIGENCE OF THE MANUFACTURER, INCLUDING WITHOUT LIMITATION, DAMAGES FOR
LOSS OF USE, COSTS OF SUBSTITUTION, PROPERTY DAMAGE, OR OTHER MONEY LOSS.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation exclusions may not apply. This
Limited Warranty gives specific legal rights, and there may also be other
rights which vary from state to state. EXCEPT AS OTHERWISE EXPRESSLY PROVIDED
ABOVE, THE MANUFACTURER MAKES NO WARRANTIES EXPRESSED OR IMPLIED ARISING BY
LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ANY OTHER PERSON. READ
YOUR OWNER’S MANUAL. IF YOU STILL HAVE ANY QUESTIONS ABOUT OPERATION OR
WARRANTY OF THE PRODUCT, PLEASE CONTACT NUWAVE LLC.
DISPUTE RESOLUTION PROCEDURE For disputes relating to use of the website or
use or purchase of a NuWave product or service (collectively “Disputes”), you
agree to first contact NuWave LLC at legal@nuwavenow.com. If we cannot resolve
your dispute informally, any and all disputes shall be submitted to final and
binding arbitration. You may start the arbitration process by submitting in
writing a demand to the American Arbitration Association (“AAA”) and sending a
copy to NuWave. NuWave will pay all filing costs. A single arbitrator of the
AAA will conduct the arbitration in a location convenient to you or by phone.
The arbitrator’s award will be binding and may be entered as a judgment in a
court of competent jurisdiction. The arbitration will be conducted in
accordance with the provisions of AAA’s Commercial Arbitration Rules and
Mediation Procedures in effect at the time of submission of your demand for
arbitration. See https://www.adr.org/sites/default/files/CommercialRules_Web.
pdf. Except as may be required by law as determined by an arbitrator, no party
or arbitrator may disclose the existence, content, or results of any
arbitration hereunder without prior written consent of both parties.
A. WAIVER OF RIGHT TO SUE. By agreeing to arbitration, you understand that, to
the maximum extent permitted by law, you are agreeing to waive your right to
file suit in any court, to a court hearing, a judge trial, or a jury trial.
B. CLASS ACTION WAIVER. To the maximum extent permitted by law, you expressly
agree to refrain from bringing or joining any claims in any representative or
classwide capacity, including but not limited to, bringing or joining any
claims in any class action or class-wide arbitration.
18 | nuwavenow.com
LIMITED WARRANTY
C. OPT OUT PROCEDURE. To request to opt out of arbitration you must contact
NuWave LLC at legal@nuwavenow.com, NuWave LLC, 560 Bunker Ct., Vernon Hills,
IL 60061, U.S.A. You will have thirty (30) days from the date of product
delivery to opt out of arbitration with respect to any dispute arising out of
or relating to use or purchase of any NuWave product. If more than 30 days
have passed, you are not eligible to opt out of arbitration and will have
waived your right to sue or participate in a class action with respect to the
dispute arising out of your purchase or use of a NuWave product. For any
dispute arising out of your use of NuWave’s website, you have thirty (30) days
from the date you provided information to the website to opt out of
arbitration. If more than 30 days have passed, you are not eligible to opt out
of arbitration and you will have waived your right to sue and participate in a
class action with respect to the dispute arising out of your use of NuWave’s
website.
D. SOME MATTERS ARE NOT SUBJECT TO ARBITRATION. Notwithstanding the foregoing,
the following shall not be subject to arbitration and may be adjudicated only
in the state and federal courts of Illinois: (i) any dispute, controversy, or
claim relating to or contesting the validity of our intellectual property
rights and proprietary rights, including without limitation, patents,
trademarks, service marks, copyrights, or trade secrets; (ii) an action by a
party for temporary, preliminary, or permanent injunctive relief, whether
prohibitive or mandatory, or other provisional relief; or (iii) interactions
with governmental and regulatory authorities. You expressly agree to refrain
from bringing or joining any claims in any representative or class-wide
capacity, including but not limited to, bringing or joining any claims in any
class action or any class-wide arbitration.
READ YOUR OWNER’S MANUAL If you still have any questions about operation or
warranty of this product, please contact NuWave LLC by emailing
For Amazon Purchases: support@nuwavenow.com For All Other Purchases:
help@nuwavenow.com.
nuwavenow.com | 19
OXYPURE ZERO® E2000 SMART AIR PURIFIER
FOR HOUSEHOLD USE ONLY 120VAC / 60 Hz / 120W
Model: 47601 Rev. 1
Para la versión en español de este manual, visita www.nuwavenow.com.
For patent information please go to: www.nuwavenow.com/legal/patent
Designed & Developed in USA NuWave LLC 560 Bunker Ct. Vernon Hills, IL 60061,
U.S.A.
Email: For Amazon Purchases: support@nuwavenow.com For All Other Purchases:
help@nuwavenow.com
Made in China ©2023 · NuWave, NuWaveNow, and OxyPure are registered trademarks
of NuWave LLC · All Rights Reserved.
EPA Establishment Number: 101594-CHN-1
Item: BM47601 Rev.1-V1-JD 11-29-23
References
- Nuwave® | Air Purifier, Air Fryer, Indoor Grill, Oven and More
- Nuwave® | Air Purifier, Air Fryer, Indoor Grill, Oven and More
- Nuwave® Patents: Innovations Redefining Home Cooking and Appliances